Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fermilab”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Fabrication experience of the pre-production PIP-II SSR2 cavities at Fermilab

The Proton Improvement Plan-II (PIP-II, [1]) linac will include 35 Single Spoke Resonators type 2 (SSR2). A total of eight pre-production SSR2 jacketed cavities will be procured and five installed in the first pre-production cryomodule. The mechanical design of the jacketed cavity has been finalized and it will be presented in this paper along with fabrication and processing experience. The importance of interfaces, quality controls and procurement aspects in the design phase will be remarked as well as lessons learned during the fabrication process. Furthermore, development studies will be presented together with other design validation tests.

43 PARTICLE ACCELERATORS↗

Symplectic Particle Tracking in a Thick Nonlinear McMillan Lens for the Fermilab Integrable Optics Test Accelerator (IOTA)

The McMillan system is a novel method to increase the tune spread of a beam without decreasing its dynamic aperture due to the systems integrability. While the ideal system is based on an infinitely thin kick, the physical design requires a thick electron lens, including a solenoid. Particle transport through the lens is difficult to simulate due to the nature of the force on the circulating beam. This paper demonstrates accurate simulation of a thick McMillan lens in a solenoid using symplectic integrators derived from Yoshidas method.

43 PARTICLE ACCELERATORS↗

Beamline Volume Relief Analysis for the PIP-II SSR2 Cryomodule at Fermilab

The beam volume of the Pre-Production Single Spoke Resonator type 2 (ppSSR2) cryomodule [1] for the Proton Improvement Plan-II (PIP-II) [2] project will be protected against over-pressurization using a burst disk. This contribution focuses on the analysis of the relief of such trapped volume during a catastrophic scenario with multiple systems failures. An analytical model, able to predict the pressure in the beam volume depending of the various boundary conditions, has been developed and will be presented along with the results.

43 PARTICLE ACCELERATORS↗

A Vector Control and Data Acquisition System for the Multicavity LLRF System for Cryomodule1 at Fermilab

A LLRF control and data acquisition system for the 8-cavity Cryo-Module 1 at the ILCTA has been implemented using three , 33-channel MFC boards in a VXI mainframe. One card each is dedicated for the cavity probes for vector control , forward power and reverse power measurements. The system is scalable to 24 cavities or more with the commissioning of Cryo-Modules 2 and 3 without additional hardware. The signal processing and vector control of the cavities is implemented in a FPGA and a high speed data acquisition system with upto 100 channels stores data in external SDRAM memory. The system supports both pulsed and CW modes with a pulse rate of 5Hz. Acquired data is transferred between pulses to auxiliary systems such as the piezo controller through the slot0 controller. The design of the system is described and the performance of the vector control system is evaluated.

43 PARTICLE ACCELERATORS↗

A Schottky Tune Meter for the Fermilab Mu2E Delivery Ring

The Mu2E experiment will measure the ratio of the rate of the neutrinoless, coherent conversion of muons into electrons as a measure of Charged Lepton Flavor Violation. As part of the Mu2E experiment, a proton storage ring, called the Delivery Ring, will utilize resonant extraction to slow-spill protons to the experiment. To regulate and optimize the Delivery Ring resonant extraction process, a fast tune measurement scheme will be required. This Mu2E tune meter will measure the average tune and the tune spectrum, in multiple time slices, through the entire resonant extraction cycle of nominally 43 msec. The Mu2E tune meter system utilizes vertical and horizontal 21.4 MHz Schottky detector resonant pickups, taken from the decommissioned Tevatron, high-gain amplifiers and digital down-conversion FPGA logic for its signal processing. This paper will present the design of this Schottky tune meter as well as tune measurements from the Mu2E delivery ring.

43 PARTICLE ACCELERATORS↗

Software and Firmware-logic Design for the PIP-II Machine Protection System Mode and Configuration Control at Fermilab

The PIP-II Machine Protection System (MPS) requires a dedicated set of tools for configuration control and management of the machine modes and beam modes of the accelerator. The protection system reacts to signals from various elements of the machine according to rules established in a setup database in the form of a Look-Up-Table filtered by the program Mode Controller. This is achieved in accordance with commands from the operator and governed by the firmware logic of the MPS. This paper describes the architecture, firmware logic, and implementation of the program mode controller.

43 PARTICLE ACCELERATORS↗

Target Multiwire for the Fermilab Booster Neutrino Beamline

The Booster Neutrino Beamline experiment re-quested a new secondary electron emission multiwire profile monitor installation. The device had to be durable in high radiation conditions and mounted within a large 10-foot airtight steel fixture for installation near the beam target. Previous iterations of multiwire suffered radiation damage to both the connectors and wires. To ensure accurate horizontal and vertical beam profile measurements, an updated design was pro-posed, designed, and constructed. The new BNB multiwire utilizes 3 mil diameter gold-plated tungsten sense wires soldered to vertical and horizontal Alumi-na-96 ceramic planes, 50 wires per plane. Radiation hard Kapton insulated 30-gauge wires carry the output signals. Profiles are readout through charge integrator scanner electronics. This paper will detail the design and functionality of the BNB target multiwire and present relevant beam profile data.

43 PARTICLE ACCELERATORS↗

Overview of collaborative research between UNICAMP in Brazil and Fermilab in cryogenics

The Long-Baseline Neutrino Facility (LBNF) situated at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, serves as the host for the Deep Underground Neutrino Experiment (DUNE), employing cryostats with nearly 70,000 metric tons of high purity liquid argon (LAr). The integrity of LAr quality is pivotal in determining the electron lifetime within DUNE, directly impacting its signal-to-noise ratio. Specifically, Far Detector 1 (FD-1) in cryostat 1 requires an electron lifetime over 3 ms within its 3.5 m drift, corresponding to less than 100 parts-per-trillion (ppt) Oxygen equivalent contamination. Far Detector 2 (FD-2) in cryostat 2 demands over 6 ms electron lifetime within its 6.0 m drift, corresponding to less than 50 ppt Oxygen equivalent contamination. Nitrogen (N$_2$) absorption of LAr scintillation light, known as quenching, necessitates N$_2$ contamination in LAr to remain below 1 ppm to minimize photon loss and enhance energy reconstruction. Studies indicate that at 1 ppm N$_2$, approximately 20% of scintillation light is lost, highlighting the importance of minimizing N$_2$ contamination.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fermilab Booster Beam Emittances from Quadrupole Modes Measured by BPMs

The measurement of beam emittances by extracting the quadrupole mode signal from a 4 plate beam position monitor (BPM) was published at least 40 years ago. Unfortunately, in practice, this method suffers from poor signal to noise ratio and requires a lot of tuning to extract out the emittances. In this paper, an improved method where multiple BPMs are used together with better mathematical analysis is described. The BPM derived emittances are then compared with those measured by the Ion Profile Monitor (IPM). Surprisingly, the BPM measured emittances behave very well and are more realistic than those measured by the IPM.

43 PARTICLE ACCELERATORS↗

LAr1-ND: Testing Neutrino Anomalies with Multiple LArTPC Detectors at Fermilab

This white paper describes LAr1-ND and the compelling physics it brings first in Phase 1 and next towards the full LAr1 program. In addition, LAr1-ND serves as a key step in the development toward large-scale LArTPC detectors. Its development goals will encompass testing existing and possibly innovative designs for LBNE while at the same time providing a training ground for teams working towards LBNE combining timely neutrino physics with experience in detector development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗