Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ARTIFACTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Chiral Extrapolations of the $\boldsymbol{ρ(770)}$ Meson in $\mathbf{N_f=2+1}$ Lattice QCD Simulations

Several lattice QCD simulations of meson-meson scattering in p-wave and Isospin = 1 in Nf = 2 + 1 flavours have been carried out recently. Unitarized Chiral Perturbation Theory is used to perform extrapolations to the physical point. In contrast to previous findings on the analyses of Nf = 2 lattice data, where most of the data seems to be in agreement, some discrepancies are detected in the Nf = 2 + 1 lattice data analyses, which could be due to different masses of the strange quark, meson decay constants, initial constraints in the simulation, or other lattice artifacts. In addition, the low-energy constants are compared to the ones from a recent analysis of Nf = 2 lattice data.

Molina, Raquel↗

The Scalable Reasoning System: Lightweight Visualization for Distributed Analytics

A central challenge in visual analytics is the creation of accessible, widely distributable analysis applications that bring the benefits of visual discovery to as broad a user base as possible. Moreover, to support the role of visualization in the knowledge creation process, it is advantageous to allow users to describe the reasoning strategies they employ while interacting with analytic environments. We introduce an application suite called the Scalable Reasoning System (SRS), which provides web-based and mobile interfaces for visual analysis. The service-oriented analytic framework that underlies SRS provides a platform for deploying pervasive visual analytic environments across an enterprise. SRS represents a “lightweight” approach to visual analytics whereby thin client analytic applications can be rapidly deployed in a platform-agnostic fashion. Client applications support multiple coordinated views while giving analysts the ability to record evidence, assumptions, hypotheses and other reasoning artifacts. We describe the capabilities of SRS in the context of a real-world deployment at a regional law enforcement organization.

analytic reasoning↗

Data Reliability in BIM and Performance Analytics: A Survey of Contemporary AECO Practice

As awareness around building energy consumption increases, practitioners are encouraged to consider performance aspects regarding the built environment more closely and find ways to improve its efficiency. Improvements in building information modeling (BIM) and building performance simulation (BPS) tools present opportunities to facilitate information communication with a wider range of stakeholders. The building sector can benefit from the integration of performance informatics; however, there has been limited success in utilizing available technologies that promote data integration and management in favor of enriching our knowledge and understanding of buildings as artifacts of information. This phenomenon was investigated by conducting a survey, together with a review of relevant literature, to depict the relevant challenges and opportunities for the architecture, engineering, construction, and owner-operated (AECO) industry, as it undergoes digital transformation, as well as the working practices that have formed around them. It is argued that the current tools available to practitioners do not support effective data serialization between design and analytics processes, affecting the collaboration between team members. Lastly, a series of functional goals are proposed to support a higher level of reliability in the ways information is mobilized, by rethinking the technologies and methods for organizing information systems.

42 ENGINEERING↗

Lead-free acoustic emission sensors

Acoustic emission (AE) sensors have been fabricated using both soft- and hard-type lead-free (Na{sub 0.5}K{sub 0.5})NbO{sub 3}-based ceramics. The acoustic and electromechanical properties of the ceramics have been determined using the resonance technique. The lead-free AE sensors were calibrated using a laser source and compared to a commercial sensor. A lead zirconate titanate (PZT) 5H ceramics AE sensor has also been fabricated and calibrated for comparison. It was found that the sensitivity of lead-free AE sensors is comparable to that of the lead-based PZT sensor. To evaluate the sensors for potential application, they have been used in the detection of AE in an impact test. The lead-free sensors can reproduce AE signals accurately without giving artifacts and have potential use in commercial AE systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

What Makes a Good Mammography Image?

The early detection of breast cancer requires a high quality image, which is provided by mammography. The main indicators of technical image quality, contrast, spatial resolution, noise and absence of artifacts, are described, as well as the elements responsible for their values in a mammography unit. Since screening mammography is applied to asymptomatic subjects, the optimization of the imparted dose compatible with required image quality is of importance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of x-ray microfocus computed tomography as an imaging tool for porous structures

X-ray microfocus computed tomography (micro-CT) is recently put forward to qualitatively and quantitatively characterize the internal structure of porous materials. However, it is known that artifacts such as the partial volume effect are inherently present in micro-CT images, thus resulting in a visualization error with respect to reality. This study proposes a validation protocol that in the future can be used to quantify this error for porous structures in general by matching micro-CT tomograms to microscopic sections. One of the innovations of the protocol is the opportunity to reconstruct an interpolated micro-CT image under the same angle as the physical cutting angle of the microscopic sections. Also, a novel thresholding method is developed based on matching micro-CT and microscopic images. In this study, titanium porous structures are assessed as proof of principle. It is concluded for these structures that micro-CT visualizes 89% of the total amount of voxels (solid and pore) correctly. However, 8% represents an overestimation of the real structure and 3% are real structural features not visualized by micro-CT. When exclusively focusing on the solid fraction in both the micro-CT and microscopic images, only an overestimation of about 5% is found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron transport in open systems from finite-size calculations: Examination of the principal layer method applied to linear gold chains

We describe the occurrence of computational artifacts when the principal layer method is used in combination with the cluster approximation for the calculation of electronic transport properties of nanostructures. For a one-dimensional gold chain we observe an unphysical band in the band structure. The artificial band persists for large principal layers and for large buffer sizes. We demonstrate that the assumption of equality between Hamiltonian elements of neighboring layers is no longer valid and that a discontinuity is introduced in the potential at the layer transition. The effect depends on the basis set. When periodic boundary conditions are imposed and the k-space sampling is converged, the discontinuity disappears and the principal layer method can be applied correctly using a linear combination of atomic orbitals as basis set.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Fast tomographic methods for the tokamak ISTTOK

The achievement of long duration, alternating current discharges on the tokamak IST-TOK requires a real-time plasma position control system. The plasma position determination based on magnetic probes system has been found to be inadequate during the current inversion due to the reduced plasma current. A tomography diagnostic has been therefore installed to supply the required feedback to the control system. Several tomographic methods are available for soft X-ray or bolo-metric tomography, among which the Cormack and Neural networks methods stand out due to their inherent speed of up to 1000 reconstructions per second, with currently available technology. This paper discusses the application of these algorithms on fusion devices while comparing performance and reliability of the results. It has been found that although the Cormack based inversion proved to be faster, the neural networks reconstruction has fewer artifacts and is more accurate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interaction Between the Himalaya and the Flexed Indian Plate--Spatial Fluctuations in Seismic Hazard in India in the Past Millennium?

Between the tenth and early 16th centuries three megaquakes allowed most of the northern edge of the Indian plate to slip 20-24 m northward relative to the overlying Himalaya. Although the renewal time for earthquakes with this large amount of slip is less than 1300 years given a geodetic convergence rate of 16-20 mm/yr, recently developed scaling laws for the Himalaya suggest that the past 200 years of great earthquakes may be associated with slip of less than 10 m and renewal times of approximately 500 years. These same theoretical models show that the rupture lengths of the Himalaya's Medieval earthquakes (300-600 km) are too short to permit 24 m of slip given the relationships demonstrated by recent events. There is thus reason to suppose that recent earthquakes may have responded to different elastic driving forces from those that drove the megaquakes of Medieval times.An alternative source of energy to drive Himalayan earthquakes exists in the form of the elastic and gravitational energy stored in flexure of the Indian plate. The flexure is manifest in the form of a 200-450 m high bulge in central India, which is sustained by the forces of collision and by the end-loading of the plate by the Himalaya and southern Tibet. These flexural stresses are responsible for earthquakes in the sub-continent. The abrupt release of stress associated with the northward translation of the northern edge of the Indian plate by 24 m, were the process entirely elastic, would result in a deflation of the crest of the bulge by roughly 0.8 m. Geometrical changes, however, would be moderated by viscous rheologies in the plate and by viscous flow in the mantle in the following centuries.The hypothesized relaxation of flexural geometry following the Himalayan megaquake sequence would have the effect of backing-off stresses throughout central India resulting in quiescence both in the Himalaya and the Indian plate. The historical record shows an absence of great Himalayan earthquakes in the late 16th to early 19th centuries, and colonial records for this period contain few records of earthquakes in central India. Although this may be an artifact caused by a poor recorded history, it is unlikely that Mw>8.2 earthquakes have escaped notice in the Mughal or early colonial histories.Recent mid-plate earthquakes in India may thus represent a redevelopment of flexural stressing of the Indian plate. Their return also signifies the development of stresses in the Himalaya that will eventually be released in great Himalayan earthquakes.

58 GEOSCIENCES↗

Invited Article: Deep Impact instrument calibration

Calibration of NASA's Deep Impact spacecraft instruments allows reliable scientific interpretation of the images and spectra returned from comet Tempel 1. Calibrations of the four onboard remote sensing imaging instruments have been performed in the areas of geometric calibration, spatial resolution, spectral resolution, and radiometric response. Error sources such as noise (random, coherent, encoding, data compression), detector readout artifacts, scattered light, and radiation interactions have been quantified. The point spread functions (PSFs) of the medium resolution instrument and its twin impactor targeting sensor are near the theoretical minimum [{approx}1.7 pixels full width at half maximum (FWHM)]. However, the high resolution instrument camera was found to be out of focus with a PSF FWHM of {approx}9 pixels. The charge coupled device (CCD) read noise is {approx}1 DN. Electrical cross-talk between the CCD detector quadrants is correctable to <2 DN. The IR spectrometer response nonlinearity is correctable to {approx}1%. Spectrometer read noise is {approx}2 DN. The variation in zero-exposure signal level with time and spectrometer temperature is not fully characterized; currently corrections are good to {approx}10 DN at best. Wavelength mapping onto the detector is known within 1 pixel; spectral lines have a FWHM of {approx}2 pixels. About 1% of the IR detector pixels behave badly and remain uncalibrated. The spectrometer exhibits a faint ghost image from reflection off a beamsplitter. Instrument absolute radiometric calibration accuracies were determined generally to <10% using star imaging. Flat-field calibration reduces pixel-to-pixel response differences to {approx}0.5% for the cameras and <2% for the spectrometer. A standard calibration image processing pipeline is used to produce archival image files for analysis by researchers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial Image Quality and Clinical Experience with New CR Digital Mammography System: A Phantom and Clinical Study

The goal of the study was to evaluate the first CR digital mammography system ( registered Konica-Minolta) in Mexico in clinical routine for cancer detection in a screening population and to determine if high resolution CR digital imaging is equivalent to state-of-the-art screen-film imaging. The mammograms were evaluated by two observers with cytological or histological confirmation for BIRADS 3, 4 and 5. Contrast, exposure and artifacts of the images were evaluated. Different details like skin, retromamillary space and parenchymal structures were judged. The detectability of microcalcifications and lesions were compared and correlated to histology. The difference in sensitivity of CR Mammography (CRM) and Screen Film Mammography (SFM) was not statistically significant. However, CRM had a significantly lower recall rate, and the lesion detection was equal or superior to conventional images. There is no significant difference in the number of microcalcifications and highly suspicious calcifications were equally detected on both film-screen and digital images. Different anatomical regions were better detectable in digital than in conventional mammography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of interlayer trapping and detrapping mechanisms on the electrical characterization of hafnium oxide/silicon nitride stacks on silicon

Al/HfO{sub 2}/SiN{sub x}:H/n-Si metal-insulator-semiconductor capacitors have been studied by electrical characterization. Films of silicon nitride were directly grown on n-type silicon substrates by electron cyclotron resonance assisted chemical vapor deposition. Silicon nitride thickness was varied from 3 to 6.6 nm. Afterwards, 12 nm thick hafnium oxide films were deposited by the high-pressure sputtering approach. Interface quality was determined by using current-voltage, capacitance-voltage, deep-level transient spectroscopy (DLTS), conductance transients, and flatband voltage transient techniques. Leakage currents followed the Poole-Frenkel emission model in all cases. According to the simultaneous measurement of the high and low frequency capacitance voltage curves, the interface trap density obtained for all the samples is in the 10{sup 11} cm{sup -2} eV{sup -1} range. However, a significant increase in this density of about two orders of magnitude was obtained by DLTS for the thinnest silicon nitride interfacial layers. In this work we probe that this increase is an artifact that must be attributed to traps existing at the HfO{sub 2}/SiN{sub x}:H intralayer interface. These traps are more easily charged or discharged as this interface comes near to the substrate, that is, as thinner the SiN{sub x}:H interface layer is. The trapping/detrapping mechanism increases the capacitance transient and, in consequence, the DLTS measurements have contributions not only from the insulator/substrate interface but also from the HfO{sub 2}/SiN{sub x}:H intralayer interface.

36 MATERIALS SCIENCE↗

On PbTiO{sub 3}-(111)-Pt interfacial layers and their x-ray photoelectron spectroscopy signature

In this work emphasis is placed on the investigation of interfacial layers between sol-gel processed PbTiO{sub 3} (PTO) thin films and (111)Pt terminated silicon substrates. The methods used are x-ray diffraction, x-ray photoelectron spectroscopy (XPS) combined with depth profiling, and atomic force microscopy (AFM). In order to avoid artifacts related to ion bombardment, e.g., reduction of Pb ions and preferential sputtering, gentle argon ion bombardment conditions were first derived. AFM investigations of native and ion bombarded films at different stages of depth profiling show that the films are homogenously sputtered, whereby the film roughness remains practically unchanged in the course of sputtering. An annealing treatment at 550 deg. C under reducing atmosphere was used to provoke the formation of an interfacial intermetallic (111)Pt{sub x}Pb phase, which is shown to coexist with an amorphous oxide film. This could allow us to establish the XPS signature of the intermetallic phase. A negative shift of the Pt (4f) binding energy and a large full width at half maximum of the Pb (4f) peak are the attributes of this signature. PTO-film annealing in air at temperatures between 350 and 600 deg. C leads to the formation of the perovskite phase, starting at 500 deg. C, directly from the amorphous phase. Based on its derived XPS signature it is shown that the intermetallic phase still exists at the interface with variable thickness depending on the annealing temperature. The pronounced (111) texture of the PTO-crystallized films is thought to be the direct consequence of this intermetallic template layer. It is also shown that the outermost surface of the PTO film is enriched with PbO as a result of segregation phenomena.

36 MATERIALS SCIENCE↗

Conformal Doping of FINFETs: a Fabrication and Metrology Challenge

Whereas the introduction of 3D-dimensional devices such as FINFETs may be a solution for next generation technologies, they do represent significant challenges with respect to the doping strategies and the junction characterization. Aiming at a conformal doping, classical beam implants fail due to the differences in impact angle, ion incorporation efficiency and the effect of wafer rotation. Moreover shadowing represents an additional limitation for larger tilt angles when considering closely spaced FINs. Plasma immersion doping is an alternative approach which holds the promise of conformality but is also quite challenging and relies on secondary processes such as resputtering, deposition and in diffusion etc. Its implementation is compromised by concurrent artifacts, sputter erosion being the most important one. In support of these developments the measurement of the 3D-dopant distribution and the identification of conformality is essential requiring adequate metrology such as Scanning Spreading Resistance Microscopy, SIMS through FINs, resistors and the Tomographic Atomprobe.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electron Holography Characterization of Shallow Junction Fabricated By Diffusion-less Process for Sub-30 nm Gate-Length MOSFETs

Cross-sectional electron holography was used for two-dimensional potential mapping of source/drain extensions (SDEs) in scaled MOSFETs fabricated using state-of-the-art junction formation technology. First, we show that specimen-preparation artifacts, which have prevented detailed examinations of scaled SDEs, are significantly reduced by using low-energy backside Ar{sup +} milling. Next, we demonstrate that electron holography clearly reveals very shallow (10-nm-deep) SDE junction profiles. We also show that the experimental examinations, in conjunction with doping-process simulations, allow examinations of how dopant distribution, such as junction depth and abruptness, affect the potential distribution in planar-bulk MOSFETs approaching the scaling limit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hydrogen Bonding in Proteins and Water Studied by Far-IR and Low-Wavenumber Raman Spectroscopy

Far-IR spectra with a synchrotron radiation source were for the first time recorded through a microscope coupled to an FTIR-spectrometer. A comparison with spectra recorded with an ordinary globar source revealed that no artifacts occurred with synchrotron radiation. A comparison of ATR (Si-prism) and transmission spectra of a tetrapeptide showed that the ATR-microscope technique could be applied. ATR- and transmission spectra were recorded of polyglycine and compared to the low wavenumber Raman spectrum in the R(v)-representation. A protein band at 115-125 cm{sup -1} was assigned to hydrogen bond modes. Collectively these modes might drive conformational changes in proteins. Based mainly on previously published results the determination of water with a structure like that in bulk liquid water was performed for human and animal skin samples. Changes in water content were reported for freezing and thawing of human skin biopsies and for human skin with benign or malignant skin diseases.

60 APPLIED LIFE SCIENCES↗

Scanning hard x-ray differential phase contrast imaging with a double wedge absorber

Two-directional differential phase contrast images were measured using an x-ray microbeam and a double wedge absorber. The wedge absorber converts the displacement of an x-ray beam that is refracted by an object into change of x-ray intensity. The double wedge absorber made it possible to detect values of two-directional refraction angle with {mu}rad sensitivity simultaneously. By Fourier integration of two-directional phase gradients calculated from the refraction angle instead of line integration of one-directional phase gradients, we obtained a quantitative phase map without artifacts even when only a part of the boundaries of the object were in the field of view. One of the characteristics of this technique is flexibility in a sensitivity of the phase gradient. By changing of shape or material of the wedge absorber, it is comparatively easy to control the detection limit of the refraction angle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of ruthenium dyes for subnanosecond detector fidelity testing in real time transient absorption

Transient absorption spectroscopy is a powerful tool for the study of photoreactions on time scales from femtoseconds to seconds. Typically, reactions slower than {approx}1 ns are recorded by the ''classical'' technique; the reaction is triggered by an excitation flash, and absorption changes accompanying the reaction are recorded in real time using a continuous monitoring light beam and a detection system with sufficiently fast response. The pico- and femtosecond region can be accessed by the more recent ''pump-probe'' technique, which circumvents the difficulties of real time detection on a subnanosecond time scale. This is paid for by accumulation of an excessively large number of shots to sample the reaction kinetics. Hence, it is of interest to extend the classical real time technique as far as possible to the subnanosecond range. In order to identify and minimize detection artifacts common on a subnanosecond scale, like overshoot, ringing, and signal reflections, rigorous testing is required of how the detection system responds to fast changes of the monitoring light intensity. Here, we introduce a novel method to create standard signals for detector fidelity testing on a time scale from a few picoseconds to tens of nanoseconds. The signals result from polarized measurements of absorption changes upon excitation of ruthenium complexes {l_brace}[Ru(bpy){sub 3}]{sup 2+} and a less symmetric derivative{r_brace} by a short laser flash. Two types of signals can be created depending on the polarization of the monitoring light with respect to that of the excitation flash: a fast steplike bleaching at magic angle and a monoexponentially decaying bleaching for parallel polarizations. The lifetime of the decay can be easily varied via temperature and viscosity of the solvent. The method is applied to test the performance of a newly developed real time transient absorption setup with 300 ps time resolution and high sensitivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗