Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “value.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Defining blood hematology reference values in female pig-tailed macaques ( Macaca nemestrina ) using the Isolation Forest algorithm

Background: Pig-tailed macaques (PTMs) are commonly used as preclinical models to assess antiretroviral drugs for HIV prevention research. Drug toxicities and disease pathologies are often preceded by changes in blood hematology. To better assess the safety profile of pharmaceuticals, we defined normal ranges of hematological values in PTMs using an Isolation Forest (iForest) algorithm. Methods: Eighteen female PTMs were evaluated. Blood was collected 1–24 times per animal for a total of 159 samples. Complete blood counts were performed, and iForest was used to analyze the hematology data to detect outliers. Results: Median, IQR, and ranges were calculated for 13 hematology parameters. From all samples, 22 outliers were detected. These outliers were excluded from the reference index. Conclusions: Using iForest, we defined a normal range for hematology parameters in female PTMs. This reference index can be a valuable tool for future studies evaluating drug toxicities in PTMs.

59 BASIC BIOLOGICAL SCIENCES↗

ALLOY SELECTION AND C-276 CODE DESIGN VALUE EXTENSION FOR ADVANCED MOLTEN SALT TECHNOLOGY TEST FACILITIES EXPERIMENTATION

Molten halide salts are being considered as working fluids for nuclear and concentrated solar power applications. High temperature molten fluoride and chloride salts are known to preferentially attack and deplete Cr in alloys, which leads to the use of high-Ni lower-Cr alloys in test facilities for advanced Molten Salt Technology. Alloys 600 and C-276 are two commercially available Ni alloys that have moderate Cr contents and are qualified to the maximum temperature of 649°C and 677°C (1,200°F and 1,251°F), respectively, in the Boiler and Pressure Vessel Code. Both alloys have good corrosion resistance to acids, are resistant to stress-corrosion cracking, and have long track records of use in the chemical industry. Comparatively, Alloy C-276 has a similar Cr content but much higher allowable stresses for temperatures greater than 600°C (1,112°F). Therefore, it has been considered as a structural material for test facilities that require operations at 700°C (1,292°F) or greater to develop high-temperature Molten Salt Technology. To meet the requirements, the current code design values were extended based on some experimental data. Analysis showed that above current Codified maximum temperature, strength of the alloy is mainly controlled by creep rupture life under the average stress, although the Sc creep rate criterion is close to the Favg.Savg rupture criterion. This paper presents the intended test facilities and the design requirements, alloy selection considerations, literature review, data analysis, and proposed allowable stress extension based on some creep test data for C-276 at temperatures greater than 677°C (1,251°F). Further research activities are also briefly mentioned.

Ren, Weiju↗

Modeling thin layers of analytes on substrates for spectral analysis: use of solid/liquid n and k values to model reflectance spectra

Since solids are only sometimes seen en masse in a pure bulk form, and for liquids other than water almost never, a capability to model reflectance spectra from analytes deposited on various substrates would be highly advantageous. If available, the real, n ( ν ) , and imaginary, k ( ν ) , components of the complex refractive index, n n + i k , can be used to simulate infrared spectra, accounting for reflection, refraction, and absorption phenomena as a function of wavelength. We focus on using the Pacific Northwest National Laboratory (PNNL) derived n / k vectors for solid and liquid analytes deposited as thin layers on different types of substrates including conductors, such as aluminum, and inorganic dielectrics, such as glass. The model is an adaptation of the Monte Carlo ray trace modeling program, TracePro, extended through the use of its macrolanguage. The model is tested using thin films of organic liquids including silicone oil and no. 2 diesel fuel, as well as organic solids such as caffeine and acetaminophen on aluminum and glass. The predicted spectra for the solid films were compared to experimental hemispherical reflectance data measured using a Fourier transform spectrometer with an integrating sphere. The thickness of the calculated layer is a parameter for predicting the (transflectance) spectra and is obtained using the areal density measured from gravimetric methods to generate the thin-layer samples. Comparison of the calculated spectra with experimental hemispherical reflectance data shows excellent agreement, indicating promise for the use of measured n / k data to synthesize reference spectral data. In particular, accounting for the inhomogeneity of the deposits greatly improved the match with experimental data. Finally, the theoretical modeling shows that for thicker layers (ca. 20 to 100 μm) of typical organics possessing moderately strong k values, the longwave infrared features are often saturated and better spectral contrast is obtained from the overtone/combination bands in the shortwave infrared.

42 ENGINEERING↗

Evaluation of S-values and dose distributions for {sup 90}Y, {sup 131}I, {sup 166}Ho, and {sup 188}Re in seven lobes of the rat liver

Purpose: Rats have been widely used in radionuclide therapy research for the treatment of hepatocellular carcinoma (HCC). This has created the need to assess rat liver absorbed radiation dose. In most dose estimation studies, the rat liver is considered as a homogeneous integrated target organ with a tissue composition assumed to be similar to that of human liver tissue. However, the rat liver is composed of several lobes having different anatomical and chemical characteristics. To assess the overall impact on rat liver dose calculation, the authors use a new voxel-based rat model with identified suborgan regions of the liver. Methods: The liver in the original cryosectional color images was manually segmented into seven individual lobes and subsequently integrated into a voxel-based computational rat model. Photon and electron particle transport was simulated using the MCNPX Monte Carlo code to calculate absorbed fractions and S-values for {sup 90}Y, {sup 131}I, {sup 166}Ho, and {sup 188}Re for the seven liver lobes. The effect of chemical composition on organ-specific absorbed dose was investigated by changing the chemical composition of the voxel filling liver material. Radionuclide-specific absorbed doses at the voxel level were further assessed for a small spherical hepatic tumor. Results: The self-absorbed dose for different liver lobes varied depending on their respective masses. A maximum difference of 3.5% was observed for the liver self-absorbed fraction between rat and human tissues for photon energies below 100 keV. {sup 166}Ho and {sup 188}Re produce a uniformly distributed high dose in the tumor and relatively low absorbed dose for surrounding tissues. Conclusions: The authors evaluated rat liver radiation doses from various radionuclides used in HCC treatments using a realistic computational rat model. This work contributes to a better understanding of all aspects influencing radiation transport in organ-specific radiation dose evaluation for preclinical therapy studies, from tissue composition to organ morphology and activity distribution.

61 RADIATION PROTECTION AND DOSIMETRY↗

A characterization of robust radiation therapy treatment planning methods-from expected value to worst case optimization

Purpose: To characterize a class of optimization formulations used to handle systematic and random errors in radiation therapy, and to study the differences between the methods within this class. Methods: The class of robust methods that can be formulated as minimax stochastic programs is studied. This class generalizes many previously used methods, ranging between optimization of the expected and the worst case objective value. The robust methods are used to plan intensity-modulated proton therapy (IMPT) treatments for a case subject to systematic setup and range errors, random setup errors with and without uncertain probability distribution, and combinations thereof. As reference, plans resulting from a conventional method that uses a margin to account for errors are shown. Results: For all types of errors, target coverage robustness increased with the conservativeness of the method. For systematic errors, best case organ at risk (OAR) doses increased and worst case doses decreased with the conservativeness. Accounting for random errors of fixed probability distribution resulted in heterogeneous dose. The heterogeneities were reduced when uncertainty in the probability distribution was accounted for. Doing so, the OAR doses decreased with the conservativeness. All robust methods studied resulted in more robust target coverage and lower OAR doses than the conventional method. Conclusions: Accounting for uncertainties is essential to ensure plan quality in complex radiation therapy such as IMPT. The utilization of more information than conventional in the optimization can lead to robust target coverage and low OAR doses. Increased target coverage robustness can be achieved by more conservative methods.

60 APPLIED LIFE SCIENCES↗

Patient radiation doses in interventional cardiology in the U.S.: Advisory data sets and possible initial values for U.S. reference levels

Purpose: To determine patient radiation doses from interventional cardiology procedures in the U.S and to suggest possible initial values for U.S. benchmarks for patient radiation dose from selected interventional cardiology procedures [fluoroscopically guided diagnostic cardiac catheterization and percutaneous coronary intervention (PCI)]. Methods: Patient radiation dose metrics were derived from analysis of data from the 2008 to 2009 Nationwide Evaluation of X-ray Trends (NEXT) survey of cardiac catheterization. This analysis used deidentified data and did not require review by an IRB. Data from 171 facilities in 30 states were analyzed. The distributions (percentiles) of radiation dose metrics were determined for diagnostic cardiac catheterizations, PCI, and combined diagnostic and PCI procedures. Confidence intervals for these dose distributions were determined using bootstrap resampling. Results: Percentile distributions (advisory data sets) and possible preliminary U.S. reference levels (based on the 75th percentile of the dose distributions) are provided for cumulative air kerma at the reference point (K{sub a,r}), cumulative air kerma-area product (P{sub KA}), fluoroscopy time, and number of cine runs. Dose distributions are sufficiently detailed to permit dose audits as described in National Council on Radiation Protection and Measurements Report No. 168. Fluoroscopy times are consistent with those observed in European studies, but P{sub KA} is higher in the U.S. Conclusions: Sufficient data exist to suggest possible initial benchmarks for patient radiation dose for certain interventional cardiology procedures in the U.S. Our data suggest that patient radiation dose in these procedures is not optimized in U.S. practice.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-J-249: Correlation of Mean Lung Ventilation Value with Ratio of Total Lung Volumes

Purpose: Lung ventilation function measured from 4D-CT and from breathing correlated CT images is a novel concept to incorporate the lung physiologic function into treatment planning of radiotherapy. The calculated ventilation functions may vary from different breathing patterns, affecting evaluation of the treatment plans. The purpose of this study is to correlate the mean lung ventilation value with the ratio of the total lung volumes obtained from the relevant CTs. Methods: A ventilation map was calculated from the variations of voxel-to-voxel CT densities from two breathing phases from either 4D-CT or breathing correlated CTs. An open source image registration tool of Plastimatch was used to deform the inhale phase images to the exhale phase images. To calculate the ventilation map inside lung, the whole lung was delineated and the tissue outside the lung was masked out. With a software tool developed in house, the 3D ventilation map was then converted in the DICOM format associated with the planning CT images. The ventilation map was analyzed on a clinical workstation. To correlate ventilation map thus calculated with lung volume change, the total lung volume change was compared the mean ventilation from our method. Results: Twenty two patients who underwent stereotactic body irradiation for lung cancer was selected for this retrospective study. For this group of patients, the ratio of lung volumes for the inhale (Vin ) and exhale phase (Vex ) was shown to be linearly related to the mean of the local ventilation (Vent), Vin/Vex=1.+0.49*Vent (R2=0.93, p<0.01). Conclusion: The total lung volume change is highly correlated with the mean of local ventilation. The mean of local ventilation may be useful to assess the patient's lung capacity.

60 APPLIED LIFE SCIENCES↗

Methods, software and datasets to verify DVH calculations against analytical values: Twenty years late(r)

Purpose: The authors designed data, methods, and metrics that can serve as a standard, independent of any software package, to evaluate dose-volume histogram (DVH) calculation accuracy and detect limitations. The authors use simple geometrical objects at different orientations combined with dose grids of varying spatial resolution with linear 1D dose gradients; when combined, ground truth DVH curves can be calculated analytically in closed form to serve as the absolute standards. Methods: DICOM RT structure sets containing a small sphere, cylinder, and cone were created programmatically with axial plane spacing varying from 0.2 to 3 mm. Cylinders and cones were modeled in two different orientations with respect to the IEC 1217 Y axis. The contours were designed to stringently but methodically test voxelation methods required for DVH. Synthetic RT dose files were generated with 1D linear dose gradient and with grid resolution varying from 0.4 to 3 mm. Two commercial DVH algorithms—PINNACLE (Philips Radiation Oncology Systems) and PlanIQ (Sun Nuclear Corp.)—were tested against analytical values using custom, noncommercial analysis software. In Test 1, axial contour spacing was constant at 0.2 mm while dose grid resolution varied. In Tests 2 and 3, the dose grid resolution was matched to varying subsampled axial contours with spacing of 1, 2, and 3 mm, and difference analysis and metrics were employed: (1) histograms of the accuracy of various DVH parameters (total volume, D{sub max}, D{sub min}, and doses to % volume: D99, D95, D5, D1, D0.03 cm{sup 3}) and (2) volume errors extracted along the DVH curves were generated and summarized in tabular and graphical forms. Results: In Test 1, PINNACLE produced 52 deviations (15%) while PlanIQ produced 5 (1.5%). In Test 2, PINNACLE and PlanIQ differed from analytical by >3% in 93 (36%) and 18 (7%) times, respectively. Excluding D{sub min} and D{sub max} as least clinically relevant would result in 32 (15%) vs 5 (2%) scored deviations for PINNACLE vs PlanIQ in Test 1, while Test 2 would yield 53 (25%) vs 17 (8%). In Test 3, statistical analyses of volume errors extracted continuously along the curves show PINNACLE to have more errors and higher variability (relative to PlanIQ), primarily due to PINNACLE’s lack of sufficient 3D grid supersampling. Another major driver for PINNACLE errors is an inconsistency in implementation of the “end-capping”; the additional volume resulting from expanding superior and inferior contours halfway to the next slice is included in the total volume calculation, but dose voxels in this expanded volume are excluded from the DVH. PlanIQ had fewer deviations, and most were associated with a rotated cylinder modeled by rectangular axial contours; for coarser axial spacing, the limited number of cross-sectional rectangles hinders the ability to render the true structure volume. Conclusions: The method is applicable to any DVH-calculating software capable of importing DICOM RT structure set and dose objects (the authors’ examples are available for download). It includes a collection of tests that probe the design of the DVH algorithm, measure its accuracy, and identify failure modes. Merits and applicability of each test are discussed.

60 APPLIED LIFE SCIENCES↗

SU-E-T-581: On the Value of LET as a Radiation Quality Descriptor for RBE

Purpose: To investigate the relationship between linear energy transfer (LET) and relative biological effectiveness (RBE) for protons and light ions, and the corresponding role of LET as a descriptor of radiation quality of hadron therapy. Methods: Monte Carlo (MC) proton and light ion (He, Li, C) tracks with LET < 30 eV nm{sup -1} were generated in an event-by-event mode. They were overlaid on a cell nucleus model containing 6×10{sup 9} nucleotide base pairs using an isotropic irradiation procedure that provides electronic equilibrium. Strand breaks (sbs) were scored in the DNA sugar-phosphate groups and further sub-classified into single or double sbs (ssbs or dsbs). Distributions of ssbs and dsbs for 2 Gy fractions were calculated to estimate RBE for the induction of initial dsbs with reference to {sup 60}Co. Additionally, sbs were classified based on their complexity (i.e. the number of sbs in each cluster). Results: An increase in LET for light ions of the same atomic number or a decrease in atomic number for ions of the same LET resulted in a lower kinetic energy of emitted secondary electrons. The clustering of DNA damage was more pronounced as reflected by the increase in proton RBE from ∼ 1.75 to 4 for LET values of 7 to 28 eV nm{sup -1}. A significant RBE decrease between protons, He, Li and C ions of the same LET was also noticed as function of the atomic number. Significant differences in ssbs and dsbs complexities were also seen for particles with the same LET, potentially supporting a clustering-based radiation quality descriptor. Conclusion: The LET-RBE relationships were simulated for proton and light ions and exhibited expected trends, including different RBEs for particles with the same LET but different atomic numbers. A complexity based radiation quality descriptor may allow better differentiation of RBE between radiation fields of similar LET. We would like to acknowledge support from the Fonds de recherche du Quebec Sante (FRQS), from the CREATE Medical Physics Research Training Network grant (number 432290) of NSERC, support from NSERC under grants RGPIN 397711-11 and RGPIN-2014-06475 and support from CIHR under grants MOP-114910, MOP-136774 and MOP-102550.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-DE-304-01: The Abt Study of Medical Physicist Work Values for Radiation Oncology Physics Services: Round IV

The Abt study of medical physicist work values for radiation oncology physics services, Round IV is completed. It supersedes the Abt III study of 2008. The 2015 Abt study measured qualified medical physicist (QMP) work associated with routine radiation oncology procedures as well as some special procedures. As before, a work model was created to allow the medical physicist to defend QMP work based on both routine and special procedures service mix. The work model can be used to develop a cost justification report for setting charges for radiation oncology physics services. The Abt study Round IV was designed to empower the medical physicist to negotiate a service or employment contract with providers based on measured national QMP workforce and staffing data. For a variety of reasons, the diagnostic imaging contingent of AAPM has had a more difficult time trying estimate workforce requirements than their therapy counterparts. Over the past several years, the Diagnostic Work and Workforce Study Subcommittee (DWWSS) has collected survey data from AAPM members, but the data have been very difficult to interpret. The DWWSS has reached out to include more AAPM volunteers to create a more full and accurate representation of actual clinical practice models on the subcommittee. Though much work remains, through hours of discussion and brainstorming, the DWWSS has somewhat of a clear path forward. This talk will provide attendees with an update on the efforts of the subcommittee. Learning Objectives: Understand the new information documented in the Abt studies. Understand how to use the Abt studies to justify medical physicist staffing. Learn relevant historical information on imaging physicist workforce. Understand the process of the DWWSS in 2014. Understand the intended path forward for the DWWSS.

60 APPLIED LIFE SCIENCES↗

SU-F-I-01: Normalized Mean Glandular Dose Values for Dedicated Breast CT Using Realistic Breast-Shaped Phantoms

Purpose: To estimate normalized mean glandular dose values for dedicated breast CT (DgN-CT) using breast CT-derived phantoms and compare to estimations using cylindrical phantoms. Methods: Segmented breast CT (bCT) volume data sets (N=219) were used to measure effective diameter profiles and were grouped into quintiles by volume. The profiles were averaged within each quintile to represent the range of breast sizes found clinically. These profiles were then used to generate five voxelized computational phantoms (V1, V2, V3, V4, V5 for the small to large phantom sizes, respectively), and loaded into the MCNP6 lattice geometry to simulate normalized mean glandular dose coefficients (DgN-CT) using the system specifications of the Doheny-prototype bCT scanner in our laboratory. The DgN-CT coefficients derived from the bCT-derived breast-shaped phantoms were compared to those generated using a simpler cylindrical phantom using a constant volume, and the following constraints: (1) Length=1.5*radius; (2) radius determined at chest wall (Rcw), and (3) radius determined at the phantom center-of-mass (Rcm). Results: The change in Dg-NCT coefficients averaged across all phantom sizes, was - 0.5%, 19.8%, and 1.3%, for constraints 1–3, respectively. This suggests that the cylindrical assumption is a good approximation if the radius is taken at the breast center-of-mass, but using the radius at the chest wall results in an underestimation of the glandular dose. Conclusion: The DgN-CT coefficients for bCT-derived phantoms were compared against the assumption of a cylindrical phantom and proved to be essentially equivalent when the cylinder radius was set to r=1.5/L or Rcm. While this suggests that for dosimetry applications a patient’s breast can be approximated as a cylinder (if the correct radius is applied), this assumes a homogenous composition of breast tissue and the results may be different if the realistic heterogeneous distribution of glandular tissue is considered. Research reported in this paper was supported in part by the National Cancer Institute of the National Institutes of Health under award R01CA181081. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institue of Health.

60 APPLIED LIFE SCIENCES↗

SU-F-I-75: Half-Value Layer Thicknesses and Homogeneity Coefficients for Fluoroscopic X-Ray Beam Spectra Incorporating Spectral Filtration

Purpose: The purpose of this investigation is to quantify various first half-value-layers (HVLs), second HVLs and homogeneity coefficients (HCs) for a state-of-the-art fluoroscope utilizing spectral (copper) filtration. Methods: A Radcal (Monrovia, Ca) AccuPro dosimeter with a 10×6-6 calibrated ionization chamber was used to measure air kerma for radiographic x-ray exposures made on a Siemens (Erlangen, Germany) Artis ZeeGo fluoroscope operated in the service mode. The ionization chamber was centered in the x-ray beam at 72 cm from the focal spot with a source-to-image-distance of 120 cm. The collimators were introduced to limit the x-ray field to approximately 5 cm × 5 cm at the ionization chamber plane. Type-1100 aluminum filters, in 0.5 mm increments, were used to determine the HVL. Two HVL calculation methods were used, log-linear interpolation and Lambert-W interpolation as described by Mathieu [Med Phys, 38(8), 4546 (2011)]. Multiple measurements were made at 60, 80, 100, 120 kVp at spectral filtration thicknesses of 0, 0.1, 0.3, 0.6 and 0.9 mm. Results: First HVL, second HVL, and HCs are presented for the fluoroscopic x-ray beam spectra indicated above, with nearly identical results from the two interpolation methods. Accuracy of the set kVp was also determined and deviated less than 2%. First HVLs for fluoroscopic x-ray beam spectra without spectral filtration determined in our study were 7%–16% greater than previously published data by Fetterly et al. [Med Phys, 28, 205 (2001)]. However, the FDA minimum HVL requirements changed since that publication, requiring larger HVLs as of 2006. Additionally, x-ray tube and generator architecture have substantially changed over the last 15 years providing different beam spectra. Conclusion: X-ray beam quality characteristics for state-of-the-art fluoroscopes with spectral filtration have not been published. This study provides reference data which will be useful for defining beam qualities encountered on fluoroscopes using spectral filtration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-C-BRB-04: Observations of a Nuclear Radiologist on the Value of the Medical Physicist

With the profound changes currently occurring in medicine, the role of the medical physicist cannot stagnate, but must evolve to meet the challenges and opportunities that are presented. Medical physicists must understand these changes and establish themselves not only as relevant but as leaders in this new environment. We must increase our presence in clinical settings such as tumor boards, patient rounds, and the development of new diagnosis, imaging, and treatment techniques. By establishing ourselves as competent scientists, we can and must participate in the development of technologies through research, teaching, and clinical implementation. As medical physicists we must define our roles and value to our physician colleagues, patients, referring physicians, and senior administrators. We cannot afford to be viewed solely as quality assurance technologists, but need to move forward in step with medical and practice advances, becoming recognized as having a leadership role in providing quality research, technological development, and quality patient care. In this session, four leaders in medical research and healthcare will discuss their observations on how medical physicists have contributed to advancements in healthcare and opportunities to continue leadership in providing quality medicine through the applications of physics to research, education, and clinical practice. Learning Objectives: Understand the changes in the healthcare environment and how medical physicists can contribute to improving patient care. Learn how medical physicists are currently leading research efforts to improve clinical imaging and diagnosis. Understand the role of medical physicists in developing new technology and leading its translation into clinical care.

60 APPLIED LIFE SCIENCES↗

On Double-Valued Wave Functions in the Description of Intramolecular Coordinate Motions

It is shown that the appearance of double-valued wave functions in constructing the discrete-spectrum classification of coordinate motions in molecules with a linear core and two identical tops using the CNPI-group methods is the consequence of a physically incorrect determination of the action of symmetry operations on variables of a configuration space of the molecule.

74 ATOMIC AND MOLECULAR PHYSICS↗

Equilibrium values and dynamics of the net magnetic moment of a system of magnetic dipoles

Equilibrium states of different systems formed by coupled spherical bodies with dipole magnetic moments have been investigated using a numerical analysis. The bistable states and the corresponding values of the net magnetic moment are determined for a number of planar and three-dimensional systems of dipoles, and the conditions providing the existence of orientational configurations of coupled dipoles involved in the bistability are analyzed. The disturbances of the magnetic moment due to the quasi-static passage of an additional dipole and the dynamic modes excited by a homogeneous alternating magnetic field and represented by periodic, quasi-periodic, and chaotic oscillations of the magnetic moment of the system are considered for several types of systems. The bifurcation diagrams of the dynamic modes are constructed, and the specific features typical of the systems under consideration are revealed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Neutron field reconstruction with consideration of the spatial correlation of the cross-section value error

A method for reconstructing the neutron field in a reactor with consideration of the spatial correlation of the cross-section value error was analyzed. It was shown that this method is more accurate than the classical approach to reconstruction. An efficient way of using this technique was proposed. The efficiency for the RBMK critical test facility was estimated.

74 ATOMIC AND MOLECULAR PHYSICS↗

Q{sub 2} evolution of parton distributions at small values of x: Effective scale for combined H1 and ZEUS data on the structure function F{sub 2}

An expression for the structure function F{sub 2} in the form of Bessel functions at small values of the Bjorken variable x is used. This expression was derived for a flat initial condition in the Dokshitzer-Gribov-Lipatov-Altarelli-Parisi (DGLAP) evolution equations. The argument of the strong coupling constant was chosen in such a way as to annihilate the singular part of the anomalous dimensions in the next-to-leading-order of perturbation theory. This choice, together with the frozen and analytic versions of the strong coupling constant, is used to analyze combined data of the H1 and ZEUS Collaborations obtained recently for the structure function F{sub 2}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The temperature dependence of the conductivity peak values in the single and the double quantum well nanostructures n-InGaAs/GaAs after IR-illumination

The dependences of the longitudinal and Hall resistances on a magnetic field in n-InGaAs/GaAs heterostructures with a single and double quantum wells after infrared illumination are measured in the range of magnetic fields Ð’ = 0–16 T and temperatures T = 0.05–4.2 K. Analysis of the experimental results was carried out on a base of two-parameter scaling hypothesis for the integer quantum Hall effect. The value of the second (irrelevant) critical exponent of the theory of two-parameter scaling was estimated.

36 MATERIALS SCIENCE↗