Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EVA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Creating the Test Environment for Exploration Habitats

The Crew and Thermal Systems Division’s (CTSD) 20 Foot Chamber has undergone significant modifications to support NASA’s future human exploration missions to the Moon, Mars, and beyond. Existing chamber systems such as Vacuum/Repress, Heating Ventilation and Air Conditioning (HVAC), and Fire Suppression System (FSS), were upgraded, while new systems such as Air Revitalization and Gas Distribution were added. In addition, the chamber was outfitted with crew quarters, hygiene areas, storage, and workspaces. Teams across the Johnson Space Center (JSC) worked together to overcome the logistical and operational challenges of the planned test parameters. The ultimate goal was to create an analog testbed in which a maximum of eight human test subjects could safely live and work for at least 11 days in the same conditions (e.g., reduced pressures, oxygen concentrations, and so on) as those expected inside a base spacecraft. This would allow researchers to study the effects of such environments on humans and to validate proposed Prebreathe Protocols to enable the safe performance of surface extravehicular activities (EVAs). Over the last 18 months, the CTSD Systems Test Branch has performed six tests of varying lengths and atmospheres for both NASA and commercial partners. To date, researchers now have collected data on 48 test subjects in the course of 42 days and over 130 simulated EVAs. This paper will discuss the history of the 20 Foot Chamber, its long road to becoming an analog testbed for human exploration, and the capabilities that make it a unique, world class facility for NASA and commercial human exploration missions. It will provide an overview of past and future testing and the lessons learned along the way.

Cristina A Anchondo↗

Safe Exploration: Sensorimotor Assessments for Early Extravehicular Activities

BACKGROUND: Artemis missions will require a new level of crew autonomy around periods of gravitational transition, where sensorimotor disturbances are at their highest. There is a need to define performance thresholds for key sensorimotor assessments that indicate when performance in early extravehicular activities (EVAs) might be impacted or unsafe. This panel presentation will discuss the development of sensorimotor assessments for determining crew preparedness of early EVAs by utilizing a novel portable sensorimotor disorientation analog and other spaceflight analogs. OVERVIEW: To define performance thresholds, a proposed set of sensorimotor assessment tasks must be validated under various spaceflight analogs. A Sensorimotor Disorientation Analog (SDA) was developed that could induce varying levels of disorientation through combined vestibular (galvanic vestibular stimulation (GVS)) and proprioceptive (weighted chest, ankles, and wrists) disruptions. The SDA was first pilot tested using subjective feedback from previously flown astronauts to determine the levels of disorientation that mimic motor performance immediately (R+0) and +24 hours (R+1) postflight. A second study was performed using healthy non-astronaut ground subjects to validate the SDA levels by comparing to astronaut postflight data. The validated SDA was utilized in a third study to map performance in the proposed set of sensorimotor assessment tasks to operational tasks. The assessment tasks were defined based on lessons learned from Apollo and subject matter experts (e.g., flight surgeons) to include the following: 1) aid in progressive adaptation to the novel gravitational environment; 2) provide opportunities to develop strategies to recover from off-nominal body positions; and 3) mimic operational tasks such that crew can self-assess their potential ability to complete their missions. This presentation will conclude with a discussion on future validation studies of the proposed assessment tasks using other spaceflight analogs such as centrifugation and gravity offload systems. DISCUSSION: Exploration class missions will require crew to be able to self-assess and treat their sensorimotor dysfunction after gravity transitions, and in off-nominal situations they may be required to perform provocative, challenging tasks soon after landing. This panel presentation will discuss current and ongoing research strategies to address the sensorimotor risk on safe exploration during Artemis missions.

Sarah Moudy↗

NASA Advanced Space Suit Pressure Garment System Status and Development Priorities 2024

This paper discusses the current focus of NASA’s Advanced Space Suit Pressure Garment Technology Development team’s efforts, the status of that work, and a summary of longer term technology development priorities and activities. The Exploration Extra-vehicular Activity Mobility Unit (xEMU) has been the team’s primary effort over the past several years. This paper documents the various tests executed with the xPGS to evaluate its performance, durability, and acceptability for microgravity and Lunar missions. An overview of ongoing and planned xEMU testing and training is provided. The PGS team’s efforts in supporting the Exploration Extravehicular Activity Services (xEVAS) vendors is discussed. In addition, technology development efforts in coordination with the EVA and Human Surface Mobility Program (EHP), the NASA Engineering Safety Council (NESC) and the Small Business Innovation Research (SBIR) Program will be discussed in the context of supporting sustaining EVA operations on the Lunar surface over the coming decade. Finally, a brief review of longer-term pressure garment challenges and technology gaps will be presented to provide an understanding of the advanced pressure garment team’s technology investment priorities and needs.

Shane M McFarland↗

LTV-xEVA Applied Injury Biomechanics

Beginning in Artemis V, Lunar Terrain Vehicles (LTV) will be utilized to enable astronauts to explore the lunar south pole and conduct science farther from the landing site than during the Apollo program. However, LTV operation has the potential to cause injury to the suited crew member during their Extravehicular Activity (EVA). Injury risk caused by LTV acceleration and jerk combined with blunt loading from rigid suit components needs to be better understood. An effort began to create requirements for, model, and address the injury risk caused by the LTV combined with Exploration EVA (xEVA) suits. Mitigation of crew injury is a shared responsibility between LTV and the suit since neither can accomplish this independently. The modeling completed in Fiscal Year 2023 (FY23) helped to verify the fidelity of the requirements and parse out vendor responsibility (LTV, xEVAS, or NASA) for Artemis V and beyond. The scope of the modeling in FY23 used the LTV System Requirements Document (SRD) as worst-case inputs and modeled female 5th-, male 50th-, and male 95th-percentile subjects in hard-mounted seated and semi-standing postures. Soft-mounted (i.e., lap belt) and testing to validate the analysis was determined out of scope for FY23 work.

Spacesuit↗

Validation Testing and Statistical Analysis of the Rotary Tumbler Fabric Abrasion Method

The Artemis space suit glove environmental protection garment (EPG) will be the first line of protection used to shield the crewmember’s hands from the environments encountered during extravehicular activity (EVA). As the Artemis missions will include more extreme environments than those experienced on the International Space Station, development, verification, and validation of gloves requires the development of new test methods. A previous paper focused on the development of a test procedure to characterize lunar EVA glove fabrics using ASTM standardized test methods and the design and validation of a new standardized test procedure for comparing abrasion resistance between fabrics using a dust and rock filled rotary tumbler. Preliminary results of testing were presented in that paper. This paper reports on the validation testing and statistical analysis of the newly developed tumbler abrasion test method.

Robert J Jones↗

Wire-break Ignition Testing of Materials for Spacesuit Fire Hazard Control

The input design constraints applied to the extravehicular activity (EVA) spacesuit pose a significant challenge for mitigation of fire hazards. To minimize fatigue and increase comfort of the crewmember operating the suit, the suit pressure is lowered below sea level conditions with typical EVA suit designs operating with 4.3 psia (29.7 kPa). With the lowered operating pressures and the use of closed-loop life support, the suit requires elevated concentrations of oxygen, typically >95%. At these oxygen concentrations, nearly the entirety of the suit internal materials are flammable. This leaves one remaining possible control leg of the fire triangle: ignition sources. Since the Gemini and Apollo programs, this has been a risk that has undergone constant reassessment, with a focus on improved mitigation. After the Apollo I fire, an arc ignition method was developed and used to quantify ignition thresholds for in-suit materials resulting in a current limit for powered in-suit devices applied to all subsequent suit designs. After the discovery of a frayed spacesuit biomed cable on STS-113 during the Shuttle Program, the previous arcing method was repeated with additional methods developed to extend the testing further. One of those methods was wire-break ignition testing, in which the current in a single strand of wire was progressively increased, preheating the material in proximity with a resultant break and the application of a reasonably repeatable arc to ignite the material, all while exposed in the selected environment. This method was used to test a suite of spacesuit materials providing relative performance with respect to ignition with this configuration for application of energy. This paper discusses extension of the current data set to address recent material additions, lowering of energy test levels for quantification of materials too low to measure in previous testing, as well as future plans to improve this method.

Colin Campbell↗

LTV-xEVA Applied Injury Biomechanics

Beginning in Artemis V, Lunar Terrain Vehicles (LTV) will be utilized to enable astronauts to explore the lunar south pole and conduct science farther from the landing site than during the Apollo program. However, LTV operation has the potential to cause injury to the suited crew member during their Extravehicular Activity (EVA). Injury risk caused by LTV acceleration and jerk combined with blunt loading from rigid suit components needs to be better understood. An effort began to create requirements for, model, and address the injury risk caused by the LTV combined with Exploration EVA (xEVA) suits. Mitigation of crew injury is a shared responsibility between LTV and the suit since neither can accomplish this independently. The modeling completed in Fiscal Year 2023 (FY23) helped to verify the fidelity of the requirements and parse out vendor responsibility (LTV, xEVAS, or NASA) for Artemis V and beyond. The scope of the modeling in FY23 used the LTV System Requirements Document (SRD) as worst-case inputs and modeled female 5th-, male 50th-, and male 95th-percentile subjects in hard-mounted seated and semi-standing postures. Soft-mounted (i.e., lap belt) and testing to validate the analysis was determined out of scope for FY23 work.

Spacesuit↗

NASA Advanced Space Suit Pressure Garment System Status and Development Priorities 2024

This paper discusses the current focus of NASA’s Advanced Space Suit Pressure Garment Technology Development team’s efforts, the status of that work, and a summary of longer term technology development priorities and activities. The Exploration Extra-vehicular Activity Mobility Unit (xEMU) has been the team’s primary effort over the past several years. This paper documents the various tests executed with the xPGS to evaluate its performance, durability, and acceptability for microgravity and Lunar missions. An overview of ongoing and planned xEMU testing and training is provided. The PGS team’s efforts in supporting the Exploration Extravehicular Activity Services (xEVAS) vendors is discussed. In addition, technology development efforts in coordination with the EVA and Human Surface Mobility Program (EHP), the NASA Engineering Safety Council (NESC) and the Small Business Innovation Research (SBIR) Program will be discussed in the context of supporting sustaining EVA operations on the Lunar surface over the coming decade. Finally, a brief review of longer-term pressure garment challenges and technology gaps will be presented to provide an understanding of the advanced pressure garment team’s technology investment priorities and needs.

Shane McFarland↗

Creating the Test Environment for Exploration Habitats

The Crew and Thermal Systems Division’s (CTSD) 20 Foot Chamber has undergone significant modifications to support NASA’s future human exploration missions to the Moon, Mars, and beyond. Existing chamber systems such as Vacuum/Repress, Heating Ventilation and Air Conditioning (HVAC), and Fire Suppression System (FSS), were upgraded, while new systems such as Air Revitalization and Gas Distribution were added. In addition, the chamber was outfitted with crew quarters, hygiene areas, storage, and workspaces. Teams across the Johnson Space Center (JSC) worked together to overcome the logistical and operational challenges of the planned test parameters. The ultimate goal was to create an analog testbed in which a maximum of eight human test subjects could safely live and work for at least 11 days in the same conditions (e.g., reduced pressures, oxygen concentrations, and so on) as those expected inside a base spacecraft. This would allow researchers to study the effects of such environments on humans and to validate proposed Prebreathe Protocols to enable the safe performance of surface extravehicular activities (EVAs). Over the last 18 months, the CTSD Systems Test Branch has performed six tests of varying lengths and atmospheres for both NASA and commercial partners. To date, researchers now have collected data on 48 test subjects in the course of 42 days and over 130 simulated EVAs. This paper will discuss the history of the 20 Foot Chamber, its long road to becoming an analog testbed for human exploration, and the capabilities that make it a unique, world class facility for NASA and commercial human exploration missions. It will provide an overview of past and future testing and the lessons learned along the way.

Chris Briggs↗

Evaluation of Long-Term Storage Stability and Operational Efficiency of Rapid Cycle Amine Adsorbents

With the recent incorporation of Mars Extravehicular Activity (EVA) into the 2025 NASA roadmap, Rapid Cycle Amine (RCA) technology advancement within the Exploration Extravehicular Mobility Unit (xEMU) applies to both the upcoming Lunar Artemis missions and future human exploration of Mars. The incorporation of commercial spacesuit vendors to service NASA’s crewed-space programs since 2021 has increased the demand for regenerable, RCA-based carbon dioxide (CO2) and humidity control adsorbents. The regenerable RCA subunit is the most advanced, long-term solution for CO2 removal and humidity control, enabling both lunar and Martian EVAs. The adsorbent selected for use within the RCA unit must exhibit sufficient storage stability and operational efficiency for prolonged missions. As XploSafe worked to simultaneously develop both a recirculating sub-atmospheric test rig and adsorbents for the RCA system within the xEMU, several novel adsorbents were evaluated for long-term storage stability in support of future extended-duration missions. The chosen materials were periodically evaluated by nuclear magnetic resonance (NMR) spectroscopy, thermal desorption-coupled with gas chromatography/mass spectrometry (TD-GC/MS), and CO2 adsorption to assess long-term storage efficacy across various environmental storage conditions. NMR spectroscopy was utilized by extracting the active CO2 adsorbing chemical from the solid support with deuterated solvent and comparing the spectra over time for degradation and change. The solid adsorbents were also analyzed via TD-GC/MS to reveal any potential off-gassing chemicals over time. Additionally, XploSafe’s breakthrough test rig was utilized to dose the solid adsorbents with a 585 BTU/h metabolic rate flow-equivalent CO2 stream and monitored for 0–99% CO2 breakthrough. The performance metrics from the breakthrough analysis were compared over the storage study duration for CO2 removal and humidity control. Xplo-SA9T was evaluated for 24 months, whereas two additional adsorbent variants, MMPA-Sorbent and LPEI-Sorbent, were each evaluated for 12 months.

John R Tidwell↗

Recirculating and Sub-Atmospheric Rapid Cycle Amine Swing Bed Testing at Various Metabolic Profiles, Temperatures, and Half-Cycle Times

Sixty years since the first spacewalk, NASA’s Extravehicular Mobility Unit (xEMU) exploration space suit has undergone numerous design improvements and iterations. As commercial manufacturers develop next-generation systems to support increasingly complex missions, including Moon-to-Mars architecture prototyping and the design of the Martian Portable Life Support System (PLSS), material selection and individual subunit testing under realistic metabolic and pressure conditions are paramount. To determine whether a reusable carbon dioxide (CO 2 ) scrubber design and adsorbent can be utilized in new suit configurations, an all-encompassing test rig is required to compare existing and newly developed technologies. The test rig must be capable of sub-atmospheric testing, calibrated humid CO 2 dosing, and facilitation of the evaluation of sorbents across a wide range of operational requirements. Recently, XploSafe has developed an Extravehicular Mobility Unit (xEMU) testing rig specifically designed to explore CO 2 and humidity control materials for spacesuits. This closed-loop recirculating swing bed (Rapid Cycle Amine Test Rig) was utilized to compare adsorbent utility across a wide range of xEMU operating conditions. Following successful testing with Xplo-SA9T over multiple simulated eight-hour Extravehicular Activity (EVA) tests, improvements to the test stand were considered. Regeneration vacuum supply within the test rig was updated to more closely resemble space vacuum, theoretically increasing half-cycle timing. An improved water vapor delivery system was incorporated to dose a wider calibrated range of humidity over both short and long-duration EVAs. A range of metabolic profiles between 800 and 3000 BTU/h were tested, and the corresponding average CO 2 steady-states were compared. The effect of dosing temperature at the adsorbent bed inlet between 10 and 40 ̊C and the corresponding CO 2 removal efficiency was also evaluated.

John R Tidwell↗

Artemis Suit Material Effects of Calendaring Woven Fabrics on Dust Resistance

This paper presents one element of an ongoing NASA technology-infusion effort to design, fabricate, and test a new outer shell fabric for a lunar Extravehicular Activity (EVA) space suit, a critical component of sustained lunar exploration. A primary challenge for suit textiles is preventing lunar dust, which is highly abrasive, electrostatically charged, and capable of infiltrating even tightly woven fabrics from penetrating the Environment Protection Garment (EPG) and compromising suit durability and astronaut safety. To enhance dust-blocking performance, the Artemis Suit Materials Team investigated calendaring, a continuous roll to roll mechanical finishing process in which fabric passes through heated rollers under high pressure to compress and flatten the weave, thereby reducing pore size and modifying surface texture without significantly affecting other properties. Targeted testing of calendared Teflon™ T-162 and Ortho Fabric samples provides new insight into how calendaring influences dust resistance, informing future material development and advancing EVA suit technology for long-duration lunar missions.

Dust↗

Artemis Suit Material Optical Property Testing of Dust Exposed Fabrics

This paper highlights one aspect of NASA’s ongoing technology-infusion effort to design, fabricate, and test a next-generation outer shell fabric for a lunar Extravehicular Activity (EVA) space suit, a critical component of sustained lunar exploration. Managing thermal loads on the Moon is essential for astronaut safety and suit performance. The suit’s exterior fabric directly influences heat gain and loss through its optical properties: low solar absorptivity minimizes sunlight absorption, while high infrared emissivity aids radiative cooling. Lunar regolith complicates this balance. Its fine, abrasive particles possess unique optical behavior that can lower reflectivity and raise emissivity when embedded in or adhered to fabric surfaces, degrading thermal control and increasing the risk of overheating or cooling inefficiency. To quantify these effects, the Artemis Suit Materials (ASM) team measured solar absorptance and infrared emissivity of clean and dust-soiled Ortho Fabric, establishing beginning-of-life (BOL) and end-of-life (EOL) benchmarks. EOL conditions were simulated with a rotary tumbler abrasion process using lunar dust simulant and ceramic media to reproduce cumulative wear expected during surface operations. Tests also included unmodified fabrics and a fabric/film laminate system containing titanium dioxide to evaluate potential improvements in dust resistance and optical performance. Results from these evaluations provide critical insight into how lunar dust alters fabric thermal behavior and inform the design of bespoke suit materials that maintain required optical properties throughout mission life, supporting safe and effective long-duration EVA on the lunar surface.

space↗

Does the International Space Station Leak DNA? Preliminary Results from the ISS External Microorganisms Payload

Existing crewed spacecraft like the ISS (International Space Station) leak by design. The ISS routinely releases gas to maintain life support systems and when astronauts exit the station to perform space walks. The chemical component of this leakage is well characterized, but the biological components are not. The ISS is not subject to planetary protection requirements, but planned missions to Mars will use similar systems and will be subject to planetary protection requirements. If detectable microorganisms are escaping through vents and or airlocks we may need to redesign our crewed habitats to minimize this type of contamination. To test the hypothesis that microorganisms from inside ISS are detectable on exterior surfaces an astronaut used the ISS External Microorganisms sampling kit (Rucker et al. 2018) to sample exterior surfaces of the ISS during an EVA (Extra Vehicular Activity) in January of 2025. These samples were returned to Earth for DNA extraction and sequencing. We successfully, extracted and sequenced bacterial, fungal and viral DNA from these samples that was not present in the negative controls. These results should help NASA refine the planetary protection requirements for crewed missions. Methods: The samples were collected using sterile, DNA free, buccal swabs (23 mm. diameter) housed in custom canisters. Each canister uses a 0.2 μm Teflon filter to maintain sterility as the caddy, holding 8 swabs moves in and out of vacuum. The astronaut sampled the: 1) airlock vestibule, 2) airlock thermal cover, 3) a gap in the micrometeorite shielding near the airlock, 4) a handrail near the airlock, 5) the Carbon Dioxide Removal Assembly vent, and 6) the Vacuum Exhaust System vent. The seventh swab was exposed to vacuum during the EVA without touching it to a surface. The eighth swab, a negative control, was not opened until the caddy returned to Earth. DNA was extracted from the swabs using a QIamp UCP Pathogen kit and prepared for sequencing on an Aviti (Element Biosciences) sequencer (Arslan et al. 2024). The resulting sequences were analyzed using the EDGE Bioinformatics platform (Li et al. 2017). The sequences were analyzed individually using tools like BLAST, GOTTCHA2, Kraken2, and PanGIA. The data were also assembled into metagenome assembled genomes) using tools like CONCOCT, MaxBin2 and MetaBAT2. Results: We successfully extracted and sequenced bacterial, archaeal, fungal and viral DNA from all seven samples. The handrail swab had the lowest number of reads (768,651) and the airlock thermal cover had the highest number of reads (8,819,230). These samples contain DNA from human associated bacteria (e.g. Crynebacterium riegelii ), fungi (.e.g. Penicillium rubens ), and viruses (e.g Alphapapillomavirus ). Conclusion: Preliminary interpretation suggest that the airlock and the space suits themselves are the largest sources of contaminant DNA. Most if not all of the DNA is from organisms known to be present inside the ISS. Vents attached to life support systems may be a lesser source of biological contamination. Further analysis should help NASA address planetary protection knowledge gaps for crewed missions.

Aaron B Regberg↗

Artemis Suit Material Effects of Calendaring Woven Fabrics on Dust Resistance

This paper presents one element of an ongoing NASA technology-infusion effort to design, fabricate, and test a new outer shell fabric for a lunar Extravehicular Activity (EVA) space suit, a critical component of sustained lunar exploration. A primary challenge for suit textiles is preventing lunar dust, which is highly abrasive, electrostatically charged, and capable of infiltrating even tightly woven fabrics from penetrating the Environment Protection Garment (EPG) and compromising suit durability and astronaut safety. To enhance dust-blocking performance, the Artemis Suit Materials Team investigated calendaring, a continuous roll to roll mechanical finishing process in which fabric passes through heated rollers under high pressure to compress and flatten the weave, thereby reducing pore size and modifying surface texture without significantly affecting other properties. Targeted testing of calendared Teflon™ T-162 and Ortho Fabric samples provides new insight into how calendaring influences dust resistance, informing future material development and advancing EVA suit technology for long-duration lunar missions.

Dust↗

Artemis Suit Material Optical Property Testing of Dust Exposed Fabrics

This paper highlights one aspect of NASA’s ongoing technology-infusion effort to design, fabricate, and test a next-generation outer shell fabric for a lunar Extravehicular Activity (EVA) space suit, a critical component of sustained lunar exploration. Managing thermal loads on the Moon is essential for astronaut safety and suit performance. The suit’s exterior fabric directly influences heat gain and loss through its optical properties: low solar absorptivity minimizes sunlight absorption, while high infrared emissivity aids radiative cooling. Lunar regolith complicates this balance. Its fine, abrasive particles possess unique optical behavior that can lower reflectivity and raise emissivity when embedded in or adhered to fabric surfaces, degrading thermal control and increasing the risk of overheating or cooling inefficiency. To quantify these effects, the Artemis Suit Materials (ASM) team measured solar absorptance and infrared emissivity of clean and dust-soiled Ortho Fabric, establishing beginning-of-life (BOL) and end-of-life (EOL) benchmarks. EOL conditions were simulated with a rotary tumbler abrasion process using lunar dust simulant and ceramic media to reproduce cumulative wear expected during surface operations. Tests also included unmodified fabrics and a fabric/film laminate system containing titanium dioxide to evaluate potential improvements in dust resistance and optical performance. Results from these evaluations provide critical insight into how lunar dust alters fabric thermal behavior and inform the design of bespoke suit materials that maintain required optical properties throughout mission life, supporting safe and effective long-duration EVA on the lunar surface.

Textile↗

Extrapolating Accelerated UV Weathering Data: Perspective From PVQAT Task Group 5 (Presentation)

Taskgroup 5 (TG5) is concerned with a accelerated aging standard incorporating factors including ultraviolet radiation, temperature, and moisture. Separate experiments are being conducted in support of a test standard via the regional sub-groups in Asia, Europe, and the United States. The authors will describe the objectives and timeline for the TG5 interlaboratory study being directed out of the USA. Qualitative preliminary data from the experiment is presented. To date, the encapsulation transmittance experiment has: replicated behaviors of fielded materials (including specimen location- and formulation additive-specific discoloration); demonstrated coupling between UV aging and temperature; demonstrated that degradation in EVA results from UV- aging; and obtained good qualitative comparison between Xe and UVA-340 sources for EVA. To date, the encapsulation adhesion experiment (using the compressive shear test to quantify strength of attachment) has demonstrated that attachment strength can decrease drastically (>50%) with age; however, early results suggest significant factor (UV, T, RH) dependence. Much remains to be learned about adhesion.

14 SOLAR ENERGY↗

Life after 30 years - a PV system in Colorado

The PV system consisted of 155 monocrystalline Si Arco M53 panels, installed in 1987. 80 were installed on a fixed tilt rack, and 75 on 5 separate dual-axis passive trackers. The system was decommissioned in 2017 due a campus re-design and building expansion at the Platte River Power Authority (PPRA) site. Prior to decommissioning a site visit established the following failure type observations: EVA browning (100%), cracked cells (60%), and cracked wires or grommets (9%, or more if replacements were made selectively on cracked parts). EVA browning is typical in modules of this vintage, whereas the occurrence of so many cracked cells is surprising and is likely weather-related. The fairly frequent occurrence of cracked wires and grommets serves as a reminder that accelerated testing of these components is important for goals of low-cost 50-year energy generation. In smaller numbers, thermal effects (7%), bent frames (1%), and cell corrosion (<1%) were observed. A sample of 20 modules was selected and brought to NREL for in-depth characterization. Because baseline measurements were not available using the nameplate rating, which can be inaccurate, revealed a mean module sample degradation of 0.7 %/year. Sporadic production data during the 30 years determined a system degradation rate closer to 1.2 %/year. Subsequently, four of these modules were re-mounted outdoors at NREL and are now approaching a total lifetime of 34 years.

durability↗