Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Geothermal Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Analysis of Cost Reduction Potential of Vertical Bore Ground Heat Exchanger (Final)

The geothermal heat pump (GHP), also referred to as a ground source heat pump, is a proven technology that can provide space conditioning and water heating with efficiencies higher than conventional heating, ventilation, and air-conditioning (HVAC) systems. This technology possesses great potential to become a mainstream technology for satisfying the thermal demands in the built environment. Analysis from the ongoing Geothermal Vision Study indicates that 100% retrofitting of commercial and residential markets with GHPs has the potential to save on the order of 6 quadrillion Btu per year (Liu et al. 2017). However, the current high installation costs and long payback periods limit the attractiveness of GHP installation in the United States. The cost of installing ground heat exchangers (GHXs) used for GHPs accounts for more than 30% of the total cost of a GHP system (NYSERDA 2017), and it is the biggest contributor to the cost premium of GHPs compared with conventional HVAC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Modular Approach to the Development of Molecular Electrocatalysts for H2 Oxidation and Production Based on Inexpensive Metals

The development of inexpensive electrocatalysts for the production and oxidation of hydrogen will play a vital role in future energy storage and delivery systems. The generation of hydrogen from non-fossil energy sources such as solar, wind, geothermal, and nuclear energy is one approach being considered for storing the electrical energy generated by these sources for transportation and other uses that are not temporally matched to electrical energy production. In the reverse process, in which fuels are used to produce electricity, it is recognized that fuel cells have significant thermodynamic advantages in terms of energy efficiency compared to internal combustion engines and other Carnot processes. Both fuel generation and fuel utilization require electrocatalysts for efficient interconversion of electrical energy and chemical energy. This work was supported by the US Department of Energy Basic Energy Sciences' Chemical Sciences, Geosciences & Biosciences Division. Pacific Northwest National Laboratory is operated by Battelle for the US Department of Energy.

08 HYDROGEN↗

Quillinan, et al 2018 DOE Geothermal Technology Office REE Report for NEWTS Database and Case Studies

Produced water data processed into the NEWTS data format for easy input into aqueous chemistry modeling software, including oil & gas and coal bed methane produced waters, and geothermal waters. Includes information on rare earth elements (REEs) and critical minerals (CMs). Case studies are included to demonstrate solved streams using aqueous chemistry software. An input template is provided for modeling stream data in OLI Studio. Original data from: Quillinan, Scott, Nye, Charles, Engle, Mark, Bartos, Timothy T., Neupane, Ghanashyam, Brant, Jonathan, Bagdonas, Davin, McLing, Travis, McLaughlin, J. Fred, Phillips, Erin, Hallberg, Laura L., Shahabadi, Mahdi, and Johnson, Matthew. Assessing rare earth element concentrations in geothermal and oil and gas produced waters: A potential domestic source of strategic mineral commodities (Final Report). United States: N. p., 2018. Web. doi:10.2172/1509037.

Aqueous Chemistry↗

Grid-Scale, Long-Term Energy Storage: Repurposing Hydrocarbon Reservoirs, Resources, and Infrastructure to Store CO 2 and Heat (Mid-Project Progress Report)

The purpose of this project is to create a viable business case for CO 2 capture, use, and storage (CCUS) by enabling grid-scale, long-term energy storage in mature hydrocarbon reservoirs and saline aquifers. Our CCUS approach, called the Earth Battery, is based on patents issued to Lawrence Livermore National Laboratory on Multi-Fluid Geo-Energy and Earth Battery Systems and to the University of Minnesota and TerraCOH, Inc. on CO 2 Plume Geothermal (CPG). Excess energy can be used to compress and store CO 2 and hot brine underground in permeable formations, including: (1) saline aquifers suitable for geologic CO 2 storage (GCS) and (2) hydrocarbon reservoirs, the focus of this project featuring a pilot test in a mature oil and natural gas (NG) field. Excess energy can come in the form of excess electricity from the grid or excess NG that does not have a market. It can also come in the form of excess heat from other sources, such as from the heat of air or CO 2 compression or from a nearby base-load power plant or solar thermal energy (STE) facility, when heat is not needed to generate electricity from those sources.

15 GEOTHERMAL ENERGY↗

Modeled Performance of the Hathaway Solar Patriot house - Washington D.C

This Dataset contains field research raw data, analysis spreadsheet, photos, and final report from the Hathaway Solar Patriot House Building America Case Study project. This dataset details the monitored and modeled performance of a solar home outside of Washington, D.C. We modeled the home energy performance using DOE 2.2, performed numerous short-terms tests on the home, and monitored its occupied performance for 29 months. The home used modular construction, solar water heating, a ground-coupled heat pump, efficient appliances, and compact fluorescent lighting to reduce its energy consumption by 35% compared to the Building America research benchmark home. The addition of 6kW of photovoltaics (PV) increased the savings to 67% compared to the Building America research benchmark. A more efficient shell to reduce space conditioning loads would have brought the home closer to its zero energy goals. However, even with efficient lighting and appliances, the lights, appliance and plug loads were a significant energy consumer. About 4 kW of PV was required to meet the needs of these loads alone. To achieve the zero energy goal with no further efficiency increases, the Hathaway house would need about 2.6 kW of PV in addition to the 6.0 kW it now has. Applying advanced efficiency measures available or being developed, such as heat-recovery ventilation, superinsulation, and electrochromic windows, could reduce the heating, cooling, and domestic hot water (DHW) energy use to less than 1700 kWh per year, an 88% reduction in these loads from the Building America Benchmark. At this efficiency level, the appliance and plug loads come to dominate energy consumption and account for nearly 70% of the total energy use. This analysis points out that even with highly effective energy-savings technologies (pushed beyond levels currently practical), whole-house energy use reduction by efficiency measures is only about 60% without also reducing the energy use of appliances and plug loads largely considered outside the designers jurisdiction.

Array↗

DIAL Mapping of Atmospheric Atomic Mercury of Geophysical Origin

The atmospheric distribution of atomic mercury is studied with the differential absorption lidar technique using the 253.6 nm Hg resonance line. Using a mobile lidar system employing a Nd:YAG-pumped dye laser, studies were performed in Italian geothermal and mining areas. Concentrations ranging from the background value 2 ng/m(exp 3) to several micro-g/m(exp 3) were measured.

Edner, H.↗

Advancing Geothermal Research: Fiscal Year 2023 Accomplishments Report

Geothermal energy has delivered renewable power for more than 100 years, and renewable heat for far longer, but recent research and advancements have shown that the potential of geothermal is largely untapped. With the ability to provide 24/7 renewable electricity, heating/ cooling, and storage - plus the potential to access critical minerals and more - the Earth's subsurface is a powerhouse ready to be tapped. Investors and leaders across both the public and private sectors are recognizing the unique value of geothermal, and the National Renewable Energy Laboratory (NREL) is leading the way by supporting the U.S. Department of Energy (DOE) Geothermal Technologies Office (GTO) in advancing geothermal energy options today and strategically planning for tomorrow. In support of this objective during fiscal year 2023 (FY23), NREL expanded its collaborations with public and private partners, led impactful research in key technology and energy system areas, demonstrated leadership in the sector, and increased stakeholder engagement and outreach efforts.

annual report↗

Integration of Large-Scale Renewable Energy in the Bulk Power System: Lessons from International Experiences

Deployment of increasing amounts of renewable energy (RE) presents certain challenges in reliably integrating larger quantities RE into existing bulk power system infrastructures. RE Bulk power typically refers to large-scale power generation at a centralized facility and in the context of RE can include wind farms, utility-scale solar, geothermal, hydro and biomass facilities. Based on international experiences, several actions and related good practices have emerged to support the deployment of RE in the bulk power system. This paper provides a review of emerging international best practices that support the integration of large-scale RE; examples of country-level efforts in implementing these practices; and key considerations for any country pursuing bulk power sector transformation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Detectability of geothermal areas using Skylab X-5 data

The results are presented of a study which was undertaken to determine if data from a single near-noon pass of Skylab could be used to detect geothermal areas. The size and temperature requirements for a geothermally heated area to be seen by Skylab S-192 MSS X-5 thermal sensor were calculated. This sensor obtained thermal data with the highest spatial resolution of any nonmilitary satellite system. Only very large hot areas could be expected to be unambiguously recognized with a single data set from this instrument. The study area chosen was The Geysers geothermal field in Sonoma County, California, the only geothermal area of significant size scanned by Skylab. Unfortunately, 95% of the Skylab thermal channel data was acquired within 3 hours of local noon. For The Geysers area only daytime X-5 data were available. An analysis of the thermal channel data (10.2 to 12.5 um) revealed that ground temperatures determined by Skylab were normally distributed. No anomalous hot spots were apparent. Computer enhancement techniques were used to delineate the hottest 100 and 300 ground areas (pixel, 75 m by 75 m) within the study region. It was found that the Skylab MSS with the X-5 thermal detector does not have sufficient spatial resolution to locate unambiguously from daytime data any but the largest and hottest convectively created geothermal features, which in general are prominent enough to have been previously recognized.

Siegal, B. S.↗

Binary Power Plant CO2 Life Cycle Emissions Including Isobutane Fugitive Emission

Geothermal energy production has one of the lowest life cycle CO2 emission factors (~ 15 g-CO2/kWh) for plants producing electricity (Hondo, 2005). This life cycle factor includes indirect emissions from plant construction as well as ongoing operations such as additional well drilling and equipment replacement. Not included in this calculation are direct emissions from geothermal power production. Geothermal flash plants emit CO2 at rates related to the reservoir concentration. Binary plants report “near zero” emissions of high global warming potential gases because of their closed loop system design. Binary plants use working fluids to drive the turbine generators and leakage of these working fluids have not yet been quantified. To assess the working fluid emissions from geothermal power production using an Organic Rankine Cycle, reported isobutane emissions were accessed for 3 California binary plants from the Great Basin Unified and Imperial County Air Pollution Control Districts as well as the California Air Resource Board. Each binary plant used in this study has been operating for more than 25 years. From the data, two types of isobutane emissions were accounted for over a 15 month period: ‘normal’ equipment leakage and equipment breakdown emissions. This preliminary analysis of working fluid emissions from these plants suggest that if a binary plant has equipment failures, the majority of the isobutane releases can be due to these events. The results indicate that a well maintained binary plant releases approximately 0.13 g-Isobutane/kWh where as a plant with equipment failures releases approximately 6 g-Isobutane/kWh. Assuming a greenhouse warming potential of 3 for isobutane, these emission values become 0.4 and 18 g-CO2e/kWh (where CO2e is the CO2 equivalent effect). The direct operation isobutane leakage for a well maintained binary plant does not significant increase the life cycle CO2 emission factor whereas a plant with significant equipment issues can effectively double the life cycle CO2 emissions. This limited data set suggests that when direct CO2e fugitive emission are add to the indirect CO2 emissions, the total CO2 emissions from binary power plants are equivalent or less than nuclear, as well as other renewables power production such as wind and solar.

15 GEOTHERMAL ENERGY↗

Environmental assessment of the proposed nonelectric application of geothermal resources at Desert Hot Springs, California

The paper presents an environmental analysis performed in evaluating various proposed geothermal demonstration projects at Desert Hot Springs. These are categorized in two ways: (1) indirect, or (2) direct uses. Among the former are greenhouses, industrial complexes, and car washes. The latter include aquaculture, a cascaded agribusiness system, and a mobile home park. Major categories of environmental impact covered are: (1) site, (2) construction of projects, and (3) the use of the geothermal source. Attention is also given to the disposal of the geothermal fluid after use. Finally, it is concluded that there are no major problems forseen for each project, and future objectives are discussed.

Rosenberg, L.↗

Compiled Groundwater Chemistry Data and Identified Mineralogy for the Portland Basin CRBG Aquifer System as part of DDU Feasibility Study

Groundwater Chemistry data for the Portland Basin was compiled from published literature, as well as state and federal groundwater quality reports. Mineralogies were identified based on previous literature, as well as XRD and SEM analysis conducted at Portland State University. Uploaded data sets include the compiled data on Portland and Tualatin Basin hydrogeology, and corresponding hydrogeochemical analyses.

15 GEOTHERMAL ENERGY↗

Evaluating geothermal and hydrogeologic controls on regional groundwater temperature distribution

Described is a one-dimensional (1-D) analytic solution is developed for heat transport through an aquifer system where the vertical temperature profile in the aquifer is nearly uniform. The general anisotropic form of the viscous heat generation term is developed for use in groundwater flow simulations. The 1-D solution is extended to more complex geometries by solving the equation for piece-wise linear or uniform properties and boundary conditions. A moderately complex example, the Eastern Snake River Plain (ESRP), is analyzed to demonstrate the use of the analytic solution for identifying important physical processes. For example, it is shown that viscous heating is variably important and that heat conduction to the land surface is a primary control on the distribution of aquifer and spring temperatures. Use of published values for all aquifer and thermal properties results in a reasonable match between simulated and measured groundwater temperatures over most of the 300 km length of the ESRP, except for geothermal heat flow into the base of the aquifer within 20 km of the Yellowstone hotspot. Previous basal heat flow measurements (110 mW/m 2 ) made beneath the ESRP aquifer were collected at distances of > 50 km from the Yellowstone Plateau, but a higher basal heat flow of 150 mW/m 2 is required to match groundwater temperatures near the Plateau. As a result, the ESRP example demonstrates how the new tool can be used during preliminary analysis of a groundwater system, allowing efficient identification of the important physical processes that must be represented during more-complex 2-D and 3-D simulations of combined groundwater and heat flow.

58 GEOSCIENCES↗

University of Illinois Campus Deep Direct-Use Feasibility Study - Preliminary Geothermal Reservoir Model

Preliminary geothermal reservoir simulations were performed using a homogeneous static model to evaluate and understand the effects of fluid and rock properties that could influence the delivery of thermal energy in a doublet system. A 5000 feet by 5100 feet by 500 feet homogeneous model having a constant porosity and permeability of 20% and 100 mD was used to perform preliminary geothermal reservoir simulations. The model was discretized in the x-, y-, and z-directions into 100, 101, and 100, gridblocks. Two wells were placed on the opposite ends of the central column of the discretized model. One of the wells was designated as a producer and the other an injector. Equal volumes of water was extracted and then injected into the reservoir via the production and injection wells. Water was extracted at a temperature of 109 deg F and re-injected at 50 deg F at the 1000 bbl/day. The files attached contains the input and output files of this simulation case. The input and some of the output files can be viewed in any text editor.

15 GEOTHERMAL ENERGY↗

Phase 0 study for a geothermal superheated water proof of concept facility

A Phase 0 study for the selection of a representative liquid-dominated geothermal resource of moderate salinity and temperature is discussed. Selection and conceptual design of a nominal 10-MWe energy conversion system, and implementation planning for Phase 1: subsystem (component, experiments) and Phase 2: final design, construction, and operation of experimental research facilities are reported. The objective of the overall program is to demonstrate the technical and economic viability of utilizing moderate temperature and salinity liquid-dominated resources with acceptable environmental impact, and thus encourage commercial scale development of geothermal electrical power generation.

Douglass, R. H.↗

Case Study of The ARRA-Funded GSHP Demonstration at the Natural Sources Building, Montana Tech

Under the American Recovery and Reinvestment Act (ARRA), 26 ground source heat pump (GSHP) projects were competitively selected in 2009 to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. One of the selected demonstration projects was proposed by Montana Tech of the University of Montana for a 56,000 sq ft, newly constructed, on-campus research facility – the Natural Resources Building (NRB) located in Butte, Montana. This demonstrated GSHP system consists of a 50 ton water-to-water heat pump and a closed-loop ground heat exchanger with two redundant 7.5 hp constant-speed pumps to use water in the nearby flooded mines as a heat source or heat sink. It works in conjunction with the originally installed steam HX and an air-cooled chiller to provide space heating and cooling. It is coupled with the existing hot water and chilled water piping in the building and operates in the heating or cooling mode based on the outdoor air temperature. The ground loop pumps operate in conjunction with the existing pumps in the building hot and chilled water loops for the operation of the heat pump unit. The goal of this demonstration project is to validate the technical and economic feasibility of the demonstrated commercial-scale GSHP system in the region, and illustrate the feasibility of using mine waters as the heat sink and source for GSHP systems. Should the demonstration prove satisfactory and feasible, it will encourage similar GSHP applications using mine water, thus help save energy and reduce carbon emissions. The actual performance of the system is analyzed with available measured data for January through July 2014. The annual energy performance is predicted and compared with a baseline scenario, with the heating and cooling provided by the originally designed systems. The comparison is made in terms of energy savings, operating cost savings, cost-effectiveness, and environmental benefits. Finally, limitations in conducting the analysis are identified and recommendations for improvement in the control and operation of such systems are made.

15 GEOTHERMAL ENERGY↗

Case Study for the ARRA-funded GSHP Demonstration at University at Albany

High initial costs and lack of public awareness of ground-source heat pump (GSHP) technology are the two major barriers preventing rapid deployment of this energy-saving technology in the United States. Under the American Recovery and Reinvestment Act (ARRA), 26 GSHP projects have been competitively selected and carried out to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. This report highlights the findings of a case study of one of the ARRA-funded GSHP demonstration projects—a distributed GSHP system at a new 500-bed apartment-style student residence hall at the University at Albany. This case study is based on the analysis of detailed design documents, measured performance data, published catalog data of heat pump equipment, and actual construction costs. Simulations with a calibrated computer model are performed for both the demonstrated GSHP system and a baseline heating, ventilation, and air-conditioning (HVAC) system to determine the energy savings and other related benefits achieved by the GSHP system. The evaluated performance metrics include the energy efficiency of the heat pump equipment and the overall GSHP system, as well as the pumping performance, energy savings, carbon emission reductions, and cost-effectiveness of the demonstrated GSHP system compared with the baseline HVAC system. This case study also identifies opportunities for improving the operational efficiency of the demonstrated GSHP system.

15 GEOTHERMAL ENERGY↗

Thermally Insulating, Thermal Shock Resistant Calcium Aluminate Phosphate Cement Composites for Reservoir Thermal Energy Storage

This paper presents the use of hydrophobic silica aerogel (HSA) and hydrophilic fly ash cenosphere (FCS) aggregates for improvements in the thermal insulating and mechanical properties of 100- and 250 °C-autoclaved calcium aluminate phosphate (CaP) cement composites reinforced with micro-glass (MGF) and micro-carbon (MCF) fibers for deployment in medium- (100 °C) and high-temperature (250 °C) reservoir thermal energy storage systems. The following six factors were assessed: (1) Hydrothermal stability of HSA; (2) Pozzolanic activity of the two aggregates and MGF in an alkali cement environment; (3) CaP cement slurry heat release during hydration and chemical reactions; (4) Composite phase compositions and phase transitions; (5) Mechanical behavior; (6) Thermal shock (TS) resistance at temperature gradients of 150 and 225 °C. The results showed that hydrophobic trimethylsilyl groups in trimethylsiloxy-linked silica aerogel structure were susceptible to hydrothermal degradation at 250 °C. This degradation was followed by pozzolanic reactions (PR) of HSA, its dissolution, and the formation of a porous microstructure that caused a major loss in the compressive strength of the composites at 250 °C. The pozzolanic activities of FCS and MGF were moderate, and they offered improved interfacial bonding at cement-FCS and cement-MGF joints through a bridging effect by PR products. Despite the PR of MGF, both MGF and MCF played an essential role in minimizing the considerable losses in compressive strength, particularly in toughness, engendered by incorporating weak HSA. As a result, a FCS/HSA ratio of 90/10 in the CaP composite system was identified as the most effective hybrid insulating aggregate composition, with a persistent compressive strength of more than 7 MPa after three TS tests at a 150 °C temperature gradient. This composite displayed thermal conductivity of 0.28 and 0.35 W/mK after TS with 225 and 150 °C thermal gradients, respectively. These values, below the TC of water (TC water = 0.6 W/mK), were measured under water-saturated conditions for applications in underground reservoirs. However, considering the hydrothermal disintegration of HSA at 250 °C, these CaP composites have potential applications for use in thermally insulating, thermal shock-resistant well cement in a mid-temperature range (100 to 175 °C) reservoir thermal energy storage system.

58 GEOSCIENCES↗