Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

High-Angular-Resolution Microbeam X-Ray Diffraction with CCD Detector

We have introduced a CCD-type two-dimensional X-ray detector for a microbeam X-ray diffraction system using synchrotron radiation, so that we can measure local reciprocal space maps (RSM) of samples rapidly. A local RSM of a strain-relaxed SiGe 004 grown on a Si (001) substrate was measured in higher-angular-resolution and faster than a conventional way. The measurement was achieved in 1 h 40 min. with the 2theta resolution of 80 murad and the spatial resolution of 1.4(h)x0.5(v) {mu}m{sup 2}. The introduction of the CCD enabled us to measure RSMs at many points in a sample, that is, the distribution of strain fields and lattice tilts can be revealed in high-angular- and high-spatial-resolution.

36 MATERIALS SCIENCE↗

Progress in Cell Marking for Synchrotron X-ray Computed Tomography

Recently there has been an increase in research activity into finding ways of marking cells in live animals for pre-clinical trials. Development of certain drugs and other therapies crucially depend on tracking particular cells or cell types in living systems. Therefore cell marking techniques are required which will enable longitudinal studies, where individuals can be examined several times over the course of a therapy or study. The benefits of being able to study both disease and therapy progression in individuals, rather than cohorts are clear. The need for high contrast 3-D imaging, without harming or altering the biological system requires a non-invasive yet penetrating imaging technique. The technique will also have to provide an appropriate spatial and contrast resolution. X-ray computed tomography offers rapid acquisition of 3-D images and is set to become one of the principal imaging techniques in this area. Work by our group over the last few years has shown that marking cells with gold nano-particles (GNP) is an effective means of visualising marked cells in-vivo using x-ray CT. Here we report the latest results from these studies. Synchrotron X-ray CT images of brain lesions in rats taken using the SYRMEP facility at the Elettra synchrotron in 2009 have been compared with histological examination of the tissues. Some deductions are drawn about the visibility of the gold loaded cells in both light microscopy and x-ray imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Pierre Auger Project and Enhancements

The current status of the scientific results of the Auger Observatory will be discussed which include spectrum, anisotropy in arrival directions, chemical composition analyses, and limits on neutrino and photon fluxes. A review of the Observatory detection systems will be presented. Auger has started the construction of its second phase which encompasses antennae for radio detection of cosmic rays, high-elevation telescopes, and surface plus muon detectors. Details will be presented on the latter, AMIGA (Auger Muons and Infill for the Ground Array), an Auger project consisting of 85 detector pairs each one composed of a surface water-Cherenkov detector and a buried muon counter. The detector pairs are arranged in an array with spacings of 433 and 750 m in order to perform a detailed study of the 10{sup 17} eV to 10{sup 19} eV spectrum region. Preliminary results on the performance of the 750 m array of surface detectors and the first muon counter prototype will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study on ion-irradiation-induced ferromagnetism in FeRh intermetallic compound by means of magnetic Compton scattering

The magnetic Compton profiles of Fe-50 at. % Rh intermetallic compound were measured to study the ferromagnetism induced by 200 MeV Xe ion irradiation. The magnetic effect at 50 K increases with increasing the ion-fluence. The analysis of the experimental result revealed that the values of spin moment induced by the irradiation were close to the values of magnetization obtained by a superconducting quantum interference device magnetometer, suggesting that the ion irradiation mainly induces the spin magnetic moment. The difference in magnetic Compton profiles between the irradiation-induced ferromagnetism and the intrinsic ferromagnetism in pure Fe is also discussed.

36 MATERIALS SCIENCE↗

Results from the High Resolution Fly's Eye Experiment

The High Resolution Fly's Eye (HiRes) Experiment operated two fluorescence detector sites in the western Utah desert between 1997 and 2006. The HiRes results on the cosmic ray spectrum are consistent with the GZK Suppression predicted at 10{sup 19.8} eV and observe an ankle structure at 10{sup 18.5} eV. These spectral features are consistent with a proton-dominated composition for cosmic rays at the highest energies. The HiRes composition studies of both the mean and the variance of the shower maximum depth (X{sub max}) also give results that are completely consistent with a predominately protonic composition, and inconsistent with heavy nuclei such as iron. We also report on the result of anisotropy studies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CIRCULAR POLARIZATION OF PULSAR WIND NEBULAE AND THE COSMIC-RAY POSITRON EXCESS

Recent observations by the PAMELA and AMS-02 telescopes have uncovered an anomalous rise in the positron fraction at energies above 10 GeV. One possible explanation for this excess is the production of primary electron/positron pairs through electromagnetic cascades in pulsar magnetospheres. This process results in a high multiplicity of electron/positron pairs within the wind-termination shock of pulsar wind nebulae (PWNe). A consequence of this scenario is that no circular polarization should be observed within PWNe, since the contributions from electrons and positrons exactly cancel. Here we note that current radio instruments are capable of setting meaningful limits on the circular polarization of synchrotron radiation in PWNe, which observationally test the model for pulsar production of the local positron excess. The observation of a PWN with detectable circular polarization would cast strong doubt on pulsar interpretations of the positron excess, while observations setting strong limits on the circular polarization of PWNe would lend credence to these models. Finally, we indicate which PWNe are likely to provide the best targets for observational tests of the AMS-02 excess.

79 ASTRONOMY AND ASTROPHYSICS↗

Global analysis of data on the spin-orbit-coupled A {sup 1{Sigma}}{sub u}{sup +} and b {sup 3{Pi}}{sub u} states of Cs{sub 2}

We present experimentally derived potential curves and spin-orbit interaction functions for the strongly perturbed A {sup 1{Sigma}}{sub u}{sup +} and b {sup 3{Pi}}{sub u} states of the cesium dimer. The results are based on data from several sources. Laser-induced fluorescence Fourier transform spectroscopy (LIF FTS) was used some time ago in the Laboratoire Aime Cotton primarily to study the X {sup 1{Sigma}}{sub g}{sup +} state. More recent work at Tsinghua University provides information from moderate resolution spectroscopy on the lowest levels of the b {sup 3{Pi}}{sub 0u}{sup {+-}} state as well as additional high-resolution data. From Innsbruck University, we have precision data obtained with cold Cs{sub 2} molecules. Recent data from Temple University was obtained using the optical-optical double resonance polarization spectroscopy technique, and finally, a group at the University of Latvia has added additional LIF FTS data. In the Hamiltonian matrix, we have used analytic potentials (the expanded Morse oscillator form) with both finite-difference (FD) coupled-channel and discrete variable representation (DVR) calculations of the term values. Fitted diagonal and off-diagonal spin-orbit functions are obtained and compared with ab initio results from Temple and Moscow State universities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

{gamma}-ray spectroscopy of {sub 17}{sup 38}Cl using grazing reactions

Excited states of {sub 17}{sup 38}Cl{sub 21} were populated in binary grazing reactions during the interaction of a beam of {sub 16}{sup 36}S{sub 20} ions of energy 215 MeV with a {sub 82}{sup 208}Pb{sub 126} target. The combination of the PRISMA magnetic spectrometer and the CLARA {gamma}-ray detector array was used to identify the reaction fragments and to detect their decay via {gamma}-ray emission. A level scheme for {sup 38}Cl is presented and discussed within the context of the systematics of neighboring nuclei and is compared with the results of state-of-the-art shell-model calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of K{sup -}p radiative capture to gammaLAMBDA and gammaSIGMA{sup 0} for p{sub K}{sup -} between 514 and 750 MeV/c

Differential cross sections for K{sup -} radiative capture in flight on the proton, leading to the gammaLAMBDA and gammaSIGMA{sup 0} final states, have been measured at eight K{sup -} momenta between 514 and 750 MeV/c. The data were obtained with the Crystal Ball multiphoton spectrometer installed at the separated K/pi beam line C6 of the BNL Alternating Gradient Synchrotron. The results substantially improve the existing experimental data available for studying radiative decays of excited hyperon states. An exploratory theoretical analysis is performed within the Regge-plus-resonance approach. According to this analysis, the gammaSIGMA{sup 0} final state is dominated by hyperon-resonance exchange and hints at an important role for a resonance in the mass region of 1700 MeV. In the gammaLAMBDA final state, in contrast, the resonant contributions account for only half the strength, and the data suggest the importance of a resonance in the mass region of 1550 MeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental study of the {gamma}p{yields}{eta}p reaction with the Crystal Ball detector at the Mainz Microtron (MAMI-C)

The {gamma}p{yields}{eta}p reaction has been measured with the Crystal Ball and TAPS multiphoton spectrometers in the energy range from the production threshold of 707 MeV to 1.4 GeV (1.49{<=}W{<=}1.87 GeV). Bremsstrahlung photons produced by the 1.5-GeV electron beam of the Mainz Microtron MAMI-C and momentum analyzed by the Glasgow tagging spectrometer were used for the {eta}-meson production. Our accumulation of 3.8x10{sup 6} {gamma}p{yields}{eta}p{yields}3{pi}{sup 0}p{yields}6{gamma}p events allows a detailed study of the reaction dynamics. The {gamma}p{yields}{eta}p differential cross sections were determined for 120 energy bins and the full range of the production angles. Our data show a dip near W=1680 MeV in the total cross section caused by a substantial dip in {eta} production at forward angles. The data are compared to predictions of previous SAID and MAID partial-wave analyses and to the latest SAID and MAID fits that included our data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Revisit the radiative decays of J/{psi} and {psi}{sup '}{yields}{gamma}{eta}{sub c}({gamma}{eta}{sub c}{sup '})

With the new measurements of J/{psi} and {psi}{sup '}{yields}{gamma}{eta}{sub c}({gamma}{eta}{sub c}{sup '}) from the CLEO and BES-III collaboration, we reinvestigate the intermediate meson loop (IML) contributions to these radiative decays in association with the quark model M1 transitions in an effective Lagrangian approach. It shows that the ''unquenched'' effects due to the intermediate hadron loops can be better quantified by the new data for J/{psi}{yields}{gamma}{eta}{sub c}. Although the IML contributions are relatively small in J/{psi}{yields}{gamma}{eta}{sub c}, they play a crucial role in {psi}{sup '}{yields}{gamma}{eta}{sub c}({gamma}{eta}{sub c}{sup '}). A prediction for the IML contributions to {psi}(3770){yields}{gamma}{eta}{sub c}({gamma}{eta}{sub c}{sup '}) is made. Such unquenched effects allow us to reach a coherent description of those three radiative transitions, and gain some insights into the underlying dynamics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thermal and suprathermal plasma densities in the outer magnetosphere

By using the low-frequency cutoff of electromagnetic noise trapped in the magnetosphere at frequencies above the local plasma frequency, it is now possible to make very accurate electron density measurements in the low density region between the magnetopause and plasmapause. This technique for measuring the total plasma density has been used, together with measurements of the suprathermal proton intensities with the Lepedea instrumentation on the Imp 6 spacecraft, to determine the thermal proton densities in the region between the plasmapause and magnetopause. Usually, the high-energy tail of the thermal proton distribution is sufficient intense to be detected at low energies within the Lepedea energy range. When the high-energy tail of the thermal distribution can be detected, it is possible to determine the temperature of the thermal protons. The temperature in a typical case is found to be 80,000 K. This high temperature for the thermal protons, which are presumably of ionospheric origin, agrees with earlier Ogo 5 measurements reported by Serbu and Maier (1970).

Gurnett, D. A.↗

Crab Flares and Magnetic Reconnection in Pulsar Winds

The striped winds of rotation-powered pulsars are ideal sites for magnetic reconnection. The magnetic fields of the wind near the current sheet outside the light cylinder alternate polarity every pulsar period and eventually encounter a termination shock. Magnetic reconnection in the wind has been proposed as a mechanism for transferring energy from electromagnetic fields to particles upstream of the shock (the "sigma" problem), but it is not clear if, where and how this occurs. Fermi and AGILE have recently observed powerful gamma-ray flares from the Crab nebula, which challenge traditional models of acceleration at the termination shock. New simulations are revealing that magnetic reconnection may be instrumental in understanding the Crab flares and in resolving the "sigma" problem in pulsar wind nebulae.

Harding, Alice K.↗

L’Ralph Integration and Testing

This paper describes the plans, flows, key facilities, components and equipment necessary to fully integrate, functionally test, qualify and calibrate the L’Ralph instrument on the Lucy observatory. Lucy is currently in the final design and fabrication phase (phase C) of mission development. It is scheduled to launch out of Cape Canaveral, Florida, in October 2021. Lucy will be the first space mission to study the Trojan asteroids associated with Jupiter, that are thought to be remnants of the primordial material that formed the outer planets. Lucy will fly by and carry out remote sensing on six different Trojan asteroids. The mission takes its name from the fossilized human ancestor (called “Lucy” by her discoverers) whose skeleton provided unique insight into humanity's evolution. Likewise, the Lucy mission will revolutionize our knowledge of planetary origins and the formation of the solar system. L’Ralph is one of the instruments on Lucy and it is provided by the NASA Goddard Space Flight Center (GSFC). L’Ralph is a combined multi-band visible imager (the Multi-spectral Visible Imaging Camera, MVIC, 0.4-0.85 microns) and wedge-filter infrared spectrometer (Linear Etalon Imaging Spectral Array, LEISA, 1-3.6 microns). LEISA will allow the team to look for the absorption lines that serve as the fingerprints for different silicates, ices and organics that likely will be on the surface of the Trojan asteroids. MVIC will take color images of the Trojan asteroid targets, and help determine how active they are. This paper will focus on the Integration and Test (I&T) activities for L’Ralph while it is at the NASA GSFC. L’Ralph has two assemblies, the telescope detector assembly (TDA) and main electronics box (MEB). The TDA is a single telescope feeding two focal planes, MVIC and LEISA. L’Ralph integration consists of assembly and alignment of the telescope, electronics box integration, thermal systems integration and the final assembly and testing. This I&T phase will be followed by the L’Ralph calibration and characterization, environmental tests which include electromagnetic interference (EMI)/electromagnetic compatibility (EMC), vibration with sine sweep, acoustics, shock, thermal balance, thermal vacuum, mass properties and center of gravity determination. This paper will briefly discuss L’Ralph shipment and delivery to the spacecraft vendor for observatory level I&T as well as some launch preparation activities.

Spaceflight Instruments↗

Theory, observations, and simulations of kinetic entropy in a magnetotail electron diffusion region

In this work, we examine velocity-space kinetic entropy, a spatially local measure of entropy for systems out of thermal equilibrium, during an encounter of an electron diffusion region at a magnetic reconnection site in Earth’s magnetotail by the Magnetospheric Multiscale (MMS) mission. We start by generalizing the theory of kinetic entropy to the case of non-uniform velocity space grids and transforming the equations into spheri- cal energy coordinates useful to experimental plasma detectors. The theory is then applied to MMS data and compared to particle-in-cell simulations of reconnection. We demonstrate that the entropy-based non-Maxwellianity measure from the MMS data is of sufficiently high precision to reliably identify non-Maxwellian distributions and therefore the measurements when kinetic effects are most significant. By comparing two different non-Maxwellian measures, we show that total entropy density suffers from “information loss” because it lacks a dependence on the velocity space grid, and so has lost information about how well a distribution function is resolved. Local velocity-space kinetic entropy density recovers this information. We quantify information loss and argue that the considerations needed to minimize it are crucial for instruments designed to measure distribution functions in situ.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of the radiation energy in the radio signal of extensive air showers as a universal estimator of cosmic-ray energy

We measure the energy emitted by extensive air showers in the form of radio emission in the frequency range from 30 to 80 MHz. Exploiting the accurate energy scale of the Pierre Auger Observatory, we obtain a radiation energy of 15.8 ± 0.7 (stat) ± 6.7 (sys) MeV for cosmic rays with an energy of 1 EeV arriving perpendicularly to a geomagnetic field of 0.24 G, scaling quadratically with the cosmic-ray energy. A comparison with predictions from state-of-the-art first-principle calculations shows agreement with our measurement. The radiation energy provides direct access to the calorimetric energy in the electromagnetic cascade of extensive air showers. Comparison with our result thus allows the direct calibration of any cosmic-ray radio detector against the well-established energy scale of the Pierre Auger Observatory.

47 OTHER INSTRUMENTATION↗

Single-crystal sapphire tubes as economical probes for optical pyrometry in harsh environments

One-end-sealed single-crystal sapphire tubes are presented as a simple, robust, and economical alternative for bulky lightpipe probes. Thermal radiation from a blackbody cavity created at the inner surface of the sealed end is gathered by a simple lens-based collecting system and transmitted via optical fiber to the remote detection unit. Simplicity and applicability of the concept are demonstrated by the combination of commercially available sapphire tubes with a common optical pyrometer. Radiation thermometers with sapphire tubes as invasive probes can be useful for applications requiring immunity to electromagnetic interference, resistance to harsh environments, simple replacement in the case of failure, and enhanced mechanical firmness, enabling wider range probe positioning inside the medium of interest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of Electromagnetic Scattering From a Dihedral Cut Into a Sphere Using Vector Spherical Harmonics

Proper calibration or verification of the calibration of fully - polarimetric radar requires more than a simple specular target, such as a conducting sphere or corner reflector. The dihedral reflector is a useful radar - scattering target for calibrating the polarization response of a radar system, because it possesses the ability to change the direction of the scattered electric - field vector in a special way, while a sphere or trihedral target does not. However, the scattered electromagnetic field of a sphere can be computed with arbitrary precision using the well - known Mie series, which is obtained by expanding the scattered field as a series of vector spherical harmonics. In contrast, the computation of the scattered electromagnetic field of dihedral reflectors typically relies on numerical methods or various approximate solutions of Maxwell's equations. Precision calibration of wide - bandwidth polarimetric radar has not been adequately achieved for some applications using this approach. This report describes a method for computing the scattered electromagnetic field of a specially shaped dihedral, derived through the application of a series expansion in vector spherical harmonics, with the goal of achieving the same precision that is available for the sphere.

47 OTHER INSTRUMENTATION↗