At least 1,387 records · Page 77

A Comprehensive Analysis of Energy and Daylighting Impact of Window Shading Systems and Control Strategies on Commercial Buildings in the United States

Commercial buildings consume approximately 1.9 EJ of energy in the United States, 50% of which is for heating, cooling, and lighting applications. It is estimated that windows contribute up to 34% of the energy used for heating and cooling. However, window retrofits are not often undertaken to increase energy efficiency because of the high cost and disruptive nature of window installation. Highly efficient window technologies would also need shading devices for glare prevention and visual comfort. An automated window shading system with an appropriate control strategy is a technology that can reduce energy demand, maintain occupant comfort, and enhance the aesthetics and privacy of the built environment. However, the benefits of the automated shades currently used by the shading industry are not well studied. The topic merits an analysis that will help building owners, designers and engineers, and utilities make informed decisions using knowledge of the impact of this technology on energy consumption, peak demand, daylighting, and occupant comfort. This study uses integrated daylight and whole-building energy simulation to evaluate the performance of various control strategies that the shading industry uses in commercial office buildings. The analysis was performed for three different vintages of medium office buildings at six different locations in United States. The results obtained show the control strategies enabled cooling energy savings of up to 40% using exterior shading, and lighting energy savings of up to 25%. The control strategies described can help building engineers and researchers explore different control methods used to control shading in actual buildings but rarely discussed in the literature. This information will give researchers the opportunity to investigate potential improvements in current technologies and their performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Developing and improving a scanning system for dosimetric applications

Radiotherapy is nowadays one of the most used techniques for the treatment of different pathologies, particularly cancer diseases. The accuracy regarding the application of these treatments, which are planned according to patient information, depends mainly on the dosimetric measurements of absorbed dose within irradiated tissues. The present work is devoted to the study, design and construction of an original device capable of performing visible light transmission measurements in order to analyze Fricke gel dosimeters. Furthermore, a suitable bi-dimensional positioning system along with a dedicated control system and image processing software has been adapted to the dosimetric device in order to perform 2D dose mapping. The obtained results confirm the feasibility of the proposed method, therefore suggesting its potentiality for clinical applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A near infra-red video system as a protective diagnostic for electron cyclotron resonance heating operation in the Wendelstein 7-X stellarator

The Wendelstein 7-X stellarator is a large nuclear fusion device based at Max-Planck-Institut für Plasmaphysik in Greifswald in Germany. The main plasma heating system for steady state operation in W7-X is electron cyclotron resonance heating (ECRH). During operation, part of plama facing components will be directly heated by the non-absorbed power of 1 MW rf beams of ECRH. In order to avoid damages of such components made of graphite tiles during the first operational phase, a near infra-red video system has been developed as a protective diagnostic for safe and secure ECRH operation. Both the mechanical design housing the camera and the optical system are very flexible and respect the requirements of steady state operation. The full system including data acquisition and control system has been successfully tested in the vacuum vessel, including on-line visualization and data storage of the four cameras equipping the ECRH equatorial launchers of W7-X.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

National-Level Energy Impacts of Cooperative Adaptive Cruise Control (CACC) Systems

This poster highlights a study of the potential national-level energy impact of connected and automated vehicles and technologies (e.g., cooperative adaptive cruise control (CACC), eco-signals, automated mobility districts, etc.) and how varying levels of CACC adoption affect on-road fuel economy for different vehicle powertrains as well as potential changes in vehicle-miles-traveled distributions.

33 ADVANCED PROPULSION SYSTEMS↗

Automated Programmable Logic Controller Memory Forensics Using RGB Image Analysis and Deep Learning

The introduction of Industry 4.0 and Internet-based technologies has enhanced industrial control system operations but have inadvertently increased their vulnerabilities to cyber attacks. When an industrial control system is compromised, security analysts need to identify the root cause quickly to start the recovery process and develop mitigation strategies. Memory forensics is critical in the incident analysis process to ascertain what occurred. Approaches for analyzing the persistent memory in industrial control devices are limited and almost nonexistent for volatile memory. This chapter proposes an automated methodology for programmable logic controller memory dump analysis using computer vision and deep learning techniques. The methodology converts the sequences of bytes in a programmable logic controller memory dump to red-green-blue pixels and employs a deep learning model that learns the underlying patterns and features of pre-labeled forensic artifacts in images and segments them into distinct regions. The trained model is employed to automatically segment new memory images and identify forensic artifacts. Evaluation of the methodology on a Schneider Electric Modicon M221 programmable logic controller under code injection and code modification attacks demonstrates its ability to detect attack artifacts in memory dumps.

Asmar Awad, Rima [ORNL] (ORCID:0000000233407742)↗

Specification of EBR-II Laser Profilometry Data

All laser profilometry data stored in FIPD were originally measured using the element laser profilometer system in HFEF/N. The irradiated fuel elements or pins were scanned by a laser beam to measure the outer diameter with position mapping of the spacer wire. The normal operation and data collection were performed automatically with HFEF/N Data Acquisition and Process Control System (DAPCS). With the digital control system, measured laser profilometry data were recorded in digital form on magnetic tapes, different from the analog contact profilometry data recorded by strip-chart record sheets. Two documents contained most of the important details about laser profilometry measurements. The first one is the operational manual of the laser profilometer (title: Element laser profilometer (ELP) operation and maintenance manual, HFEF/N OMM 4329, DOC. NO. W0171-0149-ES-01). This manual provides: (1) description of laser profilometer including the functions of each component (transceiver, retroreflector, clamping guide, shielding enclosure, electronic controller, etc.); (2) step-by-step guidance for calibrations, operations and measurements; and (3) maintenance procedures and other details of the element laser profilometer. Since first issued on 12/1/1986, several revisions/changes of the manual were developed to update the measurement accuracies and other factors for the laser profilometer system. The second document is a publicly accessible conference article titled “the element laser profilometer system in HFEF/N.” This article summarizes important functions and parameters of the laser profilometer. The range of measurements and the uncertainties reported in the article were consistent with the values reported in the operational manual.

42 ENGINEERING↗

National Ignition Facility and Managing Location, Component, and State

The National Ignition Facility (NIF) at the Lawrence Livermore National Laboratory is a stadium-sized facility that contains a 192-beam, 1.8-Megajoule, 500-Terawatt, ultraviolet laser system coupled with a 10-meter diameter target chamber. There are over 6,200 Line Replaceable Units (LRUs) comprised of more than 104,000 serialized parts that make up the NIF. Each LRU is a modular unit typically composed of a mechanical housing, laser optics (glass, lenses, or mirrors), and utilities. To date, there are more than 120,000 data sets created to characterize the attributes of these parts. Greater than 51,000 Work Permits have been issued to install, maintain, and troubleshoot the components. One integrated system is used to manage these data, and more. The Location Component and State (LoCoS) system is a web application built using Java Enterprise Edition technologies and is accessed by over 1,200 users. It is either directly or indirectly involved with each aspect of NIF work activity, and interfaces with ten external systems including the Integrated Computer Control System (ICCS) and the Laser Performance Operations Model (LPOM). Besides providing business functionality, LoCoS also acts as the NIF enterprise service bus. In this role, numerous integration approaches had to be adopted including: file exchange, database sharing, queuing, and web services in order to accommodate various business, technical, and security requirements. Architecture and implementation decisions are discussed.

42 ENGINEERING↗

Learning-based Anticipatory Control of Microreactors

Learning-based anticipatory control advances the level of autonomy of microreactor control systems, a key consideration for the unattended operation of fission batteries. In this work, an anticipatory control system is shown to provide accurate load-following for a microreactor by utilizing a model predictive control framework.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Risk Level Based Management System: a control banding model for occupational health and safety risk management in a highly regulated environment

The Risk Level Based Management System (RLBMS) is an occupational risk management (ORM) model that focuses occupational safety, hygeiene, and health (OSHH) resources on the highest risk procedures at work. This article demonstrates the model's simplicity through an implementation within a heavily regulated research institution. The model utilizes control banding strategies with a stratification of four risk levels (RLs) for many commonly performed maintenance and support activities, characterizing risk consistently for comparable tasks. RLBMS creates an auditable tracking of activities, maximizes OSHH professional field time, and standardizes documentation and control commensurate to a given task's RL. Validation of RLs and their exposure control effectiveness is collected in a traditional quantitative collection regime for regulatory auditing. However, qualitative risk assessment methods are also used within this validation process. Participatory approaches are used throughout the RLBMS process. Workers are involved in all phases of building, maintaining, and improving this model. This work participation also improves the implementation of established controls.

99 GENERAL AND MISCELLANEOUS↗

Analysis of Off-Board Powered Thermal Preconditioning in Electric Drive Vehicles: Preprint

Following a hot or cold thermal soak, vehicle climate control systems (air conditioning or heat) are required to quickly attain a cabin temperature comfortable to the vehicle occupants. In a plug-in hybrid electric or electric vehicle (PEV) equipped with electric climate control systems, the traction battery is the sole on-board power source. Depleting the battery for immediate climate controlresults in reduced charge-depleting (CD) range and additional battery wear. PEV cabin and battery thermal preconditioning using off-board power supplied by the grid or a building can mitigate the impacts of climate control. This analysis shows that climate control loads can reduce CD range up to 35%. However, cabin thermal preconditioning can increase CD range up to 19% when compared to nothermal preconditioning. In addition, this analysis shows that while battery capacity loss over time is driven by ambient temperature rather than climate control loads, concurrent battery thermal preconditioning can reduce capacity loss up to 7% by reducing pack temperature in a high ambient temperature scenario.

25 ENERGY STORAGE↗

Mathematical model of unmanned aerial vehicle used for endurance autonomous monitoring

The paper purpose is to present some aspects regarding the control system of unmanned aerial vehicle - UAV, used to local observations, surveillance and monitoring interest area. The calculus methodology allows a numerical simulation of UAV evolution in bad atmospheric conditions by using nonlinear model, as well as a linear one for obtaining guidance command. The UAV model which will be presented has six DOF (degrees of freedom), and autonomous control system. This theoretical development allows us to build stability matrix, command matrix and control matrix and finally to analyse the stability of autonomous UAV flight. A robust guidance system, based on uncoupled state will be evaluated for different fly conditions and the results will be presented. The flight parameters and guidance will be analysed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cyber Informed Engineering Cie Analysis Tool

Main Benefits: • Collaborate on assessment via the web and access and share assessments on your mobile device. • Helps you maximize your cybersecurity investment and resources • Saves you significant time and money by eliminating the requirement to research each government and industry standard in order to understand your cybersecurity posture • Contains easy to follow, step by step instructions to guide you through the process of identifying the cybersecurity posture of your organization • Provides a place to begin with cybersecurity improvement and a way to prioritize your tasks and budgets. • Covers all major cyber relevant topic areas for a comprehensive assessment of your organization’s cybersecurity posture. • Dives deep into the details of each topic area. • Contributes to the organization's risk management and decision-making process • Highlights vulnerabilities and gaps in your organization's IT and control systems. • Raises awareness and facilitates discussion on cybersecurity within your organization • Educates the controls system community on cyber security.

Hansen, Barry [Idaho National Laboratory (INL), Id↗

STEPPER MOTOR CONTROL, PLC VS VME

Traditionally, EPICS-based accelerator control systems have used VME-based motion control modules to interface with stepper motors. For systems that include some Programmable Logic Controllers (PLC), there is an option for using PLC-based stepper motor interface modules. As with all control system choices, there are trade-offs. This paper will delineate some of the pros and cons of both methods of interfacing with stepper motors.

Strong, William Herb↗

Linac Energy Management for LCLS

Linac Energy Management (LEM) is a control system program that scales magnet field set-point settings following a change in beam energy. LEM is necessary because changes in the number, phase, and amplitude of the active klystrons change the beam's rigidity, and therefore, to maintain constant optics, one has to change focusing gradients and bend fields accordingly. This paper describes the basic process, the control system application programs we developed for LEM, and some of the implementation lessons learned at the Linac Coherent Light Source (LCLS).

43 PARTICLE ACCELERATORS↗

Full Energy Injection and Top-up Operation at UVSOR-II

Top-up operation was successfully demonstrated at UVSOR-II, which will remove the short beam-lifetime problem caused by strong Touschek effect due to the small emittance, 27 nm-rad, and the low electron energy, 750 MeV. In these years, we have improved the accelerators, step by step, towards top-up operation. The radiation shielding wall was reconstructed. The energy of the booster synchrotron and the beam transport line were successfully upgraded from 600 MeV to 750 MeV, by replacing the magnet power supplies in 2006. Soon after, we succeeded in injecting the electron beam at the full energy. We improved the radiation safety system and constructed a injection control system. In autumn, 2008, we succeeded in operating the ring for 12 hours as keeping the beam current quasi-constant at 300 mA. Currently, we operated the ring in the top-up mode for 12 hours on every Thursday night, to check the effects on the users' experiments. In 2009, we have succeeded in the top-up operation in single bunch mode. Free electron laser oscillation with the top-up mode was also successfully demonstrated.

43 PARTICLE ACCELERATORS↗

Wire Scanner Beam Profile Measurements: LANSCE Facility Beam Development

The Los Alamos Neutron Science Center (LANSCE) is replacing Wire Scanner (WS) beam profile measurement systems. Three beam development tests have taken place to test the new wire scanners under beam conditions. These beam development tests have integrated the WS actuator, cable plant, electronics processors and associated software and have used H{sup -} beams of different beam energy and current conditions. In addition, the WS measurement-system beam tests verified actuator control systems for minimum profile bin repeatability and speed, checked for actuator backlash and positional stability, tested the replacement of simple broadband potentiometers with narrow band resolvers, and tested resolver use with National Instruments Compact Reconfigurable Input and Output (cRIO) Virtual Instrumentation. These beam tests also have verified how trans-impedance amplifiers react with various types of beam line background noise and how noise currents were not generated. This paper will describe these beam development tests and show some resulting data.

43 PARTICLE ACCELERATORS↗

Energy Efficiency and Infrastructure Upgrades on Nuclear Clean-up Sites: The Hanford Experience - 18641

The Hanford site, located in southeastern Washington, produced much of our nation's weapons-grade plutonium for the Defense nuclear weapons program. This production lasted the better part of four decades with production ending in 1987. Since 1987, the focus of the Hanford site has turned to clean-up activities. Mission Support Alliance (MSA) is the integrator of the multi-contractor effort to clean up the Hanford site. MSA collaborates with the U.S. Department of Energy (DOE) and all Hanford site contractors in finding and implementing new, cost-saving, safe and practical solutions to cleanup challenges with a continual focus on innovative processes and technologies that reduce costs, energy use and bring safety improvements to the site. Support Services include environmental integration and land management; fleet and road maintenance; water/electric and utilities; cyber security and information management as well as the preservation of the site's cultural artifacts. This paper describes the process, challenges, and focus on infrastructure upgrade and energy efficiency projects in the context of a multi-contractor nuclear clean-up site. Project development and new technology deployment at Hanford has long been plagued with economic challenges. For example, despite extensive auditing, analysis, and project development, most of the energy-related projects on the Hanford site have gone unfunded due to the low cost of electricity, the relatively high cost of labor, and costs associated with detailed safety and cultural reviews. - The Hanford site is a direct-service customer of the Bonneville Power Administration (BPA) and has a marginal electricity rate of $0.033/kWh. - Labor costs on the Hanford site track high because of the requirements associated with the safety and security necessary to operate a legacy nuclear weapons complex. - In partnership with three federally recognized and other affected Native American tribes (Yakama Nation, Confederated Tribes of the Umatilla Indian Reservation, the Nez Perce Tribe, and Wanapum People), most activities on the Hanford site are afforded in-depth cultural reviews. To work within these constraints, the MSA Energy Management team has embarked on a three-pronged approach to energy project development: Program Visibility: The MSA Energy Management team has promoted both project opportunities and requirements across the Hanford site. This information comes in the form of site-wide newsletters, group meetings, e-mails, success stories, and recognition of staff. Single-point Analysis: To by-pass the inevitable duplications of effort, learning curve issues, and to improve project consistency/delivery, the MSA Energy Management team serves as the single resource to the site for energy project analysis. This resource includes initial assessment, engineering analysis, efficiency calculation and project recommendations. Contractor/utility Interface: In addition to the infrastructure under its own purview, MSA provides all support services for the contractor/utility interface. These activities include formulation and submission of incentive-based efficiency projects, project tracking, and incentive awards. All incentive awards are forwarded to the relevant contractor and then highlighted in the visibility campaign. Successful energy efficiency projects at Hanford have included high efficiency heating, ventilation, air conditioning (HVAC) systems, interior and exterior lighting/lighting control systems, pump and motor systems, and the right-sizing of transformers and area-wide electrical distribution systems. Prior to the initiation of this program and structure (roughly 3 years ago) the average annual energy efficiency incentive applied for and received was under $10,000, with an annual energy savings of approximately 36,000 kilowatt hours (kWh). In fiscal year 2017, the annual incentive received was over $419,000, with identified energy savings of over 1.3 million kWh. Details and case studies of the major project accomplishments are included. The success of this program can be traced to an understanding of the constraints, the development of a program to address these constraints, and good communication/coordination across DOE and the multiple contractors serving the Hanford site. (authors)