Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Using Convex Optimization to Efficiently Apportion Tracer and Pollutant Sources From Point Concentration Observations

Abstract Rivers transport elements, minerals, chemicals, and pollutants produced in their upstream basins. A sample from a river is a mixture of all of its upstream sources, making it challenging to pinpoint the contribution from each individual source. Here, we show how a nested sample design and convex optimization can be used to efficiently unmix downstream samples of a well‐mixed, conservative tracer in a steady state system into the contributions of their upstream sources. Our approach is significantly faster than previous methods. We represent the river's sub‐catchments, defined by sampling sites, using a directed acyclic graph. This graph is used to build a convex optimization problem which, thanks to its convexity, can be quickly solved to global optimality—in under a second on desktop hardware for data sets of ∼100 samples or fewer. Uncertainties in the upstream predictions can be generated using Monte Carlo resampling. We provide an open‐source implementation of this approach in Python. The inputs required are straightforward: a table containing sample locations and observed tracer concentrations, along with a D8 flow‐direction raster map. As a case study, we use this method to map the elemental geochemistry of sediment sources for rivers draining the Cairngorms mountains, UK. This method could be extended to non‐conservative and non‐steady state tracers. We also show, theoretically, how multiple tracers could be simultaneously inverted to recover upstream run‐off or erosion rates as well as source concentrations. Overall, this approach can provide valuable insights to researchers in various fields, including water quality, geochemical exploration, geochemistry, hydrology, and wastewater epidemiology.

Barnes, Richard↗

High Frequency Monitoring and Nitrate Sourcing Reveals Baseflow and Stormflow Controls on Total Dissolved Nitrogen and Carbon Export Along a Rural‐Urban Gradient

Abstract Efforts to reduce nitrogen and carbon loading from developed watersheds typically target specific flows or sources, but across gradients in development intensity there is no consensus on the contribution of different flows to total loading or sources of nitrogen export. This information is vital to optimize management strategies leveraging source reductions, stormwater controls, and restorations. We investigate how solute loading and sources vary across flows and land‐use using high frequency monitoring and stable nitrate isotope analysis from five catchments with different sanitary infrastructure, along a gradient in development intensity. High frequency monitoring allowed estimation of annual loading and attribution to storm versus baseflows. Nitrate loads were 16 kg/km 2 /yr. from the forested catchment and ranged from 68 to 119 kg/km 2 /yr., across developed catchments, highest for the septic served site. Across developed catchments, baseflow contributions ranged from 40% of N loading to 75% from the septic served catchment, and the contribution from high stormflows increased with development intensity. Stormflows mobilized and mixed many surface and subsurface nitrate sources while baseflow nitrate was dominated by fewer sources which varied by catchment (soil, wastewater, or fertilizer). To help inform future sampling designs, we demonstrate that grab sampling and targeted storm sampling would likely fail to accurately predict annual loadings within the study period. The dominant baseflow loads and subsurface stormflows are not treated by surface water management practices primarily targeted to surface stormflows. Using a balance of green and gray infrastructure and stream/riparian restoration may target specific flow paths and improve management.

Delesantro, Joseph M.↗

Near-infrared and gamma-ray monitoring of TANAMI gamma-ray bright sources

Context. We present that spectral energy distribution and its variability are basic tools for understanding the physical processes operating in active galactic nuclei (AGN). Aims. In this paper we report the results of a one-year near-infrared (NIR) and optical monitoring of a sample of 22 AGN known to be gamma-ray emitters, aimed at discovering correlations between optical and gamma-ray emission. Methods. We observed our objects with the Rapid Eye Mount (REM) telescope in J,H,K, and R bands nearly twice every month during their visibility window and derived light curves and spectral indexes. We also analyzed the gamma-ray data from the Fermi gamma-ray Space Telescope, making weekly averages. Results. Six sources were never detected during our monitoring, proving to be fainter than their historical Two micron all sky survey (2MASS) level. All of the sixteen detected sources showed marked flux density variability, while the spectral indexes remained unchanged within our sensitivity limits. Steeper sources showed, on average, a larger variability. From the NIR light curves we also computed a variability speed index for each detected source. Only one source (PKS 0208-512) underwent an NIR flare during our monitoring. Half of the sources showed a regular flux density trend on a one-year time scale, but do not show any other peculiar characteristic. The broadband spectral index α ro appears to be a good proxy of the NIR spectral index only for BL Lac objects. No clear correlation between NIR and gamma-ray data is evident in our data, save for PKS 0537-441, PKS 0521-360, PKS 2155-304, and PKS 1424-418. In conclusion, the gamma-ray/NIR flux ratio showed a large spread, QSO being generally gamma-louder than BL Lac, with a marked correlation with the estimated peak frequency (ν peak ) of the synchrotron emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Mini-conference on helicon plasma sources

The first two sessions of this mini-conference focused attention on two areas of helicon source research: The conditions for optimal helicon source performance and the origins of energetic electrons and ions in helicon source plasmas. The final mini-conference session reviewed novel applications of helicon sources, such as mixed plasma source systems and toroidal helicon sources. The session format was designed to stimulate debate and discussion, with considerable time available for extended discussion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A planar-type surface-wave plasma source with a subwavelength diffraction grating inclusion for large-area plasma applications

The electromagnetic wave through the subwavelength diffraction grating can be largely absorbed by surface-wave plasmas (SWPs). A SWP source is built with two slot-array antennas element. Due to the dissipation of surface waves in overdense plasmas, this source can provide remarkable discharge efficiency of 4.4 cm{sup 2}/W experimentally and 96% of incident power numerically. When the applied power as low as 200 W is supplied to the SWP source, a homogeneous plasma with the uniform area up to 14x36 cm{sup 2} and the plasma density up to 1.04x10{sup 18} m{sup -3} is generated under the quartz slab. By varying the incident power and gas pressure, the parameter of plasmas can be easily controlled without density jumping. Moreover, the characters of bi-Maxwellian electron energy distribution prove that our SWP source yield plasmas by surface heating actually. These excellent performances make the proposed source meet the requirements in large-area plasma processing and also give its advices for plasmas heating in next meter-size SWP sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An interchangeable-cathode vacuum arc plasma source

A simplified vacuum arc design [based on metal vapor vacuum arc (MeVVA) concepts] is employed as a plasma source for a study of a {sup 7}Be non-neutral plasma. The design includes a mechanism for interchanging the cathode source. Testing of the plasma source showed that it is capable of producing on the order of 10{sup 12} charges at confinable energies using a boron-carbide disk as the cathode target. The design is simplified from typical designs for lower energy and lower density applications by using only the trigger spark rather than the full vacuum arc in high current ion beam designs. The interchangeability of the cathode design gives the source the ability to replace only the source sample, simplifying use of radioactive materials in the plasma source. The sample can also be replaced with a completely different conductive material. The design can be easily modified for use in other plasma confinement or full MeVVA applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new magnetron based gas aggregation source of metal nanoclusters coupled to a double time-of-flight mass spectrometer system

A new magnetron based gas-aggregation source for continuous production of metal nanoclusters has been built and coupled to a double time-of-flight mass spectrometer system. The capability of the source to produce neutral, positive, and negative nanoclusters within one production cycle, particularly under the same optimized experimental conditions, has been tested. The source performs steadily for continuous long operations and has high beam intensity that would be preferable for size selective measurements in gas phase on individual nanoclusters. This paper describes on the instrumentation of the integrated complete experimental setup for gas-phase measurement on nanoclusters including the source. It reports on the production of copper nanoclusters using the source. Mass abundances of neutral and charged clusters have been investigated and the results are discussed with respect to reported results using various other types of sources. The experimental isotopic distributions of {sup 63}Cu versus {sup 65}Cu within individual cluster mass peaks have been derived and compared to corresponding theoretical profiles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Double-layer ion acceleration triggered by ion magnetization in expanding radiofrequency plasma sources

Ion energy distribution functions downstream of the source exit in magnetically expanding low-pressure plasmas are experimentally investigated for four source tube diameters ranging from about 5 to 15 cm. The magnetic-field threshold corresponding to a transition from a simple expanding plasma to a double layer-containing plasma is observed to increase with a decrease in the source tube diameter. The results demonstrate that for the four geometries, the double layer and the accelerated ion beam form when the ion Larmour radius in the source becomes smaller than the source tube radius, i.e., when the ions become magnetized in the source tube.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Li{sup +} ion emission from a hot-plate alumina-silicate source stimulated by flash heating with an infrared laser

The Neutralized Drift Compression Experiment-II accelerator under construction at Lawrence Berkeley National Laboratory has been designed to employ a lithium-doped alumino-silicate (Al-Si) hot-plate surface-ionization ion source. In order to achieve the design 1 mA/cm{sup 2} current density, the emitter must be constantly kept at a high temperature, leading to the accelerated loss of Li material as ions or neutrals. As a result, the estimated lifetime of the source is 50 h. This lifetime can be extended if the source is kept at low temperature during standby, and pulse heated to the high temperature during the ion extraction phase only. A pulsed heating technique based on an infrared laser (CO{sub 2} gas discharge, {lambda}= 10.6 {mu}m) is described in this paper. The feasibility of ion current emission stimulated by flash heating with an infrared (IR) laser was demonstrated. High repeatability of the laser-stimulated ion current was observed, creating an opportunity for modulation and gating of the ion current with a laser pulse. It was found that with the available low power ({approx_equal}115 W/cm{sup 2}) IR laser, current densities as high as 0.8 mA/cm{sup 2} could be achieved with a 2.8 mm diameter source. Various approaches for scaling to a larger (10 cm diameter) source and the application of short pulse, high power lasers are discussed. The results and conclusions of this paper may apply to various species of hot-plate ion sources.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characteristic of a triple-cathode vacuum arc plasma source

In order to generate a better ion beam, a triple-cathode vacuum arc plasma source has been developed. Three plasma generators in the vacuum arc plasma source are equally located on a circle. Each generator initiated by means of a high-voltage breakdown between the cathode and the anode could be operated separately or simultaneously. The arc plasma expands from the cathode spot region in vacuum. In order to study the behaviors of expanding plasma plume generated in the vacuum arc plasma source, a Langmuir probe array is employed to measure the saturated ion current of the vacuum arc plasma source. The time-dependence profiles of the saturated current density of the triple vacuum arc plasma source operated separately and simultaneously are given. Furthermore, the plasma characteristic of this vacuum arc plasma source is also presented in the paper.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

H- Ion Source Development for the FNAL 750keV Injector Upgrade

The new FNAL 750keV injector upgrade for the replacement of the 40 year old Fermi National Laboratory (FNAL) Cockcroft-Walton accelerators with a new ion source and 200MHz Radio Frequency Quadrupole (RFQ), Low Energy Beam Transport (LEBT) and Medium Energy Beam Transport (MEBT) [1], has been built and is now being tested prior to installation during the 2012 shutdown. The new H-' ion source is a round aperture magnetron which was developed at Brookhaven National Lab (BNL) by Jim Alessi[2]. Operational experience from BNL has shown that this type of source is more reliable with a longer lifetime (on the order of 6 to 9 months) due to better power efficiency. With a similar duty factor to BNL, we expect to have a comparable lifetime between source changes. The new source design reliably produces 90mA of H-' beam current at 15Hz rep-rate, 250mus pulse width, and a duty factor of 0.38%A The measured emittances at the end of the LEBT are horizontally H = 0.21I mm- mrad and vertically V = 0.17I mm- mrad. With 35kV extraction the power efficiency is 60mA/kW. The source design, along with data from a test stand and the LEBT, will be presented in this paper.

43 PARTICLE ACCELERATORS↗

Ways to improve the efficiency and reliability of radio frequency driven negative ion sources for fusion

Large RF driven negative hydrogen ion sources are being developed at IPP Garching for the future neutral beam injection system of ITER. The overall power efficiency of these sources is low, because for the RF power supply self-excited generators are utilized and the plasma is generated in small cylindrical sources (“drivers”) and expands into the source main volume. At IPP experiments to reduce the primary power and the RF power required for the plasma production are performed in two ways: The oscillator generator of the prototype source has been replaced by a transistorized RF transmitter and two alternative driver concepts, a spiral coil, in which the field is concentrated by ferrites, which omits the losses by plasma expansion and a helicon source are being tested.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A new coaxial high power microwave source based on dual beams

We present a new coaxial high power microwave source based on dual beams, which combines a relativistic backward wave oscillator (RBWO) (noted as the inner sub-source below) and a coaxial transit-time oscillator (TTO) (noted as the outer sub-source). The cathode consists of an inner and an outer annular cathode, which provides the inner and the outer annular electron beam for the sub-sources, respectively. Particle-in-cell (PIC) simulation results demonstrate that power conversion efficiencies of the two sub-sources with an identical frequency of 9.74 GHz are 29% and 25%, respectively. It is furthermore found that phase locking between the inner and the outer sub-sources can be realized, which suggests a feasibility to obtain a higher power output if the two microwave signals are coherently combined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulation of dose distribution for iridium-192 brachytherapy source type-H01 using MCNPX

Dosimetric data for a brachytherapy source should be known before it used for clinical treatment. Iridium-192 source type H01 was manufactured by PRR-BATAN aimed to brachytherapy is not yet known its dosimetric data. Radial dose function and anisotropic dose distribution are some primary keys in brachytherapy source. Dose distribution for Iridium-192 source type H01 was obtained from the dose calculation formalism recommended in the AAPM TG-43U1 report using MCNPX 2.6.0 Monte Carlo simulation code. To know the effect of cavity on Iridium-192 type H01 caused by manufacturing process, also calculated on Iridium-192 type H01 if without cavity. The result of calculation of radial dose function and anisotropic dose distribution for Iridium-192 source type H01 were compared with another model of Iridium-192 source.

61 RADIATION PROTECTION AND DOSIMETRY↗

A source of high-power pulses of elliptically polarized ultrawideband radiation

Here, we describe a source of high-power ultrawideband radiation with elliptical polarization. The source consisting of a monopolar pulse generator, a bipolar pulse former, and a helical antenna placed into a radioparent container may be used in tests for electromagnetic compatibility. In the source, the helical antenna with the number of turns N = 4 is excited with a high-voltage bipolar pulse. Preliminary, we examined helical antennas at a low-voltage source aiming to select an optimal N and to estimate a radiation center position and boundary of a far-field zone. Finally, characteristics of the source in the operating mode at a pulse repetition rate of 100 Hz are presented in the paper as well. Energy efficiency of the antenna is 0.75 at the axial ratio equal to 1.3. The effective potential of radiation of the source at the voltage amplitudes of the bipolar pulse generator equal to -175/+200 kV reaches 280 kV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A versatile, pulsed anion source utilizing plasma-entrainment: Characterization and applications

A novel pulsed anion source has been developed, using plasma entrainment into a supersonic expansion. A pulsed discharge source perpendicular to the main gas expansion greatly reduces unwanted “heating” of the main expansion, a major setback in many pulsed anion sources in use today. The design principles and construction information are described and several examples demonstrate the range of applicability of this anion source. Large OH{sup −}(Ar){sub n} clusters can be generated, with over 40 Ar solvating OH{sup −}. The solvation energy of OH{sup −}(Ar){sub n}, where n = 1-3, 7, 12, and 18, is derived from photoelectron spectroscopy and shows that by n = 12-18, each Ar is bound by about 10 meV. In addition, cis– and trans– HOCO{sup −} are generated through rational anion synthesis (OH{sup −} + CO + M → HOCO{sup −} + M) and the photoelectron spectra compared with previous results. These results, along with several further proof-of-principle experiments on solvation and transient anion synthesis, demonstrate the ability of this source to efficiently produce cold anions. With modifications to two standard General Valve assemblies and very little maintenance, this anion source provides a versatile and straightforward addition to a wide array of experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High average power, highly brilliant laser-produced plasma source for soft X-ray spectroscopy

In this work, a novel laser-produced plasma source is presented which delivers pulsed broadband soft X-radiation in the range between 100 and 1200 eV. The source was designed in view of long operating hours, high stability, and cost effectiveness. It relies on a rotating and translating metal target and achieves high stability through an on-line monitoring device using a four quadrant extreme ultraviolet diode in a pinhole camera arrangement. The source can be operated with three different laser pulse durations and various target materials and is equipped with two beamlines for simultaneous experiments. Characterization measurements are presented with special emphasis on the source position and emission stability of the source. As a first application, a near edge X-ray absorption fine structure measurement on a thin polyimide foil shows the potential of the source for soft X-ray spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental validation of the intrinsic spatial efficiency method over a wide range of sizes for cylindrical sources

The intrinsic spatial efficiency method is a new absolute method to determine the efficiency of a gamma spectroscopy system for any extended source. In the original work the method was experimentally demonstrated and validated for homogeneous cylindrical sources containing {sup 137}Cs, whose sizes varied over a small range (29.5 mm radius and 15.0 to 25.9 mm height). In this work we present an extension of the validation over a wide range of sizes. The dimensions of the cylindrical sources vary between 10 to 40 mm height and 8 to 30 mm radius. The cylindrical sources were prepared using the reference material IAEA-372, which had a specific activity of 11320 Bq/kg at july 2006. The obtained results were better for the sources with 29 mm radius showing relative bias lesser than 5% and for the sources with 10 mm height showing relative bias lesser than 6%. In comparison with the obtained results in the work where we present the method, the majority of these results show an excellent agreement.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗