Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FEDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Planck 2015 results: XI. CMB power spectra, likelihoods, and robustness of parameters

This study presents the Planck 2015 likelihoods, statistical descriptions of the 2-point correlationfunctions of the cosmic microwave background (CMB) temperature and polarization fluctuations that account for relevant uncertainties, both instrumental and astrophysical in nature. They are based on the same hybrid approach used for the previous release, i.e., a pixel-based likelihood at low multipoles (ℓ< 30) and a Gaussian approximation to the distribution of cross-power spectra at higher multipoles. The main improvements are the use of more and better processed data and of Planck polarization information, along with more detailed models of foregrounds and instrumental uncertainties. The increased redundancy brought by more than doubling the amount of data analysed enables further consistency checks and enhanced immunity to systematic effects. It also improves the constraining power of Planck, in particular with regard to small-scale foreground properties. Progress in the modelling of foreground emission enables the retention of a larger fraction of the sky to determine the properties of the CMB, which also contributes to the enhanced precision of the spectra. Improvements in data processing and instrumental modelling further reduce uncertainties. Extensive tests establish the robustness and accuracy of the likelihood results, from temperature alone, from polarization alone, and from their combination. For temperature, we also perform a full likelihood analysis of realistic end-to-end simulations of the instrumental response to the sky, which were fed into the actual data processing pipeline; this does not reveal biases from residual low-level instrumental systematics. Even with the increase in precision and robustness, the ΛCDM cosmological model continues to offer a very good fit to the Planck data. The slope of the primordial scalar fluctuations, n s , is confirmed smaller than unity at more than 5σ from Planck alone. We further validate the robustness of the likelihood results against specific extensions to the baseline cosmology, which are particularly sensitive to data at high multipoles. For instance, the effective number of neutrino species remains compatible with the canonical value of 3.046. For this first detailed analysis of Planck polarization spectra, we concentrate at high multipoles on the E modes, leaving the analysis of the weaker B modes to future work. At low multipoles we use temperature maps at all Planck frequencies along with a subset of polarization data. These data take advantage of Planck’s wide frequency coverage to improve the separation of CMB and foreground emission. Within the baseline ΛCDM cosmology this requires τ = 0.078 ± 0.019 for the reionization optical depth, which is significantly lower than estimates without the use of high-frequency data for explicit monitoring of dust emission. At high multipoles we detect residual systematic errors in E polarization, typically at the μK 2 level; we therefore choose to retain temperature information alone for high multipoles as the recommended baseline, in particular for testing non-minimal models. Finally and nevertheless, the high-multipole polarization spectra from Planck are already good enough to enable a separate high-precision determination of the parameters of the ΛCDM model, showing consistency with those established independently from temperature information alone.

79 ASTRONOMY AND ASTROPHYSICS↗

Star formation in outer rings of S0 galaxies: IV. NGC 254: A double-ringed S0 with gas counter-rotation

Although S0 galaxies are usually considered “red and dead”, they often demonstrate star formation organized into ring structures. We aim to clarify the nature of this phenomenon and how it differs from star formation in spiral galaxies. We investigated the nearby, moderate-luminosity S0 galaxy NGC 254 using long-slit spectroscopy taken with the South African Large Telescope and publicly available imaging data. Applying a full spectral fitting, we analyzed gaseous and stellar kinematics as well as ionized gas excitation and metallicity and stellar population properties resolved by radius. An advanced approach of simultaneously fitting spectra and photometric data allowed us to quantify the fraction of hidden counter-rotating stars in this galaxy. We find that the ionized gas is counter-rotating with respect to the stars throughout NGC 254 disk, indicating an external origin of the gas. We argue the gas-rich galaxy merger from retrograde orbit as a main source of counter-rotating material. The star formation fed by this counter-rotating gas occurs within two rings: an outer ring at R = 55' - 70" and an inner ring at R = 18". The star formation rate is weak, 0.02 solar mass per year in total, and the gas metallicity is slightly subsolar. We estimated that the accretion of the gas occurred about 1 Gyr ago, and about 1% of all stars have formed in situ from counter-rotating gas.

79 ASTRONOMY AND ASTROPHYSICS↗

Summary: Gas Targets and Ion Sources

The talks related to gas targets and ion sources are summarized. The main areas of interest were hydrogen and deuterium gas targets for storage rings, fed by atomic beam sources, and pulsed ion sources for injection into synchrotrons, both for the hydrogen isotopes and for fully stripped {sup 3}He. Impressive progress has been achieved in the last few years.

43 PARTICLE ACCELERATORS↗

Retarding field analyzer for ion energy distribution measurements at a radio-frequency biased electrode

A retarding field energy analyzer designed to measure ion energy distributions impacting a radio-frequency biased electrode in a plasma discharge is examined. The analyzer is compact so that the need for differential pumping is avoided. The analyzer is designed to sit on the electrode surface, in place of the substrate, and the signal cables are fed out through the reactor side port. This prevents the need for modifications to the rf electrode--as is normally the case for analyzers built into such electrodes. The capabilities of the analyzer are demonstrated through experiments with various electrode bias conditions in an inductively coupled plasma reactor. The electrode is initially grounded and the measured distributions are validated with the Langmuir probe measurements of the plasma potential. Ion energy distributions are then given for various rf bias voltage levels, discharge pressures, rf bias frequencies - 500 kHz to 30 MHz, and rf bias waveforms - sinusoidal, square, and dual frequency.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plasma Lens for a US Based Super Neutrino Beam

The plasma lens concept is examined as an alternative to focusing horns and solenoids for a neutrino beam facility. The concept is based on a combined high-current lens/target configuration. Current is fed at an electrode located downstream from the beginning of the target where pion capturing is needed. The current is carried by plasma outside the target. A second plasma lens section, with an additional current feed, follows the target. The plasma is immersed in a solenoidal magnetic field to facilitate its current profile shaping to optimize pion capture. Simulations of the not yet fully optimized configuration yielded a 25% higher neutrino flux at a detector situated at 3 km from the target than the horn system for the entire enegry spectrum and a factor of 2.47 higher flux for neutrinos with energy larger than 3 GeV. A major advantage of plasma lenses is in background reduction. In anti-neutrino operation, neutrino background is reduced by a factor of close to 3 for the whole spectrum, and for and for energy larger than 3 GeV; neutrino background is reduced by a factor of 3.6. Plasma lens advantages are due to: larger axial currents, high signal purity: minimal neutrino background in anti-neutrino runs. Additionally the lens medium consists of plasma, consequently, particle absorption and scattering is negligible. Withstanding high mechanical and thermal stresses in a plasma is not an issue.

43 PARTICLE ACCELERATORS↗

Operating regimes of corona and silent discharges in coaxial cylindrical reactors

The physical mechanisms of the electrical discharges formed in coaxial cylindrical reactors have been investigated in this paper under different operating conditions for the reactors. The reactors were fed by natural air flowing with a constant rate at atmospheric conditions and stressed by an ac voltage. The wave form of the ac voltage applied to the reactors has been studied corresponding to the discharge current, over the whole range of the operating conditions. The results have shown that the operating conditions for the reactor modify the physical mechanism inside it in the form of either corona or silent discharges or spark over. The onset voltage of the different electrical discharges formed inside the reactors has agreed with Peek's equation, whatever the operating conditions. Subsequently, empirical equations concerning the operating conditions for the reactors have been derived by using Peek's and Townsend's equations. The derived equations represent suitable criterions to predict the different types of the electrical discharges that will form inside the reactors under any operating conditions. The results have been illustrated by recorded oscillograms showing the wave form of the ac voltage applied to the reactors and the corresponding current pulses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of Fast Measurement System of Neutron Emission Profile Using a Digital Signal Processing Technique in JT-60U

Neutron emission profiles are routinely measured in JT-60U Tokamak. Stinbene neuron detectors (SNDs), which combine a Stilbene organic crystal scintillation detector (Stilbene detector) with an analog neutron-gamma pulse shape discrimination (PSD) circuit, have been used to measure neutron flux efficiently. Although the SND has many advantages as a neutron detector, the maximum count rate is limited up to {approx}1x 10{sup 5} counts/s due to the dead time of the analog PSD circuit. To overcome this issue, a digital signal processing (DSP) system using a Flash-ADC has been developed. In this system, anode signals from the photomultiplier of the Stilbene detector are fed to the Flash ADC and digitized. Then, the PSD between neutrons and gamma-rays are performed using software. The photomultiplier tube is also modified to suppress and correct gain fluctuation of the photomultiplier. The DSP system has been installed in the center channel of the vertical neutron collimator system in JT-60U and applied to measurements of neutron flux in JT-60U experiments. Neutron flux are successfully measured with count rate up to {approx}1x 10{sup 6} counts/s without the effect of pile up of detected pulses. The performance of the DSP system as a neutron detector is demonstrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Control of whistler radiation efficiency of a loop antenna by generation of ambient magnetic field irregularities

Electrodynamic means for the control of loop antenna radiation efficiency in plasma is proposed, which can be used in the whistler frequency band. The method is based on the generation, without perturbing the plasma density, of localized ambient magnetic field irregularities in the vicinity of the antenna. In order to produce such irregularities, it is suggested to feed the antenna with additional dc current along with the rf current. Experiments performed in a large laboratory magnetoplasma showed that the generation of localized magnetic field enhancements provides the possibility of increasing the amplitude of the whistlers emitted by the loop antenna. Moreover, experiments have shown that the amplification of the whistlers' signals from the receiving loop antenna fed with additional dc current is observed when a static magnetic field enhancement is generated in the vicinity of the receiver. The experimental data are in good agreement with the theoretical results obtained for comparatively weak ambient magnetic field perturbations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design, production and first commissioning results of the electrical feedboxes of the LHC

A total of 44 CERN designed cryogenic electrical feedboxes are needed to power the LHC superconducting magnets. The feedboxes include more than 1000 superconducting circuits fed by high temperature superconductor and conventional current leads ranging from 120 A to 13 kA. In addition to providing the electrical current to the superconducting circuits, they also ensure specific mechanical and cryogenic functions for the LHC. The paper focuses on the main design aspects and related production operations and gives an overview of specific technologies employed. Results of the commissioning of the feedboxes of the first LHC sectors are presented.

43 PARTICLE ACCELERATORS↗

Parametric coupling of a lower hybrid pump with neutral beam driven ion cyclotron instability in a tokamak

The parametric coupling of a high amplitude lower hybrid wave with the ion cyclotron instability, driven by neutral beam converted ion beam, is studied. The coupling is strong when the wave numbers of the pump and the ion cyclotron wave are perpendicular to each other; it produces lower hybrid sidebands. When the upper sideband is resonant, the growth rate of the instability is suppressed as the energy is fed into the upper sideband by the pump and the ion cyclotron wave. At different wave numbers when the lower sideband is resonant, the parametric coupling leads to the enhancement of growth rate. The effect is important when electron quiver velocity is greater than the sound speed. The study is relevant to advanced stage operations of a tokamak like ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

{beta}-delayed particle studies of the halo nucleus {sup 11}Li and its core {sup 9}Li

The {beta}-decay of {sup 11}Li and its core {sup 9}Li has been revisited with the aim to disentangle the very complex decays from unbound states in the daughters. The decay channels for the states fed by {beta}-decay in {sup 9}Be are established including the 2.43 MeV state for which the analysis of {alpha}{alpha} and n{alpha} spectra seem to favour direct break-up of the level. For the decay of {sup 11}Li the {beta}-delayed charged particle spectrum can be explained by the contribution of the 10.6 and 18.2 MeV states. The {alpha}{alpha} correlations indicates that decay through resonant He-isotopes are more likely than phase space distributed 5-body break-up.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Magnetic field structure evolution in rotating magnetic field plasmas

A study of magnetic field structure evolution during 40-ms plasma discharge has been performed in a new device with 80 cm long/40 cm diameter cylindrical chamber, in which a plasma current I{sub p}{approx_equal}2 kA was driven and sustained by a rotating magnetic field. The main focus of the experiments is on how the changes in externally applied magnetic field affect the current profile and magnetic field in plasma. During plasma discharge, a pulse current was briefly fed to a magnetic coil located at the midplane (middle coil). The magnetic field in cross section of plasma was scanned with pickup probes. Two regimes were studied: without and with an external toroidal field (TF) produced by axial I{sub z} current. With a relatively small current (I{sub m} {<=} 600 A) in the middle coil, the plasma current is boosted up to 5 kA. The magnetic flux surfaces become extended along the axial Z direction, sometimes with the formation of doublet shape plasma. The regime without TF appears to be less stable, presumably due to the reversal of plasma current in central area of plasma column.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and characterization of a thermal hydrogen atom source

The hydrogen atom source considered here incorporates a hot capillary fed by hydrogen gas. Our earlier measurements on a source heated by electron bombardment are interpreted in terms of a simple model which encourages us to design a source heated by the radiation from a filament. The radiatively heated source is much simpler, more reliable, and easier to run than the electronically heated source. Furthermore, the radiatively heated source is free of any energetic particles. In order to obtain quantitative data on the intensity, an apparatus is constructed revealing the angular distribution of the hydrogen atoms and molecules by means of a quadrupole mass analyzer. The intensity of the source is controlled by the mass flow rate of the feed gas and the electric power to the filament. The flux density of hydrogen atoms at a substrate 6 cm away from the source is variable over two orders of magnitude and extends up to some 10{sup 15} atoms/cm{sup 2} s.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Incorporation of {sup 210}Pb and {sup 210}Po to Poultry through the Addition of Dicalcium Phosphate (DCP) to the Diet

Due to the replacement of calcium by uranium in the phosphorite, sedimentary phosphate rock contains high concentrations of {sup 238}U (i.e. from 1500 Bq{center_dot}kg{sup -1} in Morocco to 4000 Bq{center_dot}kg{sup -1} in Tanzania ores). Dicalcium Phosphate (DCP) is produced by the wet acid digestion of the phosphorite, and is used as a source of calcium and phosphorus for livestock feed supplement. If the phosphorite acid digestion is made with hydrochloric acid, DCP may present specific activities of about 10{sup 3} Bq{center_dot}kg{sup -1} of {sup 238}U and some of its decay chain daughters. In particular, due to its radiological implications, the presence of {sup 210}Pb and {sup 210}Po in DCP is of special relevance. The aim of this work was to investigate the potential incorporation of these radionuclides to poultry through its diet. Three different diets were therefore prepared with different contents of both DCP and {sup 210}Pb and {sup 210}Po. Diet A was used as a blank, and had a 2.5% in weight of monocalcium phosphate (MCP); diet B, with a 5% in weight of DCP; and diet C, with a 2.5% of DCP. Concentrations of {sup 210}Pb were 0.93, 101.4 and 51.2 Bq{center_dot}kg{sup -1}; whereas concentrations of {sup 210}Po were 0.92, 74 and 36 Bq{center_dot}kg{sup -1} of food for diets A, B and C, respectively. Accumulation of {sup 210}Pb and {sup 210}Po was analysed at several times during poultry growth in samples of bone, liver, kidney, muscle, excrements as well as entire animals, with a total of 30 broilers fed with the 3 different diets. Results showed clear enhancements in the accumulation of both {sup 210}Pb and {sup 210}Po in chicken for diets B and C, and in particular in liver and bone. However, total accumulation of radionuclides in chicken, and especially in edible parts, is low compared to its expulsion through excrements. These results are interpreted in terms of the potential dose through consumption of chicken.

54 ENVIRONMENTAL SCIENCES↗

Assessing the validity of modulation transfer function evaluation techniques with application to small area and scanned digital detectors

A novel prototype step and shoot x-ray system, the intelligent imaging system (I-Imas), has been developed in the UCL Radiation Physics laboratories. The system uses collimators to split the beam into two: the first, 'scout' beam, strongly attenuated, identifies regions of interest in the image. This information is then fed back to the system so that the intensity of the second beam is modulated to optimize the dose distribution--i.e., ''interesting'' regions of the sample receive a higher dose, whereas other regions receive a lower one. Such systems may be capable of improved diagnostic capability at the same overall patient dose levels as typical when using large area digital plates. This acquisition mode means that large overall images are obtained by aligning many smaller images. This paper investigates the effects that this acquisition modality has on the overall spatial resolution of the system. We review different modulation transfer function (MTF) evaluation techniques and those shown to be optimal are used in the investigation of two considerations key to such a system: (i) whether there is a minimum size sensor whose MTF can accurately be determined using these techniques and (ii) whether the MTF of the large overall image differs significantly from those of the many constituent images. As the use of step and shoot systems is becoming more and more widespread, both are important considerations. We found that, for a fixed pixel pitch, the MTF is determined marginally less accurately the smaller the sensor area, with the perceived resolution varying by up to 0.1 lp/mm. It was also found that use of such a step and shoot technique does cause a very small overall degradation in resolution. The resolution of overall images was calculated to be 0.1 lp/mm lower than that of the individual images acquired.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo ICRH simulations in fully shaped anisotropic plasmas

In order to numerically study the effects of Ion Cyclotron Resonant Heating (ICRH) on the fast particle distribution function in general plasma geometries, three codes have been coupled: VMEC generates a general (2D or 3D) MHD equilibrium including full shaping and pressure anisotropy. This equilibrium is then mapped into Boozer coordinates. The full-wave code LEMan then calculates the power deposition and electromagnetic field strength of a wave field generated by a chosen antenna using a warm model. Finally, the single particle Hamiltonian code VENUS combines the outputs of the two previous codes in order to calculate the evolution of the distribution function. Within VENUS, Monte Carlo operators for Coulomb collisions of the fast particles with the background plasma have been implemented, accounting for pitch angle and energy scattering. Also, ICRH is simulated using Monte Carlo operators on the Doppler shifted resonant layer. The latter operators act in velocity space and induce a change of perpendicular and parallel velocity depending on the electric field strength and the corresponding wave vector. Eventually, the change in the distribution function will then be fed into VMEC for generating a new equilibrium and thus a self-consistent solution can be found. This model is an enhancement of previous studies in that it is able to include full 3D effects such as magnetic ripple, treat the effects of non-zero orbit width consistently and include the generation and effects of pressure anisotropy. Here, first results of coupling the three codes will be shown in 2D tokamak geometries.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Decays of New Nuclides and Isomers Beyond the Proton Drip Line--The Influence of Neutron Configurations

The energy of the vh{sub 9/2} orbital in nuclei above N = 82 drops rapidly in energy relative to the vf{sub 7/2} orbital as the occupancy of the {pi}h{sub 11/2} orbital increases. These two neutron orbitals become nearly degenerate as the proton drip line is approached. In this work, we have discovered the new nuclides {sup 161}Os and {sup 157}W, and studied the decays of the proton emitter {sup 160}Re in detail. The {sup 161}Os and {sup 160}Re nuclei were produced in reactions of 290, 300 and 310 MeV {sup 58}Ni ions with an isotopically enriched {sup 106}Cd target, separated in-flight using the RITU separator and implanted into the GREAT spectrometer. The {sup 161}Os{alpha} a decays populated the new nuclide {sup 157}W, which decayed by {beta}-particle emission. The {beta} decay fed the known {alpha}-decaying 1/2{sup +} and 11/2{sup -} states in {sup 157}Ta, which is consistent with a vf{sub 7/2} ground state in {sup 157}W. The measured {alpha}-decay energy and half-life for {sup 161}Os correspond to a reduced {alpha}-decay width that is compatible with s-wave {alpha}-particle emission, implying that its ground state is also a vf{sub 7/2} state. Over 7000 {sup 160}Re nuclei were produced and the {gamma} decays of a new isomeric state feeding the {pi}d{sub 3/2} level in {sup 160}Re were discovered, but no evidence for the proton or a decay of the expected {pi}h{sub 11/2} state could be found. The isomer decays offer a natural explanation for this non-observation and provides a striking example of the influence of the near degeneracy of the vh{sub 9/2} and vf{sub 7/2} orbitals on the properties of nuclei in this region.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of Electrothermal Pulsed Plasma Thrusters for Osaka-Institute-of-Technology Electric-Rocket-Engine onboard Small Space Ship

The Project of Osaka-Institute-of-Technology Electric-Rocket-Engine onboard Small Space Ship (PROITERES) was started at Osaka Institute of Technology. In PROITERES, a 10-kg small satellite with electrothermal pulsed plasma thrusters (PPTs), named JOSHO, will be launched in 2010. The main mission is powered flight of small satellite by electric thruster itself. Electrothermal PPTs were studied with both experiments and numerical simulations. An electrothermal PPT with a side-fed propellant feeding mechanism achieved a total impulse of 3.6 Ns with a repetitive 10000-shot operation. An unsteady numerical simulation showed the existence of considerable amount of ablation delaying to the discharge. However, it was also shown that this phenomenon should not be regarded as the 'late time ablation' for electrothermal PPTs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗