Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Detection, Identification, Location, and Remote Sensing Using SAW RFID Sensor Tags

The Electromagnetic Systems Branch (EV4) of the Avionic Systems Division at NASA Johnson Space Center in Houston, TX is studying the utility of surface acoustic wave (SAW) radiofrequency identification (RFID) tags for multiple wireless applications including detection, identification, tracking, and remote sensing of objects on the lunar surface, monitoring of environmental test facilities, structural shape and health monitoring, and nondestructive test and evaluation of assets. For all of these applications, it is anticipated that the system utilized to interrogate the SAW RFID tags may need to operate at fairly long range and in the presence of considerable multipath and multiple-access interference. Towards that end, EV4 is developing a prototype SAW RFID wireless interrogation system for use in such environments called the Passive Adaptive RFID Sensor Equipment (PARSED) system. The system utilizes a digitally beam-formed planar receiving antenna array to extend range and provide direction-of-arrival information coupled with an approximate maximum-likelihood signal processing algorithm to provide near-optimal estimation of both range and temperature. The system is capable of forming a large number of beams within the field of view and resolving the information from several tags within each beam. The combination of both spatial and waveform discrimination provides the capability to track and monitor telemetry from a large number of objects appearing simultaneously within the field of view of the receiving array. In this paper, we will consider the application of the PARSEQ system to the problem of simultaneous detection, identification, localization, and temperature estimation for multiple objects. We will summarize the overall design of the PARSEQ system and present a detailed description of the design and performance of the signal detection and estimation algorithms incorporated in the system. The system is currently configured only to measure temperature (jointly with range and tag ID), but future versions will be revised to measure parameters other than temperature as SAW tags capable of interfacing with external sensors become available. It is anticipated that the estimation of arbitrary parameters measured using SAW-based sensors will be based on techniques very similar to the joint range and temperature estimation techniques described in this paper.

Barton, Richard J.↗

Comparison of Pyranometers and Reference Cells on Fixed and One-axis Tracking Surfaces

Photovoltaic (PV) system perfomance is monitored by a wide variety of sensors. These instruments range from secondary standard pyranometers to photodiode-based pyranometers to reference cells. Although instruments are mounted in the plane of array of the modules a wide range of results have been obtained. Some of these difference have been assumed to come from systematic uncertainties associated with the irradiance sensors. This study is an attempt to quantify these differences by comparing the output of selected thermopile-based pyranometers to photodiode-based pyranometers and reference cells on a horizontal surface, a fixed-tilt surface, and a one-axis tracking surface. This analysis focuses on clear-sky results from two sites with different climatic conditions. Several important features were observed. Photodiode-based pyranometers and reference cells produce widely different results under clear skies, especially at larger angles-of-incidence even though both instruments are based on measuring the short circuit current of solar cells. The difference is caused by the scattering of light as it passes through the glazing of the reference cell or the diffuser lens of the photodioded- base pyranometer. Both instruments are shown to have similar response to the spectral distribution of the irradiance when compared to the thermopile-based pyranometer that has a response nearly independent of the wavelength of light used by PV modules.

14 SOLAR ENERGY↗

Monolithic InGaAs JFET Active Pixel Tunable Image Sensor (MAPTIS)

A new Monolithic InGaAs Active Pixel Multispectral Image Sensor is described. This Infrared sensor will utilize high quality InGaAs grown by Molecular Beam Epitaxy on InP substrate for the fabrication of a high speed Junction Field Effect Transistor array.

hyper↗

Optical Characterization of the Keck Array and BICEP3 CMB Polarimeters from 2016 to 2019

The BICEP/Keck experiment (BK) is a series of small-aperture refracting telescopes observing degree-scale cosmic microwave background (CMB) polarization from the South Pole in search of a primordial B-mode signature. This B-mode signal arises from primordial gravitational waves interacting with the CMB and has amplitude parametrized by the tensor-to-scalar ratio r. Since 2016, BICEP3 and the Keck Array have been observing with 4800 total antenna-coupled transition-edge sensor detectors, with frequency bands spanning 95, 150, 220, and 270 GHz. Here we present the optical performance of these receivers from 2016 to 2019, including far-field beams measured in situ with an improved chopped thermal source and instrument spectral response measured with a field-deployable Fourier transform spectrometer. As a pair differencing experiment, an important systematic that must be controlled is the differential beam response between the co-located, orthogonally polarized detectors. We generate per-detector far-field beam maps and the corresponding differential beam mismatch that is used to estimate the temperature-to-polarization leakage in our CMB maps and to give feedback on detector and optics fabrication. The differential beam parameters presented here were estimated using improved low-level beam map analysis techniques, including efficient removal of non-Gaussian noise as well as improved spatial masking. These techniques help minimize systematic uncertainty in the beam analysis, with the goal of constraining the bias on r induced by temperature-to-polarization leakage to be subdominant to the statistical uncertainty. This is essential as we progress to higher detector counts in the next generation of CMB experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Aircraft-borne lightning sensor

An instrument is described that has been used to measure the spatial and temporal distributions of lightning strokes as seen from a high-altitude aircraft platform. It consists of two separate sensors. One has a lens, selectable filters, and a 50 x 50 element array of photodiodes. The second has an identical lens, filters, and a single detector that covers the same total field of view.

Wolfe, W. L.↗

Phase sensitive guidance sensor for wire-following vehicles

A guidance sensor for a wire-following vehicle which is phase sensitive, includes an array of coils positioned to sense the vertical component of a magnetic field produced by the ac current through the guidance wire. The outputs of the coils are fed to associated flip flops. Flip flops associated with coils, through which flux passes in one direction, e.g., up, are driven to one state, e.g., true, and flip flops associated with coils through which flux passes in the opposite direction, e.g., down, are driven to a false state. The control signal to guide the vehicle over the wire is a function of the number of flip flops in the true state. Circuitry is included to prevent flip flops from assuming a wrong state due to noise.

Hansen, G. R.↗

Growth in the Number of SSN Tracked Orbital Objects

The number of objects in earth orbit tracked by the US Space Surveillance Network (SSN) has experienced unprecedented growth since March, 2003. Approximately 2000 orbiting objects have been added to the "Analyst list" of tracked objects. This growth is primarily due to the resumption of full power/full time operation of the AN/FPS-108 Cobra Dane radar located on Shemya Island, AK. Cobra Dane is an L-band (23-cm wavelength) phased array radar which first became operational in 1977. Cobra Dane was a "Collateral Sensor" in the SSN until 1994 when its communication link with the Space Control Center (SCC) was closed. NASA and the Air Force conducted tests in 1999 using Cobra Dane to detect and track small debris. These tests confirmed that the radar was capable of detecting and maintaining orbits on objects as small as 5-cm diameter. Subsequently, Cobra Dane was reconnected to the SSN and resumed full power/full time space surveillance operations on March 4, 2003. This paper will examine the new data and its implications to the understanding of the orbital debris environment and orbital safety.

Stansbery, Eugene G.↗

Position sensor

A radiant energy angle sensor is provided wherein the sensitive portion thereof comprises a pair of linear array detectors with each detector mounted normal to the other to provide X and Y channels and a pair of slits spaced from the pair of linear arrays with each of the slits positioned normal to its associated linear array. There is also provided electrical circuit means connected to the pair of linear array detectors and to separate X and Y axes outputs.

Auer, Siegfried↗

Development of a TES-Based Anti-Coincidence Detector for Future X-ray Observatories

Microcalorimeters onboard future x-ray observatories require an anti-coincidence detector to remove environmental backgrounds. In order to most effectively integrate this anticoincidence detector with the main microcalorimeter array, both instruments should use similar read-out technology. The detectors used in the Cryogenic Dark Matter Search (CDMS) use a phonon measurement technique that is well suited for an anti-coincidence detector with a microcalorimeter array using SQUID readout. This technique works by using a transition-edge sensor (TES) connected to superconducting collection fins to measure the athermal phonon signal produced when an event occurs in the substrate crystal. Energy from the event propagates through the crystal to the superconducting collection fins, creating quasiparticles, which are then trapped as they enter the TES where they produce a signal. We are currently developing a prototype anti-coincidence detector for future x-ray missions and have recently fabricated test devices with Mo/Au TESs and Al collection fins. We will present results from the first tests of these devices which indicate a proof of concept that quasiparticle trapping is occurring in these materials.

Bailey, Catherine↗

MOS Circuitry Would Detect Low-Energy Charged Particles

Metal oxide semiconductor (MOS) circuits for measuring spatially varying intensities of beams of low-energy charged particles have been developed. These circuits are intended especially for use in measuring fluxes of ions with spatial resolution along the focal planes of mass spectrometers. Unlike prior mass spectrometer focal-plane detectors, these MOS circuits would not be based on ion-induced generation of electrons, and photons; instead, they would be based on direct detection of the electric charges of the ions. Hence, there would be no need for microchannel plates (for ion-to-electron conversion), phosphors (for electron-to-photon conversion), and photodetectors (for final detection) -- components that degrade spatial resolution and contribute to complexity and size. The developmental circuits are based on linear arrays of charge-coupled devices (CCDs) with associated readout circuitry (see figure). They resemble linear CCD photodetector arrays, except that instead of a photodetector, each pixel contains a capacitive charge sensor. The capacitor in each sensor comprises two electrodes (typically made of aluminum) separated by a layer of insulating material. The exposed electrode captures ions and accumulates their electric charges during signal-integration periods.

Sinha, Mahadeva↗

Development of a TES-Based Anti-Coincidence Detector for Future X-Ray Observations

Microcalorimeters onboard future x-ray observatories require an anticoincidence detector to remove environmental backgrounds. In order to most effectively integrate this anti-coincidence detector with the main microcalorimeter array, both instruments should use similar read-out technology. The detectors used in the Cryogenic Dark Matter Search (CDMS) use a phonon measurement technique that is well suited for an anti-coincidence detector with a microcalorimeter array using SQUID readout. This technique works by using a transition-edge sensor (TES) connected to superconducting collection fins to measure the athermal phonon signal produced when an event occurs in the substrate crystal. Energy from the event propagates through the crystal to the superconducting collection fins, creating quasiparticles, which are then trapped as they enter the TES where they produce a signal. We are currently developing a prototype anti-coincidence detector for future x-ray missions and have recently fabricated test devices with Mo/Au TESs and Al collection fins. We present results from the first tests of these devices which indicate a proof of concept that quasiparticle trapping is occurring in these materials.

Bailey, Catherine N.↗

Hot-Film and Hot-Wire Anemometry for a Boundary Layer Active Flow Control Test

Unsteady active flow control (AFC) has been used experimentally for many years to minimize bluff-body drag. This technology could significantly improve performance of rotorcraft by cleaning up flow separation. It is important, then, that new actuator technologies be studied for application to future vehicles. A boundary layer wind tunnel was constructed with a 1ft-x-3ft test section and unsteady measurement instrumentation to study how AFC manipulates the boundary layer to overcome adverse pressure gradients and flow separation. This unsteady flow control research requires unsteady measurement methods. In order to measure the boundary layer characteristics, both hot-wire and hot-film Constant Temperature Anemometry is used. A hot-wire probe is mounted in the flow to measure velocity while a hot-film array lays on the test surface to measure skin friction. Hot-film sensors are connected to an anemometer, a Wheatstone bridge circuit with an output that corresponds to the dynamic flow response. From this output, the time varying flow field, turbulence, and flow reversal can be characterized. Tuning the anemometers requires a fan test on the hot-film sensors to adjust each output. This is a delicate process as several variables drastically affect the data, including control resistance, signal input, trim, and gain settings.

Control Test↗

Cryogenic Selective Surfaces

There are many challenges involved in deep-space exploration, but several of these can be mitigated, or even solved, by the development of a coating that can reject most of the Sun's energy and yet still provide some far-infrared heat emission. Such a coating would allow non-heat-generating objects in space to reach cryogenic temperatures without using an active cooling system. This would be a benefit to deep-space sensors that require low temperatures, such as the James Webb Telescope focal plane array. It would also allow the use of superconductors in deep space, which could lead to magnetic energy storage rings, lossless power delivery, or perhaps a large-volume magnetic shield against galactic cosmic radiation. But perhaps the most significant enablement achieved from such a coating would be the long-term storage in deep space of cryogenic liquids, such as liquid oxygen (LOX).In this report, we review the state of the art in low-temperature coatings and calculate the lowest temperatures each of these can achieve, demonstrating that cryogenic temperatures cannot be reached in deep space in this fashion. We then propose a new coating that does allow coated objects in deep space to achieve the very low temperatures required to store liquid oxygen or nitrogen. These new coatings consist of a moderately thick scattering layer (typically 5 mm) composed of a material transparent to most of the solar spectrum. This layer acts as a scatterer to the Sun's light, performing the same process as titanium dioxide in white paint in the visible. Under that layer, we place a metallic reflector, e.g. silver, to reflect long-wave radiation that is not well scattered. The result is a coating we call "Solar White," in that it scatters most of the solar spectrum just as white paint does for the visible. Our modeling of these coatings has shown that temperatures as low as 50 K can be reached for a coated object fully exposed to sunlight at 1 AU from the Sun and far from the Earth.In the second half of the report we explore a mission application of this coating in order to show that it allows LOX to be carried on a mission to Mars. Heat can reach a LOX tank in five ways: direct radiation from the Sun, scattered or reflected radiation from the Sun off of spacecraft components, radiation from nearby planets or the Moon, radiation from the infrared emission of other parts of the spacecraft, and conduction along support struts and flow lines. We discuss these and sum their total contribution when using a Solar White coating to demonstrate an architecture that allows the transportation of LOX to Mars. After this, other applications of Solar White are listed.

Cryogenic Materials↗

Development of a Venus Surface Wind Sensor Based on a Miniature Drag-Force Anemometer

To better understand the atmospheric structure and dynamics on the Venus surface and provide input to climate models, there is a need to measure the wind velocity and direction on the surface and track changes over extended periods. A wind sensor based on a miniature drag-force anemometer is being developed to meet the challenges for wind measurements and operational requirements on the surface of Venus. The sensor materials are chosen to enhance durability and prevent reactivity with the Venus surface atmosphere. Advantages of this approach include that it is independent on variable heat transfer, has been matured in other harsh environment applications,and has a low mass and power requirement. This report describes demonstration of this miniature drag-force anemometer integrated with high temperature electronics in simulated Venus surface environment. Prototype drag-force anemometers were demonstrated integrated with an operational amplifier recording transient effects in a simulated Venus surface environment. For multidirectional wind monitoring, the sensors are small enough to be deployed orthogonally as a three-dimensional array on a small arm or mast

wind measurement↗

Development of a Venus Surface Wind Sensor

To better understand the atmospheric structure and dynamics on the Venus surface and provide input to climate models, there is a need to measure the wind velocity and direction on the surface and track changes over extended periods. A wind sensor based on a miniature drag-force anemometer is being developed to meet the challenges for wind measurements and operational requirements on the surface of Venus. The sensor materials are chosen to enhance durability and prevent reactivity with the Venus surface atmosphere. Advantages of this approach include that it is independent of variable heat transfer, has been matured in other harsh environment applications, and has a low mass and power requirement. Prototype drag-force anemometers were demonstrated, integrated with a high-temperature operational amplifier, recording transient effects in a simulated Venus surface environment. For multidirectional wind monitoring, the sensors are small enough to be deployed orthogonally as a three-dimensional array on a small arm or mast. This presentation describes the development and demonstration of this miniature drag-force anemometer integrated with high temperature electronics in a simulated Venus surface environment.

wind measurement↗

Imaging spectroscopy; Proceedings of the Seminar, Los Angeles, CA, February 10, 11, 1981

The seminar concentrated on the science applications of spectral imaging, multispectral imaging sensors, and spectral filtering. Papers are presented on spectroscopic remote sensing for geological applications, spectral mapping of Jupiter, system design of an interferometer imaging sounder and a common module imaging spectral radiometer. Other topics discussed include the performance and application of an intensified linear self-scanned array instrument, tunable optical filtering using an interferometer for selective modulation, design studies for a spectrally agile staring sensor system, and acousto-optic tunable filters for high-resolution spectral analysis.

Norris, D. D.↗

Dynamic Pupil Masking for Phasing Telescope Mirror Segments

A method that would notably include dynamic pupil masking has been proposed as an enhanced version of a prior method of phasing the segments of a primary telescope mirror. The method would apply, more specifically, to a primary telescope mirror that comprises multiple segments mounted on actuators that can be used to tilt the segments and translate them along the nominal optical axis to affect wavefront control in increments as fine as a fraction of a wavelength of light. An apparatus (see figure) for implementing the proposed method would be denoted a dispersed-fringe-sensor phasing camera system (DPCS). The prior method involves the use of a dispersed-fringe sensor (DFS). The prior method was reported as part of a more comprehensive method in Coarse Alignment of a Segmented Telescope Mirror (NPO-20770), NASA Tech Briefs, Vol. 25, No. 4 (April 2001), page 15a. The pertinent parts of the prior method are the following: The telescope would be aimed at a bright distant point source of light (e.g., a star) and form a broadband image on an imaging detector array placed at the telescope focal plane. The construction and use of a dispersed-fringe sensor would begin with insertion of a grism (a right-angle prism with a transmission grating on the hypotenuse face) into the optical path. With other segments tilted away from the investigating region of the detector, a dispersed-fringe image would be formed by use of a designated reference segment and a selected mirror segment. The modulation period and orientation of the fringe would be analyzed to determine the magnitude and sign of the piston error (displacement along the nominal optical axis) between the two segments. The error would be used to perform a coarse-phase piston adjustment of the affected mirror segment. This determination and removing of piston error is what is meant by phasing as used above. The procedure as described thus far would be repeated until all segments had been phased.

Shi, Fang↗

Multi-channel front-end ASIC for a 3D position-sensitive detector

Arrays of 3D position-sensitive detectors (3DPSD), operating at room temperature and using cadmium zinc telluride (CZT) and thallium bromide (TIBr) sensors, are suitable for gamma-ray spectrometry in many applications. One detector configuration, the 3D position-sensitive Virtual Frisch-Grid detector (VFG), is particularly advantageous for integrating into large area arrays. The signals generated inside each detector of the array are captured with the anode, cathode and four pads that enable the reconstruction of the position and energy of the ionizing interaction by measurements of amplitude and timing of the signals. For these applications, a low-noise front-end ASIC has been developed, capable of processing bipolar signals (needed because of AC-coupling of certain electrodes). The ASIC can be coupled to an ADC in order to form a compound “waveform digitizer” capable of post-processing the analog signals and determining amplitude and timing information. This paper describes a 32-channel front-end ASIC that is suitable for reading out a 3 × 3 or 4 × 4 element matrix in the VFG configuration. Each channel is composed of a low-noise charge amplifier with an adaptive continuous reset feedback circuit suitable for both positive and negative charge, a first order shaper and a single-to-differential converter output stage. Voltage and current references are all internally generated by 10-bit DACs and the chip is fully controllable with the I 2 C communication protocol. The readout channel response has been verified using the implemented injection circuit. Linear behavior up to ~75 ke ± with the gain of ~80 mV/fC, and up to ~200 ke ± with the gain of ~30 mV/fC was demonstrated. In conclusion, the first test result waveforms using a 137 Cs radioactive source on a 5 × 5 × 12 mm 3 TIBr crystal are reported.

47 OTHER INSTRUMENTATION↗