Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FILES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Binary Analysis with Architecture and Code Section Detection using Supervised Machine Learning

When presented with an unknown binary, which may or may not be complete, having the ability to determine information about it is critical to future reverse engineering, particularly in discovering the binary’s intended use and potentially malicious nature. This paper details techniques to both identify the machine architecture of the binary, as well as to locate the important code segments within the file. This identification of unknown binaries makes use of a technique called byte histogram in addition to various machine learning (ML) techniques, which we call “What is it Binary” or WiiBin. Benefits of byte histograms reflect the simplicity of calculation and do not rely on file headers or metadata, allowing for acceptable results when only a small portion of the original file is available. Utilizing WiiBin, we were able to accurately (>80%) determine the architecture of test binaries with as little as a 20% contagious portion of the file present. We were also able to determine the location of code sections within a binary by utilizing the WiiBin framework. Ultimately, the more information that can be gleaned from a binary file, the easier it is to successfully reverse engineer.

99 GENERAL AND MISCELLANEOUS↗

Dynamic Virtual Chunks: On Supporting Efficient Accesses to Compressed Scientific Data

Data compression could ameliorate the I/O pressure of data-intensive scientific applications. Unfortunately, the conventional wisdom of naively applying data compression to the file or block brings the dilemma between efficient random accesses and high compression ratios. File-level compression barely supports efficient random accesses to the compressed data: any retrieval request need trigger the decompression from the beginning of the compressed file. Block-level compression provides flexible random accesses to the compressed blocks, but introduces extra overhead when applying the compressor to each and every block that results in a degraded overall compression ratio. This paper extends our prior work that introduces virtual chunks offering efficient random accesses to the compressed scientific data without sacrificing the compression ratio. Virtual chunks are logical blocks pointed at by appended references without breaking the physical continuity of the file content. These references allow the decompression to start from an arbitrary position (efficient random accesses), while no per-block overhead is introduced because the file’s physical entirety is retained (high compression ratio). One limitation of virtual chunk is it only supports static references. This paper presents the algorithms, analysis, and evaluations of dynamic virtual chunks to deal with the cases where the references are updated dynamically.

I/O compression performance optimization↗

SU-D-BRD-07: Automatic Patient Data Audit and Plan Quality Check to Support ARIA and Eclipse

Purpose: To ensure patient safety and treatment quality in RT departments that use Varian ARIA and Eclipse, we developed a computer software system and interface functions that allow previously developed electron chart checking (EcCk) methodologies to support these Varian systems. Methods: ARIA and Eclipse store most patient information in its MSSQL database. We studied the contents in the hundreds database tables and identified the data elements used for patient treatment management and treatment planning. Interface functions were developed in both c-sharp and MATLAB to support data access from ARIA and Eclipse servers using SQL queries. These functions and additional data processing functions allowed the existing rules and logics from EcCk to support ARIA and Eclipse. Dose and structure information are important for plan quality check, however they are not stored in the MSSQL database but as files in Varian private formats, and cannot be processed by external programs. We have therefore implemented a service program, which uses the DB Daemon and File Daemon services on ARIA server to automatically and seamlessly retrieve dose and structure data as DICOM files. This service was designed to 1) consistently monitor the data access requests from EcCk programs, 2) translate the requests for ARIA daemon services to obtain dose and structure DICOM files, and 3) monitor the process and return the obtained DICOM files back to EcCk programs for plan quality check purposes. Results: EcCk, which was previously designed to only support MOSAIQ TMS and Pinnacle TPS, can now support Varian ARIA and Eclipse. The new EcCk software has been tested and worked well in physics new start plan check, IMRT plan integrity and plan quality checks. Conclusion: Methods and computer programs have been implemented to allow EcCk to support Varian ARIA and Eclipse systems. This project was supported by a research grant from Varian Medical System.

60 APPLIED LIFE SCIENCES↗

SU-E-T-253: Development of a GDPM Monte Carlo Based Quality Assurance Tool for Cyberknife

Purpose: To develop a 3D quality assurance (QA) tool for Cyberknife plans using a GPU-based Monte Carlo dose calculation package, gDPM. The developed QA tool will be used as a secondary check for Cyberknife treatment planning software (TPS) reported dose distributions. Methods: Phase space files of the 5, 7.5, 10, 15, and 60 mm iris cones were downloaded from IAEA phase-space database. From the 60mm iris cone phase space file, we were able to generate raw phase space files for all other cones using a particle rejection method. The particles in the raw phase space files were binned with respect to the radial position and energy for commissioning. During the commissioning process, gDPM calculated percent depth dose and off-center ratios which were compared to those measured in the Blue Phantom. The off-axis data was measured with an SAD setup at depths of 15, 50, 100, 200, and 300 mm. At the commissioning stage, an optimization problem was solved to adjust the binned particles weights to minimize the difference between the calculated and measured ones. Commissioning validations will be performed by measuring point dose data of patient specific plans delivered to water phantoms. With commissioned phase space files, 3D patient-specific dose distributions will be calculated and compared against TPS reported dose. Results: Beyond the initial buildup region, the root mean square difference between the calculated and measured percent depth dose differences was less than 0.5%. The full-width half-max data from the off-axis ratio calculations was found to be within 0.1 mm of the measured data. Conclusion: Our current work showed excellent agreement between the gDPM calculated dose and the measured data for all cone sizes and types for the Cyberknife system. Implementation of a fast and accurate QA tool for patient specific plans will be feasible with this tool.

60 APPLIED LIFE SCIENCES↗

MO-F-CAMPUS-I-01: A System for Automatically Calculating Organ and Effective Dose for Fluoroscopically-Guided Procedures

Purpose: A system was developed that automatically calculates the organ and effective dose for individual fluoroscopically-guided procedures using a log of the clinical exposure parameters. Methods: We have previously developed a dose tracking system (DTS) to provide a real-time color-coded 3D- mapping of skin dose. This software produces a log file of all geometry and exposure parameters for every x-ray pulse during a procedure. The data in the log files is input into PCXMC, a Monte Carlo program that calculates organ and effective dose for projections and exposure parameters set by the user. We developed a MATLAB program to read data from the log files produced by the DTS and to automatically generate the definition files in the format used by PCXMC. The processing is done at the end of a procedure after all exposures are completed. Since there are thousands of exposure pulses with various parameters for fluoroscopy, DA and DSA and at various projections, the data for exposures with similar parameters is grouped prior to entry into PCXMC to reduce the number of Monte Carlo calculations that need to be performed. Results: The software developed automatically transfers data from the DTS log file to PCXMC and runs the program for each grouping of exposure pulses. When the dose from all exposure events are calculated, the doses for each organ and all effective doses are summed to obtain procedure totals. For a complicated interventional procedure, the calculations can be completed on a PC without manual intervention in less than 30 minutes depending on the level of data grouping. Conclusion: This system allows organ dose to be calculated for individual procedures for every patient without tedious calculations or data entry so that estimates of stochastic risk can be obtained in addition to the deterministic risk estimate provided by the DTS. Partial support from NIH grant R01EB002873 and Toshiba Medical Systems Corp.

60 APPLIED LIFE SCIENCES↗

TU-CD-304-11: Veritas 2.0: A Cloud-Based Tool to Facilitate Research and Innovation

Purpose: We introduce Veritas 2.0, a cloud-based, non-clinical research portal, to facilitate translation of radiotherapy research ideas to new delivery techniques. The ecosystem of research tools includes web apps for a research beam builder for TrueBeam Developer Mode, an image reader for compressed and uncompressed XIM files, and a trajectory log file based QA/beam delivery analyzer. Methods: The research beam builder can generate TrueBeam readable XML file either from scratch or from pre-existing DICOM-RT plans. DICOM-RT plan is first converted to XML format and then researcher can interactively modify or add control points to them. Delivered beam can be verified via reading generated images and analyzing trajectory log files. Image reader can read both uncompressed and HND-compressed XIM images. The trajectory log analyzer lets researchers plot expected vs. actual values and deviations among 30 mechanical axes. The analyzer gives an animated view of MLC patterns for the beam delivery. Veritas 2.0 is freely available and its advantages versus standalone software are i) No software installation or maintenance needed, ii) easy accessibility across all devices iii) seamless upgrades and iv) OS independence. Veritas is written using open-source tools like twitter bootstrap, jQuery, flask, and Python-based modules. Results: In the first experiment, an anonymized 7-beam DICOM-RT IMRT plan was converted to XML beam containing 1400 control points. kV and MV imaging points were inserted into this XML beam. In another experiment, a binary log file was analyzed to compare actual vs expected values and deviations among axes. Conclusions: Veritas 2.0 is a public cloud-based web app that hosts a pool of research tools for facilitating research from conceptualization to verification. It is aimed at providing a platform for facilitating research and collaboration. I am full time employee at Varian Medical systems, Palo Alto.

60 APPLIED LIFE SCIENCES↗

SU-F-T-177: Impacts of Gantry Angle Dependent Scanning Beam Properties for Proton Treatment

Purpose: In pencil beam scanning (PBS), the delivered spot MU, position and size are slightly different at different gantry angles. We investigated the level of delivery uncertainty at different gantry angles through a log file analysis. Methods: 34 PBS fields covering full 360 degrees gantry angle spread were collected retrospectively from 28 patients treated at our institution. All fields were delivered at zero gantry angle and the prescribed gantry angle, and measured at isocenter with the MatriXX 2D array detector at the prescribed gantry angle. The machine log files were analyzed to extract the delivered MU per spot and the beam position from the strip ionization chambers in the treatment nozzle. The beam size was separately measured as a function of gantry angle and beam energy. Using this information, the dose was calculated in a water phantom at both gantry angles and compared to the measurement using the 3D γ-index at 2mm/2%. Results: The spot-by-spot difference between the beam position in the log files from the delivery at the two gantry angles has a mean of 0.3 and 0.4 mm and a standard deviation of 0.6 and 0.7 mm for × and y directions, respectively. Similarly, the spot-by-spot difference between the MU in the log files from the delivery at the two gantry angles has a mean 0.01% and a standard deviation of 0.7%. These small deviations lead to an excellent agreement in dose calculations with an average γ pass rate for all fields being approximately 99.7%. When each calculation is compared to the measurement, a high correlation in γ was also found. Conclusion: Using machine logs files, we verified that PBS beam delivery at different gantry angles are sufficiently small and the planned spot position and MU. This study brings us one step closer to simplifying our patient-specific QA.

60 APPLIED LIFE SCIENCES↗

SU-F-T-302: Implementation of the RadCalc Image Analysis Tool for IMRT QA

Purpose: To assess RadCalc as a means for analyzing fluence maps of IMRT QA patient plans. Eclipse generated fluence maps were compared to RadCalc fluence maps generated from both Eclipse parameters and from dynalog trajectory files. Methods: Six IMRT plans consisting of fifty individual fields were compared both field-by-field and as composite plans. These plans were exported from Eclipse to RadCalc. Each plan was then delivered in QA mode on a Varian Clinac iX, while recording and saving the dynalog trajectory files. These files were then imported into RadCalc, providing three sources of generating fluence maps: Eclipse, RadCalc, and dynalog files. Using the image analysis tool in RadCalc, a gamma analysis was then performed as a point-by-point comparison for each IMRT field. The Eclipse fluence map was used as the baseline for each comparison. Results: Based on the manufacturer’s recommendations, all fields were normalized to the maximum pixel value within each Eclipse field. All data was analyzed using a gamma index of 3mm/3% with passing criteria of 90%. For both dynalog analysis and RadCalc fluence analysis, 48/50 created fluence maps passed at greater than 90% when compared with the Eclipse baseline. In analyzing the composite of each of the six patients’ plans, all plans passed over 90%. Conclusion: Using the dynalog trajectory files in combination with RadCalc Version 6.3 image analysis is a promising metric for verifying IMRT QA passing rates. Notably, if a field failed, it did so for both dynalog and RadCalc compared to Eclipse. This suggests RadCalc can accurately simulate fluence maps, with similar results to dynalog comparisons. Limitations within the RadCalc software were discovered in the analytical process such as pixel resolution and the inability to set minimum threshold values. Comparisons could be extended to include dose map and distance to agreement analysis by expanding software capabilities.

60 APPLIED LIFE SCIENCES↗

SU-F-T-469: A Clinically Observed Discrepancy Between Image-Based and Log- Based MLC Position

Purpose: To present a clinical case which challenges the base assumption of log-file based QA, by showing that the actual position of a MLC leaf can suddenly deviate from its programmed and logged position by >1 mm as observed with real-time imaging. Methods: An EPID-based exit-fluence dosimetry system designed to prevent gross delivery errors was used in cine mode to capture portal images during treatment. Visual monitoring identified an anomalous MLC leaf pair gap not otherwise detected by the automatic position verification. The position of the erred leaf was measured on EPID images and log files were analyzed for the treatment in question, the prior day’s treatment, and for daily MLC test patterns acquired on those treatment days. Additional standard test patterns were used to quantify the leaf position. Results: Whereas the log file reported no difference between planned and recorded positions, image-based measurements showed the leaf to be 1.3±0.1 mm medial from the planned position. This offset was confirmed with the test pattern irradiations. Conclusion: It has been clinically observed that log-file derived leaf positions can differ from their actual positions by >1 mm, and therefore cannot be considered to be the actual leaf positions. This cautions the use of log-based methods for MLC or patient quality assurance without independent confirmation of log integrity. Frequent verification of MLC positions through independent means is a necessary precondition to trusting log file records. Intra-treatment EPID imaging provides a method to capture departures from MLC planned positions. Work was supported in part by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Comparative I/O workload characterization of two leadership class storage clusters. In: PDSW '15 Proceedings of the 10th Parallel Data Storage Workshop

The Oak Ridge Leadership Computing Facility (OLCF) is a leader in large-scale parallel file system development, design, deployment and continuous operation. For the last decade, the OLCF has designed and deployed two large center-wide parallel file systems. The first instantiation, Spider 1, served the Jaguar supercomputer and its predecessor, Spider 2, now serves the Titan supercomputer, among many other OLCF computational resources. The OLCF has been rigorously collecting file and storage system statistics from these Spider systems since their transition to production state. In this paper we present the collected I/O workload statistics from the Spider 2 system and compare it to the Spider 1 data. Our analysis show that the Spider 2 workload is more more write-heavy I/O compared to Spider 1 (75% vs. 60%, respectively). The data also show the OLCF storage policies such as periodic purges are effectively managing the capacity resource of Spider 2. Furthermore, due to improvements in tdm_multipath and ib_srp software, we are utilizing the Spider 2 system bandwidth and latency resources more effectively. The Spider 2 bandwidth usage statistics shows that our system is working within the design specifications. However, it is also evident that our scientific applications can be more effectively served by a burst buffer storage layer. All the data has been collected by monitoring tools developed for the Spider ecosystem. We believe the observed data set and insights will help us better design the next-generation Spider file and storage system. It will also be helpful to the larger community for building more effective large-scale file and storage systems.

Gunasekaran, Raghul↗

Supplemental material for paper "Radiosonde-to-Space (R2S) atmospheric specifications: Bridging observations and models for infrasound propagation"

This document describes the supplemental materials for the paper: TITLE: "Radiosonde-to-Space (R2S) atmospheric specifications: Bridging observations and models for infrasound propagation" DOI: xxxxxxxxxxx JOURNAL: TBD Written by Loring Schaible, September 17, 2025 This folder contains eight subfolders, each for a specific date and UTC time (in format YYYY-MM-DD_HH). All eight of these dates are exemplified and described in the manuscript. Within each folder is six documents. As an example, consider the folder "2022-12-31_00". The six files are comprised of: - Two text files (extension .txt) that describe the atmospheric specifications of Albuquerque, NM. One is the G2S model, the other is the R2S model. "G2S_2022-12-31_00.txt" "R2S_2022-12-31_00.txt" - Two text files (extension .dat) that contain the ground arrivals predicted by infraGA using the parameters described in the manuscript. One each for the two atmospheric specification models above, G2S and R2S. "G2S_2022-12-31_00.arrivals.dat" "R2S_2022-12-31_00.arrivals.dat" - Two image files (extension .png) that illustrate the predicted arrivals contained in the two files above. One image shows all arrivals as either black (G2S) or red (R2S). The other image shows the same but with arrivals common to both models in gray. "2022-12-31_00_Arrivals.png" "2022-12-31_00_DifArrivals.png"

Schaible, Loring Pratt [Sandia National Laboratori↗

Checkpoint-Restart in User Space

CRUISE implements a user-space file system that stores data in main memory and transparently spills over to other storage, like local flash memory or the parallel file system, as needed. CRUISE also exposes file contents fo remote direct memory access, allowing external tools to copy files to the parallel file system in the background with reduced CPU interruption.

Source record↗

ThermoPhonon

ThermoPhonon is a stand-alone code, which can be integrated into other software packages. Typically, it is used together with a density functional theory (DFT) code (such as VASP, Wien2k, AbInit, SIESTA) and a phonon code (such as Phonopy or Phon). The workflow is the following. Molecular dynamics (MD) in a supercell at a given temperature T is performed using another code. After sufficient equilibration, the output in the form of atomic positions and forces for a large number of selected MD steps is recorded into a file. If needed, one can modify this file by applying additional constraints, such as enforced crystal symmetry or subtracted motion of the center of mass. ThermoPhonon reads the file with atomic positions and forces and writes a new file with the force constants. Force constants can be used by another code (such as Phonopy or Phon) to produce phonon spectrum for plotting, in the assumption of known equilibrium atomic positions provided in a separate file.

Zarkevich, Nikolai↗

DMS Instrument Directory Scanner

This program examines the source folder on instrument computers to find files and folders. It creates a tab-delimited text file for each instrument, listing the names of the files and folders found. The text files for the instruments are stored in a central location, and are made made visible via the DMS website to allow instrument operators to see the instrument data files on the instrument computer.

Monroe, Matthew↗

DMS Update Manager

The DMS Update Manager is used to keep automated processing manager software up-to-date. Although it is part of PRISM (the Proteomics Research Information and Management System), it is a standalone program and does not contact any databases. The program compares the files on a central distribution share to files on the local computer, updating any files that are out of date. It supports rolling back local files to an older version and auto-deleting extra files.

Monroe, Matthew↗

Data Import Manager

The Data Import Manager is a part of PRISM, the Proteomics Research Information and Management System. The Data Import Manager monitors a central folder for new dataset trigger files, which are XML files that specify metadata for new datasets to import into the Data Management System (DMS). The Data Import Manager validates the metadata in the XML trigger file, notifying the instrument operator by e-mail if invalid metadata is encountered. After processing each XML trigger file, the file is moved into either a success or failure folder.

Monroe, Matthew↗

BESTEST-GSR (Building Energy Simulation Test - Generation Simulation and Reporting) [SWR 18-23]

Building Energy Simulation Test (BESTEST) is an NREL-developed method to validate the qualitative performance of different whole building simulations engines relative to each other. https://www.nrel.gov/docs/legosti/old/6231.pdf For EnergyPlus® and OpenStudio®, generation of test cases, simulation, and reporting has been a manual or partially automated process that typically took a number of months after a new version of EnergyPlus came out. Building Energy Simulation Test - Generation Simulation and Reporting (BESTEST-GSR) was developed to fully automate this process so it is less error-prone, less time-consuming, and can be quickly run on request for any development branch of EnergyPlus and OpenStudio. The initial use case is to directly support OpenStudio and EnergyPlus development, but the software is configured to support use by external software developers that build tools on top of EnergyPlus and/or OpenStudio. Tools built on top of OpenStudio can leverage the test generation, simulation, and reporting, while tools built on EnergyPlus can leverage the test simulation and reporting. The model generation is accomplished by running OpenStudio measures for envelope, heating, or cooling test cases. At this stage the specified weather file required for a specific test case is assigned to the model. Simulation is enabled using the OpenStudio Command Line Interface (CLI) to run a series of OpenStudio and Reporting measures to a specified seed model. The specified workflow is defined with an OpenStudio OSW file. The first measure generates the test case model, while the second measure is a reporting measure that runs after the simulation to collect necessary simulation results from the EnergyPlus SQL file. The Reporting stage gathers data from individual OpenStudio OSW files and populates a series of BESTEST Microsoft Excel spreadsheets. BESTEST-GSR also gathers zip files from individual simulations for diagnostic purposes.

Goldwasser, David↗