Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timing detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Suomi NPP VIIRS DNB and RSB M Bands Detector-To-Detector and HAM Side Calibration Differences Assessment Using a Homogenous Ground Target

Near-nadir observations of the Libya 4 site from the S-NPP VIIRS Day-Night Band (DNB) and Moderate resolution Bands (M bands) are used to assess the detector calibration stability and half-angle mirror (HAM) side differences. Almost seven years of Sensor Data Records products are extracted from the Libya 4 site center over an area of 32×32 pixels. The mean values of the radiance from individual detectors per HAM side are computed separately. The comparison of the normalized radiance between detectors indicates that the detector calibration differences are wavelength dependent and the differences have been slowly increasing with time for short wavelength bands, especially for M1-M4. The maximum annual average differences between DNB detectors are 0.77% in 2017 at HAM-A. For the M bands, the maximum detector differences in 2017 are 1.7% for M1, 1.8% for M2, 1.3% for M3, 1.2% for M4, 0.67% for M5, 0.75% for M7, 0.57% for M8, 13% for M9, 0.63% for M10, and 0.66% for M11. The average HAM side A to B difference in 2017 are 0.00% for DNB, 0.22% for M1, 0.17% for M2, 0.15% for M3, 0.09% for M4, -0.07% for M5, 0.02% for M7, 0.01% for M8, 1.4% for M9, 0.01% for M10, and 0.03% for M11. Results for M6 are not available due to the signal saturation and M9 results are not accurate because of the low reflectance from the desert site and the strong atmospheric absorption in this channel. The results in this study help scientists better understand each detector’s performance and HAM side characteristics. Additionally, they provide evidence and motivation for future VIIRS calibration improvements.

SNPP VIIRS↗

Large-area photon calorimeter with Ir-Pt bilayer transition-edge sensor for the CUPID experiment

CUPID is a next-generation neutrinoless double-β decay experiment that will require cryogenic light detectors to improve background suppression, via the simultaneous readout of heat and light channels from its scintillating crystals. In this work, we showcase light detectors based on an alternative Ir-Pt bilayer transition-edge sensor. We have performed a systematic study to improve the thermal coupling between the photon absorber and the sensor, and thereby its responsivity. Our first devices meet CUPID's baseline noise requirement of < 100 eV rms. Our detectors have risetimes of approximately 180μs and measured timing jitter of < 20μs for the expected signal to noise at the Q value of the decay, which achieves the CUPID's criterion of rejecting two-neutrino double-β decay pile-up events. In conclusion, the current work will inform the fabrication of future devices, culminating in the final TES design and a scaleable readout scheme for CUPID.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Systems and methods for optical measurement of cross-wind

Various technologies pertaining to optical measurement of cross-wind are described herein. A beam of light is emitted along a trajectory through a shooting space from a location of a shooter to a target using a laser. The beam is reflected by the target, and the beam is received at two optical detectors. Due to changes in the index of refraction of air along the path of the beam, an envelope signal atmospherically encoded on the beam is received at each of the two apertures at different times. A signal analyzer receives a signal from each of the detectors and outputs data indicative of an average speed of the cross-wind along the trajectory in the shooting space based upon a time delay between the signals.

Bagwell, Brett↗

Mapping Wildfires In Nearly Real Time

Airborne infrared-sensing system flies over wildfire as infrared detector in system and navigation subsystem generate data transmitted to firefighters' camp. There, data plotted in form of map of fire, including approximate variations of temperature. System, called Firefly, reveals position of fires and approximate thermal intensities of regions within fires. Firefighters use information to manage and suppress fires. Used for other purposes with minor modifications, such as to spot losses of heat in urban areas and to map disease and pest infestation in vegetation.

Nichols, Joseph D.↗

Ultra-Fast 4H-SiC LGAD With Etched Termination and Field Plate

The design, fabrication, and demonstration of a novel Silicon Carbide Low Gain Avalanche Detector (4HSiC LGAD), exhibiting an ultra-fast time response and excellent time resolution, are reported. Here, the use of field plates is proposed to suppress the high electric field caused by the negative bevel-etched angle in 4H-SiC LGADs based on TCAD simulations. Experimental measurements confirm that the field plate significantly increases the breakdown voltage of the 4H-SiC LGADs. Gain and time resolution are measured by using the ultraviolet transient current technique (UV-TCT) showing that 4H-SiC LGADs possess excellent timing performance, with a time resolution better than 35 ps for the injected laser signal with single minimum ionizing particle (MIP) charges generation at room temperature. Additionally, the gain suppression effect in a 4H-SiC LGAD is observed for the first time.

43 PARTICLE ACCELERATORS↗

Spatial Characterization of PACE OCI ETU Using Time-Delay Mode

The OCI (Ocean Color Instrument) is the main sensor on the upcoming PACE (Plankton Aerosol Cloud ocean Ecosystem) mission. OCI has two hyperspectral CCD sensors covering 340nm to 885nm and 9 SWIR (Short Wave IR) bands from 940nm to 2260nm. SWIR bands have nominal 1km ground pixel size and CCD bands have native 1/8 km ground pixel size in diagnostic mode that will be aggregated into 1km pixels to improve SNR and meet the data rate constraints. OCI has a rotating telescope that is synchronized to the readout of the CCD and SWIR detectors. Full pre-launch system level testing for the OCI ETU (Engineering Test Unit) was completed in June 2021.With time-delayed scan mode, a sub-pixel level time-delay step is applied to the detector readout. This sub-pixel level time-delay step causes a sub-pixel level shift in the start of the data collection. After collecting time-delay step scans with different step sizes, a scan profile with sub-pixel resolution can be constructed. 1/8 and 1/4 of CCD pixel resolutions were achieved using this mode. In this paper, the OCI time-delayed scan mode will be described as well as how it was used to calculate OCI’s high spatial resolution PSF (Point Spread Function), IFOV (instantaneous Field of View), MTF (Modulation Transfer Function), and BBR (Band to Band Registration).

PACE↗

Sub-keV design for the National Ignition Facility’s soft x-ray Opacity Spectrometer (OpSpec) and expansion plans for time-resolved measurements

When compared with the National Ignition Facility’s (NIF) original soft x-ray opacity spectrometer, which used a convex cylindrical design, an elliptically shaped design has helped to increase the signal-to-noise ratio and eliminated nearly all reflections from alternate crystal planes. The success of the elliptical geometry in the opacity experiments has driven a new elliptical geometry crystal with a spectral range covering 520–1100 eV. When coupled with the primary elliptical geometry, which spans 1000–2100 eV, the new sub-keV elliptical geometry helps to cover the full iron L-shell and major oxygen transitions important to solar opacity experimentation. The new design has been built and tested by using a Henke x-ray source and shows the desired spectral coverage. Additional plans are underway to expand these opacity measurements into a mode of time-resolved detection, ~1 ns gated, but considerations for the detector size and photometrics mean a crystal geometry redesign. Here, the new low-energy geometry, including preliminary results from the NIF opacity experiments, is presented along with the expansion plans into a time-resolved platform.

47 OTHER INSTRUMENTATION↗

GaAs X-Ray Diodes (LDRD Annual Report FY2019)

Ongoing work at the Z Machine on the development of warm x-ray sources in support of national security missions requires fast x-ray diagnostics with sensitivities significantly higher than what is commercially available. Our team represents a collaborative effort between MESA and Z to fabricate GaAs x-ray detectors that meet this need. The delivered detectors have now been fielded in several Z shot series and are providing hard x-ray data to physicists at Z. In addition to improved time response and hard x-ray sensitivity compared to commercial detectors, the devices fabricated at MESA show much more consistent device-to-device signal levels. This improved repeatability gives researchers at Z new quantitative data for source development efforts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recurrent brief X-ray bursts from the globular cluster NGC 6624

Observational data are presented on ten brief X-ray bursts, recurrent at nearly equal time intervals, recorded during a two-day observation of 3U 1820-30 in the globular cluster NGC 6624 with the wide-field modulation collimator detectors on the SAS-3 X-ray observatory. The occurrence times were fitted by least squares to a linear sequence with an rms deviation of 621 sec, corresponding to a phase jitter of 3.9%. The bursts were observed in two energy channels. For a sequence of five of the most clearly observed bursts, the 2-6 keV rate rose to its peak value in about 1 sec and then decayed to preburst level in about 10 sec. The 6-11 keV rate rose more slowly and decayed similarly. The smooth decay of their averaged light curve suggests the temporal evolution may have a geometrical origin, where Compton scattering in a surrounding cloud of hot plasma stretches the pulse out and causes a progressive hardening of the spectrum.

Clark, G. W.↗

New results on mean time-to-first-slip for a first-order loop

Approximate results are derived from a new expression for the mean time-to-first-slip for a first-order loop with arbitrary periodic equivalent phase detector characteristic in the presence of frequency detuning. They are accurate for loop signal-to-noise ratios greater than 3 dB or less than 0 dB. The approximations found serve to provide insight into the mean first slip time dependence on the shape of the equivalent phase detector characteristic and the frequency detuning, and dependence on loop parameters. The new expression itself is also of theoretical interest, since it allows one to explicitly express the stationary phase error probability density function and probability current in terms of the mean first slip time. This sheds further light on the interconnections between the conventional modulo-2 pi approach and the renewal theory approach to the Fokker-Planck method. Extensions to nonperiodic equivalent phase detector characteristics are also considered.

Chie, C. M.↗

Projected sensitivities of the LUX-ZEPLIN experiment to new physics via low-energy electron recoils

LUX-ZEPLIN is a dark matter detector expected to obtain world-leading sensitivity to weakly-interacting massive particles interacting via nuclear recoils with a ∼7-tonne xenon target mass. This paper presents sensitivity projections to several low-energy signals of the complementary electron recoil signal type: 1) an effective neutrino magnetic moment, and 2) an effective neutrino millicharge, both for 𝑝⁢𝑝-chain solar neutrinos, 3) an axion flux generated by the Sun, 4) axionlike particles forming the Galactic dark matter, 5) hidden photons, 6) mirror dark matter, and 7) leptophilic dark matter. World-leading sensitivities are expected in each case, a result of the large 5.6 t 1000 d exposure and low expected rate of electron-recoil backgrounds in the <100 keV energy regime. A consistent signal generation, background model and profile-likelihood analysis framework is used throughout.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigation of background electron emission in the LUX detector

Dual-phase xenon detectors, as currently used in direct detection dark matter experiments, have observed elevated rates of signals from electron emission processes in the low energy region. While this background negatively impacts detector performance in various ways, its origins have only been partially studied. In this paper, we report a systematic investigation of the electron pathologies observed in the LUX dark matter experiment. We characterize different electron populations based on their emission intensities and their correlations with preceding energy depositions in the detector. By studying these electron backgrounds under different experimental conditions, we identified the possible mechanisms that may contribute to the electron emission. We report the observed electron event rate in LUX after background rejection, and discuss how such backgrounds can be further mitigated in ongoing and future xenon-based dark matter experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Summer 2021 Co-op Report: X-Ray Scintillation Detector (A Co-op Work Experience Report)

The M-3 team was in need of a detector that could be used properly characterize their X-Ray machines. It can also be used to diagnose the X-ray in the case that problems arise before or during an experiment. They put me in charge of designing, ordering, and constructing said detector. After doing research, I found that scintillation-based detectors would be the best diagnostic tool for this purpose. It will allow the team to collect a full photon count of the X-ray pulse as well as provide spectroscopy functions with which we can view photon counts at different energy levels. This will also allow them to calculate an accurate dose given from the machine. Due to lead times, the crystals are still in manufacturing, thus the detector could not be completed. Although the designs and calculations needed to construct and operate the scintillator have been completed which is what I will be presenting in this document. Compared to the detectors being used before, my design offers a cheaper and far more efficient alternative.

42 ENGINEERING↗

Prospects for distinguishing supernova models using a future neutrino signal

The next Galactic core-collapse supernova (SN) should yield a large number of observed neutrinos. Here, using Bayesian techniques, we show that with a SN at a known distance up to 25 kpc, the neutrino events in a water Cherenkov detector similar to Super-Kamiokande (SK) could be used to distinguish between seven one-dimensional neutrino emission models assuming no flavor oscillations or the standard Mikheyev-Smirnov-Wolfenstein effect. Some of these models could still be differentiated with a SN at a known distance of 50 kpc. We also consider just the relative distributions of neutrino energy and arrival time predicted by the models and find that a detector like SK meets the requirement to distinguish between these distributions with a SN at an unknown distance up to $\mathrm{\sim 10 kpc.}$

79 ASTRONOMY AND ASTROPHYSICS↗

Identifying environmentally induced calibration changes in cryogenic RF axion detector systems using deep neural networks

The axion is a compelling hypothetical particle that could account for the dark matter in our universe while simultaneously solving the strong CP problem in quantum chromodynamics. The most sensitive axion detection technique demonstrated so far makes use of a high Q cavity immersed in a strong magnetic field, where axions are converted to microwave photons. This is called an axion haloscope and has primarily targeted the 1–10 GHz range. As searches scan up in axion mass, toward the parameter space favored by theoretical predictions, individual cavity sizes decrease in order to achieve higher frequencies. This shrinking cavity volume translates directly to a loss in signal-to-noise, motivating the plan to replace individual cavity detectors with arrays of cavities. When the transition from one to (N) multiple cavities occurs, haloscope searches are anticipated to become much more complicated to operate, requiring N times as many measurements but also the new requirement that N detectors operate in unison, which can be achieved by locking them to a common frequency. To offset this anticipated increase in detector complexity, we aim to develop new tools for diagnosing experiments using neural networks. Current experiments monitor scattering parameters of their receiver for periodically measuring cavity quality factor and coupling. However, off-resonant data remain relatively useless. In this paper, we ask if it is possible that off-resonant information contained in vector network analyzer scans could be used to diagnose equipment failures/anomalies and measure physical conditions (e.g., temperatures and ambient magnetic field). We demonstrate a proof-of-concept that AI techniques can help manage the complexity of an axion haloscope search for operators.

Engel, Andrew W. [Pacific Northwest National Labor↗

Probabilistic Processing of Asynchronous Geiger-Mode Avalanche Photodiode Arrays for Background Rate Measurements

A system-level performance evaluation of Geiger-mode avalanche photodiode (GmAPD) arrays requires accurate measurement and prediction of the background rate of the device due to dark counts and other spurious detection events. Since a GmAPD detector reports only a binary value and timestamp associated with an avalanche event, dark count rates are typically measured by averaging thousands of frames to support a statistically significant measurement. For both synchronous and asynchronous detector, the Poisson distributed background rates are referenced to the time each pixel is armed. Unlike for synchronous GmAPD imagers where all the pixels are armed to an array-wide arm signal, an asynchronous pixel operates independently from its neighboring pixels; requiring the background rates to be calculated using an interarrival histogram. For both types of imagers, the background rate is typically evaluated by fitting an exponential distribution to a fixed window within a measured histogram of time intervals between detection events However, if the statistics of the background rate are insufficient – whether that is due to low population sizes, saturation, or a large dynamic range of population size across the array, the pixel, or array-wide, performance metrics may report results with varying accuracy. This paper reports on an implementation of an algorithm that evaluates GmAPD background rates based on statistical metrics rather than fixed windows. The algorithm functions by determining the appropriate integration window within the interarrival time histogram based on a per-pixel count rate set by a predetermined tolerable measurement error. The implementation of the algorithm allows us to characterize GmAPD arrays with orders of magnitude spread in background rates across the detector using common statistical parameters.

Mumolo, J.↗

Beam Dynamics Challenges in the Muon g-2 Experiment

The muon&s;s anomalous magnetic moment $a_{\mu}$ has hinted at physics beyond the standard model for nearly 20 years. The Muon $g-2$ experiment at Fermilab aims to measure $a_{\mu}$ to 140 parts per billion (ppb) precision. The 460 ppb result from its first data run (Run-1), released in 2021, agreed with the previous 2006 Brookhaven Muon $g-2$ result. The experimental average stands in tension with the standard model theory $a_{\mu}$ prediction by $4.2 \sigma$. The result of Run-2/3 data analysis is set be released in summer 2023, and will improve on the Run-1 precision by a factor of two. With the data collected in all six runs, the experiment is on track to produce a 140 ppb measurement of $a_{\mu}$. If the experiment and theory central values are both unchanged, the tension would exceed $5 \sigma$. The measurement is accomplished by injecting muons into a magnetic storage ring and precisely measuring two observable frequencies: $\omega_a$, the muons&s; anomalous precession frequency, and $\tilde{\omega}&s;_p$, the precession frequency of protons which determines the magnetic field strength experienced by the muons. This thesis presents a selection of muon beam dynamics effects which are critical for reaching the experiment precision goal. A system of detectors assists with the challenging beam injection into the storage ring, and a measurement of the injected beam provides input for simulating the stored beam dynamics. A new method is introduced to reduce a critical systemic caused by time dependence in the stored beam momentum, enabled by a detector which directly profiles the stored beam. Finally the analysis of $\tilde{\omega}&s;_p$, the muon-weighted magnetic field, for the Run-2/3 result is presented. Systematics of $\tilde{\omega}&s;_p$ due to beam effects are evaluated in detail, and shown to be sub-dominant.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗