Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “visualization algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Global 3D Data Visualization and Analysis Platform with Advanced Machine Learning Capabilities in Support of Lunar Exploration

Introduction: The science goals for NASA’s Artemis program include: a) Understanding the character and origin of lunar polar volatiles, b) Conducting experimental science in the lunar environment and c) Investigating and mitigating exploration risks. The permanently shadowed regions (PSRs) on the Lunar south pole are expected to host large quantities of water-ice and volatiles that are important for sustainable Lunar exploration. There are several missions such as onboard Korea Pathfinder Lunar Orbiter (KPLO: Korean name Danuri) with onboard ShadowCam camera, Astrobotic Peregrine Mission One [4], and other efforts underway to obtain high resolution topographic, minerals, volatiles and other information on the moon. We envision a need in immediate future for platforms to integrate these data sets, provide rendering and visualization capabilities in the context of a 3D Lunar globe for easier information access and analysis. NASA's Celestial Mapping System (CMS) is developed to address the need for 3D tools for planetary science investigations, mission planning, in-situ operations, in a 3D-first design constructed around a unified view of a planetary globe. At present CMS provides many critical functionalities that include: 1) equipment planning and optimized placement on Lunar surface 2) line-of-sight (LOS) analysis 3) powerful measurement tools based on 3D terrain with realistic 3D models to represent rovers, astronauts and equipment 4) visualization of derived mapping products (e.g. resource maps), and 5) a data engine for hosting new observations that are not available in other contemporary lunar data tools. Planetary Data Ingestion: CMS can consume and analyze data from locally hosted and external third party sources. It is compatible with Open Geospatial Consortium (OGC) data and file standards and currently integrates datasets from the Astrogeology Science Center of USGS. This includes global and local data acquired from NASA (LRO, Clementine, Lunar Orbiter) and JAXA (SELENE/Kaguya), with capability of integrating more datasets. In addition, users can specify other WMS-hosted data endpoints, which CMS can then query and stream data from automatically. To set-up an automated process for ingestion and accurate rendering, visualization and analysis of external 3rd party planetary datasets within CMS, we initiated the process of ingesting unique dataset of super-enhanced images of the permanently shadowed regions (PSRs) at the lunar poles which were produced by the Hyper-effective nOise Removal U-net Software (HORUS) tool. This tool was developed to enhance the extremely low-light images of the interior of PSRs and provide the ability to see within these regions at and discern surface features (i.e. boulders and craters) down to 3 meters in size. We focused on the Nobile region on the Lunar south pole, selected site for VIPER mission and stitched several images to create a high-resolution map within one of the PSR of Nobile crater. Figure 1 shows the dark PSR zone form the original NAC layer of LRO as the base layer (left image) and the illuminated areas within that crater (center) which was created by ingesting and merging several of HORUS generated images. At present we employ a semi-automated process to ensure spatial accuracy and merger of several overlapping zones. However, we are in the process of completely automating this process by employing AI based techniques that would rank, sort, and stack the images based on their information density. The georectification of the images would employ selected features. Analysis on Ingested Planetary Datasets: Once an external planetary data-set is successfully ingested, georectified and merged seamlessly as a data-layer; CMS’ numerous analysis tools can be used on this data. A Line of Sight (LOS) tool has been developed for CMS which analyzes terrain profiles and obstructions to determine visibility for remote observers. Figure 1 (right image) shows the viewshed analysis on the same PSR in the Nobile region. The yellow pin shows the observer location outside the PSR. The yellow area shows the visible part of PSR. The obstructed area with no visibility for the observer is shown in red. The Measurements tool allows the user to take area and distance measurements of features on the terrain using various shapes. Measurement type can be specified in a number of ways: Line, Path, Polygon, Circle, Ellipse, Square, Rectangle or Freehand. Once the shape is specified, elevation information can then be extracted along each of these shapes. Figure 2 (left) shows the measurements performed on a crater n illuminated PSR in Nobile region. The equipment placement tool allows the user to place a 3D equipment model at a desired location and analyze its coverage area. The equipment placement tool is coupled with LOS to determine the coverage. Figure 2 (right) shows an equipment placed on the Lunar terrain and it’s coverage area. The red rays are blocked sight lines and the green rays are non-obstructed sight lines with the cyan lines showing the point of intersection with the terrain. More details are provided in the video demonstrations in Reference 5. Overcoming Polar Distortions: 3D geospatial applications exhibit significant distortions in polar imagery due to several reasons: 1) distortions in the source imagery, 2) incompatible tessellation algorithms at the poles, and 3) map projections. We are leveraging new tessellation algorithms and reprojecting data using projections that are better suited for Lunar poles. The goal is to seamlessly switch to polar projections while maintaining 3D view and navigation.

Maps↗

Evaluation of normalized metal artifact reduction (NMAR) in kVCT using MVCT prior images for radiotherapy treatment planning

Purpose: To evaluate the metal artifacts in kilovoltage computed tomography (kVCT) images that are corrected using a normalized metal artifact reduction (NMAR) method with megavoltage CT (MVCT) prior images.Methods: Tissue characterization phantoms containing bilateral steel inserts are used in all experiments. Two MVCT images, one without any metal artifact corrections and the other corrected using a modified iterative maximum likelihood polychromatic algorithm for CT (IMPACT) are translated to pseudo-kVCT images. These are then used as prior images without tissue classification in an NMAR technique for correcting the experimental kVCT image. The IMPACT method in MVCT included an additional model for the pair/triplet production process and the energy dependent response of the MVCT detectors. An experimental kVCT image, without the metal inserts and reconstructed using the filtered back projection (FBP) method, is artificially patched with the known steel inserts to get a reference image. The regular NMAR image containing the steel inserts that uses tissue classified kVCT prior and the NMAR images reconstructed using MVCT priors are compared with the reference image for metal artifact reduction. The Eclipse treatment planning system is used to calculate radiotherapy dose distributions on the corrected images and on the reference image using the Anisotropic Analytical Algorithm with 6 MV parallel opposed 5 × 10 cm{sup 2} fields passing through the bilateral steel inserts, and the results are compared. Gafchromic film is used to measure the actual dose delivered in a plane perpendicular to the beams at the isocenter.Results: The streaking and shading in the NMAR image using tissue classifications are significantly reduced. However, the structures, including metal, are deformed. Some uniform regions appear to have eroded from one side. There is a large variation of attenuation values inside the metal inserts. Similar results are seen in commercially corrected image. Use of MVCT prior images without tissue classification in NMAR significantly reduces these problems. The radiation dose calculated on the reference image is close to the dose measured using the film. Compared to the reference image, the calculated dose difference in the conventional NMAR image, the corrected images using uncorrected MVCT image, and IMPACT corrected MVCT image as priors is ∼15.5%, ∼5%, and ∼2.7%, respectively, at the isocenter.Conclusions: The deformation and erosion of the structures present in regular NMAR corrected images can be largely reduced by using MVCT priors without tissue segmentation. The attenuation value of metal being incorrect, large dose differences relative to the true value can result when using the conventional NMAR image. This difference can be significantly reduced if MVCT images are used as priors. Reduced tissue deformation, better tissue visualization, and correct information about the electron density of the tissues and metals in the artifact corrected images could help delineate the structures better, as well as calculate radiation dose more correctly, thus enhancing the quality of the radiotherapy treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Constrained CVT meshes and a comparison of triangular mesh generators

Mesh generation in regions in Euclidean space is a central task in computational science, and especially for commonly used numerical methods for the solution of partial differential equations, e.g., finite element and finite volume methods. We focus on the uniform Delaunay triangulation of planar regions and, in particular, on how one selects the positions of the vertices of the triangulation. We discuss a recently developed method, based on the centroidal Voronoi tessellation (CVT) concept, for effecting such triangulations and present two algorithms, including one new one, for CVT-based grid generation. We also compare several methods, including CVT-based methods, for triangulating planar domains. To this end, we define several quantitative measures of the quality of uniform grids. We then generate triangulations of several planar regions, including some having complexities that are representative of what one may encounter in practice. We subject the resulting grids to visual and quantitative comparisons and conclude that all the methods considered produce high-quality uniform grids and that the CVT-based grids are at least as good as any of the others.

97 MATHEMATICS AND COMPUTING↗

Cost - The challenge for advanced materials and structures

Information is presented on the cost of various aircraft structures, together with methods for predicting and reducing cost. The need for the development of cost models, and of a comparative cost algorithm which could function as an engineering design tool to evaluate different design concepts, is emphasized. Efforts are underway to develop cost models that establish building-block unit cell elements that represent different material forms, geometric shapes, fabrication processes, and methods of assembly, with the purpose of expressing cost per pound or labor per pound data, with physical design and manufacture variables that a designer can visualize.

Davis, John G., Jr.↗

Application of Least-Squares Adjustment Technique to Geometric Camera Calibration and Photogrammetric Flow Visualization

Flow visualization produces data in the form of two-dimensional images. If the optical components of a camera system are perfect, the transformation equations between the two-dimensional image and the three-dimensional object space are linear and easy to solve. However, real camera lenses introduce nonlinear distortions that affect the accuracy of transformation unless proper corrections are applied. An iterative least-squares adjustment algorithm is developed to solve the nonlinear transformation equations incorporated with distortion corrections. Experimental applications demonstrate that a relative precision on the order of 40,000 is achievable without tedious laboratory calibrations of the camera.

Chen, Fang-Jenq↗

Molecular radiotherapy: The NUKFIT software for calculating the time-integrated activity coefficient

Purpose: Calculation of the time-integrated activity coefficient (residence time) is a crucial step in dosimetry for molecular radiotherapy. However, available software is deficient in that it is either not tailored for the use in molecular radiotherapy and/or does not include all required estimation methods. The aim of this work was therefore the development and programming of an algorithm which allows for an objective and reproducible determination of the time-integrated activity coefficient and its standard error.Methods: The algorithm includes the selection of a set of fitting functions from predefined sums of exponentials and the choice of an error model for the used data. To estimate the values of the adjustable parameters an objective function, depending on the data, the parameters of the error model, the fitting function and (if required and available) Bayesian information, is minimized. To increase reproducibility and user-friendliness the starting values are automatically determined using a combination of curve stripping and random search. Visual inspection, the coefficient of determination, the standard error of the fitted parameters, and the correlation matrix are provided to evaluate the quality of the fit. The functions which are most supported by the data are determined using the corrected Akaike information criterion. The time-integrated activity coefficient is estimated by analytically integrating the fitted functions. Its standard error is determined assuming Gaussian error propagation. The software was implemented using MATLAB.Results: To validate the proper implementation of the objective function and the fit functions, the results of NUKFIT and SAAM numerical, a commercially available software tool, were compared. The automatic search for starting values was successfully tested for reproducibility. The quality criteria applied in conjunction with the Akaike information criterion allowed the selection of suitable functions. Function fit parameters and their standard error estimated by using SAAM numerical and NUKFIT showed differences of <1%. The differences for the time-integrated activity coefficients were also <1% (standard error between 0.4% and 3%). In general, the application of the software is user-friendly and the results are mathematically correct and reproducible. An application of NUKFIT is presented for three different clinical examples.Conclusions: The software tool with its underlying methodology can be employed to objectively and reproducibly estimate the time integrated activity coefficient and its standard error for most time activity data in molecular radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

A GPU based high-resolution multilevel biomechanical head and neck model for validating deformable image registration

Purpose: Validating the usage of deformable image registration (DIR) for daily patient positioning is critical for adaptive radiotherapy (RT) applications pertaining to head and neck (HN) radiotherapy. The authors present a methodology for generating biomechanically realistic ground-truth data for validating DIR algorithms for HN anatomy by (a) developing a high-resolution deformable biomechanical HN model from a planning CT, (b) simulating deformations for a range of interfraction posture changes and physiological regression, and (c) generating subsequent CT images representing the deformed anatomy. Methods: The biomechanical model was developed using HN kVCT datasets and the corresponding structure contours. The voxels inside a given 3D contour boundary were clustered using a graphics processing unit (GPU) based algorithm that accounted for inconsistencies and gaps in the boundary to form a volumetric structure. While the bony anatomy was modeled as rigid body, the muscle and soft tissue structures were modeled as mass–spring-damper models with elastic material properties that corresponded to the underlying contoured anatomies. Within a given muscle structure, the voxels were classified using a uniform grid and a normalized mass was assigned to each voxel based on its Hounsfield number. The soft tissue deformation for a given skeletal actuation was performed using an implicit Euler integration with each iteration split into two substeps: one for the muscle structures and the other for the remaining soft tissues. Posture changes were simulated by articulating the skeletal structure and enabling the soft structures to deform accordingly. Physiological changes representing tumor regression were simulated by reducing the target volume and enabling the surrounding soft structures to deform accordingly. Finally, the authors also discuss a new approach to generate kVCT images representing the deformed anatomy that accounts for gaps and antialiasing artifacts that may be caused by the biomechanical deformation process. Accuracy and stability of the model response were validated using ground-truth simulations representing soft tissue behavior under local and global deformations. Numerical accuracy of the HN deformations was analyzed by applying nonrigid skeletal transformations acquired from interfraction kVCT images to the model’s skeletal structures and comparing the subsequent soft tissue deformations of the model with the clinical anatomy. Results: The GPU based framework enabled the model deformation to be performed at 60 frames/s, facilitating simulations of posture changes and physiological regressions at interactive speeds. The soft tissue response was accurate with a R{sup 2} value of >0.98 when compared to ground-truth global and local force deformation analysis. The deformation of the HN anatomy by the model agreed with the clinically observed deformations with an average correlation coefficient of 0.956. For a clinically relevant range of posture and physiological changes, the model deformations stabilized with an uncertainty of less than 0.01 mm. Conclusions: Documenting dose delivery for HN radiotherapy is essential accounting for posture and physiological changes. The biomechanical model discussed in this paper was able to deform in real-time, allowing interactive simulations and visualization of such changes. The model would allow patient specific validations of the DIR method and has the potential to be a significant aid in adaptive radiotherapy techniques.

60 APPLIED LIFE SCIENCES↗

Computational Biology for Drug Discovery and Characterization

We proposed to determine the underpinnings of a high-throughput computational infrastructure that would support future efforts in therapeutics against biothreat pathogens. Existing modeling capabilities focus on pathogen detection, but extending such capabilities to high-throughput molecular docking would lead to a proactive method to guide the development of therapeutics. This project will focus on determining the feasibility of extending current databases to accommodate molecular docking. We will also examine the feasibility of massive parallelization of docking algorithms and the utility of docking libraries. Transferring this new technique to a high-performance computing (HPC) platform at LLNL would result in a unique capability not available elsewhere in government or industry. We have accomplished the proposed work defined in this LDRD FS study. (1) We successfully defined the feasibility of using three different small-molecule databases for high-throughput docking, the NCI diversity set, ZINC and the ACD. (2) We analyzed the accuracy and parallelization capabilities of six separate docking programs: DOCK, AutoDock, FlexX, Glide, and eHiTS. Each program is completely amenable to parallel execution. The fastest code was eHiTS, and Glide was the most accurate. (3) Customizing large libraries was cumbersome without the proper software, making the databases a bit difficult to tailor. The ZINC database has some prefiltered versions. (4) Scripts were created for quality and job control functions. Further development is needed for analysis and visualization needs. The successful conclusion of this project enables LLNL to have a high-throughput computational docking capability where we have evaluated the codes to specific docking problems and utilized LLNL's HPC for significant gains in performance. We have established a CRADA with an industrial partner (funded by the National Institutes of Health) that will fully utilize this technology for biodefense therapeutic design and development.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accuracy of Routine Treatment Planning 4-Dimensional and Deep-Inspiration Breath-Hold Computed Tomography Delineation of the Left Anterior Descending Artery in Radiation Therapy

Purpose: To assess the feasibility of radiation therapy treatment planning 4-dimensional computed tomography (4DCT) and deep-inspiration breath-hold (DIBH) CT to accurately contour the left anterior descending artery (LAD), a primary indicator of radiation-induced cardiac toxicity for patients undergoing radiation therapy. Methods and Materials: Ten subjects were prospectively imaged with a cardiac-gated MRI protocol to determine cardiac motion effects, including the displacement of a region of interest comprising the LAD. A series of planar views were obtained and resampled to create a 3-dimensional (3D) volume. A 3D optical flow deformable image registration algorithm determined tissue displacement during the cardiac cycle. The measured motion was then used as a spatial boundary to characterize motion blurring of the radiologist-delineated LAD structure for a cohort of 10 consecutive patients enrolled prospectively on a breast study including 4DCT and DIBH scans. Coronary motion–induced blurring artifacts were quantified by applying an unsharp filter to accentuate the LAD structure despite the presence of motion blurring. The 4DCT maximum inhalation and exhalation respiratory phases were coregistered to determine the LAD displacement during tidal respiration, as visualized in 4DCT. Results: The average 90th percentile heart motion for the region of interest was 0.7 ± 0.1 mm (left–right [LR]), 1.3 ± 0.6 mm (superior–inferior [SI]), and 0.6 ± 0.2 mm (anterior–posterior [AP]) in the cardiac-gated MRI cohort. The average relative increase in the number of voxels comprising the LAD contour was 69.4% ± 4.5% for the DIBH. The LAD volume overestimation had the dosimetric impact of decreasing the reported mean LAD dose by 23% ± 9% on average in the DIBH. During tidal respiration the average relative LAD contour increase was 69.3% ± 5.9% and 67.9% ± 4.6% for inhalation and exhalation respiratory phases, respectively. The average 90th percentile LAD motion was 4.8 ± 1.1 mm (LR), 0.9 ± 0.4 mm (SI), and 1.9 ± 0.6 mm (AP) for the 4DCT cohort, in the absence of cardiac gating. Conclusions: An anisotropic margin of 2.7 mm (LR), 4.1 mm (SI), and 2.4 mm (AP) was quantitatively determined to account for motion blurring and patient setup error while placing minimum constraint on the plan optimization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Guided Text Analysis Using Adaptive Visual Analytics

This paper demonstrates the promise of augmenting interactive visualizations with semi-supervised machine learning techniques to improve the discovery of significant associations and insight in the search and analysis of textual information. More specifically, we have developed a system called Gryffin that hosts a unique collection of techniques that facilitate individualized investigative search pertaining to an ever-changing set of analytical questions over an indexed collection of open-source publications related to national infrastructure. The Gryffin client hosts dynamic displays of the search results via focus+context record listings, temporal timelines, term- frequency views, and multiple coordinated views. Furthermore, as the analyst interacts with the display, the interactions are recorded and used to label the search records. These labeled records are then used to drive semi-supervised machine learning algorithms that re-rank the unlabeled search records such that potentially relevant records are moved to the top of the record listing. Gryffin is described in the context of the daily tasks encountered at the Department of Homeland Securitys Fusion Centers, with whom we are collaborating in its development. The resulting system is capable of addressing the analysts information overload that can be directly attributed to the deluge of information that must be addressed in search and investigative analysis of textual information.

machine learning↗

Accelerated Depth Computation for Surface Boxplots with Deep Learning

Functional depth is a well-known technique used to derive descriptive statistics (e.g., median, quartiles, and outliers) for 1D data. Surface boxplots extend this concept to ensembles of images, helping scientists and users identify representative and outlier images. However, the computational time for surface boxplots increases cubically with the number of ensemble members, making it impractical for integration into visualization tools. In this paper, we propose a deep-learning solution for efficient depth prediction and computation of surface boxplots for time-varying ensemble data. Our deep learning framework accurately predicts member depths in a surface boxplot, achieving average speedups of 6X on a CPU and 15X on a GPU for the 2D Red Sea dataset with 50 ensemble members compared to the traditional depth computation algorithm. Our approach achieves at least a 99% level of rank preservation, with order flipping occurring only at pairs with extremely similar depth values that pose no statistical differences. This local flipping does not significantly impact the overall depth order of the ensemble members.

Han, Mengjiao↗

BinaRena: a dedicated interactive platform for human-guided exploration and binning of metagenomes

Background: Exploring metagenomic contigs and “binning” them into metagenome-assembled genomes (MAGs) are essential for the delineation of functional and evolutionary guilds within microbial communities. Despite the advances in automated binning algorithms, their capabilities in recovering MAGs with accuracy and biological relevance are so far limited. Researchers often find that human involvement is necessary to achieve representative binning results. This manual process however is expertise demanding and labor intensive, and it deserves to be supported by software infrastructure. Results: We present BinaRena, a comprehensive and versatile graphic interface dedicated to aiding human operators to explore metagenome assemblies via customizable visualization and to associate contigs with bins. Contigs are rendered as an interactive scatter plot based on various data types, including sequence metrics, coverage profiles, taxonomic assignments, and functional annotations. Various contig-level operations are permitted, such as selection, masking, highlighting, focusing, and searching. Binning plans can be conveniently edited, inspected, and compared visually or using metrics including silhouette coefficient and adjusted Rand index. Completeness and contamination of user-selected contigs can be calculated in real time. In demonstration of BinaRena’s usability, we show that it facilitated biological pattern discovery, hypothesis generation, and bin refinement in a complex tropical peatland metagenome. It enabled isolation of pathogenic genomes within closely related populations from the gut microbiota of diarrheal human subjects. It significantly improved overall binning quality after curating results of automated binners using a simulated marine dataset. Conclusions: BinaRena is an installation-free, dependency-free, client-end web application that operates directly in any modern web browser, facilitating ease of deployment and accessibility for researchers of all skill levels. The program is hosted at https://github.com/qiyunlab/binarena, together with documentation, tutorials, example data, and a live demo. It effectively supports human researchers in intuitive interpretation and fine tuning of metagenomic data.

59 BASIC BIOLOGICAL SCIENCES↗

Microreactor Automated Control System Test Bed Digital Architecture for Real-Time, Hardware-in-the-Loop Simulation

This work describes progress made towards the development of a real-time hardware-in-the-loop (HIL) test bed for non-nuclear testing of microreactor control schemes and failure modes. Non-nuclear testing is a crucial step in developing robust control algorithms for managing microreactor dynamics. The creation of an HIL simulation harnesses the realistic dynamics of physical analogue systems while additionally considering the challenges of variable communication delay. This collaborative effort between Oak Ridge National Laboratory and Idaho National Laboratory has resulted in a LabVIEW-based gRPC communication protocol which couples a TRANSFORM Modelica simulation of nuclear components to the ViBRANT physical hardware for realistic feedback and visual representation of control action in real time. A modular python client structure is developed to manage FMU-based Modelica simulation and real-time gRPC communication. HIL testing suggests that the modeled reactor with natural convection molten salt loop coolant configuration responds well to PID control of drum positioning for modulation of reactor core power, however, future efforts will be made to explore the added thermal inertial delay of system level control and downstream demand changes. Development of this platform with a generalized methodology provides a foundation for exploring a variety of reactor configurations and failure modes in rapid order to provide insight into the most effective avenues of study for further research and development.

McConnell, Jono [ORNL] (ORCID:0000000238984741)↗

A Magnetoencephalographic/Encephalographic (MEG/EEG) Brain-Computer Interface Driver for Interactive iOS Mobile Videogame Applications Utilizing the Hadoop Ecosystem, MongoDB, and Cassandra NoSQL Databases

In Phase I, we collected data on five subjects yielding over 90% positive performance in Magnetoencephalographic (MEG) mid-and post-movement activity. In addition, a driver was developed that substituted the actions of the Brain Computer Interface (BCI) as mouse button presses for real-time use in visual simulations. The process was interfaced to a flight visualization demonstration utilizing left or right brainwave thought movement, the user experiences, the aircraft turning in the chosen direction, or on iOS Mobile Warfighter Videogame application. The BCI’s data analytics of a subject’s MEG brain waves and flight visualization performance videogame analytics were stored and analyzed using the Hadoop Ecosystem as a quick retrieval data warehouse. In Phase II portion of the project involves the Emotiv Encephalographic (EEG) Wireless Brain–Computer interfaces (BCIs) allow for people to establish a novel communication channel between the human brain and a machine, in this case, an iOS Mobile Application(s). The EEG BCI utilizes advanced and novel machine learning algorithms, as well as the Spark Directed Acyclic Graph (DAG), Cassandra NoSQL database environment, and also the competitor NoSQL MongoDB database for housing BCI analytics of subject’s response and users’ intent illustrated for both MEG/EEG brainwave signal acquisition. The wireless EEG signals that were acquired from the OpenVibe and the Emotiv EPOC headset can be connected via Bluetooth to an iPhone utilizing a thin Client architecture. The use of NoSQL databases were chosen because of its schema-less architecture and Map Reduce computational paradigm algorithm for housing a user’s brain signals from each referencing sensor. Thus, in the near future, if multiple users are playing on an online network connection and an MEG/EEG sensor fails, or if the connection is lost from the smartphone and the webserver due to low battery power or failed data transmission, it will not nullify the NoSQL document-oriented (MongoDB) or column-oriented Cassandra databases. Additionally, NoSQL databases have fast querying and indexing methodologies, which are perfect for online game analytics and technology. In Phase II, we collected data on five MEG subjects, yielding over 90% positive performance on iOS Mobile Applications with Objective-C and C++, however on EEG signals utilized on three subjects with the Emotiv wireless headsets and (n < 10) subjects from the OpenVibe EEG database the Variational Bayesian Factor Analysis Algorithm (VBFA) yielded below 60% performance and we are currently pursuing extending the VBFA algorithm to work in the time-frequency domain referred to as VBFA-TF to enhance EEG performance in the near future. The novel usage of NoSQL databases, Cassandra and MongoDB, were the primary main enhancements of the BCI Phase II MEG/EEG brain signal data acquisition, queries, and rapid analytics, with MapReduce and Spark DAG demonstrating future implications for next generation biometric MEG/EEG NoSQL databases.

McClay, Wilbert↗

Numerical analysis of three-dimensional viscous internal flows

A 3-D Navier-Stokes code has been developed for analysis of turbomachinery blade rows and other internal flows. The Navier-Stokes equations are written in a Cartesian coordinate system rotating about the x-axis, and then mapped to a general body-fitted coordinate system. Streamwise viscous terms are neglected using the thin-layer assumption, and turbulence effects are modeled using the Baldwin-Lomax turbulence model. The equations are discretized using finite differences on stacked C-type grids and are solved using a multistage Runge-Kutta algorithm with a spatially-varying time step and implicit residual smoothing. Calculations have been made of a horseshoe vortex formed in front of a flat plate with a round leading edge standing in a turbulent endwall boundary layer. Comparisons are made with experimental data taken by Eckerle and Langston for a circular cylinder under similar conditions. Computer and measured results are compared in terms of endwall flow visualization pictures and total pressure loss contours and vector plots on the symmetry plane. Calculated details of the primary vortex show excellent agreement with the experimental data. The calculations also show a small secondary vortex not seen experimentally.

Chima, Rodrick V.↗

Numerical analysis of three-dimensional viscous internal flows

A 3-D Navier-Stokes code has been developed for analysis of turbomachinery blade rows and other internal flows. The Navier-Stokes equations are written in a Cartesian coordinate system rotating about the x-axis, and then mapped to a general body-fitted coordinate system. Streamwise viscous terms are neglected using the thin-layer assumption, and turbulence effects are modeled using the Baldwin-Lomax turbulence model. The equations are discretized using finite differences on stacked C-type grids and are solved using a multistage Runge-Kutta algorithm with a spatially-varying time step and implicit residual smoothing. Calculations have been made of a horseshoe vortex formed in front of a flat plate with a round leading edge standing in a turbulent endwall boundary layer. Comparisons are made with experimental data taken by Eckerle and Langston for a circular cylinder under similar conditions. Computer and measured results are compared in terms of endwall flow visualization pictures and total pressure loss contours and vector plots on the symmetry plane. Calculated details of the primary vortex show excellent agreement with the experimental data. The calculations also show a small secondary vortex not seen experimentally.

Chima, Rodrick V.↗

Visual perception and grasping for the extravehicular activity robot

The development of an approach to the visual perception of object surface information using laser range data in support of robotic grasping is discussed. This is a very important problem area in that a robot such as the EVAR must be able to formulate a grasping strategy on the basis of its knowledge of the surface structure of the object. A description of the problem domain is given as well as a formulation of an algorithm which derives an object surface description adequate to support robotic grasping. The algorithm is based upon concepts of differential geometry namely, Gaussian and mean curvature.

Starks, Scott A.↗

Evaluating Effectiveness of Modeling Motion System Feedback in the Enhanced Hess Structural Model of the Human Operator

In order to use the Hess Structural Model to predict the need for certain cueing systems, George and Cardullo significantly expanded it by adding motion feedback to the model and incorporating models of the motion system dynamics, motion cueing algorithm and a vestibular system. This paper proposes a methodology to evaluate effectiveness of these innovations by performing a comparison analysis of the model performance with and without the expanded motion feedback. The proposed methodology is composed of two stages. The first stage involves fine-tuning parameters of the original Hess structural model in order to match the actual control behavior recorded during the experiments at NASA Visual Motion Simulator (VMS) facility. The parameter tuning procedure utilizes a new automated parameter identification technique, which was developed at the Man-Machine Systems Lab at SUNY Binghamton. In the second stage of the proposed methodology, an expanded motion feedback is added to the structural model. The resulting performance of the model is then compared to that of the original one. As proposed by Hess, metrics to evaluate the performance of the models include comparison against the crossover models standards imposed on the crossover frequency and phase margin of the overall man-machine system. Preliminary results indicate the advantage of having the model of the motion system and motion cueing incorporated into the model of the human operator. It is also demonstrated that the crossover frequency and the phase margin of the expanded model are well within the limits imposed by the crossover model.

Zaychik, Kirill↗