Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Complex Loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

A Distributed Energy Management Approach for Residential Demand Response

The implementation of large-scale optimization and control of residential appliances to support demand response (DR) programs comes with the challenges of coordinated communication, privacy, and consideration of customer preferences. Solving this complexity is best suited through a distributed optimization and control approach at the residential level by leveraging the availability and intelligence of a home energy management systems (HEMS). In this paper, a hierarchical control scheme to coordinate large-scale residential demand response through coordination of HEMs is proposed. This scheme is based on the exchange of a reward price and aggregated load information between utility system and HEMS. Numerical results on a one hundred-house model demonstrate the computational efficiency of the proposed approach.

Kou, Xiao↗

Biochar-compost-based controlled-release nitrogen fertilizer intended for an active microbial community

Nitrogen (N) fertilizers in agriculture suffer losses by volatilization of N to the air, surface runoff and leaching into the soil, resulting in low N use efficiency (NUE) (< 50%) and raising severe environmental pollutions. Controlled- release nitrogen fertilizers (CRNFs) can control the release of N nutrients to NUE in crop production. Different methods were used to develop new CRNFs. However, different CRNF technologies are still underdeveloped due to inadequate controlling on N releasing time and/or unsustainable diffusion. The study on the influences of CRNF processing parameters on microbial conditions are lacking when the CRNFs composed of various bio-ingredients such as biochar, composts, and biowaste. The complexity of processing methods, material biodegradability, and other physical properties make current CRNFs of questionable value in agricultural production. This research aims to develop a novel biochar-compost-based controlled-release urea fertilizer (BCRUF) to preserve microbial properties carried by the compost. The BCRUF was synthesized by pelletizing the 50:50 (dry, wt/wt) mixture of biochar and compost. BCRUF was loaded with urea and then spray-coated with polylactic acid (PLA). The releasing time of two types of BCRUFs, coated and uncoated with PLA, for 80% of N release in water was up to 6 h at three different temperatures (4, 23, and 40 °C), compared to conventional urea fertilizer and commercial environmentally smart N (ESN) fertilizer. The releasing time of coated BCRUF for 80% N release in soil was up to 192 h (8 days). Fourier-transform infrared spectroscopy (FTIR) analysis revealed that no new functional groups were found in the release solution, indicating no new chemical hazards generated. The differential scanning calorimetry (DSC) tests also verified that its thermal stability could be up to 160 °C. The microbe populations in the BCRUF pellets were reduced after the pelleting and drying processes in BCRUF fabrication, but a few bacteria can endure in the air-drying process. BCRUF pellets soaked in water for 4 days retained some bacteria. The BCRUF showed very promising characteristics to improve NUE and sustainability in agricultural production.

58 GEOSCIENCES↗

HP-FLEX: Field demonstration of the semantics-driven configuration of a Model Predictive Control system to make heat pumps flexible

Model Predictive Control (MPC) has demonstrated significant potential for optimizing building operations and enabling demand flexibility. However, the widespread adoption of MPC is hindered by complex manual configuration and commissioning processes that must be conducted by control experts working alongside building operators. These challenges drive up costs and reduce scalability, particularly when technical human resources and building automation systems are limited, such as in small and medium commercial buildings (SMCBs). This paper demonstrates how semantic standards, specifically ASHRAE 223P, can accelerate the adoption of MPC applications for load flexibility in SMCBs. The authors present a replicable control framework, titled “HP-FLEX” that leverages a building’s semantic model to bootstrap the required data configuration for an MPC controller developed for optimizing heat pump systems as flexible grid resources. The semantic model helps streamline the deployment workflow, particularly for site setup, data/control commissioning, and model setup. This integration enhances portability, transferability, and scalability of the HP-FLEX MPC, which has been developed to support MPC-based supervisory HVAC controllers in SMCBs. Additionally, the paper details the required building and thermostat metadata information to enable the HP-FLEX MPC based on field demonstrations. The new workflow was tested in a small commercial building located in California, U.S., and demonstrated a load shifting performance of 9% based on a dynamic pricing signal that varies by the hour. This work provides a practical pathway for transitioning sophisticated building applications from custom to standardized semantic representations, supporting the broader adoption of advanced control strategies like MPC. The framework also establishes a foundation for evolving metadata requirements as applications mature while maintaining compatibility with industry standards.

Paul, Lazlo↗

Investigation of the Effect of In-Plane Fiber Waviness in Composite Materials through Multiple Scales of Testing and Finite Element Modeling

Defects in materials can reduce strengths and lifetimes of manufactured parts. The number of possible defects increases with the complexity inherent in composite materials. The wind industry uses composite wind turbine blades in which the manufacturing process induces a number of defects. In order for the wind industry to continue sustainable expansion, the effects of defects must be better understood. In-plane (IP) fiber waviness is the focus of this work. The three main parts of this work include testing on the coupon level, modeling on the coupon level, and testing of beams in four-point bending (with and without defects). The coupon level testing includes partial IP waves, similar to those in manufactured parts, rather than full width IP waves. This allows investigation into complex interactions and varying failure mechanisms caused by the fiber misalignment gradient. Partial waves are also modeled to both validate testing as well as to increase robustness of a previously developed progressive damage modeling method. Lastly, a sandwich beam test specimen for testing in 4-point bending is developed to investigate the effects of fiber waviness in both tension and compression when loaded in flexure.

36 MATERIALS SCIENCE↗

HP-FLEX: Field Demonstration of the Semantics-Driven Configuration of a Model Predictive Control System to Make Heat Pumps Flexible

Model Predictive Control (MPC) has demonstrated significant potential for optimizing building operations and enabling demand flexibility. However, the widespread adoption of MPC is hindered by complex manual configuration and commissioning processes that must be conducted by control experts working alongside building operators. These challenges drive up costs and reduce scalability, particularly when technical human resources and building automation systems are limited, such as in small and medium commercial buildings (SMCBs). This paper demonstrates how semantic standards, specifically ASHRAE 223P, can accelerate the adoption of MPC applications for load flexibility in SMCBs. The authors present a replicable control framework, titled “HP-FLEX” that leverages a building’s semantic model to bootstrap the required data configuration for an MPC controller developed for optimizing heat pump systems as flexible grid resources. The semantic model helps streamline the deployment workflow, particularly for site setup, data/control commissioning, and model setup. This integration enhances portability, transferability, and scalability of the HP-FLEX MPC, which has been developed to support MPC-based supervisory HVAC controllers in SMCBs. Additionally, the paper details the required building and thermostat metadata information to enable the HP-FLEX MPC based on field demonstrations. The new workflow was tested in a small commercial building located in California, U.S., and demonstrated a load shifting performance of 9% based on a dynamic pricing signal that varies by the hour. This work provides a practical pathway for transitioning sophisticated building applications from custom to standardized semantic representations, supporting the broader adoption of advanced control strategies like MPC. The framework also establishes a foundation for evolving metadata requirements as applications mature while maintaining compatibility with industry standards.

Paul, Lazlo↗

Radiological Shielding Design for the Neutron Backscattering Spectrometer EMU

In this paper we present modelling and design of compact radiation shielding required for operation of the EMU instrument, located at Australia's OPAL nuclear reactor. The acceptance criteria for the shielding design were (i) safety - dose rate ≤ 3 μSv/h at external surfaces of the instrument's experimental area, (ii) floor load limit < 20 tons/m{sup 2}, (iii) low cost and (iv) for maintenance purposes 'easy access' to components of the instruments. The EMU instrument is a cold neutron backscattering spectrometer designed to measure inelastic neutron scattering. Its distinctive feature is that it has a tight elastic energy transfer resolution, of about 1 μeV. The instrument provides unique opportunities to study diffusion in complex materials, e.g. water molecules in confinement, polymers or biological molecules, particularly in the Asia-Oceania region. EMU is the first instrument located on the CG3 neutron beam line of the OPAL Neutron Guide Hall (NGH). A pre-existing evacuated neutron guide of dimensions 200 mm (height) x 50 mm (width) feeds into the shared EMU/KOOKABURRA pre-monochromator bunker shielding assembly, and its bottom cross section will be intercepted ∼200 mm further in air by the highly orientated pyrolytic graphite (HOPG) EMU pre-monochromator (take-off angles from 125.4 deg. to 148 deg.). The bunker shielding assembly for EMU also contains a beryllium filter and Focusing Guide Section D (FGD, 170 mm (height) x 50 mm (width)). To accommodate the range of take-off angles Pb cylindrical shielding blocks of radius 140 mm and 500 mm height have been designed. These blocks will be located at the section of the bunker where the neutron beam will exit towards the experimental area and they will reside on top of a hollow steel base (sides 10 mm thick), on which they move by sliding and are integrated with the tertiary shutter. The experimental area is enclosed by a concrete wall of 2.5 m height and 300 mm thickness, shared with the KOOKABURRA instrument, Gyprock Plasterboard panels with viewing windows, a wall from the Out-of-Pile Bunker and the CG3 shielding. The neutron beam enters the experimental area via the tertiary shutter, into the Focusing Guide Section C (FGC), which has an entrance guide cross-section of 158 mm (height) x 79 mm (width) and exit guide cross-section of 149 mm (height) x 85 mm (width) and is of length 816 mm. The vacuum chamber of FGC will be connected to the vacuum chamber of the Background Chopper (BC, disc of outer radius 350 mm). Focusing Guide Section B (FGB) is aligned with FGC and its vacuum shared with the BC vacuum. The FGB has an exit guide cross section of 50 mm (height) x 49 mm (width) and is of length 4046 mm, which will focus the neutron beam vertically and horizontally towards the Al window entrance (0.82 mm thickness, labelled N16) of the Scattering Tank assembly (constructed from 20 mm - 40 mm thickness stainless steel and will be under vacuum < 1 x 10{sup -3} mbar). Inside the Scattering Tank there is another section of Focusing Guide (FGA), with an exit guide cross-section of 30 mm (height) 30 mm (width) and of length 417 mm. The neutron beam exiting the FGA will be reflected by the HOPG crystal pieces of the Graphite Chopper (GC) towards the Backscattering Monochromator (BM). The reflected neutron beam will first pass through the other Al window (0.82 mm thickness, labelled N17) of the Scattering Tank and then enter into a flight tube (steel of 10 mm thickness). The BM is formed in an 1800 mm spherical radius array of Si crystal elements (0.87 mm thickness) and is oscillated by the linear motor Doppler Drive. The neutron beam will be reflected back at 180 deg. from, and focussed by the BM to reenter the Scattering Tank through the N17 Al window. It will then pass through the GC (HOPG crystals are rotated out of the way) and will reach the scattering sample of interest to the instrument end user. Also, inside the Scattering Tank there will be {sup 3}He linear position-sensitive detectors, and Analyser Arrays formed in an 1800 mm radius spherical arrays of Si crystal elements (0.87 mm thickness) glued on aluminium support frames (10 mm thickness) and span ∼160 deg. arc.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Preparation of polymer/LDH nanocomposite by UV-initiated photopolymerization of acrylate through photoinitiator-modified LDH precursor

Graphical abstract: This is the HR-TEM micrograph of UV cured nanocomposite at 5 wt% LDH-2959 loading for a-5 sample. The dark lines are the intersections of LDH platelets. It can be seen that samples a-5 dispersed in the polymer matrix and lost the ordered stacking-structure and show the completely exfoliation after UV curing. This can be explained by the fact that the sample a-5 only containing LDH-2959 exhibited a relative lower photopolymerization rate, which was propitious to further expand the LDH intergallery to form the exfoliated structure. Research highlights: {yields} The UV cured polymer/LDH nanocomposites were prepared through the photopolymerization initiated by the photoinitiator-modified LDH precursor, LDH-2959. {yields} The exfoliated UV cured nanocomposites were achieved in the presence of LDH-2959 only. However, the UV cured nanocomposites prepared using both LDH-2959 and Irgacure 2959 showed the intercalated structure. {yields} Compared with the pure polymer, the exfoliated polymer/LDH nanocomposite showed remarkable enhanced thermal stability and mechanical properties because of their well dispersion in the polymer matrix. -- Abstract: The exfoliated polymer/layered double hydroxide (LDH) nanocomposite by UV-initiated photopolymerization of acrylate systems through an Irgacure 2959-modified LDH precursor (LDH-2959) as a photoinitiator complex was prepared. The LDH-2959 was obtained by the esterification of 2-hydroxy-4'-(2-hydroxyethoxy)-2-methylpropiophenone (Irgacure 2959) with thioglycolic acid, following by the addition reaction with 3-(2,3-epoxypropoxy)propyltrimethoxysilane (KH-560), finally intercalation into the sodium dodecyl sulfate-modified LDH. For comparison, the intercalated polymer/LDH nanocomposite was obtained with additive Irgacure 2959 addition. From the X-ray diffraction (XRD) measurements and HR-TEM observations, the LDH lost the ordered stacking-structure and well dispersed in the polymer matrix at 5 wt% LDH-2959 loading. The glass transition temperature of UV-cured exfoliated nanocomposites increased to 64 {sup o}C from 55 {sup o}C of pure polymer without LDH addition. The tensile strength was improved from 10.1 MPa to 25.2 MPa, as well the Persoz hardness enhanced greatly, while the elongation at break remained an acceptable level.

36 MATERIALS SCIENCE↗

Super Resolving Unrolled Neural Networks for Remote Sensing

In remote sensing systems, the capabilities of the system are constrained by the complex interactions between size, weight, and power (SWAP) of potential designs. In electro-optical (EO) systems, examples of these critical parameters include the system’s sensitivity and resolution. Those parameters can be increased by ever larger optical apertures and focal planes but at the cost of more SWAP. Multi-image super resolution (MISR) techniques allow resolution to be enhanced via computation rather than more sophisticated optical hardware. These algorithms combine multiple images together into a single, higher resolution image, trading temporal resolution and computation for spatial resolution. Fielded MISR techniques, such as Drizzle, can require several hundred images to create a single super resolved image, implying reduced temporal resolution, increased data acquisition load, and limiting mission applications. Iterative techniques, such as model-based image reconstruction and compressive sensing, have been shown to create super resolved images using fewer images than Drizzle. They do this by posing an optimization problem that balances accuracy between a highly accurate physical model and an image model. In the case of super resolution, the physical model is defined by the relation between low resolution input images and the desired high resolution output image. The image model encodes some assumptions about the super resolved image. These assumptions are meant to suppress reconstruction artifacts that arise due to deterministic physical model error, stochastic measurement noise, and potential undersampling. In practice, the performance of iterative methods are limited by imaging models compatible with optimization. Deep learning-based methods can effectively learn image models of arbitrary complexity, but lack the theoretical explainability and robustness of iterative techniques. Consensus equilibrium (CE) generalizes the iterative techniques beyond optimization, enabling blackbox algorithms such as traditional and neural image denoisers to be used as the image model. CE-based approaches retain much of the explainability and robustness of iterative techniques while allowing the expressiveness of machine learning image models to be used. Additionally, by unrolling iterations of CE with an embedded image denoiser, the image denoiser can be further trained and specialized to the specific application with potentially higher quality reconstructions. Under this project, we demonstrated the feasibility of training an unrolled neural network based upon CE. While we didn’t train one, we showed that the CE process is differentiable and its gradient can be tractably computed. We also explored the usage of a variants of CE akin to generative neural works. Most importantly, we applied the CE framework to a number of problems including non-blind deconvolution, upsampling, single-image super resolution, MISR, event-based sensing, and saturated deconvolution. Our MISR prototype creates high quality reconstructions with an order of magnitude fewer images than previous approaches and, critically, produces these reconstructions fast enough for practical usage.

47 OTHER INSTRUMENTATION↗

Using Public Participation to Improve MELs Energy Data Collection

Miscellaneous Electric Loads (MELs) have proliferated in the last decade, and comprise an increasing share of building energy consumption. Because of the diversity of MELs and our lack of understanding about how people use them, large-scale data collection is needed to inform meaningful energy reduction strategies. Traditional methods of data collection, however, usually incur high labor and metering equipment expenses. As an alternative, this paper investigates the feasibility of crowdsourcing data collection to satisfy at least part of the data collection needs with acceptable accuracy. This study assessed the reliability and accuracy of crowdsourced data, by recruiting over 20 volunteers (from the 2012 Lawrence Berkeley Lab, Open House event) to test our crowdsourcing protocol. The protocol asked volunteers to perform the following tasks for three test products with increasing complexity - record power meter and product characteristics, identify all power settings available, and report the measured power. Based on our collected data and analysis, we concluded that volunteers performed reasonably well for devices with functionalities with which they are familiar, and might not produce highly accurate field measurements for complex devices. Accuracy will likely improve when participants are measuring the power used by devices in their home which they know how to operate, by providing more specific instructions including instructional videos. When integrated with existing programs such as the Home Energy Saver tool, crowdsourcing data collection from individual homeowners has the potential to generate a substantial amount of information about MELs energy use in homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Adaptive Fast Multipole Boundary Element Method for Poisson-Boltzmann Electrostatics

The numerical solution of the Poisson Boltzmann (PB) equation is a useful but a computationally demanding tool for studying electrostatic solvation effects in chemical and biomolecular systems. Recently, we have described a boundary integral equation-based PB solver accelerated by a new version of the fast multipole method (FMM). The overall algorithm shows an order N complexity in both the computational cost and memory usage. Here, we present an updated version of the solver by using an adaptive FMM for accelerating the convolution type matrix-vector multiplications. The adaptive algorithm, when compared to our previous nonadaptive one, not only significantly improves the performance of the overall memory usage but also remarkably speeds the calculation because of an improved load balancing between the local- and far-field calculations. We have also implemented a node-patch discretization scheme that leads to a reduction of unknowns by a factor of 2 relative to the constant element method without sacrificing accuracy. As a result of these improvements, the new solver makes the PB calculation truly feasible for large-scale biomolecular systems such as a 30S ribosome molecule even on a typical 2008 desktop computer.

97 MATHEMATICS AND COMPUTING↗

Elastic wave suppression through additively manufactured petal lattice metamaterials

Lattice-core sandwich structure metamaterials are lightweight alternatives to monolithic materials that can present better mechanical, thermal, and energy dampening performance. Manufacturing lattice metamaterials to follow curved surfaces can pose a challenge, as the lattices rely on their geometric orientation to the substrate for their mechanical properties. This work rationally designed a lattice structure where the surface is broken up into “petals” connected to the underlying lattice, which localizes the petals’ impact response. This design opens a pathway for implementation of lattice-core sandwich structures onto complex surface geometries. These petal structures were evaluated for their energy absorption efficiency experimentally by utilizing pressure waves generated with nanosecond lasers and computationally via finite element modeling. The lattice structures exhibited a two-orders-of-magnitude decrease in transmitted pressure compared to their constituent steel at equivalent mass. Furthermore, localizing energy absorption into petal structures provided a 44% reduction in peak load compared to a continuous “single-petal” design.

Sarracino, Alex↗

Improving large-scale storage system performance via topology-aware and balanced data placement

With the advent of big data, the I/O subsystems of large-scale compute clusters are becoming a center of focus. More applications are putting greater demands on end-to-end I/O performance. These subsystems are often complex in design. They comprise of multiple hardware and software layers to cope with the increasing capacity, capability, and scalability requirements of data intensive applications. However, the sharing nature of storage resources and the intrinsic interactions across these layers make it a great challenge to realize end-to-end performance gains. This paper proposes a topology-aware strategy to balance the load across resources, to improve the per-application I/O performance. We demonstrate the effectiveness of our algorithm on an extreme-scale compute cluster, Titan, at the Oak Ridge Leadership Computing Facility (OLCF). Our experiments with both synthetic benchmarks and a real-world application show that, even under congestion, our proposed algorithm can improve large-scale application I/O performance significantly, resulting in both a reduction in application run time as well as a higher resolution of simulation run.

Wang, Feiyi↗

A Technical and Economic Assessment of LWR Flexible Operation for Generation and Demand Balancing to Optimize Plant Revenue

With increased penetration of subsidized variable renewable energy (VRE) resources and competition from low natural gas prices, existing light water reactor (LWR) nuclear power plants (NPPs) are struggling to remain economically competitive. This work examines the potential economic competitiveness of various thermal energy storage (TES) technologies when coupled directly or indirectly with a NPP. To highlight their relative economic competitiveness, we contrast several energy storage solutions in stochastic dispatch optimization. We leverage data from recent work analyzing a range of TES technologies with varying capital costs, performance, and technology readiness level (TRL) to establish our case. We explore inserting these technologies into an electricity market with existing nuclear generation and large projected variable renewable energy (VRE) penetration. Although these technologies' projected capital costs may make them unlikely candidates in their current state, this analysis demonstrates a high-fidelity techno-economic analysis of energy storage. Furthermore, as the projected cost of energy storage technologies evolves, this analysis sets a precedent for similar future investigations. One region with projected trends that may be unfavorable for existing nuclear capacity is the New York Independent System Operator (NYISO) market. New York state’s baseload generation has been historically provided by fossil-fired and nuclear assets. However, amid economic pressures from subsidized VREs and low natural gas prices, the state has recently deactivated Indian Point nuclear power plant units 2 and 3. Furthermore, the state plans to meet its zero-emission generation target by 2040 by replacing fossil-fired capacity with significant investments in VRE resources like wind and solar photovoltaic (PV) and battery storage. Increased intermittent resource penetration lowers the baseload power requirement, adding further economic pressure to the state’s three remaining NPPs still in operation. With three NPPs still in operation in New York, this work analyzes potential economic benefits to NPPs on the New York grid when directly or indirectly coupled with various TES technologies. This work requires two modeling steps to analyze the potential economic benefits of various system configurations of the TES directly or indirectly coupled with nuclear. First, this analysis leverages capacity expansion modeling by experts at the Electric Power Research Institute (EPRI). Using their deterministic capacity expansion model, U.S. Regional Economy, Greenhouse Gas, and Energy (US-REGEN), EPRI analysts evaluated the capacity and generation evolution of the New York state energy market under four projection scenarios. These four projection scenarios were developed to represent the potential evolution of the capacity and generation in NYISO from 2015 to 2050 under various economic, technology, and policy constraints. The results from these capacity expansion models are then used as boundary conditions in the second modeling step. The second modeling step uses the Holistic Energy Resource Optimization Network (HERON) for a set of stochastic techno-economic analyses (STEAs) to investigate the potential increase in the economic viability of various configurations of the TES. With no current capacity expansion capabilities, HERON takes the data generated from US-REGEN for 2050 to generate synthetic load, solar, and wind data. Then HERON economically optimizes the capacity and dispatch of the various TES configurations. The potential economic benefit is the differential net present value (NPV) of the TES configurations from the no-TES baseline. As a stochastic techno-economic analysis package, HERON introduces uncertainty into the economic metrics, while US-REGEN trades resolution for reduced computational complexity. Using HERON also allows the modeling of direct thermal coupling, a feature not common in capacity and dispatch models. As expected, with high capital costs, the costs of introducing energy storage for all the technologies considered outweighed the potential economic benefit of this strategy for flexible plant operation. The benefit of this analysis is primarily in demonstrating a workflow that examines innovative solutions to increase NPP revenue via TES coupling. HERON’s stochastic capacity and dispatch optimization process used in this work has proven an effective tool in observing and evaluating the impact of introducing storage technologies in a grid energy system.

25 ENERGY STORAGE↗

Advanced HVAC Humidity Control for Hot-Humid Climates

During this project we develop and validate a cost-effective, integrated control solution to improve humidity control and comfort for energy-efficient homes in hot-humid climates. This study focuses on developing a strategy that is effective, field tested, and practical for builders to install with minimal disruption to standard practices. A successful solution would simplify the transition to high-performance humidity control and be the basis for design and installation guidance. By relying on the central system as a starting point, the strategy employed minimizes system complexity and cost for builders, while improving comfort and operating cost for homeowners. The solution strategy was to coordinate the cooling, dehumidification, and ventilation functions of central, ducted HVAC systems to better control indoor humidity, improve occupant thermal comfort, and capture energy savings. The primary strategic goals were to: (1) optimize dehumidification by the central air-conditioning system, particularly during part-load conditions, using conventional equipment with modified control settings and lower system airflows; (2) maximize ventilation during heating/cooling on-cycles, to “bank” and condition outdoor ventilation air, and minimize ventilation during off-cycles; (3) quantify the effectiveness and energy impact of the dehumidification and ventilation strategies, while identifying a metric that would be useful to evaluate latent effectiveness. For the test houses in our study, located in Richmond Hill, Georgia; Houston, Texas; and Monroe, Louisiana we observed: (1) the indoor humidity did not exceed 60% RH during the monitored cooling season for 99% of the time in Richmond Hill, 96% of the time in Houston, and 90% of the time in Monroe; (2) the dehumidification strategy improved the steady-state latent capacity of the HVAC system at design conditions by 16% to 49% at the Houston test house and by 28% to 71% at the Monroe test house, depending on which mode the system was operating in; and (3) the good results at the test houses were primarily due to the amount of time the air-conditioning system operated in ramping or dehumidification modes, or both, particularly during the early cooling season. This study demonstrates that air conditioners or heat pumps with a single-stage compressor can provide good humidity control without the need for a two-stage or variable-stage compressor system. The airflow and control settings for ramping and dehumidification modes are critical to control indoor humidity in hot-humid climates, particularly during part-load and shoulder season conditions. The dehumidification strategy used in this study did not jeopardize the mechanical reliability of the cooling equipment. The strategies used in this study are applicable across various equipment brands, models, and efficiency levels, and also applicable to a broad range of homes in hot-humid climates. Results will vary by specific equipment, location, and house configuration and construction.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy End-Use Patterns in Full-Service Hotels: A Case Study

The U.S. Department of Energy (DOE) recently initiated a program -- Commercial Building Partnerships (CBP) -- to work with private-sector companies in the design of highly-efficient retrofit and new construction projects. Pacific Northwest National Laboratory (PNNL) is conducting a project with a major hotel company to retrofit a full-service, large hotel with the goal of reducing energy consumption by at least 30%. The first step of the project was an intensive metering and monitoring effort aimed at understanding energy end use patterns in the hotel. About 10% of the guest rooms (32), as well as circuits for most of the end uses in public spaces (lighting, elevators, air handlers and other HVAC system components, and various equipment), were equipped with meters. Data are being collected at 1- or 5-minute intervals and downloaded on a monthly basis for analysis. This paper presents results from the first four months of the monitoring effort, which revealed energy end-use consumption patterns, variability of guest room energy use, daily load curves, monthly variations, and other aspects of hotel energy use. Metered end-use data for hotels at this level of detail are not available from any currently-available public sources. This study presents unique information and insight into energy end-use patterns in the lodging sector of commercial buildings and can also serve as a case study of a complex sub-metering project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Challenges and Recent Developments of Neutron Non-Destructive Assay with UO{sub 2}F{sub 2}-Bearing Materials - 17336

In the enrichment process of an operating Gaseous Diffusion Plant (GDP), such as the Portsmouth and Paducah facilities, UF6 gas will immediately hydrolyze forming the chemical compound UO{sub 2}F{sub 2} (Uranyl Fluoride). This mostly happens in Alumina (Al{sub 2}O{sub 3}) traps where the UF6 adsorbs to moistened Alumina pellets forming a UO{sub 2}F{sub 2} layer around the pellet. Similarly, NaF.UF{sub 6} absorption traps produce the complex Na{sub 2}UF{sub 8} which also hydrolyzes when exposed to moist air. UO{sub 2}F{sub 2} can also be formed in many other processes where UF6 gas comes into contact with moisture within structures and objects such as pipes, converters compressors and coolers. When the structures are refurbished, or designated for D and D, UO{sub 2}F{sub 2}-bearing objects are generated both in situ and ex situ requiring fissile (U-235) characterization. In addition, ex situ waste streams are generated when UO{sub 2}F{sub 2}-bearing materials are placed in drummed or boxed waste containers. Gamma spectroscopy Non-Destructive Assay (NDA) is commonly utilized to characterize UO{sub 2}F{sub 2}-bearing waste but generally has high associated Total Measurement Uncertainties (TMU's) and, in some cases, Data Quality Objectives (DQO's) cannot be met. In addition, high UO{sub 2}F{sub 2} mass loadings, such as hold-up materials, require gamma modeling when infinitely thick to the Uranium energy lines. A common neutron NDA technique, or method, is to exploit the neutrons generated from the F-19(a, n)Na-22 reaction which has an appreciable reaction cross-section. The isotopes of Uranium are a-emitters, and, in particular, U-234 has a significantly higher a-decay reaction cross-section leading to a significant relative neutron Specific Activity (nSA). Neutron NDA is appealing since, in some cases, it has potentially lower TMU's than gamma NDA and neutron detector slabs facilitate surrounding large, complex-shaped, objects. Characterizing UO{sub 2}F{sub 2}-bearing waste for fissile content using neutrons generated from U-234, requires the U-235/U-234 ratio as well as the enrichment as well as the corresponding nSA's. It is also noted that U-238 has a considerable, relative, spontaneous fission nSA and this is a higher concern for low-enrichments where the mass of U-238 dominates. Additional neutron interfering elements include cosmic-ray induced spallation within the objects and background from other, in situ, UO{sub 2}F{sub 2}-bearing objects. In this paper we present the challenges and recently developed hardware and algorithmic strategies for quantifying fissile mass both in situ and ex situ using neutron NDA that works in conjunction to gamma spectroscopy NDA, or process knowledge, for objects and drummed/boxed waste containing UO{sub 2}F{sub 2}-bearing materials leading to minimal TMU's and achievable DQO's. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A constitutive mechanical model for gas hydrate bearing sediments incorporating inelastic mechanisms

Gas hydrate bearing sediments (HBS) are natural soils formed in permafrost and sub-marine settings where the temperature and pressure conditions are such that gas hydrates are stable. If these conditions shift from the hydrate stability zone, hydrates dissociate and move from the solid to the gas phase. Hydrate dissociation is accompanied by significant changes in sediment structure and strongly affects its mechanical behavior (e.g., sediment stiffenss, strength and dilatancy). The mechanical behavior of HBS is very complex and its modeling poses great challenges. Here this paper presents a new geomechanical model for hydrate bearing sediments. The model incorporates the concept of partition stress, plus a number of inelastic mechanisms proposed to capture the complex behavior of this type of soil. This constitutive model is especially well suited to simulate the behavior of HBS upon dissociation. The model was applied and validated against experimental data from triaxial and oedometric tests conducted on manufactured and natural specimens involving different hydrate saturation, hydrate morphology, and confinement conditions. Particular attention was paid to model the HBS behavior during hydrate dissociation under loading. The model performance was highly satisfactory in all the cases studied. It managed to properly capture the main features of HBS mechanical behavior and it also assisted to interpret the behavior of this type of sediment under different loading and hydrate conditions.

42 ENGINEERING↗

Amorphous Pd-Loaded Ti 4 O 7 Electrode for Direct Anodic Destruction of Perfluorooctanoic Acid

In this work we present a novel Ti 4 O 7 -based electrode loaded with amorphous Pd clusters that achieve efficient anodic destruction of perfluorooctanoic acid (PFOA), a persistent water pollutant with significant environmental and human health concerns. These amorphous Pd clusters were characterized by the disordered, noncrystalline arrangement of Pd single atoms in close proximity, in contrast to crystalline Pd nanoparticles that have been often employed to tailor the electronic properties of an electrode. We found that the Ti 4 O 7 electrode loaded with amorphous Pd clusters significantly outperformed the Ti 4 O 7 electrode loaded with crystalline Pd particles due to enhanced electron transfer through dominant Pd–O bonds. Combined with the efficient binding of PFOA and its degradation intermediates to the fluorinated electrode surface, this electrode was capable of mineralizing PFOA and releasing fluoride as F – . The reaction pathway was found to proceed without involving reactive oxygen species and therefore was not quenched by common anions in complex natural water systems such as chloride ions.

36 MATERIALS SCIENCE↗