Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BACKGROUND NOISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

AlGaN/InGaN Photocathode Development

An increase in quantum efficiency in photodetectors could result in a proportional reduction in the area of atmospheric Cherenkov telescopes and an even larger reduction in cost. We report on the development of high quantum efficiency, high gain, UV/blue photon-counting detectors based on AlGaN/InGaN photocathode heterostructures grown by molecular beam epitaxy. This research could eventually result in nearly ideal light detectors with a number of distinct advantages over existing technologies for numerous applications in high-energy physics and particle astrophysics. Potential advantages include much lower noise detection, better stability and radiation resistance than other cathode structures, high VUV sensitivity and very low radioactive background levels for deep underground experiments, and high detection efficiency for the detection of individual VUV-visible photons. We are also developing photocathodes with intrinsic gain, initially improving the detection efficiency of hybrid semiconductor-vacuum tube devices and eventually leading to a new type of all-solid-state photomultiplier device.

79 ASTRONOMY AND ASTROPHYSICS↗

Implementation of a 1-2 keV point-projection x-ray spectrometer on the National Ignition Facility

A point-projection soft X-ray Opacity Spectrometer (OpSpec) has been implemented to measure X-ray spectra from ~1 to 2 keV on the National Ignition Facility (NIF). Measurement of such soft X-rays with open-aperture point-projection detectors is challenging because only very thin filters may be used to shield the detector from the hostile environment. OpSpec diffracts X-rays from 540 to 2100 eV off a potassium (or rubidium) acid phthalate (KAP or RbAP) crystal onto either image plates or, most recently, X-ray films. A “sacrificial front filter” strategy is used to prevent crystal damage, while 2 or 3 rear filters protect the data. Since May 2017, OpSpec has been recording X-ray transmission data for iron-magnesium plasmas on the NIF, at “Anchor 1” plasma conditions (temperature ~150 eV, density ~7 × 10 21 e - /cm 3 ). Upgrades improved OpSpec’s performance on 6 NIF shots in August and December 2017, with reduced backgrounds and 100% data return using filter stacks as thin as 2.9 μm (total). We conclude that photometric noise is beginning to meet requirements, and further work will reduce systematic errors.

47 OTHER INSTRUMENTATION↗

Gaussianity of LISA's confusion backgrounds

Data analysis for the proposed Laser Interferometer Space Antenna (LISA) will be complicated by the huge number of sources in the LISA band. In the frequency band {approx}10{sup -4}-2x10{sup -3} Hz, galactic white dwarf binaries (GWDBs) are sufficiently dense in frequency space that it will be impossible to resolve most of them, and ''confusion noise'' from the unresolved Galactic binaries will dominate over instrumental noise in determining LISA's sensitivity to other sources in that band. Confusion noise from unresolved extreme-mass-ratio inspirals (EMRIs) could also contribute significantly to LISA's total noise curve. To date, estimates of the effect of LISA's confusion noise on matched-filter searches and their detection thresholds have generally approximated the noise as Gaussian, based on the central limit theorem. However in matched-filter searches, the appropriate detection threshold for a given class of signals may be located rather far out on the tail of the signal-to-noise probability distribution, where a priori it is unclear whether the Gaussian approximation is reliable. Using the Edgeworth expansion and the theory of large deviations, we investigate the probability distribution of the usual matched-filter detection statistic, far out on the tail of the distribution. We apply these tools to four somewhat idealized versions of LISA data searches: searches for EMRI signals buried in GWDB confusion noise, and searches for massive black hole binary signals buried in (i) GWDB noise, (ii) EMRI noise, and (iii) a sum of EMRI noise and Gaussian noise. Assuming reasonable short-distance cutoffs in the populations of confusion sources (since the very closest and hence strongest sources will be individually resolvable), modifications to the appropriate detection threshold, due to the non-Gaussianity of the confusion noise, turn out to be quite small for realistic cases. The smallness of the correction is partly due to the fact that these three types of sources evolve on quite different time scales, so no single background source closely resembles any search template. We also briefly discuss other types of LISA searches where the non-Gaussianity of LISA's confusion backgrounds could perhaps have a much greater impact on search reliability and efficacy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low Energy LArTPC Signal Detection Using Anomaly Detection

Extracting low-energy signals from LArTPC detectors is useful, for example, for detecting supernova events or calibrating the energy scale with argon-39. However, it is difficult to efficiently extract the signals because of noise. We propose using a 1DCNN to select wire traces that have a signal. This efficiently suppresses the background while still being efficient for the signal. This is then followed by a 1D autoencoder to denoise the wire traces. At that point the signal waveform can be cleanly extracted. In order to make this processing efficient, we implement the two networks on an FPGA. In particular we use hls4ml to produce HLS from the Keras models for both the 1DCNN and the autoencoder. We deploy them on an AMD/Xilinx Alveo U55C using the Vitis software platform.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Novel Signatures Beyond the Standard Model: From Extreme Environments to Precision Measurements

Most of our universe is dark. It is dark literally—visible matter makes up only 5% of the energy density—and conceptually, as many outstanding questions remain unsolved. The discovery of particle dark matter would shed light on our dark universe and throw open a window on the highest energy scales. This research made progress toward dark matter and new particle searches in three ways. Extreme compact objects, such as black holes, neutron stars, and stellar cores, can parametrically increase the production rates of feebly interacting particles and yield observable signatures. Specifically, a process known as superradiance leads to exponential growth of the number of ultralight particles gravitationally bound to rotating black holes, and turns astrophysical black holes into particle detectors. This research broadened the scope of applicability of superradiance studies to particles with a wide range of interactions and masses, predicting multi messenger signals. When ultralight particles are produced as dark matter in the early universe, they can be detected directly in laboratory experiments. However, these feebly interacting particles lead to small signals that are inevitably difficult to tease out from backgrounds; their detection requires the theoretical development of unique signatures that can be searched for in low-noise experiments. Some dark matter particles could be detectable with thin film metamaterials combined with low noise single-photon detectors. This research develop the theoretical framework and supported experimental efforts for ambitious searches for a wider class of ultralight particles. Overall, the outcome of this theoretical particle physics program developed novel signatures of new dark matter particles, and thereby expanded the particle parameter space which can be explored with astrophysical observations and precision experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Apollo lunar sounder experiment

The four basic data products from the ALSE are sounding, profiling, imaging, and noise measurements. Attention was concentrated on the first three products, and both theory and preliminary results are presented. Background information is presented on the experiment and on the data products. Preliminary examples of the types of analyses that can be performed and the conclusions to which they can lead are included. Preliminary analysis of the data for subsurface features was successful in indicating with a high probability the capability of the ALSE to achieve its fundamental goal of substrate sounding. The imagery and profiling data are useful immediately for geologic interpretation, as demonstrated.

Phillips, R. J.↗

High-voltage spark atomic emission detector for gas chromatography

A dc-powered, double-gap, miniature nanosecond spark source for emission spectrochemical analysis of gas chromatographic effluents is described. The spark is formed between two thoriated tungsten electrodes by the discharge of a coaxial capacitor. The spark detector is coupled to the gas chromatograph by a heated transfer line. The gas chromatographic effluent is introduced into the heated spark chamber where atomization and excitation of the effluent occurs upon breakdown of the analytical gap. A microcomputer-controlled data acquisition system allows the implementation of time-resolution techniques to distinguish between the analyte emission and the background continuum produced by the spark discharge. Multiple sparks are computer averaged to improve the signal-to-noise ratio. The application of the spark detector for element-selective detection of metals and nonmetals is reported.

Calkin, C. L.↗

Consequences of wave-particle interactions on chaotic acceleration

The recent model of Ashour-Abdalla et al. (1991) has proposed that the earth's plasma sheet can be formed by chaotic acceleration in a magnetotail-like field configuration. The ion velocity distributions created by chaotic acceleration have unstable features and represent robust free energy sources for kinetic plasma waves that can modify the original distributions. In the plasma sheet boundary layer, field-aligned ion beamlets are formed which drive a host of instabilities creating a broadbanded noise spectrum and cause thermal spreading of the beamlets. In addition, there is strong heating of any cold background plasma that may be present. In the central plasma sheet, ion antiloss cone distributions are created which are unstable to very low frequency waves that saturate by filling the antiloss cone.

Schriver, David↗

Measurement of atmospheric OH by titration of near-IR fluorescent dyes

Recent research has shown that certain polymethine dyes can be detected at ultratrace levels (greater than or equal to 6x10(exp -14) M) in solution by fluorimetry. These detection limits are possible because of the inherent sensitivity of fluorescence techniques, because the dyes fluoresce in the near infrared region where background interference is negligible, and because powerful infrared diode lasers are now available to improve the signal to noise ratio. Other work has shown that the hydroxyl radical destroys the ability of polymethine dyes to fluoresce. These observations form the basis for a new hydroxyl radical detector that is essentially a fluorometric titrator. Theoretically, the detector should show an acceptable sensitivity and response time. Assuming that the atmospheric HO concentration is about 10(exp -11) moles m(exp -3) (i.e. 10(exp 6) molecules cm(exp -3)), then 10 L of air 'titrated' with 20 mL of 10(exp -11) M dye solution (an easily detected concentration) should result in a drop in the fluorescent signal of 50 percent - a readily detectable change. At a flow rate of 3 L min(exp -1) the sampling time would be 3 minutes. The biggest potential problem is selectivity: other oxidants may also cause the fluorescence signal to be lost. The chemistry of polymethine dyes has not been studied in detail and so no quantitative data are available. However, a survey of the literature suggests that in general HO should react up to six orders of magnitude faster than HO2 and other radicals such as RO2 and RO. It should also react much more rapidly than H2O2 and O3. Thus it may be possible to discriminate kinetically against potential interfering substances. It was shown in the laboratory that 10(exp -4) M H2O2 has little effect on the absorption spectrum of the dye IR125 over a period of hours but that the band at 780 nm is slowly lost in water over a period of days even under argon in the dark. By contrast, DMSO solutions of IR125 are stable.

Betterton, Eric A.↗

Planetary Candidates Observed by Kepler, III: Analysis of the First 16 Months of Data

New transiting planet candidates are identified in sixteen months (May 2009 - September 2010) of data from the Kepler spacecraft. Nearly five thousand periodic transit-like signals are vetted against astrophysical and instrumental false positives yielding 1091 viable new planet candidates, bringing the total count up to over 2,300. Improved vetting metrics are employed, contributing to higher catalog reliability. Most notable is the noise-weighted robust averaging of multiquarter photo-center offsets derived from difference image analysis which identifies likely background eclipsing binaries. Twenty-two months of photometry are used for the purpose of characterizing each of the new candidates. Ephemerides (transit epoch, T{sub 0}, and orbital period, P) are tabulated as well as the products of light curve modeling: reduced radius (R{sub P}/R{sub {star}}), reduced semi-major axis (d/R{sub {star}}), and impact parameter (b). The largest fractional increases are seen for the smallest planet candidates (197% for candidates smaller than 2R{sub {circle_plus}} compared to 52% for candidates larger than 2R{sub {circle_plus}}) and those at longer orbital periods (123% for candidates outside of 50 day orbits versus 85% for candidates inside of 50 day orbits). The gains are larger than expected from increasing the observing window from thirteen months (Quarter 1 - Quarter 5) to sixteen months (Quarter 1 - Quarter 6). This demonstrates the benefit of continued development of pipeline analysis software. The fraction of all host stars with multiple candidates has grown from 17% to 20%, and the paucity of short-period giant planets in multiple systems is still evident. The progression toward smaller planets at longer orbital periods with each new catalog release suggests that Earth-size planets in the Habitable Zone are forthcoming if, indeed, such planets are abundant.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microwave background fluctuations due to the Sunyaev-Zel'dovich effects in pancakes

We calculate distortions in the microwave background radiation from the Sunyaev-Zel'dovich effect, produced by hot gas in large (approximately 100 Mpc) pancakes. The large-scale distribution of the pancakes is taken to be that of a Voronoi foam. Fluctuations for this scenario are estimated to be on the order of delta T/T is approximately 10(exp -5). Using computer simulations, we produce several 32 deg x 32 deg images with 0.25 deg resolution. These images show characteristic linear features produced when a pancake is viewed nearly edge-on. By calculating the two-point and the degenerate three-point correlation functions, we are able to statistically detect such non-Gaussian features even in the presence of a relatively large amount of Gaussian noise. The degenerate three-point correlation function is found to be particularly useful since it is insensitive to correlated Gaussian noise. We also smooth our data over a 7 deg Full Width at Half Maximum (FWHM) Gaussian window to simulate the Cosmic Background Explorer Satellite (COBE) observations. We find that under such low-resolution conditions, the features are highly suppressed.

Subbarao, M. U.↗

A model for chorus associated electrostatic bursts

The linear theory of the generation of electrostatic bursts of noise by electrons trapped in chorus wave packets is developed for a finite temperature electron beam and a Maxwellian elecron and ion background. The growth rates determined qualitatively in good agreement with those obtained by previous authors from a more idealized model. Two connected instability mechanisms seem to be occurring: a beam plasma (electron-ion two-stream) instability commonly associated with intensification of the chorus power levels, and a transitional or borderline resistive medium instability commonly associated with chorus hooks. The physical reasons for the two mechanisms is discussed. In the second case electron beams are difficult to identify in the particle data. An expression is obtained for the maximum growth rate in terms of the ratios of the beam and electron thermal velocities to the beam velocity, and of the beam density to plasma density. It is anticipated that this may allow the observed peak in the electrostatic noise spectrum to be used as a diagnostic for the beam characteristics. Previously announced in STAR as N84-12832

Grabbe, C. L.↗

Foreground-Immune Cosmic Microwave Background Lensing with Shear-Only Reconstruction

Cosmic microwave background (CMB) lensing from current and upcoming wide-field CMB experiments such as AdvACT, SPT-3G and Simons Observatory relies heavily on temperature (versus polarization). In this regime, foreground contamination to the temperature map produces significant lensing biases, which cannot be fully controlled by multifrequency component separation, masking, or bias hardening. Here in this Letter, we split the standard CMB lensing quadratic estimator into a new set of optimal “multipole” estimators. On large scales, these multipole estimators reduce to the known magnification and shear estimators, and a new shear B-mode estimator. We leverage the different symmetries of the lensed CMB and extragalactic foregrounds to argue that the shear-only estimator should be approximately immune to extragalactic foregrounds. We build a new method to compute, separately and without noise, the primary, secondary, and trispectrum biases to CMB lensing from foreground simulations. Using this method, we demonstrate that the shear estimator is, indeed, insensitive to extragalactic foregrounds, even when applied to a single-frequency temperature map contaminated with cosmic infrared background, thermal Sunyaev-Zel’dovich, kinematic Sunyaev-Zel’dovich, and radio point sources. This dramatic reduction in foreground biases allows us to include higher temperature multipoles than with the standard quadratic estimator, thus, increasing the total lensing signal-to-noise ratio beyond the quadratic estimator. In addition, magnification-only and shear B-mode estimators provide useful diagnostics for potential residuals.

79 ASTRONOMY AND ASTROPHYSICS↗

Prospects for direct detection of inflationary gravitational waves by next generation interferometric detectors

We study the potential impact of detecting the inflationary gravitational wave background by the future space-based gravitational wave detectors, such as DECIGO and BBO. The signal-to-noise ratio of each experiment is calculated for chaotic/natural/hybrid inflation models by using the precise predictions of the gravitational wave spectrum based on numerical calculations. We investigate the dependence of each inflation model on the reheating temperature which influences the amplitude and shape of the spectrum, and find that the gravitational waves could be detected for chaotic/natural inflation models with high reheating temperature. From the detection of the gravitational waves, a lower bound on the reheating temperature could be obtained. The implications of this lower bound on the reheating temperature for particle physics are also discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Threshold magnitudes for a multichannel correlation detector in background seismicity

Colocated explosive sources often produce correlated seismic waveforms. Multichannel correlation detectors identify these signals by scanning template waveforms recorded from known reference events against "target" data to find similar waveforms. This screening problem is challenged at thresholds required to monitor smaller explosions, often because non-target signals falsely trigger such detectors. Therefore, it is generally unclear what thresholds will reliably identify a target explosion while screening non-target background seismicity. Here, we estimate threshold magnitudes for hypothetical explosions located at the North Korean nuclear test site over six months of 2010, by processing International Monitoring System (IMS) array data with a multichannel waveform correlation detector. Our method (1) accounts for low amplitude background seismicity that falsely triggers correlation detectors but is unidentifiable with conventional power beams, (2) adapts to diurnally variable noise levels and (3) uses source-receiver reciprocity concepts to estimate thresholds for explosions spatially separated from the template source. Furthermore, we find that underground explosions with body wave magnitudes m b = 1.66 are detectable at the IMS array USRK with probability 0.99, when using template waveforms consisting only of P -waves, without false alarms. We conservatively find that these thresholds also increase by up to a magnitude unit for sources located 4 km or more from the Feb.12, 2013 announced nuclear test.

54 ENVIRONMENTAL SCIENCES↗

JWST Noise Floor. I. Random Error Sources in JWST NIRCam Time Series

James Webb Space Telescope (JWST) transmission and emission spectra will provide invaluable glimpses of transiting exoplanet atmospheres, including possible biosignatures. This promising science from JWST, however, will require exquisite precision and understanding of systematic errors that can impact the time series of planets crossing in front of and behind their host stars. Here, we provide estimates of the random noise sources affecting JWST Near-Infrared Camera (NIRCam) time-series data on the integration-to-integration level. We find that 1/f noise can limit the precision of grism time series for two groups (230–1000 ppm depending on the extraction method and extraction parameters), but will average down like the square root of N frames/reads. The current NIRCam grism time-series mode is especially affected by 1/f noise because its GRISMR dispersion direction is parallel to the detector fast-read direction, but could be alleviated in the GRISMC direction. Care should be taken to include as many frames as possible per visit to reduce this 1/f noise source: thus, we recommend the smallest detector subarray sizes one can tolerate, four output channels, and readout modes that minimize the number of skipped frames (RAPID or BRIGHT2). We also describe a covariance-weighting scheme that can significantly lower the contributions from 1/f noise as compared to sum extraction. We evaluate the noise introduced by pre-amplifier offsets, random telegraph noise, and high dark current resistor capacitor (RC) pixels and find that these are correctable below 10 ppm once background subtraction and pixel masking are performed. We explore systematic error sources in a companion paper.

79 ASTRONOMY AND ASTROPHYSICS↗

A low noise infrared spot scanner for testing detector arrays

A low noise spot scanner has been built for use in testing the performance of infrared detector arrays for NASA's IR detector technology development program and the University of California's MICRO program. The scanner provides a convenient low noise detector test environment and a wide range of test conditions including versatile temperature control of the detector, ambient background, and blackbody source temperature and control of spot size, color, and brightness.

Puetter, R. C.↗

Systematic aspects of direct extrasolar planet detection

Using the first optical observatory in space, the Hubble Space Telescope, images of possible extrasolar planets will have poor contrast against the background of diffracted and scattered starlight. The very long exposure time required to achieve an adequate signal-to-noise ratio will make their detection infeasible. For a future telescope, a 16-fold increase in either the smoothness of the collecting area of the optics would reduce the exposure time to a tolerable value, but the contrast would remain low and the required photometric precision high. In this situation, the feasibility of detection would be contingent on the careful identification and control of systematic errors.

Brown, Robert A.↗