Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Development of neutron spectrometer toward deuterium plasma diagnostics in LHD

Neutron spectrometer based on coincident counting of associated particles has been developed for deuterium plasma diagnostics on Large Helical Device (LHD) at the National Institute for Fusion Science. Efficient detection of 2.5 MeV neutron with high energy resolution would be achievable by coincident detection of a scattered neutron and a recoiled proton associated with an elastic scattering of incident neutron in a plastic scintillator as a radiator. The calculated neutron spectra from deuterium plasma heated by neutral beam injection indicate that the energy resolution of better than 7% is required for the spectrometer to evaluate energetic deuterium confinement. By using a prototype of the proposed spectrometer, the energy resolution of 6.3% and the detection efficiency of 3.3x10{sup -7} count/neutron were experimentally demonstrated for 2.5 MeV monoenergetic neutron, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Concept of a charged fusion product diagnostic for NSTX

The concept of a new diagnostic for NSTX to determine the time dependent charged fusion product emission profile using an array of semiconductor detectors is presented. The expected time resolution of 1-2 ms should make it possible to study the effect of magnetohydrodynamics and other plasma activities (toroidal Alfven eigenmodes (TAE), neoclassical tearing modes (NTM), edge localized modes (ELM), etc.) on the radial transport of neutral beam ions. First simulation results of deuterium-deuterium (DD) fusion proton yields for different detector arrangements and methods for inverting the simulated data to obtain the emission profile are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New plasma measurements with a multichannel millimeter-wave fluctuation diagnostic system in the DIII-D tokamak (invited)

A novel multichannel, tunable Doppler backscattering (DBS)/reflectometry system has recently been developed and applied to a variety of DIII-D plasmas. Either DBS or reflectometry can be easily configured for use in a wide range of plasma conditions using a flexible quasi-optical antenna system. The multiple closely spaced channels, when combined with other fluctuation diagnostic systems, have opened up new measurements of plasma properties. For example, the toroidal and fine-scale radial structure of coherent plasma oscillations, such as geodesic acoustic modes, have been probed simultaneously in the core of high temperature plasmas by applying correlation analysis between two toroidally separated DBS systems, as well as within the multichannel array. When configured as a reflectometer, cross-correlation with electron cyclotron emission radiometry has uncovered detailed information regarding the crossphase relationship between density and temperature fluctuations. The density-temperature crossphase measurement yields insight into the physics of tokamak turbulence at a fundamental level that can be directly compared with predictions from nonlinear gyrokinetic simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnostics for the Plasma Liner Experiment

The goal of the Plasma Liner Experiment (PLX) is to explore and demonstrate the feasibility of forming imploding spherical ''plasma liners'' via merging high Mach number plasma jets to reach peak liner pressures of {approx}0.1 Mbar using {approx}1.5 MJ of initial stored energy. Such a system would provide HED plasmas for a variety of fundamental HEDLP, laboratory astrophysics, and materials science studies, as well as a platform for experimental validation of rad-hydro and rad-MHD simulations. It could also prove attractive as a potential standoff driver for magnetoinertial fusion. Predicted parameters from jet formation to liner stagnation cover a large range of plasma density and temperature, varying from n{sub i}{approx}10{sup 16} cm{sup -3}, T{sub e}{approx_equal}T{sub i}{approx}1 eV at the plasma gun mouth to n{sub i}>10{sup 19} cm{sup -3}, T{sub e}{approx_equal}T{sub i}{approx}0.5 keV at stagnation. This presents a challenging problem for the plasma diagnostics suite which will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Broadband notch filter design for millimeter-wave plasma diagnostics

Notch filters are integrated in plasma diagnostic systems to protect millimeter-wave receivers from intensive stray radiation. Here we present a design of a notch filter with a center frequency of 140 GHz, a rejection bandwidth of {approx}900 MHz, and a typical insertion loss below 2 dB in the passband of {+-}9 GHz. The design is based on a fundamental rectangular waveguide with eight cylindrical cavities coupled by T-junction apertures formed as thin slits. Parameters that affect the notch performance such as physical lengths and conductor materials are discussed. The excited resonance mode in the cylindrical cavities is the fundamental TE{sub 11}. The performance of the constructed filter is measured using a vector network analyzer monitoring a total bandwidth of 30 GHz. We compare the measurements with numerical simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calculation of spatial response of 2D beam emission spectroscopy diagnostic on MAST

The beam emission spectroscopy (BES) turbulence diagnostic on MAST is to be upgraded in June 2010 from a one-dimensional trial system to a two-dimensional imaging system (8 radialx4 poloidal channels) based on a newly developed avalanche photodiode array camera. The spatial resolution of the new system is calculated in terms of the point spread function to account for the effects of field-line curvature, observation geometry, the finite lifetime of the excited state of the beam atoms, and beam attenuation and divergence. It is found that the radial spatial resolution is {approx}2-3 cm and the poloidal spatial resolution {approx}1-5 cm depending on the radial viewing location. The absolute number of detected photons is also calculated, hence the photon noise level can be determined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Grating spectrometer system for beam emission spectroscopy diagnostics using high-energy negative-ion-based neutral beam injection on LHD

A beam emission spectroscopy (BES) system was developed for density gradient and fluctuation diagnostics in the Large Helical Device (LHD). In order to cover the large Doppler shift of the H{alpha} beam emission because of the high-energy negative-ion-based neutral beam atom (acceleration voltage V{sub acc}=90-170 kV) and the large motional Stark splitting due to the large vxB field (magnetic field B=3.0 T), a grating spectrometer was used instead of a conventional interference filter system. The reciprocal linear dispersion is about 2 nm/mm, which is sufficient to cover the motional Stark effect spectra using an optical fiber with a diameter of 1 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improvements of data quality of the LHD Thomson scattering diagnostics in high-temperature plasma experiments

In Large Helical Device (LHD) experiments, an electron temperature (T{sub e}) more than 15 keV has been observed by the yttrium-aluminum-garnet (YAG) laser Thomson scattering diagnostic. Since the LHD Thomson scattering system has been optimized for the temperature region, 50 eV{<=}T{sub e}{<=}10 keV, the data quality becomes worse in the higher T{sub e} region exceeding 10 keV. In order to accurately determine T{sub e} in the LHD high-T{sub e} experiments, we tried to increase the laser pulse energy by simultaneously firing three lasers. The technique enables us to decrease the uncertainties in the measured T{sub e}. Another signal accumulation method was also tested. In addition, we estimated the influence of high-energy electrons on T{sub e} obtained by the LHD Thomson scattering system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interpretation and implementation of an ion sensitive probe as a plasma potential diagnostic

An ion sensitive probe (ISP) is developed as a robust diagnostic for measuring plasma potentials ({Phi}{sub P}) in magnetized plasmas. The ISP relies on the large difference between the ion and electron gyroradii ({rho}{sub i}/{rho}{sub e}{approx}60) to reduce the electron collection at a collector recessed behind a separately biased wall distance {approx}{rho}{sub i}. We develop a new ISP method to measure the plasma potential that is independent of the precise position and shape of the collector. {Phi}{sub P} is found as the wall potential when charged current to the probe collector vanishes during the voltage sweep. The plasma potentials obtained from the ISP match {Phi}{sub P} measured with an emissive probe over a wide range of plasma conditions in a small magnetized plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma diagnostics for investigating extreme ultraviolet light sources

Plasma temperature and density diagnostics are crucial for lithographic applications of extreme ultraviolet light sources. One widely used technique employs line intensity ratios of successively charged ion states to determine the ion temperature (T{sub ionz}). This work comprises a detailed ''stress-test'' of the applied technique, where space and time resolved emission in laser-produced plasmas were studied, using a Nd:yttrium aluminum garnet laser pulse incident on an aluminum target in the 26.5-32.5 nm range. Detailed hydrodynamic simulations also investigate the dependency of ion temperature on electron density and the charge states for various line combinations (Al VI/V, Al VII/VI, Al VIII/VII, Al IX/VIII, and Al X/IX).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electron cyclotron emission diagnostics on KSTAR tokamak

A new electron cyclotron emission (ECE) diagnostics system was installed for the Second Korea Superconducting Tokamak Advanced Research (KSTAR) campaign. The new ECE system consists of an ECE collecting optics system, an overmode circular corrugated waveguide system, and 48 channel heterodyne radiometer with the frequency range of 110-162 GHz. During the 2 T operation of the KSTAR tokamak, the electron temperatures as well as its radial profiles at the high field side were measured and sawtooth phenomena were also observed. We also discuss the effect of a window on in situ calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High energy photocathodes for laser fusion diagnostics

Laser fusion experiments at the National Ignition Facility require time-resolved x-ray images of the ignition target self-emission. The photon energies are expected to be greater than 10 keV. Photoemission quantum yield measurement data and photoelectron energy spectrum data are presently unavailable in this photon energy range, but are essential in the design of x-ray imaging diagnostics. We developed an apparatus to measure the quantum efficiency of primary and secondary photoelectron emission and to estimate the energy spectrum of the secondary photoelectrons. The apparatus has been tested using photon energies less than 10 keV to allow comparisons with prior work. A method for preparing photocathodes with geometrically enhanced photoefficiency has been developed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-tracer spectroscopy diagnostics of temperature profile in the conduction layer of a laser-ablated plastic foil

A technique that combines the diagnostics of electron temperature history and the measurements of ablation velocity with two-tracer x-ray spectroscopy has been developed for diagnosing the temperature profiles in the thermal conduction layers of laser-ablated plastic foils. The electron temperature in the plastic ablator was diagnosed using the isoelectronic line ratios of Al Ly{alpha} line to Mg Ly{alpha} line, emitted from a tracer layer of Al/Mg mixture buried under the ablator. The ablation velocity was inferred from the time delay between the onset time of x-ray line emissions from Al and Mg tracer layers buried at two depths in the ablator, respectively. From the measured electron temperatures and ablation velocity, the electron temperature profile in the conduction layer was inferred. The measured temperature profile was compared with the simulated one and reasonable agreement was found.

36 MATERIALS SCIENCE↗

Spectroscopic, imaging, and probe diagnostics of laser plasma plumes expanding between confining surfaces

Laser plasma plumes were generated in aluminum rectangular cavities of fixed depth (6 mm) and varying height (2.0, 1.5, and 1.0 mm). Space and time resolved visible emission spectroscopy, gated intensified visible imaging, and Langmuir probe diagnostics were utilized to diagnose the evolution of the confined plasma plumes in comparison to freely expanding plasma plume generated from ablation of a planar target. The constrained plasma behavior displayed a multiphase history. Early stage interactions (t<100 ns) resulted in enhanced continuum and line emission, shockwave formation and plasma plume rebound. Later phase, long duration plasma-surface interactions (t>160 ns) resulted in sustained 'decay', i.e., a rapid termination of continuum emission, in concert with decreases in peak electron density (N{sub e}) and plasma temperature (T). This later phase originates from loss mechanisms which bleed the plasma plume of thermal energy and charged particles. These loss mechanisms increase in magnitude as the duration of the plasma-surface interaction increases. The transition from enhancement phase, originating from hydrodynamic containment, and plasma-surface collisions, to decay phase is described and occurs for each cavity at a different point in the space time history.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of statistical characterization of radial turbulence in the edge of HuanLiuqi-2A plasma with visible spectroscopy diagnostic

The radial motion and structure of edge turbulence in the HuanLiuqi-2A tokamak [Y. Liu et al., Nucl. Fusion 45, S239 (2005)] was measured with visible spectroscopy diagnostic system; the radial turbulence propagation velocity and correlation length were evaluated by time-delay correlation technique and there were typically V{sub r}=0.4-1 km/s and L{sub r}=2-6 cm, respectively. The edge intermittent events accompanied with turbulence have been observed in plasma edge and propagated outward radially; especially through the scrape-off layer, the fluctuation signals of D{sub {alpha}} exhibit strong asymmetric probability distribution functions (PDFs). Their propagation trajectories and radial velocity PDFs were inferred from a special correlation technique and the results indicated the radial velocity of intermittent event depends on its amplitude. Some comparisons with previous measurements and models were also presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hard x-ray correlation analysis as a diagnostic tool for the measurement of magnetic turbulence in tokamaks

A diagnostic has been developed for the measurement and characterization of the magnetic turbulence occurring in the core region of a tokamak. A specially shielded detector looking in the tangential direction has been employed to measure the thin target bremsstrahlung from the core plasma. The thick target bremsstrahlung from the limiter is also recorded at the same time. Auto- and cross-correlation analyses have been shown to yield, respectively, the stochasticity of the magnetic fluctuations in the core region and the consequent diffusion coefficient of the nonthermal electrons. The measured stochasticity bears a relationship with the diffusion coefficient. Data obtained from internal magnetic probes corroborate the above trend but the hard x-ray measurement data are shown to be more reliable than those obtained from magnetic probes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling of Hydrogen Line Shapes for the Diagnostic of ITER

The state of art of the line shape modeling techniques involved in tokamak edge plasma spectroscopy is reported, in the context of the preparation for ITER. Hydrogen spectra are calculated assuming a line-of-sight crossing a 2D-plasma background obtained from numerical simulations. The Doppler, Zeeman and Stark effects are retained. Ion dynamics effects are accounted for by using the numerical simulation method. The possibility for a line shape-based diagnostic of the ITER divertor plasma is examined through fittings of simulated spectra and comparison with the input plasma fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of scrape-off layer turbulence simulations with experiments using a synthetic gas puff imaging diagnostic

A synthetic gas puff imaging (GPI) diagnostic has been added to the scrape-off layer turbulence (SOLT) simulation code, enabling comparisons with GPI data from the National Spherical Torus Experiment (NSTX) [M. Ono et al., Nucl. Fusion 40, 557 (2000)]. The edge and scrape-off layer are modeled in the radial and poloidal (bidirectional) dimensions of the outboard midplane region of NSTX. A low-confinement mode discharge is simulated by choosing reference parameters, including radial density and temperature profiles, to be consistent with those of the shot (no. 112825). NSTX and simulation GPI data are submitted to identical analyses. It is demonstrated that the level of turbulent fluctuations in the simulation may be adjusted to give synthetic GPI radial intensity profiles similar to those of the experiment; for a ''best-case'' simulation, SOLT and NSTX probability distribution functions of blob radial locations, widths, and GPI image velocities are compared. For the simulation, synthetic GPI image velocity and fluid convection (ExB) velocity are compared and contrasted.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗