Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Criticality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

ANL Critical Assembly Covariance Matrix Generation

This report discusses the generation of a covariance matrix for selected critical assemblies that were carried out by Argonne National Laboratory (ANL) using four critical facilities-all of which are now decommissioned. The four different ANL critical facilities are: ZPR-3 located at ANL-West (now Idaho National Laboratory- INL), ZPR-6 and ZPR-9 located at ANL-East (Illinois) and ZPPr located at ANL-West.

97 MATHEMATICS AND COMPUTING↗

Development of a Water Based, Critical Flow, Non-Vapor Compression cooling Cycle

Expansion of a high-pressure liquid refrigerant through the use of a thermostatic expansion valve or other device is commonplace in vapor-compression cycles to regulate the quality and flow rate of the refrigerant entering the evaporator. In vapor-compression systems, as the condensed refrigerant undergoes this expansion, its pressure and temperature drop, and part of the liquid evaporates. We (researchers at Kansas State University) are developing a cooling cycle that instead pumps a high-pressure refrigerant through a supersonic converging-diverging nozzle. As the liquid refrigerant passes through the nozzle, its velocity reaches supersonic (or critical-flow) conditions, substantially decreasing the refrigerant’s pressure. This sharp pressure change vaporizes some of the refrigerant and absorbs heat from the surrounding conditions during this phase change. Due to the design of the nozzle, a shockwave trips the supersonic two-phase refrigerant back to the starting conditions, condensing the remaining vapor. The critical-flow refrigeration cycle would provide space cooling, similar to a chiller, by running a secondary fluid such as water or glycol over one or more nozzles. Rather than utilizing a compressor to raise the pressure of the refrigerant, as in a vapor-cycle system, the critical-flow cycle utilizes a high-pressure pump to drive refrigerant liquid through the cooling cycle. Additionally, the design of the nozzle can be tailored for a given refrigerant, such that environmentally benign substances can act as the working fluid. This refrigeration cycle is still in early-stage development with prototype development several years away. The complex multi-phase flow at supersonic conditions presents numerous challenges to fully understanding and modeling the cycle. With the support of DOE and venture-capital investors, initial research was conducted at PAX Streamline, and later, at Caitin. We (researchers at Kansas State University) have continued development of the cycle and have gained an in-depth understanding of the governing fundamental knowledge, based on the laws of physics and thermodynamics and verified with our testing results. Through this research, we are identifying optimal working fluid and operating conditions to eventually demonstrate the core technology for space cooling or other applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Criticality Safety Evaluation on Generic Fissionable Materia Operations with up to 65 Grams Pu-239

This assessment establishes the criticality safety technical basis for generic fissionable material operations with up to 65 grams Pu-239 in various locations with all moderators and reflectors (including superior moderators and reflectors). These generic fissionable material operations are shown to be criticality safe with inadvertent criticality being incredible (or beyond extremely likely). Therefore, no controls on moderators and reflectors are required.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Methodology for Sensitivity and Uncertainty-Based Criticality Safety Validation

Monte Carlo radiation transport software is used extensively for determining the effective multiplication factor k of fissionable systems towards assessing the criticality safety of operations. Understanding the predictive capability of the Monte Carlo software and nuclear data libraries for calculations of specific applications is vital towards making these assessments. Recently, sensitivity and uncertainty (S/U) methods have been developed for this purpose. A computational tool has been developed that uses the S/U methods with MCNP6 to select critical experiment benchmarks that have similar sources of computational bias, and extreme value theory is then used to determine suitable and conservative calculational margins. The S/U techniques are then used to perform nuclear data adjustments, which are then used to determine a suitable margin of subcriticality from cross section uncertainties. This document gives an overview of the theory of S/U methods used for criticality safety validation. First an overview is given for using the sensitivity coefficients and nuclear co variance data towards determining neutronic similarity factors is then discussed. Next, the extreme value theory (EVT) to determine a calculational margin is given along with how the similarity factors are used in the analysis. Then, the Generalized Linear Least Squares (GLLS) method for performing data adjustment and how that method is used to reject benchmarks and compute adjusted nuclear data uncertainties in k are discussed. Last, a discussion of the margin of subcriticality is given along with how to apply of the GLLS data adjustment methods to quantify the effect of nuclear data variability on k.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron Activation and Thermoluminescent Detector Responses to a Bare Pulse of the CEA Valduc SILENE Critical Assembly

This benchmark experiment was conducted as a joint venture between the US Department of Energy (DOE) and the French Commissariat à l'Energie Atomique (CEA). Staff at the Oak Ridge National Laboratory (ORNL) in the US and the Centre de Valduc in France planned this experiment. The experiment was conducted on October 11, 2010 in the SILENE critical assembly facility at Valduc. Several other organizations contributed to this experiment and the subsequent evaluation, including CEA Saclay, Lawrence Livermore National Laboratory (LLNL), the Y-12 National Security Complex (NSC), Babcock International Group in the United Kingdom, and Los Alamos National Laboratory (LANL). The goal of this experiment was to measure neutron activation and thermoluminescent dosimeter (TLD) doses from a source similar to a fissile solution critical excursion. The resulting benchmark can be used for validation of computer codes and nuclear data libraries as required when performing analysis of criticality accident alarm systems (CAASs). A secondary goal of this experiment was to qualitatively test performance of two CAAS detectors similar to those currently and formerly in use in some US DOE facilities. The detectors tested were the CIDAS MkX and the Rocky Flats NCD-91. These detectors were being evaluated to determine whether they would alarm, so they were not expected to generate benchmark quality data.

Miller, Thomas Martin↗

Final Technical Report on Quantifying Dependability Attributes of Software Based Safety Critical Instrumentation and Control Systems in Nuclear Power Plants

With the current transition from analog to digital instrumentation and control systems in nuclear power plants, the number and variety of software-based systems have significantly increased. The sophisticated nature and increasing complexity of software raises trust in these systems as a significant challenge. The trust placed in a software system is typically termed software dependability. Software dependability analysis faces uncommon challenges since software systems’ characteristics differ from those of hardware systems. The lack of systematic science-based methods for quantifying the dependability attributes in software-based instrumentation as well as control systems in safety critical applications has proved itself to be a significant inhibitor to the expanded use of modern digital technology in the nuclear industry. Dependability refers to the ability of a system to deliver a service that can be trusted. Dependability is commonly considered as a general concept that encompasses different attributes, e.g., reliability, safety, security, availability and maintainability. Dependability research has progressed significantly over the last few decades. For example, various assessment models and/or design approaches have been proposed for software reliability, software availability and software maintainability. Advances have also been made to integrate multiple dependability attributes, e.g., integrating security with other dependability attributes, measuring availability and maintainability, modeling reliability and availability, quantifying reliability and security, exploring the dependencies between security and safety and developing integrated analysis models. However, there is still a lack of understanding of the dependencies between various dependability attributes as a whole and of how such dependencies are formed. To address the need for quantification and give a more objective basis to the review process -- therefore reducing regulatory uncertainty -- measures and methods are needed to assess dependability attributes early on, as well as throughout the life-cycle process of software development. In this research, extensive expert opinion elicitation is used to identify the measures and methods for assessing software dependability. Semi-structured questionnaires were designed to elicit expert knowledge. A new notation system, Causal Mechanism Graphing, was developed to extract and represent such knowledge. The Causal Mechanism Graphs were merged, thus, obtaining the consensus knowledge shared by the domain experts. In this report, we focus on how software contributes to dependability. However, software dependability is not discussed separately from the context of systems or socio-technical systems. Specifically, this report focuses on software dependability, reliability, safety, security, availability, and maintainability. Our research was conducted in the sequence of stages found below. Each stage is further examined in its corresponding chapter. Stage 1 (Chapter 2): Elicitation of causal maps describing the dependencies between dependability attributes. These causal maps were constructed using expert opinion elicitation. This chapter describes the expert opinion elicitation process, the questionnaire design, the causal map construction method and the causal maps obtained. Stage 2 (Chapter 3): Elicitation of the causal map describing the occurrence of the event of interest for each dependability attribute. The causal mechanisms for the “event of interest” were extracted for each of the software dependability attributes. The “event of interest” for a dependability attribute is generally considered to be the “attribute failure”, e.g. security failure. The extraction was based on the analysis of expert elicitation results obtained in Stage 1. Stage 3 (Chapter 4): Identification of relevant measurements. Measures for the “events of interest” and their causal mechanisms were obtained from expert opinion elicitation for each of the software dependability attributes. The measures extracted are presented in this chapter. Stage 4 (Chapter 5): Assessment of the coverage of the causal maps via measures. Coverage was assessed to determine whether the measures obtained were sufficient to quantify software dependability, and what measures are further required. Stage 5 (Chapter 6): Identification of “missing” measures and measurement approaches for concepts not covered. New measures, for concepts that had not been covered sufficiently as determined in Stage 4, were identified using supplementary expert opinion elicitation as well as literature reviews. Stage 6 (Chapter 7): Building of a detailed quantification model based on the causal maps and measurements obtained. Ability to derive such a quantification model shows that the causal models and measurements derived from the previous stages (Stage 1 to Stage 5) can form the technical basis for developing dependability quantification models. Scope restrictions have led us to prioritize this demonstration effort. The demonstration was focused on a critical system, i.e. the reactor protection system. For this system, a ranking of the software dependability attributes by nuclear stakeholders was developed. As expected for this application, the stakeholder ranking identified safety as the most critical attribute to be quantified. A safety quantification model limited to the requirements phase of development was built. Two case studies were conducted for verification. A preliminary control gate for software safety for the requirements stage was proposed and applied to the first case study. The control gate allows a cost effective selection of the duration of the requirements phase.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Criticality Safety Evaluation of the LLNL Inherently Safe Subcritical Assembly (ISSA)

The LLNL Nuclear Criticality Safety Division has developed a training center to illustrate criticality safety and reactor physics concepts through hands-on experimental training. The experimental assembly, the Inherently Safe Subcritical Assembly (ISSA), uses surplus highly enriched research reactor fuel configured in a water tank. The training activities will be conducted by LLNL following the requirements of an Integration Work Sheet (IWS) and associated Safety Plan. Students will be allowed to handle the fissile material under the supervision of LLNL instructors. This report provides the technical criticality safety basis for instructional operations with the ISSA experimental assembly.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

New York Solar Smart DG Hub-Resilient Solar Project: Economic and Resiliency Impact of PV and Storage on New York Critical Infrastructure

Resilient PV, which is solar paired with storage ('solar-plus-storage'), provides value both during normal grid operation and power outages as opposed to traditional solar PV, which functions only when the electric grid is operating. During normal grid operations, resilient PV systems help host sites generate revenue and/or reduce electricity bill charges. During grid outages, resilient PV provides critical emergency power that can help people in need and ease demand on emergency fuel supplies. The combination of grid interruptions during recent storms, the proliferation of solar PV, and the growing deployment of battery storage technologies has generated significant interest in using these assets for both economic and resiliency benefits. This report analyzes the technical and economic viability for resilient PV on three critical infrastructure sites in New York City (NYC): a school that is part of a coastal storm shelter system, a fire station, and a NYCHA senior center that serves as a cooling center during heat emergencies. This analysis differs from previous solar-plus-storage studies by placing a monetary value on resiliency and thus, in essence, modeling a new revenue stream for the avoided cost of a power outage. Analysis results show that resilient PV is economically viable for NYC's critical infrastructure and that it may be similarly beneficial to other commercial buildings across the city. This report will help city building owners, managers, and policymakers better understand the economic and resiliency benefits of resilient PV. As NYC fortifies its building stock against future storms of increasing severity, resilient PV can play an important role in disaster response and recovery while also supporting city greenhouse gas emission reduction targets and relieving stress to the electric grid from growing power demands.

14 SOLAR ENERGY↗

Experiences of Vulnerable Residential Customer Subpopulations with Critical Peak Pricing

DOE decided to co-fund ten utilities to undertake eleven experimentally-designed Consumer Behavior Studies (CBS) that proposed to examine a wide range of the topics of interest to the electric utility industry. Each chosen utility was to design, implement and evaluate their own study in order to address questions of interest both to itself and to its applicable regulatory authority, whose approval was generally necessary for the study to proceed. The DOE Office of Energy Delivery and Electricity Reliability (OE), however, did set guidelines, both in the FOA and subsequently during the contracting period, for what would constitute an acceptable study under the Grant. To assist in ensuring these guidelines were adhered to, OE requested that LBNL act as project manager for these Consumer Behavior Studies to achieve consistency of experimental design and adherence to data collection and reporting protocols across the ten utilities. As part of its role, LBNL formed technical advisory groups (TAG) to separately assist each of the utilities by providing technical assistance in all aspects of the design, implementation and evaluation of their studies. LBNL was also given a unique opportunity to perform a comprehensive, cross-study analysis that uses the customer-level interval meter and demographic data made available by these utilities due to SGIG-imposed reporting requirements, in order to analyze critical policy issues associated with AMI-enabled rates and control/information technology. LBNL will publish the results of these analyses in a series of research reports, of which this is one, that attempt to address critical policy issues relating to a variety of topics including customer acceptance, retention and load response to time-based rates and various forms of enabling control and information technologies. This report extends the existing empirical literature on the experiences of low-income customers exposed to critical peak pricing, and provides the first glimpses into the experiences of the elderly and those who reported being chronically ill. Specifically, we analyzed two of the time-based rate consumer behavior studies, which were co-funded by the Department of Energy as part of the Smart Grid Investment Grant program.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

TCIA Secure Cyber Critical Infrastructure Modernization.

The Sandia National Laboratories (Sandia Labs) tribal cyber infrastructure assurance initiative was developed in response to growing national cybersecurity concerns in the the sixteen Department of Homeland Security (DHS) defined critical infrastructure sectors1. Technical assistance is provided for the secure modernization of critical infrastructure and key resources from a cyber-ecosystem perspective with an emphasis on enhanced security, resilience, and protection. Our purpose is to address national critical infrastructure challenges as a shared responsibility.

97 MATHEMATICS AND COMPUTING↗

Criticality Acccident Alarm System (CAAS) CSG-UM Hybrid Example

Criticality Accident Alarm System calculations combine methods needed for both criticality and shielding calculations. UM may be used for facility details, allowing import of existing facility drawing. CSG used for criticality cells.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Module 10 Hand-Stacking and Remote Approach to Critical Using the Planet Assembly

This talk serves as a training module associated with the hand-stacking and remote approach to critical using the Planet assembly which is part of the criticality safety “hands on” training to be performed at the National Critical Experiments Research Center (NCERC) at the Device Assembly Facility (DAF) located at the Nevada National Security Site (NNSS).

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Excluding Benchmark Statistical Outliers in Nuclear Criticality Safety Validation: A Comparison Study of Upper Subcritical Limits for Plutonium Systems using Whisper-1.1

Neutron transport methods used to establish subcriticality require validation by comparison to critical experiments considered to be benchmarks. Whisper is a sensitivity/uncertainty analysis tool developed to assist with the task of validation in nuclear criticality safety. Details on the Whisper methodology can be found in References 1-3 on the MCNP® reference collection website at https://mcnp.lanl.gov. During the process of validation there can be cases where a benchmark experiment may be found to be a statistical outlier, in which the calculated k-effective value and the experiment k-effective value differ by an amount atypical for similar experiments. A methodology optionally employed by Whisper is the exclusion of statistical outliers based upon the iterative diagonal chi-squared statistical rejection technique. Alternatively, there is an option to include all benchmarks in the Whisper library collection, even those benchmarks found to be statistical outliers, when computing the bias, bias uncertainty and margin of subcriticality (MOS) leading to establishment of the baseline upper subcritical limit (USL). A comparison study has been done to compute USLs with and without statistical outliers in the Whisper benchmark collection to determine what effect rejection of statistical outliers has on the recommended USL. The results show little overall difference in the recommended baseline USLs developed by Whisper when excluding statistical outliers. Additionally, there does not appear to be a clear trend in predicting whether the baseline USL will be higher or lower when rejecting statistical outliers from the benchmark critical experiment collection used for validation.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

IER 489: Critical Unresolved Region Integral Experiment (CURIE) CEDT Phase-2 Final Design

The final design for the CURIE integral benchmark experiment is presented in this report. Measurements will be performed on the Comet vertical assembly machine and include various critical configurations consisting of High Enriched Uranium (HEU) metal plates and Teflon moderator plates surrounded by a thick copper reflector. The various configurations with different Teflon plate thickness planned allow for complimentary measurements with differing nuclear data sensitivity in the Unresolved Resonance Region (URR). Similar to previously performed Zeus experiments, the proposed work will serve to validate vital nuclear data quantities and uncertainties and identify deficiencies in current radiation transport codes. Additionally, it will assess the applicability of optimization approaches to nuclear critical experiment design. The final experiment design is detailed in this report and includes design, optimization, uncertainty and continuous-energy nuclear data sensitivity analysis for the final experimental configurations that will provide the basis for a future benchmark evaluation intended for submission to the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook [1]. This document discusses the method, approach, considerations and final design chosen with conclusions. It also includes cost and schedule. The basis and principles of this document come from the preliminary design report [2]. Section 2 discusses the content and potential impact; section 3 gives an overview of the nuclear data and unresolved resonance region; section 4 gives a summary of the work done during the preliminary design; section 5 discusses the machine learning method and principles used for final design; section 6 summaries the results from final design; section 7 provides conclusions and the range of configurations chosen to carry forward to experiment execution; and section 8 includes a summary of costs.

42 ENGINEERING↗

Creation of a Benchmark Suite for SNL Nuclear Criticality Safety Code Validation (Volume 1 - MCNP)

The Nuclear Criticality Safety Program at Sandia National Laboratories has developed a suite of benchmark problems to be utilized for validation of MCNP6 Version 1.0 with ENDF/B-VII Release 1 cross sections. The benchmark suite covers a broad range of fissile material types, material forms, moderators, reflectors, and neutron energy spectra. It is anticipated that this benchmark suite will cover the vast majority of critical safety applications at SNL. The benchmark suite establishes a Bias and Bias Uncertainty for use in criticality safety analyses. In addition, the Bias and Bias Uncertainty value derived from the benchmark suite using the traditional SNL NCS methodology is demonstrated to be equivalent to the more robust statistical techniques used at many DOE sites.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Data from Rossi-alpha and pulsed neutron prompt neutron time decay measurements at the Oak Ridge Critical Experiments Facility

This report briefly describes the Rossi-alpha and pulsed neutron prompt neutron time decay measurements performed at the Oak Ridge Critical Experiments Facility. This description includes the measurement equipment, type of data, and how to access the actual data from Records Management Services at Oak Ridge National Laboratory and the Nuclear Criticality Safety Benchmark Program (NCSBEP) of the Idaho National Laboratory. Most of the data were acquired between 1960 and 1975 on weapons-grade enriched uranium metal assemblies. Also included are measurements of the same type performed at Los Alamos National Laboratory by Oak Ridge National Laboratory with the JEZEBEL and FLATTOP criticality assemblies and other plutonium metal parts. The purpose of this report is to allow future mining of the data for publication of additional information that can be used to verify calculational methods and nuclear cross sections. These data can be used to create reactor physics benchmarks for the Nuclear Energy Agency’s International Handbook of Evaluated Reactor Physics Experiments. Present calculational methods can be used to directly calculate the measured data. The prompt neutron decay is more neutron spectrum sensitive than other measured quantities, particularly for interacting fissile metal systems where the flight time of neutrons between interacting sections is a large part of the neutron lifetime.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Compatibility of polymers in super-critical carbon dioxide for power generation systems: High level findings for low temperatures and pressure conditions

Polymers such as PTFE (polytetrafluorethylene or Teflon), PEEK (polyetheretherketone), EPDM (ethylene propylene cliene monomer) rubber, Viton, EPR (ethylene propylene rubber), Nylon, Nitrile rubber, and perfluoroelastomers are commonly employed in super critical CO 2 (sCO2) energy conversion systems. O-rings and gaskets made from these polymers face stringent performance conditions such as elevated temperatures, high pressures, pollutants and corrosive humid environments. Critical knowledge gaps about polymer degradation from sCO2 exposure need to be addressed. To understand these effects, we have studied nine commonly used polymers subjected to elevated temperatures under isobaric conditions of sCO2 pressure. The polymers (PEEK, Nylon, PTFE, EPDM, Nitrile rubber, EPR, Neoprene, perfluoroelastomer FF 202 and Viton) were exposed for 1000 hours at 100°C to 25 MPa sCO2 pressure in an autoclave. In a second study, elastomers perfluoroelastomer (FF202) and EPDM were exposed to 25 MPa sCO2 for 1000 hours at 150°C. Samples were extracted for ex-situ characterization at t = 200 hours and then at the completion of the test at t=1000 hours. The polymer samples were examined for physical and chemical changes by Dynamic Mechanical and Thermal Analysis (DMTA), Fourier Transform Infrared (FTIR) spectroscopy, and compression set. Density and mass changes immediately after removal from test and 48 hours later, and optical microscopy techniques were also used. Microcomputer tomography (micro CI) data was generated on select specimens. Super-critical CO 2 effects have been identified as either physical or chemical effects. For each polymer, the dominance of one type of effect over the other was evaluated. Attempts were also made to qualitatively link sCO2 effects such as lowering or increase in glass transition temperatures, storage modulus changes, mass and compression set changes, chemical changes seen in FTIR analyses and blister and void formation seen post-exposure to polymer microstructure-related mechanisms such as plasticization of the polymer matrix, escape of volatiles from the polymer during depressurization, and filler and plasticizer effects on microstructure with rapid depressurization rates.

36 MATERIALS SCIENCE↗

Building the Scientific Basis for Cyber Resilience of Critical Infrastructure

Rigorous methods and models are needed to quantify, measure, and increase the cyber resilience of critical infrastructure. An adversary may exploit vulnerabilities in the vital networks such as industrial control systems (ICS) associated with critical infrastructure (e.g., energy, financial, transportation, security), in order to achieve harmful consequences. In cyber systems, the number of vulnerabilities may be large, the attack surface changes over time, and the problem consists of both technical and non-technical factors (e.g., errors in software and human error). Given this complex and dynamic landscape, strategically mitigating risk is important, where “risk” considers both the probability of an event and the consequences if that event occurs. One way to decrease risk is to address consequences by ensuring that critical infrastructure is resilient. In this context, resilience is characterized by the magnitude and duration of a deviation from targeted performance levels, given a disruption. Increasing resilience decreases the consequences of a successful attack.

97 MATHEMATICS AND COMPUTING↗