Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grid services”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Anomaly Detection and Mitigation for Dynamic Frequency Regulation in Hydropower-Battery Systems

Hydropower operators and energy storage providers are increasingly interested in participating in frequency regulation services, driven by the incentives offered by independent system operators, such as the PJM Interconnection. This transition, however, unfolds against the backdrop of a modernizing and rapidly digitizing power grid, exposing the integrated legacy infrastructure to a multitude of cybersecurity threats. This work presents an approach for developing an anomaly detection and mitigation system to address cybersecurity challenges during the participation of a hydropower-integrated battery energy storage system (BESS) in a frequency regulation market. The applied anomaly detector utilizes machine learning algorithms to provide detailed classification of cyber-physical events. Later, the applied mitigation system triggers predefined corrective actions to minimize the impact of data integrity attacks on the regulation market and system stability. We evaluated the proposed approach on a hydropower-integrated BESS topology, specifically analyzing the slow regulation signal (Reg A) coming from the PJM market. Our simulation results demonstrate that the proposed approach performs well in detecting data integrity attacks within the allocated time frame and also minimizes the system's transient instability during the participation of hydropower and BESS in the regulation market.

battery energy storage system↗

Evaluation of Hydrogen Production Feasibility for a Light Water Reactor in the Midwest

Increased electricity production from renewable energy resources coupled with low natural gas prices has caused existing light-water reactor (LWRs) to experience ever diminishing returns from the electricity market. Via partnership among Idaho National Laboratory (INL), The National Renewable Energy Laboratory (NREL), Argonne National Laboratory (ANL), Exelon, and Fuel Cell Energy a techno-economic analysis on the viability of retrofitting existing pressurized water reactors (PWRs) to produce hydrogen (H2) via high temperature steam electrolysis (HTSE) has been conducted. Such integration would allow nuclear facilities to expand into additional markets that may be more profitable in the long-term. To accommodate such an integration, a detailed analysis of HTSE process operation, requirements, and flexibility was conducted. Technical analysis includes proposed nuclear system control scheme modifications to allow dynamic operation of the HTSE via both thermal and electrical connection to the nuclear plant. High fidelity Modelica simulations showcase the viability of such control schemes. However, due to limited knowledge of solid oxide fuel cell (SOFC) stack degradation due to thermal gradients; thermal cycling of the HTSE was not included. Therefore, the control schemes proposed are only utilized to re-distribute steam at startup and only the portion of electricity utilized in the electrolyzers is cycled. From the detailed analysis of the nuclear integration and the HTSE process design, a comprehensive cost estimation was conducted in the APEA and H2A models to elucidate capital and operational costs associated with the production, compression, and distribution of hydrogen from a nuclear facility. Alongside this costing analysis, market analyses were conducted by NREL and ANL on the electric and hydrogen markets respectively in the PJM interconnect. Utilizing the electricity data market projections in the PJM interconnect from NREL and hydrogen demand/pricing projections from ANL a five variable sweep over component capacities, discount rates, and hydrogen pricing was completed using the stochastic framework RAVEN (Risk Analysis Virtual ENVironment) through its resource dispatch plugin HERON (Heuristic Energy Resource Optimization Network). Each combination of variables was evaluated stochastically four times over a seventeen year timespan from 2026-2042 (inclusive) to determine the most economically advantageous solution. Following the five variable sweep an optimization was conducted about the best sweep point to determine optimal component sizing and setpoints. Results suggest positive gain is achievable at all projected hydrogen market pricing levels and at all discount rates. However, exact component sizing and net returns vary based on these values and if incorrect sizing is selected; major net losses can occur. The optimal result occurred with set points as follows: high hydrogen prices, the largest possible HTSE unit in the sweep set at 7.47 kg/sec [645.4 tpd], a contractual hydrogen market agreement 7.29 kg/sec [629.8 tpd], and a hydrogen storage size 115,188 kg. The analysis suggested that with a discount rate of 8%, a ΔNPV = 1.2 billion over the seventeen year span can be achieved. The results illuminate that by operating in multiple markets the nuclear facility is capable of avoiding sale of electricity during times of low electricity market pricing, while maintaining the ability to capitalize on the high electricity market pricing. It should be noted that the analysis conducted in this report is a differential cash flow analysis and as such does not present profit levels. Instead it highlights the net benefit between building and competing in the hydrogen market utilizing nuclear facilities and conducting business as usual in the electricity markets. Additionally, results presented in this report exhibit conservatism due to four key assumptions: Given the limited knowledge on SOFC stack degradation due to thermal gradients the high temperature steam electrolysis plant is not allowed to thermally cycle. This limitation decreases electricity generation capacity in the nuclear plant, reducing capacity payments and the maximum output to the electrical grid. This analysis considers building a separate hydrogen pipeline for use in the nuclear facility. Research is currently being conducted to determine if existing natural gas pipelines can accommodate direct hydrogen injection. If hydrogen can be integrated into existing natural gas pipelines then a capital savings of ~$19,000,000 per kg/sec [1 kg/sec = 86.4 tpd] of installed HTSE capacity could be realized. Fast transients in the electric grid are typically served by flywheels and electric batteries. With electrolysis only operation the nuclear plant can flex its electricity just as quickly. However, for this analysis, the ancillary services market has been neglected. Should the nuclear plant have the ability to operate in the ancillary services market during periods when it is producing hydrogen, an additional substantial income stream that would increase overall system profitability could be considered. Subsidies for non-emitting generation technologies are not introduced in the cash flow analysis, but instead are completed assuming zero subsidies. Profitability is based solely on electricity pricing. Electric pricing is assumed to never go negative. Instead, it is assumed overall system curtailment by the Independent System Operator (ISO) will occur in such a manner that pricing remains at or above zero. This assumption inflates the “business as usual” scenario, thus decreasing the ΔNPV calculated. If negative pricing scenarios continue to occur as they do today, one would expect a further increase in ΔNPV. Overall, results advocate that, through market diversification, nuclear power plants have the potential to substantially increase current profit margins, increase market penetration, and ultimately solidify their place as a mainstay in energy production.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Four-Dimensional Oceanic and Atmosperic Data Assimilation with Tropical Rainfall Measuring Mission Data

An oceanic data assimilation system which allows to utilize the forthcoming Tropical Rainfall Measuring Mission (TRMM) data has been developed and applied to the Pacific Ocean to produce the velocity field. The assimilated data will be indispensable to examine the effects of rainfall and its variability on the structure and circulation of the tropical oceans and to assess the impact of global warming due to the increase of carbon dioxide on the ocean circulation system and the marine pollution caused by oil spill and ocean damping of radionuclide. The data will also provide the verification for the oceanic and ocean-atmosphere coupled General Circulation Models (GCM's). The system consists of oceanic GCM, analysis scheme and data. In the system the flow field has been determined to be physically consistent with the observed density field and the sea surface winds derived from the Special Sensor Microwave Imagery (SSM/I) data which drive the ocean current. The time integration has been performed for five years until the flow field near the surface attained the steady state starting from the rest ocean with observed temperature and salinity fields, and the SSM/I surface wind velocity. The resultant flow field showed high producibility of the system. Especially the flow near the ocean surface agreed well with available observed data. The system, for the first time, succeeded to produce the eastward subtropical current which has been discovered in the joint investigation on Kuroshio current (CSK) in the 1960s. To verify the quality of the flow field a trajectory analysis has been carried out and compared with the Algos buoy data. BRIEF DESCRIPTION OF THE DATA ASSIMILATION SYSTEM ## Oceanic GCM and analysis scheme--The basic equations are much the same as used for the GCM's, except for the Newtonian damping terms introduced into the prediction equations for the potential temperature and salinity to maintain these fields as observed. The C grid of 2'lat. by 2'long. in horizontal and the 11 vertical levels are applied to the entire Pacific Ocean. At the east and west ocean boundaries the periodic boundary conditions are applied creating fictitious ocean there. The SMAC Method is used to increase the accuracy of mass conservation. * Data--The JODC temperature and salinity data obtained from 1906 to 1988 are used in the system between Long.100'E. and 60'W. The surface wind data are derived from the SSM/I data by Dr-R. Atlas of NASA/GSFC. The data set contains every 6 hours data from July 1987 to June 1989 on the grid of 2'lat. by 2.5'long. The averaged for the whole period and then interpolated into the 2'lat. by 2'long. grid data are used to force the system. The sea bottom topography data was based on the General Bathymetric Chart of the Ocean (GEBCO) supplied by the Canadian Hydrographic Service under contract with the International Hydrographic Organization and International Oceanographic Commission of UNESCO.

Takano, Kenji↗

Flexibility Auctions: A Framework for Managing Imbalance Risk

As the electricity generated by variable resources grows, system operators and variable resources have to manage challenging imbalances between forward and real-time markets. The Flexibility Auction is a novel approach for managing imbalances as it will allow resources with imbalance risk to hedge their production by buying flexibility options. The flexibility options are offered by grid-connected resources that can provide physical flexibility. This presentation will focus on the design of the Flexibility Auction, its properties, and how it can complement system-level services such as CAISO's proposed imbalance reserves. The presentation will include simple examples to illustrate the impact of the Flexibility Auction on the market participants and the system's imbalance risk.

auction↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

As we know, power transformers are the most critical asset of the transmission network. Although highly reliable, they still can fail prematurely or ultimately retire at the end of their service life. In today’s design practices, transformers are tailored to their specific application and therefore cannot replace each other unless identical. Additionally, they provide minimal support to the grid operation and therefore limit the grid flexibility and resiliency when facing severe conditions. In this presentation, we will introduce the concept of flexible power transformer and demonstrate how one single unit can serve as a spare to multiple units in a given fleet, allow to control the power flow between transformers or lines operating in parallel and ultimately be used to limit subsequent faults in transmission lines. We will also introduce the world’s first prototype in operation, a 60MVA, 165kV flexible autotransformer.

flexible power transformer, autotransformer, varia↗

Multi-decade high-resolution regional hindcasts for wave energy resource characterization in U.S. coastal waters

Long-term, high-resolution, regional wave hindcast datasets were generated using unstructured-grid Simulating WAves Nearshore (SWAN) models for the U.S. coastal waters to support nearshore wave energy development in the U.S. including those bordering U.S. territorial islands. The model domains resolved the entire U.S. exclusive economic zones, with a spatial resolution of approximately 200 m nearshore. The regional SWAN models were driven by the global WAVEWATCH III® model outputs and run for a 42-year period from 1979 to 2020. Extensive model validations were performed using buoy observations and altimeter data. Regional resource characterization was performed based on hindcast data points at 2 km from shore and along the 100 m isobath. Aggregations of wave resource parameters were produced, and spatial and seasonal variations were analyzed for all the regions. Wave resource metrics recommended by international standards, including a 3-hour time series of six resource parameters, hourly frequency- and directionally resolved wave spectra at selected “virtual buoy” locations, and average-annual values of omni-directional wave power, significant wave height, and energy period are publicly disseminated through an Amazon Web Service and a Marine Energy Atlas web application tool to facilitate wave energy research and a wide range of coastal ocean applications.

16 TIDAL AND WAVE POWER↗

The Technical and Economic Potential of Hydrogen within the United States

Hydrogen markets have an opportunity to grow as its value as an energy intermediate increases. Hydrogen’s estimated serviceable consumption potential in the United States is 106 MMT/yr which is a ten-fold increase over the current market size. That opportunity is driven primarily by increased demands for metals refining, biofuel and hydrocarbon production, supplementing the natural gas system, seasonal storage for the electricity grid, and fuel cell electric vehicles. The U.S. has many renewable, nuclear, and fossil resources that each could meet that demand itself. The economic potential, which considers both costs to produce hydrogen and willingness of applications to pay for it, is 22 to 41 MMT/yr. The range is impacted by factors that impact the cost to produce including the price of natural gas and the cost of electrolyzers. It is also impacted by competition to provide the same services as hydrogen including electrification.

electrolysis↗

Optimized Dispatch of Distributed Energy Resources for Resiliency and Power Quality Improvements at the Grid-Edge

Distributed Energy Resources (DERs) installed on low-voltage distribution systems, both utility-owned and nonutility owned may be employed to make improvements to system resiliency and power quality, in addition to simply serving load demand. By selectively dispatching active and reactive power from these existing DERs, improvements in voltage profiles and service availability during adverse events may be achieved. Further benefits can be gained by optimally choosing which DERs to dispatch power from, and the distribution of power from those DERs. For a given operating condition, using Linear Programming methods, optimal power dispatch values for individual DERs can be determined, while considering variables such as voltage gains, losses in the lines and the DERs, and DER reserve capacities. One such optimization technique is developed in this paper, and results from a real-time simulation study on a modified IEEE 13-bus distribution system with three DERs, are being presented. The operation of the optimized DER selection and dispatch algorithm is shown during normal operation of the transmission system when the DERs operate in grid-connected mode. Similar analyses can drive decision making during transmission system failure when the DERs operate in grid-forming or islanded mode.

Chowdhury, Prithwiraj Roy↗

Investigating the Vulnerabilities of the Direct Transfer Trip Scheme for Network Protector Units in the Secondary Networks of Electric Power Distribution Grids

Network protector units (NPUs) are crucial parts of the protection of secondary networks to effectively isolate faults occurring on the primary feeders. When a fault occurs on the primary feeder, there is a path of the fault current going through the service transformers that causes a negative flow of current on the NPU connected to the faulted feeder. Conventionally, NPUs rely on the direction of current with respect to the voltage to detect faults and make a correct trip decision. However, the conventional NPU logic does not allow the reverse power flow caused by distributed energy resources installed on secondary networks. The communication-assisted direct transfer trip logic for NPUs can be used to address this challenge. However, the communication-assisted scheme is exposed to some vulnerabilities arising from the disruption or corruption of the communicated data that can endanger the reliable operation of NPUs. This paper evaluates the impact of the malfunction of the communication system on the operation of communication-assisted NPU logic. To this end, the impact of packet modification and denial-of-service cyberattacks on the communication-assisted scheme are evaluated. The evaluation was performed using a hardware-in-the-loop (HIL) co-simulation testbed that includes both real-time power system and communication network digital simulators. This paper evaluates the impact of the cyberattacks for different fault scenarios and provides a list of recommendations to improve the reliability of communication-assisted NPU protection.

direct transfer trip↗

Updates of MERRA-2 Data and Services at NASA GES DISC

Over40 years of NASA climate reanalysis datasets from the Modern-Era Retrospective analysis for Research and Applications, Version 2 (MERRA-2) are available at the NASA Goddard Earth Sciences Data and Information Services Center (GES DISC). In addition to being used in traditional weather and climate research, MERRA-2 is also widely used in application studies of, e.g., wind and solar energy, air quality and health, food and drought, and heat waves. Two new MERRA-2 datasets were recently added at the GES DISC: (1) climate statistics derived fromMERRA-2 daily data to assist in the analysis of extreme temperature and precipitation events and of large-scale meteorological patterns from 1980 to the present and (2) gridded satellite and conventional observations processed in the MERRA-2 system, along with key statistics derived from the data assimilation, to help better understand how the quality of observations directly affect there analysis data. The GES DISC focuses its efforts on continually improving existing data services and to develop new data tools to satisfy various user communities. The newly added features include the following: Time series service: This is a new service for MERRA-2 data, which enables the easy and fast access of long-term hourly or daily time series at a location for popular parameters. The data is saved in a single le in Ascii format with a user- friendly structure. New analytic functions in the subsetter interface: Options for downloading daily minimum and maximum values have been added into the subsetter interface, in addition to the existing daily mean option, for all MERRA-2 and MERRA sub-daily products. Data format conversion to GeoTIFF has been implemented. New variables in Giovanni: Most monthly variables have been integrated into Giovanni, GESDISC’s online visualization and analysis tool. Due to the large data volume, hourly variables were selected based on user requests. More online information: New MERRA-2 documentation has been added: Data How-To, Data in Action, and FAQ. This presentation overviews two new MERRA-2 datasets and illustrates the new features of data services through a number of case studies. MERRA-2 data and services can be found at: https://disc.gsfc.gov/datasets?

Data management↗

Interoperability and the Federal Role

A smart grid is capable of integrating a broad array of generation resources and enables the participation of demand side resources in reliable system operation. To cost effectively realize this flexibility, the associated devices and systems need to connect and interact simply and reliably. Interoperability is the important ingredient to make this happen. Because the electric system transcends organizational boundaries between generators, electricity delivery companies, end-users, and other service providers, advancing interoperability between these organizations can be difficult to justify by individual organizations. But given the importance of a smart electric system to meet national economic, societal, and environmental objectives, a federal role is taking shape in the United States to improve the integration of automation elements and thus make smart grid a reality

99 GENERAL AND MISCELLANEOUS↗

Supervised Learning for Distribution Secondary Systems Modeling: Improving Solar Interconnection Processes

The current interconnection process and hosting capacity analysis for distributed energy resources (DERs), such as photovoltaics (PV) and battery energy storage systems, are based on analyzing grid network constraints (voltage and thermal) using only medium-voltage distribution network models. This is because most utilities do not have secondary low-voltage system models that connect service transformers and residential customers. This is important because in many cases the main impact of interconnecting DERs could occur on the low-voltage distribution systems. This paper proposes a supervised learning method to approximate local secondary models to improve the interconnection process. The proposed supervised learning method includes a decision tree model that predicts the secondary topology and a logistic regression model that predicts conductor types. The case studies demonstrate the benefits of including secondary low-voltage circuits in the interconnection process. We report the proposed modeling methodology is readily scalable and thus can reduce the cost and effort of PV interconnection for the industry and stakeholders.

14 SOLAR ENERGY↗

Assessment of Industrial Load for Demand Response across U.S. Regions of the Western Interconnect

Demand response (DR) has the ability to both increase power grid reliability and potentially reduce operating system costs. Understanding the role of demand response in grid modeling has been difficult due to complex nature of the load characteristics compared to the modeled generation and the variation in load types. This is particularly true of industrial loads, where hundreds of different industries exist with varying availability for demand response. We present a framework considering industrial loads for the development of availability profiles that can provide more regional understanding and can be inserted into analysis software for further study. The developed framework utilizes a number of different informational resources, algorithms, and real-world measurements to perform a bottom-up approach in the development of a new database with representation of the potential demand response resource in the industrial sector across the U.S. This tool houses statistical values of energy and demand response (DR) potential by industrial plant and geospatially locates the information for aggregation for different territories without proprietary information. This report will discuss this framework and the analyzed quantities of demand response for Western Interconnect (WI) in support of evaluation of the cost production modeling with power grid modeling efforts of demand response.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity for Electric Vehicle Charging Infrastructure

As the U.S. electrifies the transportation sector, cyberattacks targeting vehicle charging could impact several critical infrastructure sectors including power systems, manufacturing, medical services, and agriculture. This is a growing area of concern as charging stations increase power delivery capabilities and must communicate to authorize charging, sequence the charging process, and manage load (grid operators, vehicles, OEM vendors, charging network operators, etc.). The research challenges are numerous and complicated because there are many end users, stakeholders, and software and equipment vendors interests involved. Poorly implemented electric vehicle supply equipment (EVSE), electric vehicle (EV), or grid operator communication systems could be a significant risk to EV adoption because the political, social, and financial impact of cyberattacks — or public perception of such — would ripple across the industry and produce lasting effects. Unfortunately, there is currently no comprehensive EVSE cybersecurity approach and limited best practices have been adopted by the EV/EVSE industry. There is an incomplete industry understanding of the attack surface, interconnected assets, and unsecured inter faces. Comprehensive cybersecurity recommendations founded on sound research are necessary to secure EV charging infrastructure. This project provided the power, security, and automotive industry with a strong technical basis for securing this infrastructure by developing threat models, determining technology gaps, and identifying or developing effective countermeasures. Specifically, the team created a cybersecurity threat model and performed a technical risk assessment of EVSE assets across multiple manufacturers and vendors, so that automotive, charging, and utility stakeholders could better protect customers, vehicles, and power systems in the face of new cyber threats.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Regulatory and Technical Challenges and Barriers to Adoption of Distributed Wind Energy in Agricultural Settings

Distributed wind (DW) energy development can benefit agricultural landowners through the possibility of improved resilience of electrical service from onsite generation and associated economic benefits. DW development currently faces technical and regulatory challenges related to interconnection of projects with distribution or transmission equipment on the main electrical grid. A review was conducted of barriers to adoption for agricultural DW projects and potential roles of various stakeholders in addressing them. One major barrier is that the unique characteristics of wind energy generation such as its variability and intermittency, may require upgrades for the whole power line, which can lead to prohibitive cost burdens on individual interconnection customers. Another barrier is compliance with federal, state, or utility-level regulations that require technology-agnostic, industry-standard equipment that is often not technically realistic for DW projects. DW developers, grid infrastructure owner-operators, regulators, and standards publishers can work together to address these challenges and facilitate DW development.

17 WIND ENERGY↗

Data Center Market Report

The data center market is poised to explode in the coming decade due to undeniable drivers such as continued adoption of generative AI, increased data storage needs, and enterprise integration of AI in numerous industries [1] [2] [3]. Scalable power and increased computational capacity are at the forefront of considerations for hyperscalers, the major cloud service providers in this space. Lawrence Livermore National Laboratory is uniquely poised to help with informed decision making for data center market leaders during this phase of explosive expansion. National grid modeling expertise and cutting edge innovations in computer cooling systems place LLNL in an enviable position for creating economic impact in the data center industry by leveraging its expertise in these areas which can help the data center market keep up with growing demand.

97 MATHEMATICS AND COMPUTING↗

Operating Characteristics of a 15-cm dia. Ion Engine for Small Planetary Spacecraft

A 15-cm diameter, scaled-down version of the NASA light-weight 30-cm ion engine has been developed for potential application to very small planetary spacecraft. Integration of the 15-cm ion source into 4x15-cm segmented engine configuration results in a 30-cm equivalent engine which can be throttled over a 7-to-1 input power variation with a constant beam current in each of the four segments. Throttling the segmented engine by turning off individual segments can result in a significant decrease in the required service life (and qualification requirements) of the ion source components.

grids segmented ion engine↗