Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cost”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Strategic supply system design – a holistic evaluation of operational and production cost for a biorefinery supply chain

Abstract Pioneer cellulosic biorefineries across the United States rely on a conventional feedstock supply system based on one‐year contracts with local growers, who harvest, locally store, and deliver feedstock in low‐density format to the conversion facility. While the conventional system is designed for high biomass yield areas, pilot scale operations have experienced feedstock supply shortages and price volatilities due to reduced harvests and competition from other industries. Regional supply dependency and the inability to actively manage feedstock stability and quality, provide operational risks to the biorefinery, which translate into higher investment risk. The advanced feedstock supply system based on a network of depots can mitigate many of these risks and enable wider supply system benefits. This paper compares the two concepts from a system‐level perspective beyond mere logistic costs. It shows that while processing operations at the depot increase feedstock supply costs initially, they enable wider system benefits including supply risk reduction (leading to lower interest rates on loans), industry scale‐up, conversion yield improvements, and reduced handling equipment and storage costs at the biorefinery. When translating these benefits into cost reductions per liter of gasoline equivalent ( LGE ), we find that total cost reductions between –$0.46 to –$0.21 per LGE for biochemical and –$0.32 to –$0.12 per LGE for thermochemical conversion pathways are possible. Naturally, these system level benefits will differ between individual actors along the feedstock supply chain. Further research is required with respect to depot sizing, location, and ownership structures. Published 2015. This article is a U.S. Government work and is in the public domain in the USA. Biofuels, Bioproducts and Biorefining published by Society of Industrial Chemistry and John Wiley & Sons Ltd.

09 BIOMASS FUELS↗

Cost and profit impacts of modifying stover harvest operations to improve feedstock quality

Biomass quality attributes, and the potential tractability of those attributes, are key to a successful biomass feedstock supply chain, in addition to quantity and price. Modifying harvest operations is one potential approach to managing biomass feedstock quality for corn stover. For example, eliminating raking from stover harvest operations is proposed as an approach to reduce ash content. However, changes in the stover harvest configuration cause changes in per acre profits, per ton costs, and available supply at specified prices. Here we evaluate sensitivity of profit, cost, and supply to conversion from a three–pass to a two–pass stover harvesting configuration as a means to reduce ash content. For all simulated yields, harvest costs are 2–3 per ton cheaper for three–pass versus two–pass systems wherever residue retention coefficients are less than 0.5, and per ton costs for both systems increase dramatically where residue retention coefficients are greater than 0.7. Per acre net returns are greater under all simulated yields wherever residue sustainability retention coefficients are less than 0.6. Under these conditions, farmers lose between 13 and 49 per acre by harvesting with a two–pass rather than a three–pass system. Where competing with stover markets with less stringent quality specifications, meeting ash targets by harvesting with a two–pass system may require higher grower payments of the order of 9–25 per ton to make up for the per acre lost revenue. Here, when solving for the least–cost supply, agronomic simulations suggest about 2/3 of stover is harvested with a three–pass system.

09 BIOMASS FUELS↗

A New Hole Transport Material for Efficient Perovskite Solar Cells With Reduced Device Cost

To realize commercialization of perovskie solar cell (PVSC) technology, it is essential to reduce the device costs while maintaining high power conversion efficiencies (PCEs). So far, the high cost of the most commonly used hole selective material, 2,2′,7,7′‐Tetrakis (N,N‐di‐p‐methoxyphenylamino)‐9,9′‐spirobifluorene (spiro‐OMeTAD), for high‐PCE PVSCs presents a significant obstacle for device cost reduction. In this work, the synthesis and characterization of a new spiro‐OMeTAD derivative hole selective material, 2,6,14‐tris(5′‐(N,N‐bis(4‐methoxyphenyl)aminophenol‐4‐yl)‐3,4‐ethylenedioxythiophen‐2‐yl)‐triptycene (TET) is reported. TET features a three‐dimensional structure consisting of a triptycene core and triarylamine arms linked by 3,4‐ethylenedioxythiophene, facilitating efficient hole transport. Planar PVSCs using TET hole selective layers (HSLs) achieved high fill factors of over 81% and steady‐state efficiencies of up to 18.6%, comparable with that (19.0%) of PVSC using spiro‐OMeTAD HSL. Importantly, the hereby reported efficient PVSCs can be produced with very thin TET HSLs (about 30 nm). Considering the lower laboratory synthesis and purification cost ($123 vs. $500 g −1 ) and thinner HSL (30 vs. 200 nm), the cost for TET on a unit area of one device is 25 times lower than that for high‐purity spiro‐OMeTAD. The device with TET HSL shows good stability under continuous illumination. Therefore, this work makes a significant step forward toward the commercialization of the emerging PVSC technology.

Sun, Yuhao↗

Direct health-care cost of head and neck cancers: a population-based study in north-eastern Italy

Improvements in prognosis of head-and-neck squamous cell carcinoma (HNSCC) have paralleled with an increase in health-care costs, so that an economic evaluation is of growing importance. Presently, most of the evidence is from insurance-based studies in the USA. Between 2007 and 2010, 879 HNSCC patients were identified through the population-based cancer registry of the Friuli Venezia Giulia region, including 266 oral, 187 oropharyngeal, 136 hypopharyngeal, and 290 laryngeal cancers. Health-care costs from diagnosis to treatment initiation and in the following 2 years were retrieved through a record linkage with the regional health data warehouse. This database collected comprehensive health information on all resident citizens. Generalized linear models with a gamma distribution and log-link function were applied to model costs. The average health-care cost from diagnosis up to 2 years after treatment initiation was €20,184 (95% confidence interval: €19,634 − 20,733). Heterogeneity emerged according to cancer site, elective treatment, and retreatment for cancer persistence/recurrence (no: €13,896; yes: €24,599; p < 0.001). An advanced stage was associated with increased costs stage (I: €12,969; II: €18,276; III: €26,229; IV: €25,574; p < 0.001) as the result of treatment complexity and elevated frequency of patients retreatment due to recurrence. These findings further support strategies to diagnose patients at an earlier cancer stage and the accurate definition of diagnostic and treatment pathways, to start treating patients when radical unimodal approach is still feasible. Besides the advantage in prognosis due to timely curative treatments, this would reduce the economic burden of cancer treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A quality-agnostic combinatoric cost estimation model for large-format directed energy deposition metal additive manufacturing

Directed energy deposition (DED) additive manufacturing (AM) processes are amenable to synergistic combination into multi-process AM systems due to similar requirements for automation and energy sources. This work analyzes the economic performance of such DED AM systems from a quality-agnostic combinatoric standpoint with a model that calculates lowest-cost system combinations based on part geometry and process performance metrics. Common DED AM systems research focuses on a single process and does not consider the process, system, and application in the context of all possible system combinations (e.g., the combined set of process selection(s), motion system(s), and process hardware), leading to limited applicability of the resulting DED AM systems to cost-sensitive components such as those found in energy generation applications. The model developed herein incorporates the capital, material, and energy costs associated with DED AM system combinations into a predictive tool for estimating part and system cost, the output of which is intended to guide deployment of finite research and development resources towards DED AM system combinations with the lowest costs and greatest likelihood of economic impact. The DED AM systems identified by this framework may enable domestic production of the large conventionally cast and forged components necessary for energy generation.

Shanafield, Alexandra [ORNL]↗

Cost minimization of deoxygenation for control of Vampirovibrio chlorellavorus in Chlorella sorokiniana cultures

Deoxygenation is a strategy for preventing Vampirovibrio chlorellavorus infection of Chlorella sorokiniana cultures. Deoxygenation cost was minimized by sparging with nitrogen gas for only one hour at the onset of night and relying on naturally-occurring dark-respiration to maintain low oxygen concentrations throughout the night. This technique substantially reduced V. chlorellavorus infection in laboratory co-cultures. The cost of the approach was evaluated in outdoor experiments with one pure water and one pathogen-free C. sorokiniana culture, grown in a 150-L sealed, vented, translucent-polyethylene reactor. Unlike the small laboratory reactors, which were also sealed and vented, the much larger outdoor reactor maintained the dissolved oxygen concentration in the C. sorokiniana culture at near zero concentration throughout the night cycle. This demonstrates that large covered tanks in commercial applications would keep oxygen concentration near zero for the entire night. The total nitrogen sparged, per night, per liter of algal culture, was determined for the 150-L reactor, and used to estimate the cost per m2 for large scale raceways. Onsite nitrogen generators are the most cost-effective method to supply a high flow of nitrogen gas to commercial scale raceways. The cost of deoxygenation treatment ranged from $16/ton AFDW algae for a shallow (2 cm) gravity flow system with 75% harvest prior to deoxygenation to over $1,300/ton for a 20 cm depth raceway with plastic tanks.

59 BASIC BIOLOGICAL SCIENCES↗

Biomass transport cost from field to conversion facility when biomass yield density and road network vary with transport radius

Biomass transport cost from field to a conversion facility is a major component of biofuel production cost. Several studies have provided a general framework, independent of location, for maximising cost competitiveness of bioenergy plants. The majority of these studies assume uniform spatial distribution of biomass and road network, independent of the size of the biorefinery. Although this assumption simplifies the theoretical derivation, it may not be suitable for practical cases. Here, we develop a more generic biomass transport model that allows biomass yield density and road network vary with transport radius, and then derive a formula for determining biomass transport cost, which more accurately represents changes in biomass transport cost with conversion plant capacity. The formula can be used to evaluate locations and investment opportunities in large scale biofuel production.

Biomass availability↗

Model-based optimal design of active cool thermal energy storage for maximal life-cycle cost saving from demand management in commercial buildings

This article provides a method in comprehensive evaluation of cost-saving potential of active cool thermal energy storage (CTES) integrated with HVAC system for demand management in non-residential building. The active storage is beneficial by shifting peak demand for peak load management (PLM) as well as providing longer duration and larger capacity of demand response (DR). In this research, a model-based optimal design method using genetic algorithm is developed to optimize the capacity of active CTES aiming for maximizing the life-cycle cost saving concerning capital cost associated with storage capacity as well as incentives from both fast DR and PLM. In the method, the active CTES operates under a fast DR control strategy during DR events while under the storage-priority operation mode to shift peak demand during normal days. The optimal storage capacities, maximum annual net cost saving and corresponding power reduction set-points during DR event are obtained by using the proposed optimal design method. Lastly, this research provides guidance in comprehensive evaluation of cost-saving potential of CTES integrated with HVAC system for building demand management including both fast DR and PLM.

25 ENERGY STORAGE↗

Multi-facility analysis using metered power data to quantify MRI energy use and utility bill costs across scanner operating modes

This study quantifies the energy consumption of magnetic resonance imaging (MRI) scanners across discrete operating modes during routine clinical workflows, based solely on electrical power measurements. Although previous studies have investigated MRI energy consumption within single hospitals or specific clinical settings, this research provides a broader and more systematic analysis. Researchers analyzed electrical power data and applied a previously developed semi-automatic method for identifying MRI operating modes using load duration curves for 20 MRI scanners across four different U.S. healthcare facilities, encompassing outpatient, inpatient, and mixed-use clinical settings. A key innovation is the inclusion of localized hourly utility rates to estimate costs, a parameter absent in prior literature. Key findings indicate significant variability in energy and cost profiles between weekdays and weekends. Scanner characteristics, including magnet strength, manufacturer, vintage, location, and clinical setting, influenced average daily energy consumption and power thresholds for operating modes. Notably, the clinical setting of a scanner predominantly determines its energy use. For example, the scanners in outpatient facilities consumed more energy. The breakdown of energy usage and costs by operating modes showed scanners spend between 61% and 93% of their time in nonproductive modes, with one outlier spending 34%. Average daily energy use for the scanners in the study ranged from 160 to 1069 kWh, with energy costs ranging from $\$$9 to $\$$149. This study uses an existing framework to quantify MRI energy behavior, leading to insights that can enable improved performance and cost savings across different healthcare environments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Research goals for minimizing the cost of CO 2 capture when using steam methane reforming for hydrogen production

This paper presents a techno-economic assessment of adding state-of-the-art solvent-based CO 2 capture technologies to greenfield steam methane reforming (SMR)-based H 2 production plants and quantifies the impacts of improvements in CO 2 capture technology. Current conventional capture technologies are reviewed, and future technologies in intermediate and long-term scenarios are analyzed. The results show that adding significantly more efficient solvent-based capture technologies leads to an equivalent rate of natural gas consumption as that of a conventional SMR plant without capture, despite capturing most of the CO 2 and producing the same amount of H 2 . Overall, improvements in reboiler duty and reductions in capital costs can significantly reduce the cost of H 2 production and cost of capture. Particularly, the reboiler duty of pre-combustion capture and the capital cost of post-combustion capture have the greatest impact. Based on the results, research goals are suggested. Solvent development is recommended—particularly pre-combustion solvents—for reducing the reboiler duties, and process schemes to reduce the capital costs. Costlier but more efficient solvents can be considered. A sensitivity analysis using natural gas price shows that technological improvements can reduce the impacts of high natural gas prices. The degree of economic feasibility of CO 2 capture increases with improvements to the capture technology.

08 HYDROGEN↗

Comparison of ammonia with methanol, liquefied natural gas and conventional marine transportation fuels through life cycle cost and emissions analysis

This work evaluates ammonia as a potential marine fuel for a SUEZMAX tanker and compares it with methanol, liquefied natural gas, and conventional fuel oils. The motivation arises from the need to identify low-emission, cost-competitive fuel options that can reduce greenhouse gas emissions from international shipping. The central hypothesis is that ammonia produced from renewable energy sources can achieve lower well-to-wake greenhouse gas emissions with varying life cycle costs based on the region. Life cycle assessment and techno-economic analysis were performed for a thirty-year vessel lifetime on two representative trade routes: from Saudi Arabia to Japan and from Saudi Arabia to the Netherlands. Four ammonia production pathways were assessed: natural gas, natural gas with carbon capture, natural gas pyrolysis, and renewable electricity–based synthesis. Results show that wind-based ammonia produced in Saudi Arabia achieved the lowest life cycle well-to-wake greenhouse gas emissions, between 0.58 and 0.64 million metric tons, among all fuels when using regional grid process electricity. With renewable process electricity, ammonia produced from natural gas pyrolysis in Saudi Arabia showed comparable emissions of 0.37 to 0.44 million metric tons with wind-based ammonia of 0.37 to 0.43 million metric tons. Liquefied natural gas exhibited the lowest life cycle cost, between 402 and 412 million United States dollars, and the only negative carbon abatement cost, ranging from −277 to –322 United States dollars per metric ton of greenhouse gas, compared with high sulfur fuel oil. The findings indicate that renewable ammonia offers a promising long-term pathway for reducing shipping emissions, while liquefied natural gas remains the most cost-effective option in the near term.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Utilization of municipal wastewater for cooling in thermoelectric power plants: Evaluation of the combined cost of makeup water treatment and increased condenser fouling

A methodology is presented to calculate the total combined cost (TCC) of water sourcing, water treatment and condenser fouling in the recirculating cooling systems of thermoelectric power plants. The methodology is employed to evaluate the economic viability of using treated municipal wastewater (MWW) to replace the use of freshwater as makeup water to power plant cooling systems. Cost analyses are presented for a reference power plant and five different tertiary treatment scenarios to reduce the scaling tendencies of MWW. Results indicate that a 550 MW sub-critical coal fired power plant with a makeup water requirement of 29.3 ML/day has a TCC of $3.0 - 3.2 million/yr associated with the use of treated MWW for cooling. (All costs USD 2009). This translates to a freshwater conservation cost of $0.29/kL, which is considerably lower than that of dry air cooling technology, $1.5/kL, as well as the 2020 conservation cost target set by the U.S. Department of Energy, $0.74/kL. Results also show that if the available price of freshwater exceeds that of secondary-treated MWW by more than $0.13-0.14/kL, it can be economically advantageous to purchase secondary MWW and treat it for utilization in the recirculating cooling system of a thermoelectric power plant.

20 FOSSIL-FUELED POWER PLANTS↗

Cost Analysis of Plug-In Hybred Electric Vehicles Using GPS-Based Longitudinal Travel Data

Using spatial, longitudinal travel data of 415 vehicles over 3 18 months in the Seattle metropolitan area, this paper estimates the operating costs of plug-in hybrid electric vehicles (PHEVs) of various electric ranges (10, 20, 30, and 40 miles) for 3, 5, and 10 years of payback period, considering different charging infrastructure deployment levels and gasoline prices. Some key findings were made. (1) PHEVs could help save around 60% or 40% in energy costs, compared with conventional gasoline vehicles (CGVs) or hybrid electric vehicles (HEVs), respectively. However, for motorists whose daily vehicle miles traveled (DVMT) is significant, HEVs may be even a better choice than PHEV40s, particularly in areas that lack a public charging infrastructure. (2) The incremental battery cost of large-battery PHEVs is difficult to justify based on the incremental savings of PHEVs operating costs unless a subsidy is offered for largebattery PHEVs. (3) When the price of gasoline increases from $4/gallon to $5/gallon, the number of drivers who benefit from a larger battery increases significantly. (4) Although quick chargers can reduce charging time, they contribute little to energy cost savings for PHEVs, as opposed to Level-II chargers.

Wu, Xing↗

Estimating the implied cost of carbon in future scenarios using a CGE model: The Case of Colorado

We develop a state-level computable general equilibrium (CGE) model that reflects the roles of coal, natural gas, wind, solar, and hydroelectricity in supplying electricity, using Colorado as a case study. Also, we focus on the economic impact of implementing Colorado's existing Renewable Portfolio Standard, updated in 2013. This requires that 25% of state generation come from qualifying renewable sources by 2020. We evaluate the policy under a variety of assumptions regarding wind integration costs and assumptions on the persistence of federal subsidies for wind. Specifically, we estimate the implied price of carbon as the carbon price at which a state-level policy would pass a state-level cost-benefit analysis, taking account of estimated greenhouse gas emission reductions and ancillary benefits from corresponding reductions in criteria pollutants. Our findings suggest that without the Production Tax Credit (federal aid), the state policy of mandating renewable power generation (RPS) is costly to state actors, with an implied cost of carbon of about $17 per ton of CO 2 with a 3% discount rate. Federal aid makes the decision between natural gas and wind nearly cost neutral for Colorado.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Hourly land-use regression models based on low-cost PM monitor data

Highlights: • A network of 23 low-cost PM monitors was deployed across an urban area. • Land use regression models predict the hourly intra-urban PM variations. • Coefficients of determination for hourly PM predictions ranged 0.66–0.76. • Low-cost PM monitor data need to be carefully evaluated before use. • The combination of low-cost monitors and modeling provides useful PM estimates. Land-use regression (LUR) models provide location and time specific estimates of exposure to air pollution and thereby improve the sensitivity of health effects models. However, they require pollutant concentrations at multiple locations along with land-use variables. Often, monitoring is performed over short durations using mobile monitoring with research-grade instruments. Low-cost PM monitors provide an alternative approach that increases the spatial and temporal resolution of the air quality data. LUR models were developed to predict hourly PM concentrations across a metropolitan area using PM concentrations measured simultaneously at multiple locations with low-cost monitors. Monitors were placed at 23 sites during the 2015/16 heating season. Monitors were externally calibrated using co-located measurements including a reference instrument (GRIMM particle spectrometer). LUR models for each hour of the day and weekdays/weekend days were developed using the deletion/substitution/addition algorithm. Coefficients of determination for hourly PM predictions ranged from 0.66 and 0.76 (average 0.7). The hourly-resolved LUR model results will be used in epidemiological studies to examine if and how quickly, increases in ambient PM concentrations trigger adverse health events by reducing the exposure misclassification that arises from using less time resolved exposure estimates.

54 ENVIRONMENTAL SCIENCES↗

Shedding light on the economic costs of long-duration power outages: A review of resilience assessment methods and strategies

Here this paper provides a literature review of methods and modeling techniques to estimate the cost of power system outages, along with the value of outage mitigation or system resilience. Regulators, policymakers, and infrastructure owners have a growing need to understand the methods for estimating the benefits of resilience improvements of electric infrastructure against natural and man-made disasters. There is a broad literature that estimates the cost of short-duration outages and a small but developing literature on estimating the cost of long-duration outages. This article reviews the models used to estimate the cost of outages and discusses their relative strengths. Additionally, this paper identifies key questions from stakeholders regarding resilience investment and maps them to the relevant models that would help answer them. We include recommendations for future work to include recent advances in regional economic modeling that can estimate region and demographic-specific costs and the distributional consequences of potential resilience projects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermodynamic performance and cost optimization of a novel hybrid thermal-compressed air energy storage system design

Compressed Air Energy Storage (CAES) can potentially allow renewable energy sources to meet electricity demands as reliably as coal-fired power plants. However, conventional CAES systems rely on the combustion of natural gas, require large storage volumes, and operate at high pressures, which possess inherent problems such as high costs, strict geological locations, and the production of greenhouse gas emissions. A novel and patented hybrid thermal-compressed air energy storage (HT-CAES) design is presented which allows a portion of the available energy, from the grid or renewable sources, to operate a compressor and the remainder to be converted and stored in the form of heat, through joule heating in a sensible thermal storage medium. The HT-CAES design incudes a turbocharger unit that provides supplementary mass flow rate alongside the air storage. The hybrid design and the addition of a turbocharger have the beneficial effect of mitigating the shortcomings of conventional CAES systems and its derivatives by eliminating combustion emissions and reducing storage volumes, operating pressures, and costs. Storage efficiency and cost are the two key factors, which upon integration with renewable energies would allow the sources to operate as independent forms of sustainable energy. The potential of the HT-CAES design is illustrated through a thermodynamic optimization study, which outlines key variables that have a major impact on the performance and economics of the storage system. The optimization analysis quantifies the required distribution of energy between thermal and compressed air energy storage, for maximum efficiency, and for minimum cost. This study provides a roundtrip energy and exergy efficiency map of the storage system and illustrates a trade off that exists between its capital cost and performance.

25 ENERGY STORAGE↗

Optimizing fluvial flood mitigation strategies: A multi-objective approach for cost-effective and socially-aware infrastructure feasibility analysis

Effective levee planning must balance capital cost, risk reduction, and community priorities. These objectives are rarely optimized together. This study presents a feasibility phase, simulationin-the-loop framework that couples terrain-based flood modeling with a socially aware multiobjective optimizer. Flood risk is measured as Expected Annual Exposed Population (EAEP), obtained by integrating exposure over Annual Exceedance Probability (AEP) nodes, mirroring the Hydrologic Engineering Center's Flood Damage Reduction Analysis (HEC-FDA) expected-annual formulation but with people rather than dollars. Exposure per scenario is computed by overlaying binary inundation masks with a population surface at the tract level. Distributional fairness is encoded through a Group Benefit Share (GBS) constraint that requires high-SVI tracts to receive at least a baseline share of annualized benefits. Capital cost is represented by a height-dependent unit-cost model suitable for screening. This study addresses the two-objective problem, minimize cost and expected annual exposure subject to the GBS constraint, using Non-Dominated Sorting Genetic Algorithm II (NSGA-II) and leveraging Pareto front for feasibility phase decision making. Implemented with terrain-based flood modeling, GeoFlood, for rapid scenario evaluation, the framework is demonstrated in Southeast Texas. The results reveal clear trade-offs among cost, risk, and social benefits and identify non-dominated levee height configurations that satisfy the benefit-share floor. The contributions are a scalable decision support method that operationalizes expected annual population-based risk, embeds enforceable benefit-sharing guarantees, and uses lightweight simulation to explore large design spaces before higher fidelity design stages.

Flood mitigation↗