Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ABLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

First beryllium capsule implosions on the National Ignition Facility

The first indirect drive implosion experiments using Beryllium (Be) capsules at the National Ignition Facility confirm the superior ablation properties and elucidate possible Be-ablator issues such as hohlraum filling by ablator material. Since the 1990s, Be has been the preferred Inertial Confinement Fusion (ICF) ablator because of its higher mass ablation rate compared to that of carbon-based ablators. This enables ICF target designs with higher implosion velocities at lower radiation temperatures and improved hydrodynamic stability through greater ablative stabilization. Recent experiments to demonstrate the viability of Be ablator target designs measured the backscattered laser energy, capsule implosion velocity, core implosion shape from self-emission, and in-flight capsule shape from backlit imaging. The laser backscatter is similar to that from comparable plastic (CH) targets under the same hohlraum conditions. Implosion velocity measurements from backlit streaked radiography show that laser energy coupling to the hohlraum wall is comparable to plastic ablators. The measured implosion shape indicates no significant reduction of laser energy from the inner laser cone beams reaching the hohlraum wall as compared with plastic and high-density carbon ablators. These results indicate that the high mass ablation rate for beryllium capsules does not significantly alter hohlraum energetics. In addition, these data, together with data for low fill-density hohlraum performance, indicate that laser power multipliers, required to reconcile simulations with experimental observations, are likely due to our limited understanding of the hohlraum rather than the capsule physics since similar multipliers are needed for both Be and CH capsules as seen in experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Isolating and quantifying cross-beam energy transfer in direct-drive implosions on OMEGA and the National Ignition Facility

The angularly resolved mass ablation rates and ablation-front trajectories for Si-coated CH targets were measured in direct-drive inertial confinement fusion experiments to quantify cross-beam energy transfer (CBET) while constraining the hydrodynamic coupling. A polar-direct-drive laser configuration, where the equatorial laser beams were dropped and the polar beams were repointed from a symmetric direct-drive configuration, was used to limit CBET at the pole while allowing it to persist at the equator. The combination of low- and high-CBET conditions observed in the same implosion allowed for the effects of CBET on the ablation rate and ablation pressure to be determined. Hydrodynamic simulations performed without CBET agreed with the measured ablation rate and ablation-front trajectory at the pole of the target, confirming that the CBET effects on the pole are small. The simulated mass ablation rates and ablation-front trajectories were in excellent agreement with the measurements at all angles when a CBET model based on Randall's equations [C. J. Randall et al., Phys. Fluids 24, 1474 (1981)] was included into the simulations with a multiplier on the CBET gain factor. These measurements were performed on OMEGA and at the National Ignition Facility to access a wide range of plasma conditions, laser intensities, and laser beam geometries. The presence of the CBET gain multiplier required to match the data in all of the configurations tested suggests that additional physics effects, such as intensity variations caused by diffraction, polarization effects, or shortcomings of extending the 1-D Randall model to 3-D, should be explored to explain the differences in observed and predicted drive.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The role of ambient gas confinement, plasma chemistry, and focusing conditions on emission features of femtosecond laser-produced plasmas

Ultrafast laser ablation coupled with optical emission spectroscopy is currently under development for standoff detection of elements and their isotopes for a wide range of application areas. In this work, we explore the role of ambient air pressure during the interaction of an ultrafast laser beam with two metallic targets (brass and uranium) with significantly different oxygen gas-phase reactivity. Plasma plumes were generated by focusing ~800 nm, ~35 fs pulses from an ultrafast laser system using a long focal length lens with f = 1 m. Two-dimensional spectral imaging was performed over the pressure range of 30 mTorr-700 Torr air to evaluate emission dynamics, plasma chemistry, signal-to-background ratio, and characteristic parameters (i.e. excitation temperature, electron density). An increase in ambient air pressure during ultrafast laser ablation leads to plume confinement and subsequent changes in the emission dynamics due to plasma chemistry as well as changes in plasma generation conditions (i.e. focused fs laser ablation versus filament ablation). Ablation crater morphologies were also investigated via scanning electron microscopy. Results indicate atomic emission intensity and signal-to-background ratios peak at moderate pressure levels (~50-100 Torr air) for both targets studied, although plasma chemistry influences uranium emission signatures. The emission features of the uranium plasma at pressures = 10 Torr showed the presence of atoms and oxide molecules which are co-located within the plume. We also find filament ablation leads to wider, more shallow craters compared to focused laser ablation. Our study provides unique insight into the interplay between plume dynamics, confinement, and oxygen chemistry of fs laser-produced plasmas and how these phenomena evolve with changing ambient air pressure.

Laser-produced plasma↗

Numerical studies of the effects of precursor plasma on the performance of wire-array Z-pinches

This paper is to numerically investigate, in one dimension, the effects of precursor plasma resulted from wire-array ablation on the performance of its following implosion after the ablation. The wire-array ablation is described by an analytic model, which consists of a rocket model or Sasorov's expression of wire-array mass ablation rate, the evolution equation of magnetic field, and several roughly reasonable assumptions. The following implosion is governed by the radiation magnetohydrodynamics. The implosion processes of wire-array Z-pinch from plasma shells prefilled and un-prefilled by the low-density plasma inside them are studied, and that from the wire-array ablations, which may be changed through varying the ablation time, ablation rate, and ablation velocity V{sub abl}, are also simulated. The obtained results reveal that the prefilled low-density plasma and the precursor plasma from the wire-array ablation help to enhance the plasma shell pinch and the final implosion of the wire array, respectively, compared to the pinch of un-prefilled plasma shell. With the same plasma masses, which are distributed in the interior of the array and the shell, and modified Spitzer resistivity, the implosions that start from the wire ablation develop faster than that from the plasma shell with the prefill. If more substance ablates from the wire array before the start of its implosion, the final Z-pinch performance could be better. The Z-pinch plasma is highly magnetized with driven current more than 3 MA.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Aerosol-Assisted Solid Debris Collection for the National Ignition Facility

The National Ignition Facility (NIF) has been completed and has made its first shots on-target. While upcoming experiments will be focused on achieving ignition, a variety of subsequent experiments are planned for the facility, including measurement of cross sections, astrophysical measurements, and investigation of hydrodynamic instability in the target capsule. In order to successfully execute several of these planned experiments, the ability to collect solid debris following a NIF capsule shot will be required. The ability to collect and analyze solid debris generated in a shot at the National Ignition Facility (NIF) will greatly expand the number of nuclear reactions studied for diagnostic purposes. Currently, reactions are limited to only those producing noble gases for cryogenic collection and counting with the Radchem Apparatus for Gas Sampling (RAGS). The radchem solid collection diagnostic has already been identified by NIF to be valuable for the determination and understanding of mix generated in the target capsule's ablation. LLNL is currently developing this solid debris collection capability at NIF, and is in the stage of testing credible designs. Some of these designs explore the use of x-ray generated aerosols to assist in collection of solid debris. However, the variety of harsh experimental conditions this solid collection device will encounter in NIF are challenging to replicate. Experiments performed by Gary Grim et al. at Sandia National Laboratory's RHEPP1 facility have shown that ablation causes a cloud of material removed from an exposed surface to move normal to and away from the surface. This ablation is certain to be a concern in the NIF target chamber from the prompt x-rays, gamma rays, etc. generated in the shot. The cloud of ablated material could interfere with the collection of the desired reaction debris by slowing down the debris so that the kinetic energy is too low to allow implantation, or by stopping the debris from reaching the collection device entirely. Our goal is to use this primary ablation wave to our advantage, by the creation of ionized alkali metal halide salt aerosols. This technique is similar to that used by many particle accelerator groups for gas-jet transport. Ideally the salt would be ablated from a substrate, encounter the reaction debris, agglomerate, and be collected for further study. We have done studies at laser and pulsed-power facilities (Titan laser at LLNL, Trident laser at LANL, Zebra z-pinch at Nevada Terawatt Facility) evaluating the hardiness of materials for placement in the NIF target chamber, as well as testing aerosol generation by the incident x-rays generated in device shots. To test this method's potential success in the NIF environment, we have tested KCl, KI, RbI, and CsI films of 1 and 2 um linear thickness on aluminum and silicon wafer substrates in these aforementioned facilities, at varied distances. These salts do ablate in the presence of sufficient x-ray fluence. Further analysis to quantify the final ablation depth as a function of x-ray fluence is ongoing. Half of each sample was masked with a thick tungsten foil for photon opacity. KCl was the most difficult salt to ablate, from comparing the tungsten-masked side of the samples to the unmasked side of the samples. This is likely due to KCl's absorbance peak being at lower wavelengths than that of KI, {approx}160 nm vs. {approx}220 nm, respectively. Samples with and without collimation were tested to identify if any condensation of these ablated salts occurred after ablation. Visual inspection of the silicon wafer witness plates placed parallel to the direction of the incident photons showed that a vapor was deposited on the wafers next to the collimators. Further analysis with EDS in the case of the collimated samples conclusively identified the vapor as CsI. We also intend to examine samples of bare substrate exposed to the same experimental conditions for post-shot change via SEM images, optical microscopy, and atomic force microscopy (AFM). Furthermore, tests with separated isotopes may be done to reduce background contamination. When sample optimization is complete, we plan to develop a 'catcher' device for these desorbed aerosols. Current ideas include biased grids to either attract the ionized particles to the grid, or repel them towards a collection device.

36 MATERIALS SCIENCE↗

Adiabat-shaping in indirect drive inertial confinement fusion

Adiabat-shaping techniques were investigated in indirect drive inertial confinement fusion experiments on the National Ignition Facility as a means to improve implosion stability, while still maintaining a low adiabat in the fuel. Adiabat-shaping was accomplished in these indirect drive experiments by altering the ratio of the picket and trough energies in the laser pulse shape, thus driving a decaying first shock in the ablator. This decaying first shock is designed to place the ablation front on a high adiabat while keeping the fuel on a low adiabat. These experiments were conducted using the keyhole experimental platform for both three and four shock laser pulses. This platform enabled direct measurement of the shock velocities driven in the glow-discharge polymer capsule and in the liquid deuterium, the surrogate fuel for a DT ignition target. The measured shock velocities and radiation drive histories are compared to previous three and four shock laser pulses. This comparison indicates that in the case of adiabat shaping the ablation front initially drives a high shock velocity, and therefore, a high shock pressure and adiabat. The shock then decays as it travels through the ablator to pressures similar to the original low-adiabat pulses when it reaches the fuel. This approach takes advantage of initial high ablation velocity, which favors stability, and high-compression, which favors high stagnation pressures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First Delayed Resection Findings After Irreversible Electroporation (IRE) of Human Localised Renal Cell Carcinoma (RCC) in the IRENE Pilot Phase 2a Trial

IntroductionIt is postulated that focal IRE affords complete ablation of soft-tissue tumours while protecting the healthy peritumoral tissue. Therefore, IRE may be an interesting option for minimally invasive, kidney-tissue-sparing, non-thermal ablation of renal tumours.AimWith this current pilot study (“IRENE trial”), we present the first detailed histopathological data of IRE of human RCC followed by delayed tumour resection. The aim of this interim analysis of the first three patients was to investigate the ablation efficiency of percutaneous image-guided focal IRE in RCC, to assess whether a complete ablation of T1a RCC and tissue preservation with the NanoKnife system is possible and to decide whether the ablation parameters need to be altered.MethodsFollowing resection 4 weeks after percutaneous IRE, the success of ablation and detailed histopathological description were used to check the ablation parameters.ResultsThe IRE led to a high degree of damage to the renal tumours (1 central, 2 peripheral; size range 15–17 mm). The postulated homogeneous, isomorphic damage was only partly confirmed. We found a zonal structuring of the ablation zone, negative margins and, enclosed within the ablation zone, very small tumour residues of unclear malignancy.ConclusionAccording to these initial, preliminary study results of the first three renal cases, a new zonal distribution of IRE damage was described and the curative intended, renal saving focal ablation of localised RCC below <3 cm by percutaneous IRE by the NanoKnife system appears to be possible, but needs further, systematic evaluation for this treatment method and treatment protocol.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Implosion dynamics measurements at the National Ignition Facility

Measurements have been made of the in-flight dynamics of imploding capsules indirectly driven by laser energies of 1-1.7 MJ at the National Ignition Facility [Miller et al., Nucl. Fusion 44, 228 (2004)]. These experiments were part of the National Ignition Campaign [Landen et al., Phys. Plasmas 18, 051002 (2011)] to iteratively optimize the inputs required to achieve thermonuclear ignition in the laboratory. Using gated or streaked hard x-ray radiography, a suite of ablator performance parameters, including the time-resolved radius, velocity, mass, and thickness, have been determined throughout the acceleration history of surrogate gas-filled implosions. These measurements have been used to establish a dynamically consistent model of the ablative drive history and shell compressibility throughout the implosion trajectory. First results showed that the peak velocity of the original 1.3-MJ Ge-doped polymer (CH) point design using Au hohlraums reached only 75% of the required ignition velocity. Several capsule, hohlraum, and laser pulse changes were then implemented to improve this and other aspects of implosion performance and a dedicated effort was undertaken to test the sensitivity of the ablative drive to the rise time and length of the main laser pulse. Changing to Si rather than Ge-doped inner ablator layers and increasing the pulse length together raised peak velocity to 93% {+-} 5% of the ignition goal using a 1.5 MJ, 420 TW pulse. Further lengthening the pulse so that the laser remained on until the capsule reached 30% (rather than 60%-70%) of its initial radius, reduced the shell thickness and improved the final fuel {rho}R on companion shots with a cryogenic hydrogen fuel layer. Improved drive efficiency was observed using U rather than Au hohlraums, which was expected, and by slowing the rise time of laser pulse, which was not. The effect of changing the Si-dopant concentration and distribution, as well as the effect of using a larger initial shell thickness were also examined, both of which indicated that instabilities seeded at the ablation front are a significant source of hydrodynamic mix into the central hot spot. Additionally, a direct test of the surrogacy of cryogenic fuel layered versus gas-filled targets was performed. Together all these measurements have established the fundamental ablative-rocket relationship describing the dependence of implosion velocity on fractional ablator mass remaining. This curve shows a lower-than-expected ablator mass at a given velocity, making the capsule more susceptible to feedthrough of instabilities from the ablation front into the fuel and hot spot. This combination of low velocity and low ablator mass indicates that reaching ignition on the NIF will require >20 {mu}m ({approx}10%) thicker targets and laser powers at or beyond facility limits.

36 MATERIALS SCIENCE↗

BNNT-mediated irreversible electroporatio: its potential on cancer cells

Tissue ablation, i.e., the destruction of undesirable tissues, has become an important minimally invasive technique alternative to resection surgery for the treatment of tumours. Several methods for tissue ablation are based on thermal techniques using cold, e.g. cryosurgery [1] or heat, e.g. radiofrequency [2] or high-intensity focused ultrasound [3] or nanoparticle-mediated irradiation [4]. Alternatively, irreversible electroporation (IRE) has been proposed as non thermal technique for minimally invasive tissue ablation based on the use of electrical pulses. When the electric field is applied to a cell, a change in transmembrane potential is induced, which can cause biochemical and physiological changes of the cell. When the threshold value of the transmembrane potential is exceeded, the cell membrane becomes permeable, thus allowing entrance of molecules that otherwise cannot cross the membrane [5]. A further increase in the electric field intensity may cause irreversible membrane permeabilization and cell death. These pulses create irreversible defects (pores) in the cell membrane lipid bilayer, causing cell death through loss of cell homeostasis [6]. This is desirable in tumour ablation in order to produce large cell death, without the use of cytostatic drugs. A study of Davalos, Mir and Rubinsky showed that IRE can ablate substantial volumes of tissue without inducing a thermal effect and therefore serve as an independent and new tissue ablation modality; this opened the way to the use of IRE in surgery [7]. Their finding was subsequently confirmed in studies on cells [8], small animal models [9] and in large animal models in the liver [10] and the heart [11]. The most important finding in these papers is that irreversible electroporation produces precisely delineated ablation zones with cell scale resolution between ablated and non-ablated areas, without zones in which the extent of damage changes gradually as during thermal ablation. Furthermore, it is observed that irreversible electroporation affects only the membrane of living cells and spares the tissues scaffold. The work of Rubinsky et al.[10] was the first to highlight some of the essential clinical features of irreversible electroporation such as the ability to spare large blood vessels and bile ducts, rapid tissue regeneration because of the intact large blood vessels scaffolds, rapid activation of the immune system, no scarring and the potential ability to treat tumours near large blood vessels [12] .

60 APPLIED LIFE SCIENCES↗

Hot-spot mix in ignition-scale implosions on the NIF

Ignition of an inertial confinement fusion (ICF) target depends on the formation of a central hot spot with sufficient temperature and areal density. Radiative and conductive losses from the hot spot can be enhanced by hydrodynamic instabilities. The concentric spherical layers of current National Ignition Facility (NIF) ignition targets consist of a plastic ablator surrounding a thin shell of cryogenic thermonuclear fuel (i.e., hydrogen isotopes), with fuel vapor filling the interior volume [S. W. Haan et al., Phys. Plasmas 18, 051001 (2011)]. The Rev. 5 ablator is doped with Ge to minimize preheat of the ablator closest to the DT ice caused by Au M-band emission from the hohlraum x-ray drive [D. S. Clark et al., Phys. Plasmas 17, 052703 (2010)]. Richtmyer-Meshkov and Rayleigh-Taylor hydrodynamic instabilities seeded by high-mode () ablator-surface perturbations can cause Ge-doped ablator to mix into the interior of the shell at the end of the acceleration phase [B. A. Hammel et al., Phys. Plasmas 18, 056310 (2011)]. As the shell decelerates, it compresses the fuel vapor, forming a hot spot. K-shell line emission from the ionized Ge that has penetrated into the hot spot provides an experimental signature of hot-spot mix. The Ge emission from tritium-hydrogen-deuterium (THD) and deuterium-tritium (DT) cryogenic targets and gas-filled plastic-shell capsules, which replace the THD layer with a mass-equivalent CH layer, was examined. The inferred amount of hot-spot-mix mass, estimated from the Ge K-shell line brightness using a detailed atomic physics code [J. J. MacFarlane et al., High Energy Density Phys. 3, 181 (2006)], is typically below the 75-ng allowance for hot-spot mix [S. W. Haan et al., Phys. Plasmas 18, 051001 (2011)]. Predictions of a simple mix model, based on linear growth of the measured surface-mass modulations, are consistent with the experimental results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Histopomorphic Evaluation of Radiofrequency Mediated Débridement Chondroplasty

The use of radiofrequency devices has become widespread for surgical ablation procedures. When ablation devices have been deployed in treatment settings requiring tissue preservation like débridement chondroplasty, adoption has been limited due to the collateral damage caused by these devices in healthy tissue surrounding the treatment site. Ex vivo radiofrequency mediated débridement chondroplasty was performed on osteochondral specimens demonstrating surface fibrillation obtained from patients undergoing knee total joint replacement. Three radiofrequency systems designed to perform débridement chondroplasty were tested each demonstrating different energy delivery methods: monopolar ablation, bipolar ablation, and non-ablation energy. Treatment outcomes were compared with control specimens as to clinical endpoint and histopomorphic characteristics. Fibrillated cartilage was removed in all specimens; however, the residual tissue remaining at the treatment site displayed significantly different characteristics attributable to radiofrequency energy delivery method. Systems that delivered ablation-based energies caused tissue necrosis and collateral damage at the treatment site including corruption of cartilage Superficial and Transitional Zones; whereas, the non-ablation system created a smooth articular surface with Superficial Zone maintenance and without chondrocyte death or tissue necrosis. The mechanism of radiofrequency energy deposition upon tissues is particularly important in treatment settings requiring tissue preservation. Ablation-based device systems can cause a worsened state of articular cartilage from that of pre-treatment. Non-ablation energy can be successful in modifying/preconditioning tissue during débridement chondroplasty without causing collateral damage. Utilizing a non-ablation radiofrequency system provides the ability to perform successful débridement chondroplasty without causing additional articular cartilage tissue damage and may allow for other cartilage intervention success.

59 BASIC BIOLOGICAL SCIENCES↗

Atomistic simulation of laser-pulse surface modification: Predictions of models with various length and time scales

In this work, the femtosecond laser pulse modification of surface is studied for aluminium (Al) and gold (Au) by use of two-temperature atomistic simulation. The results are obtained for various atomistic models with different scales: from pseudo-one-dimensional to full-scale three-dimensional simulation. The surface modification after laser irradiation can be caused by ablation and melting. For low energy laser pulses, the nanoscale ripples may be induced on a surface by melting without laser ablation. In this case, nanoscale changes of the surface are due to a splash of molten metal under temperature gradient. Laser ablation occurs at a higher pulse energy when a crater is formed on the surface. There are essential differences between Al ablation and Au ablation. In the first step of shock-wave induced ablation, swelling and void formation occur for both metals. However, the simulation of ablation in gold shows an additional athermal type of ablation that is associated with electron pressure relaxation. This type of ablation takes place at the surface layer, at a depth of several nanometers, and does not induce swelling.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Implosion Dynamics in Direct-Drive Experiments

Increasing the ablation pressure is a path to achieving cryogenic implosion performance on the OMEGA laser that will hydrodynamically scale to ignition on the National Ignition Facility. An increased ablation pressure will allow a more-massive shell (i.e. thicker and more hydrodynamically stable) and a higher adiabat to achieve ignition-relevant velocities (>3.5 × 10⁷ cm s⁻¹), areal densities (>300 mg cm⁻²) and hot-spot pressures (>100 Gbar). Two approaches have demonstrated increased ablation pressure: (1) a target design is shown that uses a Be ablator to increase the hydrodynamic efficiency, resulting in a ~10% increase in the ablation pressure, in comparison to a CH ablator; (2) reducing the beam size is shown to recover all of the ablation pressure lost to cross-beam energy transfer (CBET), i.e. the ablation pressure calculated without CBET, but the degraded illumination uniformity reduces the integrated target performance. The hydrodynamic efficiency is measured for the current cryogenic design, multiple ablator material design and CH capsule designs with various beam focal-spot sizes. In each case, an excellent agreement is observed with 1D hydrodynamic simulations that include CBET and nonlocal heat-transport models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Expansion dynamics and chemistry evolution in ultrafast laser filament produced plasmas

Laser ablation in conjunction with optical emission spectroscopy is a potential non-contact, standoff detection method for all elements in the periodic table and certain isotopes such as radionuclides. Currently, significant development efforts are on-going to use ultrafast laser filaments for remote sensing. The application of filaments is of particular interest in extending the range of stand-off capability associated with elemental and isotopic detection via laser-induced breakdown spectroscopy. In this study, we characterize the expansion dynamics and chemical evolution of filament-produced uranium (U) plasmas. Laser filaments are generated in the laboratory by loosely focusing 35 femtosecond (fs), 6 milli Joule (mJ) pulses in air. Two-dimensional spectrally-integrated and time-resolved imaging was performed to study hydrodynamics and evolution of U atomic and UO molecular emission in filament-produced U plasmas. Our results highlight that filament ablation of U plasmas gives a cylindrical plasma plume morphology with an appearance of plume splitting into slow and fast moving components at later times of its evolution. Emission from the slow-moving region shows no distinct spectral features (i.e. broadband-like) and is contributed in part by nanoparticles generated during ultrafast laser ablation. Additionally, we find U atoms and U oxide molecules (i.e. UO, UxOy) co-exist in the filament produced plasma, which can be attributed to the generation of low-temperature plasma conditions during filament ablation

(140.3440) Laser-induced breakdown, (280.5395) Pla↗