Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “target setting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Crater size estimates for large-body terrestrial impact

Calculating the effects of impacts leading to global catastrophes requires knowledge of the impact process at very large size scales. This information cannot be obtained directly but must be inferred from subscale physical simulations, numerical simulations, and scaling laws. Schmidt and Holsapple presented scaling laws based upon laboratory-scale impact experiments performed on a centrifuge (Schmidt, 1980 and Schmidt and Holsapple, 1980). These experiments were used to develop scaling laws which were among the first to include gravity dependence associated with increasing event size. At that time using the results of experiments in dry sand and in water to provide bounds on crater size, they recognized that more precise bounds on large-body impact crater formation could be obtained with additional centrifuge experiments conducted in other geological media. In that previous work, simple power-law formulae were developed to relate final crater diameter to impactor size and velocity. In addition, Schmidt (1980) and Holsapple and Schmidt (1982) recognized that the energy scaling exponent is not a universal constant but depends upon the target media. Recently, Holsapple and Schmidt (1987) includes results for non-porous materials and provides a basis for estimating crater formation kinematics and final crater size. A revised set of scaling relationships for all crater parameters of interest are presented. These include results for various target media and include the kinematics of formation. Particular attention is given to possible limits brought about by very large impactors.

Schmidt, Robert M.↗

The Science Goals of NASA's Exploration Initiative

The recently released policy directive, "A Renewed Spirit of Discovery: The President's Vision for U. S. Space Exploration," seeks to advance the U. S. scientific, security and economic interest through a program of space exploration which will robotically explore the solar system and extend human presence to the Moon, Mars and beyond. NASA's implementation of this vision will be guided by compelling questions of scientific and societal importance, including the origin of our Solar System and the search for life beyond Earth. The Exploration Roadmap identifies four key targets: the Moon, Mars, the outer Solar System, and extra-solar planets. First, a lunar investigation will set up exploration test beds, search for resources, and study the geological record of the early Solar System. Human missions to the Moon will serve as precursors for human missions to Mars and other destinations, but will also be driven by their support for furthering science. The second key target is the search for past and present water and life on Mars. Following on from discoveries by Spirit and Opportunity, by the end of the decade there will have been an additional rover, a lander and two orbiters studying Mars. These will set the stage for a sample return mission in 2013, increasingly complex robotic investigations, and an eventual human landing. The third key target is the study of underground oceans, biological chemistry, and their potential for life in the outer Solar System. Beginning with the arrival of Cassini at Saturn in July 2004 and a landing on Titan in 2006, the next decade will see an extended investigation of the Jupiter icy moons by a mission making use of Project Prometheus, a program to develop space nuclear power and nuclear-electric propulsion. Finally, the search for Earth-like planets and life includes a series of telescopic missions designed to find and characterize extra-solar planets and search them for evidence of life. These missions include HST and Spitzer, operating now; Kepler, SIM, JWST, and TPF, currently under development; and the vision missions, Life Finder and Planet Imager, which will possibly be constructed in space by astronauts.

Gardner, Jonathan P.↗

Path planning during combustion mode switch

Systems and methods are provided for transitioning between a first combustion mode and a second combustion mode in an internal combustion engine. A current operating point of the engine is identified and a target operating point for the internal combustion engine in the second combustion mode is also determined. A predefined optimized transition operating point is selected from memory. While operating in the first combustion mode, one or more engine actuator settings are adjusted to cause the operating point of the internal combustion engine to approach the selected optimized transition operating point. When the engine is operating at the selected optimized transition operating point, the combustion mode is switched from the first combustion mode to the second combustion mode. While operating in the second combustion mode, one or more engine actuator settings are adjusted to cause the operating point of the internal combustion to approach the target operating point.

42 ENGINEERING↗

Data-enabled structure–property mappings for lanthanide-activated inorganic scintillators

The use of machine learning (ML) models toward development of validated structure–property relationships for two fundamental properties of activated inorganic scintillators for high energy radiation detection, namely the light yield (LY) and the decay time constant, is explored. The ML models are built on easily accessible proxies of materials—interchangeably referred to as features, descriptors or fingerprints—that are carefully selected on the basis of a physical understanding of the scintillation mechanism. Our study indicates that the developed physics-based ML models employing kernel ridge regression (KRR) and AdaBoost algorithm applied on top of a decision tree-based regression are able to “learn” the underlying design rules in a multi-dimensional feature space and thereby enable reasonably accurate predictions of the two target properties on unseen compounds (i.e., on a held-out test set). For instance, within a set of twenty-five cerium- or europium-doped scintillator materials, our analysis reveals a strong correlation between the average ionic part of the dielectric constant and the LY, irrespective of the specific chemistry of the compounds, indicating that the average ionic part of the dielectric constant is a particularly relevant descriptor toward prediction of the LY. Our results also demonstrate that, despite the use of small training datasets, the developed models are able to quickly distinguish high performing chemistries from those with relatively poor performance and therefore can play a crucial role in screening of new compounds with an attractive combination of targeted properties. Finally, the present study provides necessary motivation for future efforts involving ML models with relatively large training datasets, vast feature space explorations, and experimental design in search of promising novel scintillator chemistries.

36 MATERIALS SCIENCE↗

Margin Evaluation in the Presence of Deformation, Rotation, and Translation in Prostate and Entire Seminal Vesicle Irradiation With Daily Marker-Based Setup Corrections

Purpose: To develop a method for margin evaluation accounting for all measured displacements during treatment of prostate cancer. Methods and Materials: For 21 patients treated with stereographic targeting marker-based online translation corrections, dose distributions with varying margins and gradients were created. Sets of possible cumulative delivered dose distributions were simulated by moving voxels and accumulating dose per voxel. Voxel motion was simulated consistent with measured distributions of systematic and random displacements due to stereographic targeting inaccuracies, deformation, rotation, and intrafraction motion. The method of simulation maintained measured correlation of voxel motions due to organ deformation. Results: For the clinical target volume including prostate and seminal vesicles (SV), the probability that some part receives <95% of the prescribed dose, the changes in minimum dose, and volume receiving 95% of prescription dose compared with planning were 80.5% {+-} 19.2%, 9.0 {+-} 6.8 Gy, and 3.0% {+-} 3.7%, respectively, for the smallest studied margins (3 mm prostate, 5 mm SV) and steepest dose gradients. Corresponding values for largest margins (5 mm prostate, 8 mm SV) with a clinical intensity-modulated radiotherapy dose distribution were 46.5% {+-} 34.7%, 6.7 {+-} 5.8 Gy, and 1.6% {+-} 2.3%. For prostate-only clinical target volume, the values were 51.8% {+-} 17.7%, 3.3 {+-} 1.6 Gy, and 0.6% {+-} 0.5% with the smallest margins and 5.2% {+-} 7.4%, 1.8 {+-} 0.9 Gy, and 0.1% {+-} 0.1% for the largest margins. Addition of three-dimensional rotation corrections only improved these values slightly. All rectal planning constraints were met in the actual reconstructed doses for all studied margins. Conclusion: We developed a system for margin validation in the presence of deformations. In our population, a 5-mm margin provided sufficient dosimetric coverage for the prostate. In contrast, an 8-mm SV margin was still insufficient owing to deformations. Addition of three-dimensional rotation corrections was of minor influence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

From the nucleus to the quarks.

The summary of this presentation is: (1) Tony and colleagues have had a profound influence on experimental nuclear physics; (2) Pion- and electron-deuteron scattering drove polarization technology; (3) Development of the polarization technology has been extraordinarily fruitful - HERMES, MIT-Bates, Novosibirsk, NIKHEF, JLab; (4) Latest internal target experiment: best evidence for 2-photon exchange; and (5) Scientific stage being set at JLab for d/u ratio measurement using polarization in isospin space: {sup 3}H/{sup 3}He.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dosimetric verification of surface and superficial doses for head and neck IMRT with different PTV shrinkage margins

Purpose: Dosimetric uncertainty in the surface and superficial regions is still a major concern for radiation therapy and becomes more important when using the inverse planning algorithm for IMRT. The purpose of this study was to measure dose distributions and to evaluate the calculation accuracy in the superficial region for different planning target volume (PTV) shrinkage methods for head and neck IMRT plans. Methods: A spherical polystyrene phantom 160 mm in diameter (ball phantom) was used to simulate the shape of the head. Strips of superflab bolus with thicknesses of 3.5 and 7.0 mm were spread on the surface of the ball phantom. Three sets of CT images were acquired for the ball phantom without and with the bolus. The hypothetical clinical target volume (CTV) and critical structures (spinal cord and parotid glands) were outlined on each set of CT images. The PTVs were initially created by expanding an isotropic 3 mm margin from the CTV and then margins of 0, 3, and 5 mm were shrunk from the phantom surface for dosimetric analysis. Seven-field IMRT plans with a prescribed dose of 180 cGy and same dose constraints were designed using an Eclipse treatment planning system. Superficial doses at depths of 0, 3.5, and 7.0 mm and at seven beam axis positions (gantry angles of 0 deg., 30 deg., 60 deg., 80 deg., 330 deg., 300 deg., and 280 deg.) were measured for each PTV shrinkage margin using 0.1 mm ultrathin thermoluminescent dosimeters. For each plan, the measured doses were compared to the calculated doses. Results: The PTV without shrinkage had the highest intensity and the steepest dose gradient in the superficial region. The mean measured doses for different positions at depths of 0, 3.5, and 7.0 mm were 106{+-}18, 185{+-}16, and 188{+-}12 cGy, respectively. For a PTV with 3 mm shrinkage, the mean measured doses were 94{+-}13, 183{+-}8, and 191{+-}8 cGy. For a PTV with 5 mm shrinkage, the mean measured doses were 86{+-}11, 173{+-}8, and 187{+-}5 cGy. The comparisons indicated that more than 73.3% of the calculated points are with doses lower than the measured points and the difference of the dose becomes more significant in the shallower region. At 7.0 mm depth, the average difference between calculations and measurements was 2.5% (maximum 5.5%). Conclusions: Application of the PTV shrinkage method should take into account the calculation inaccuracy, tumor coverage, and possible skin reaction. When the tumor does not invade the superficial region, an adequate shrinkage margin from the surface is helpful for reducing the skin reaction. As the tumor invades the superficial region, adding a bolus is a method better than only contouring PTV with skin inclusion.

60 APPLIED LIFE SCIENCES↗

The redshift distribution of cosmological samples: a forward modeling approach

Determining the redshift distribution n ( z ) of galaxy samples is essential for several cosmological probes including weak lensing. For imaging surveys, this is usually done using photometric redshifts estimated on an object-by-object basis. We present a new approach for directly measuring the global n ( z ) of cosmological galaxy samples, including uncertainties, using forward modeling. Our method relies on image simulations produced using \textsc(UFig) (Ultra Fast Image Generator) and on ABC (Approximate Bayesian Computation) within the MCCL (Monte-Carlo Control Loops) framework. The galaxy population is modeled using parametric forms for the luminosity functions, spectral energy distributions, sizes and radial profiles of both blue and red galaxies. We apply exactly the same analysis to the real data and to the simulated images, which also include instrumental and observational effects. By adjusting the parameters of the simulations, we derive a set of acceptable models that are statistically consistent with the data. We then apply the same cuts to the simulations that were used to construct the target galaxy sample in the real data. The redshifts of the galaxies in the resulting simulated samples yield a set of n ( z ) distributions for the acceptable models. We demonstrate the method by determining n ( z ) for a cosmic shear like galaxy sample from the 4-band Subaru Suprime-Cam data in the COSMOS field. We also complement this imaging data with a spectroscopic calibration sample from the VVDS survey. We compare our resulting posterior n ( z ) distributions to the one derived from photometric redshifts estimated using 36 photometric bands in COSMOS and find good agreement. This offers good prospects for applying our approach to current and future large imaging surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Feasibility of using cone-beam CT to verify and reposition the optically guided target localization of linear accelerator based stereotactic radiosurgery

Purpose: The optically guided target localization had been developed for linear accelerator based stereotactic radiosurgery (SRS). Unlike the traditional laser localization, the optical guided target localization utilizes a digital system to position patient. Although the system has been proven accurate and robust, it takes away the capability of physicist to directly double check the target position prior to irradiation. Any error from system calibration, data transformation, or head ring position maintenance will not be caught. The purpose of this work is to investigate the possibility of using cone-beam CT (CBCT) to double check the optically guided SRS target localization and reposition the patient. Methods: A SRS quality assurance (QA) phantom was used in the study. The phantom mounted with SRS head frame was scanned by computer tomography (CT) and planned according to the SRS radiation treatment planning process. A target isocenter is defined and transferred to the optically guided target localization system. The phantom was then transported to the linear accelerator room and localized at the initial position agreed by the optically guided target localization system and the CBCT system. Tests were conducted by moving/rotating the phantom to a set of preset offsets and taking CBCT images. Shifts detected by CBCT were compared with the preset offsets. Agreements between them were studied to see how well the CBCT was in discovering the optically guided target localization error. Results: Experiment results demonstrated good agreement between the CBCT detected phantom shift and the preset offset, when the offset is above 1 mm shift or 0.2 degree rotation. Offset less than 1 mm shift or 0.2 degree rotation was not detectable by CBCT. Conclusions: The study concludes that the CBCT is able to discover the optically guided target localization error due to the system calibration or had ring migration. It is a valuable second check tool for SRS target localization quality assurance. The accuracy of CBCT in estimating patient positioning deviation satisfies the SRS procedures with generous tumor size and margin that can tolerate 1 mm or 0.2 degree accuracy. This avoids sending patient home without treatment. CBCT can be neither used as a primary SRS target localization nor can it be used to reposition the patient that cannot tolerate 1 mm shift or 0.2 degree rotation.

60 APPLIED LIFE SCIENCES↗

SU-E-T-572: Normal Lung Tissue Sparing in Radiation Therapy for Locally Advanced Non-Small Cell Lung Cancer

Purpose: To compare normal lung-sparing capabilities of three advanced radiation therapy techniques for locally advanced non-small cell lung cancer (LA-NSCLC). Methods: Four-dimensional computed tomography (4DCT) was performed in 10 patients with stage IIIb LA-NSCLC. The internal target volume (ITV); planning target volume (PTV); and organs at risks (OARs) such as spinal cord, total normal lung, heart, and esophagus were delineated for each CT data set. Intensity-modulated radiation therapy (IMRT), Tomohelical-IMRT (TH-IMRT), and TomoDirect-IMRT (TD-IMRT) plans were generated (total prescribed dose, 66 Gy in 33 fractions to the PTV) for each patient. To reduce the normal lung dose, complete and directional block function was applied outside the normal lung far from the target for both TH-IMRT and TD-IMRT, while pseudo- OAR was set in the same region for IMRT. Dosimetric characteristics of the three plans were compared in terms of target coverage, the sparing capability for the OAR, and the normal tissue complication probability (NTCP). Beam delivery efficiency was also compared. Results: TH-IMRT and TD-IMRT provided better target coverage than IMRT plans. Lung volume receiving ≥–30 Gy, mean dose, and NTCP were significant with TH-IMRT than with IMRT (p=0.006), and volume receiving ≥20–30 Gy was lower in TD-IMRT than in IMRT (p<0.05). Compared with IMRT, TH-IMRT had better sparing effect on the spinal cord (Dmax, NTCP) and heart (V45) (p<0.05). NTCP for the spinal cord, V45 and V60 for the heart, and Dmax for the esophagus were significantly lower in TD-IMRT than in IMRT. The monitor units per fraction were clearly smaller for IMRT than for TH-IMRT and TD-IMRT (p=0.006). Conclusion: In LA-NSCLC, TH-IMRT gave superior PTV coverage and OAR sparing compared to IMRT. TH-IMRT provided better control of the lung volume receiving ≥5–30 Gy. The delivery time and monitor units were lower in TD-IMRT than in TH-IMRT.

61 RADIATION PROTECTION AND DOSIMETRY↗

A core of cell wall proteins functions in wall integrity responses in Arabidopsis thaliana

Abstract Cell walls surround all plant cells, and their composition and structure are tightly regulated to maintain cellular and organismal homeostasis. In response to wall damage, the cell wall integrity (CWI) system is engaged to ameliorate effects on plant growth. Despite the central role CWI plays in plant development, our current understanding of how this system functions at the molecular level is limited. Here, we investigated the transcriptomes of etiolated seedlings of mutants of Arabidopsis thaliana with defects in three major wall polysaccharides, pectin ( quasimodo2 ), cellulose ( cellulose synthase3 je5 ), and xyloglucan ( xyloglucan xylosyltransferase1 and 2 ), to probe whether changes in the expression of cell wall‐related genes occur and are similar or different when specific wall components are reduced or missing. Many changes occurred in the transcriptomes of pectin‐ and cellulose‐deficient plants, but fewer changes occurred in the transcriptomes of xyloglucan‐deficient plants. We hypothesize that this might be because pectins interact with other wall components and/or integrity sensors, whereas cellulose forms a major load‐bearing component of the wall; defects in either appear to trigger the expression of structural proteins to maintain wall cohesion in the absence of a major polysaccharide. This core set of genes functioning in CWI in plants represents an attractive target for future genetic engineering of robust and resilient cell walls.

59 BASIC BIOLOGICAL SCIENCES↗

Single Vocal Cord Irradiation: Image Guided Intensity Modulated Hypofractionated Radiation Therapy for T1a Glottic Cancer: Early Clinical Results

Purpose: To report, from a retrospective analysis of prospectively collected data, on the feasibility, outcome, toxicity, and voice-handicap index (VHI) of patients with T1a glottic cancer treated by a novel intensity modulated radiation therapy technique developed at our institution to treat only the involved vocal cord: single vocal cord irradiation (SVCI). Methods and Materials: Thirty patients with T1a glottic cancer were treated by means of SVCI. Dose prescription was set to 16 × 3.63 Gy (total dose 58.08 Gy). The clinical target volume was the entire vocal cord. Setup verification was done by means of an online correction protocol using cone beam computed tomography. Data for voice quality assessment were collected prospectively at baseline, end of treatment, and 4, 6, and 12 weeks and 6, 12, and 18 months after treatment using VHI questionnaires. Results: After a median follow-up of 30 months (range, 7-50 months), the 2-year local control and overall survival rates were 100% and 90% because no single local recurrence was reported and 3 patients died because of comorbidity. All patients have completed the intended treatment schedule; no treatment interruptions and no grade 3 acute toxicity were reported. Grade 2 acute dermatitis or dysphagia was reported in only 5 patients (17%). No serious late toxicity was reported; only 1 patient developed temporary grade 2 laryngeal edema, and responded to a short-course of corticosteroid. The VHI improved significantly, from 33.5 at baseline to 9.5 and 10 at 6 weeks and 18 months, respectively (P<.001). The control group, treated to the whole larynx, had comparable local control rates (92.2% vs 100%, P=.24) but more acute toxicity (66% vs 17%, P<.0001) and higher VHI scores (23.8 and 16.7 at 6 weeks and 18 months, respectively, P<.0001). Conclusion: Single vocal cord irradiation is feasible and resulted in maximal local control rate at 2 years. The deterioration in VHI scores was slight and temporary and subsequently improved to normal levels. Long-term follow-up is needed to consolidate these promising results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Pelvic Phantom for Modeling Internal Organ Motions

A pelvic phantom was developed for use in testing image-guided radiation therapy (IGRT) and adaptive applications in radiation therapy (ART) with simulating the anterior-posterior internal organ motions during prostate radiotherapy. Measurements could be done with an ionization chamber (IC) in the simulated prostate. The rectum was simulated by air-equivalent material (AEM). The volume superior to the IC placement was considered as the bladder. The extension of AEM volume could be varied. The vertical position of the IC placement could be shifted by {+-}1 cm to simulate the prostate motion parallel to the changes in bladder volume. The reality of the simulation was inspected. Three-millimeter-slice-increment computed tomography (CT) scans were taken for irradiation planning. The structure set was adapted to the phantom from a treated patient. Planning target volume was delineated according to the RTOG 0126 study. IMRT and 3D conformal radiation therapy (3D-CRT) plans were made. Prostate motion and rectum volume changes were simulated in the phantom. IC displacement was corrected by phantom shifting. The delivered dose was measured with IC in 7 cases using intensity-modulated radiation therapy (IMRT) and 3D-CRT fractions, and single square-shaped beams: anteroposterior (AP), posteroanterior (PA), and lateral (LAT). Variations from the calculated doses were slightly below 1% at IMRT and around 1% at 3D-CRT; below 4.5% at square AP beam; up to 9% at square PA beam; and around 0.5% at square LAT beam. Other authors have already shown that by using planning systems and ultrasonic and cone beam CT guidance, correction of organ motions in a real patient during prostate cancer IGRT does not have a significant dosimetric effect. The inspection of our phantom-as described here-ended with similar results. Our team suggested that our model is sufficiently realistic and can be used for IGRT and ART testing.

61 RADIATION PROTECTION AND DOSIMETRY↗

Performance evaluation of an energy tuning assembly for neutron spectral shaping

An energy tuning assembly (ETA) was designed here to be fielded at the National Ignition Facility (NIF) to modify the characteristic D-T fusion spectrum to include a prompt fission neutron spectral component. The ETA was characterized at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory to measure the shaped spectrum from an incident deuteron breakup neutron source, test the proposed neutron spectroscopy techniques used to inform the flux measurements at NIF, and validate the ability to predict ETA performance using a Monte Carlo Neutral Particle (MCNP) simulation. Activation foils (i.e., Ni, In, Au, Al) were exposed to a collimated 33-MeV deuteron-breakup beam originating from a tantalum breakup target. The source spectrum absent the ETA was characterized using a set of activation foils and the STAYSL unfolding code. Finally, the ETA-modified spectrum was obtained using activation foil unfolding with a χ 2 ν = 0 . 92 . The ETA-modified unfolded spectrum agreed with the MCNP-simulated prediction in the energy range of 0.1–14 MeV, but exhibited disagreements in the 10 eV–100 keV region. This work demonstrates shaping of the NIF neutron spectrum via the ETA to be a viable path forward for tailored neutron beams at NIF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A fitting algorithm for optimizing ion implantation energies and fluences

In this work we describe a method to automatically generate an ion implantation recipe, a set of energies and fluences, to produce a desired defect density profile in a solid using the fewest required energies. We simulate defect density profiles for a range of ion energies, fit them with an appropriate function, and interpolate to yield defect density profiles at arbitrary ion energies. Given Ν energies, we then optimize a set of Ν energy-fluence pairs to match a given target defect density profile. Finally, we find the minimum Ν such that the error between the target defect density profile and the defect density profile generated by the Ν energy-fluence pairs is less than a given threshold. Inspired by quantum sensing applications with nitrogen-vacancy centers in diamond, we apply our technique to calculate optimal ion implantation recipes to create uniform-density 1 μm surface layers of 15 N or vacancies (using 4 He).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Method Optimization for Sampling and Analysis Instrumentation

This work presents a generalized approach for analytical method optimization that branches the gap between techniques historically employed and accurate modern optimization techniques suitable for various applications. The novelty of the described strategy is the utilization of multivariate, multiobjective optimization with Karush-Kuhn-Tucker conditions to bound the optimization space to solutions within the physical limitations of instrumentation. Briefly, the basic steps outlined in this paper are to (1) determine the objective(s) that should be maximized or minimized based on the goals of the analytical application, (2) conduct a screening experiment, (3) perform ANOVA to determine the parameters which have a statistically significant effect on the objective, (4) conduct an experiment (e.g., Box-Behnken design) to collect data for fitting the objective equation, and (5) determine the physical constraints of the parameters and solve the Lagrangian to determine the optimal method parameters. A broad approach to optimization target selection allows for robust method tuning to develop improved data sets amenable for chemometrics and machine learning algorithm development. Gas chromatography-mass spectrometry was selected as a use case due to its broad use across scientific fields and time-consuming method development involving numerous parameters. In conclusion, this strategy can reduce the cost of research, improve data quality, and enable the rapid development of new analytical technique.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Discovery of Energy Storage Molecular Materials Using Quantum Chemistry-Guided Multiobjective Bayesian Optimization

Redox flow batteries (RFBs) are a promising technology for stationary energy storage applications due to their flexible design, scalability, and low cost. In RFBs, energy is carried in flowable redoxactive materials (redoxmers) which are stored externally and pumped to the cell during operation. Further improvements in the energy density of RFBs necessitates redoxmer designs with wider redox potential windows and higher solubility. Additionally, designing redoxmers with a fluorescence-enabled self-reporting functionality allows monitoring of the state of health of RFBs. To accelerate the discovery of redoxmers with desired properties, state-of-the- art machine learning ( ML) methods, such as multiobjective Bayesian optimization (MBO), are useful. Here, we first employed density functional theory calculations to generate a database of reduction potentials, solvation free energies, and absorption wavelengths for 1400 redoxmer molecules based on a 2,1,3-benzothiadiazole (BzNSN) core structure. From the computed properties, we identified 22 Pareto-optimal molecules that represent best trade-off among all of the desired properties. We further utilized these data to develop and benchmark an MBO approach to identify candidates quickly and efficiently with multiple targeted properties. With MBO, optimal candidates from the 1400-molecule data set can be identified at least 15 times more efficiently compared to the brute force or random selection approach. Importantly, we utilized this approach for discovering promising redoxmers from an unseen database of 1 million BzNSN-based molecules, where we discovered 16 new Pareto-optimal molecules with significant improvements in properties over the initial 1400 molecules. Furthermore, we anticipate that this active learning technique is general and can be utilized for the discovery of any class of functional materials that satisfies multiple desired property criteria.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gibbs Energy Minimization Model for Solvent Extraction with Application to Rare-Earths Recovery

The emergence of technologies in which rare-earth elements provide critical functionality has increased the demand for these materials, with important implications for supply security. Recycling provides an option for mitigating supply risk and for creating economic value from the resale of recovered materials. While solvent extraction is a proven technology for rare-earth recovery and separation, its application often requires extensive trial-and-error experimentation to estimate parameter values and determine experimental design configurations. We describe a modeling strategy based on Gibbs energy minimization that incorporates parameter estimation for required thermodynamic properties as well as process design for solvent extraction and illustrate its applicability to rare earths separation. Visualization analysis during parameter estimation revealed a linear relationship between the standard enthalpies of the extractant and respective organo-metal complexes, analogous to the additivity principle for predicting molar volumes of organic compounds. Establishing this relationship reduced the size of the parameter estimation problem and yielded good agreement between model predictions and reported equilibrium extraction data, validating the property estimates for the organic phase species. Design exploration and optimization results map the space of feasible solvent extraction column configurations and identify the set of optimal design parameter values that meet recovery and purity targets.

Critical materials↗