Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy Data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Upgrade of the Minos+ Experiment Data Acquisition for the High Energy NuMI Beam Run

The Minos+ experiment is an extension of the Minos experiment at a higher energy and more intense neutrino beam, with the data collection having begun in the fall of 2013. The neutrino beam is provided by the Neutrinos from the Main Injector (NuMI) beam-line at Fermi National Accelerator Laboratory (Fermilab). The detector apparatus consists of two main detectors, one underground at Fermilab and the other in Soudan, Minnesota with the purpose of studying neutrino oscillations at a base line of 735 km. The original data acquisition system has been running for several years collecting data from NuMI, but with the extended run from 2013, parts of the system needed to be replaced due to obsolescence, reliability problems, and data throughput limitations. Specifically, we have replaced the front-end readout controllers, event builder, and data acquisition computing and trigger processing farms with modern, modular and reliable devices with few single points of failure. The new system is based on gigabit Ethernet TCP/IP communication to implement the event building and concatenation of data from many front-end VME readout crates. The simplicity and partitionability of the new system greatly eases the debugging and diagnosing process. As a result, the new system improves throughput by about a factor of three compared to the old system, up to 800 megabits per second, and has proven robust and reliable in the current run.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Near optimal energy selective x-ray imaging system performance with simple detectors

Purpose: This article describes a method to achieve near optimal performance with low energy resolution detectors. Tapiovaara and Wagner [Phys. Med. Biol. 30, 519-529 (1985)] showed that an energy selective x-ray system using a broad spectrum source can produce images with a larger signal to noise ratio (SNR) than conventional systems using energy integrating or photon counting detectors. They showed that there is an upper limit to the SNR and that it can be achieved by measuring full spectrum information and then using an optimal energy dependent weighting. Methods: A performance measure is derived by applying statistical detection theory to an abstract vector space of the line integrals of the basis set coefficients of the two function approximation to the x-ray attenuation coefficient. The approach produces optimal results that utilize all the available energy dependent data. The method can be used with any energy selective detector and is applied not only to detectors using pulse height analysis (PHA) but also to a detector that simultaneously measures the total photon number and integrated energy, as discussed by Roessl et al. [Med. Phys. 34, 959-966 (2007)]. A generalization of this detector that improves the performance is introduced. A method is described to compute images with the optimal SNR using projections in a ''whitened'' vector space transformed so the noise is uncorrelated and has unit variance in both coordinates. Material canceled images with optimal SNR can also be computed by projections in this space. Results: The performance measure is validated by showing that it provides the Tapiovaara-Wagner optimal results for a detector with full energy information and also a conventional detector. The performance with different types of detectors is compared to the ideal SNR as a function of x-ray tube voltage and subject thickness. A detector that combines two bin PHA with a simultaneous measurement of integrated photon energy provides near ideal performance across a wide range of operating conditions. Conclusions: Low energy resolution detectors can be used in energy selective x-ray imaging systems to produce images with near optimal performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of the charge dependence of the pion–nucleon coupling constant on the basis of data on low-energy nucleon–nucleon interactions

The relation between quantities that characterize the pion–nucleon and nucleon–nucleon interactions is studied with allowance for the fact that, at low energies, nuclear forces in nucleon–nucleon systems are mediated predominantly by one-pion exchange. On the basis of the values currently recommended for the low-energy parameters of the proton–proton interaction, the charged pion–nucleon coupling constant is evaluated at g{sub π}{sup 2}±/4π = 14.55(13). This value is in perfect agreement with the experimental value of g{sub π}{sup 2}±/4π = 14.52(26) found by the Uppsala Neutron Research Group. At the same time, the value obtained for the charged pion–nucleon coupling constant differs sizably from the value of the pion–nucleon coupling constant for neutral pions, which is g{sub π}{sup 2} 0/4π = 13.55(13). This is indicative of a substantial charge dependence of the coupling constant.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Continuous Energy Neutron Cross Section Data Tables Based upon ENDF/B-VII.1

In December 2011, the National Nuclear Data Center (NNDC) released ENDF/BVII.1, the “latest recommended evaluated nuclear data file for use in nuclear science and technology applications”. The data was released in the standard Evaluated Nuclear Data Format (ENDF). This release represents the advances made in nuclear data during the five years since the release of ENDF/B-VII.0. The Nuclear Data Team at Los Alamos National Laboratory has processed the ENDF/B-VII.1 library and has made available a library of ACE data tables at several temperatures for each of the ENDF/B files. The ACE data library is called ENDF71x.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Using Field-Metered Data to Quantify Annual Energy Use of Residential Portable Unit Dehumidifiers

The U.S. Energy Information Administration (EIA) reports that space heating and cooling no longer account for the majority of all residential energy consumption (they represented 47.7 percent in 2009). According to EIA, energy consumption for appliances, lighting, and electronics not only represents the majority of residential consumption, but continues to rise. Some of the decline in energy use for space heating and cooling may be attributable to better-insulated structures and population shifts to warmer climates. Those same factors may be contributing to an increased reliance on space-conditioning appliances, specifically dehumidifiers. Additionally, as the world’s climate changes, it is expected that absolute humidity will rise along with temperature. A recent study reports that continued climate warming will place significant limitations on human activity in typically hotter, more humid environments. Increased human discomfort may drive an even greater use of dehumidifiers and a resulting increase in residential energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Telematics and Data Science: Informing Energy-Efficient Mobility: October 25, 2016 - October 31, 2017

The University of Connecticut (UCONN) is exploring the possibility of adding electric vehicles (EVs) - including battery electric vehicles (BEVs), plug-in hybrid electric vehicles (PHEVs), or both-to its vehicle fleet. This report presents results of the UCONN fleet EV Suitability pilot program and offers recommendations for transitioning fleet vehicles to EVs as well as implementing adequate charging infrastructure.

33 ADVANCED PROPULSION SYSTEMS↗

Energetic electrons in Jupiter's dawn magnetodisc

The paper presents and analyzes absolute energy density data on electrons from the University of Iowa instrument on Pioneer 10 for one example of a plasma sheet traversal in Jupiter's dawn magnetodisk on 6-7 December 1973. The absolute integral omnidirectional intensity spectrum of electrons is based on a full and accurate reduction of the counting rate data. The main finding is that electrons of energy greater than 0.060 MeV provide only about 3% of the charged particle pressure required to explain the observed depression in the magnetic field at the center of the plasma sheet, in spite of the fact that the intensity of such electrons is well correlated with the depression of the magnetic pressure throughout the sheet.

Van Allen, J. A.↗