Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

A carbon nanotube based resettable sensor for measuring free chlorine in drinking water

Free chlorine from dissolved chlorine gas is widely used as a disinfectant for drinking water. The residual chlorine concentration has to be continuously monitored and accurately controlled in a certain range around 0.5–2 mg/l to ensure drinking water safety and quality. However, simple, reliable, and reagent free monitoring devices are currently not available. Here, we present a free chlorine sensor that uses oxidation of a phenyl-capped aniline tetramer (PCAT) to dope single wall carbon nanotubes (SWCNTs) and to change their resistance. The oxidation of PCAT by chlorine switches the PCAT-SWCNT system into a low resistance (p-doped) state which can be detected by probing it with a small voltage. The change in resistance is found to be proportional to the log-scale concentration of the free chlorine in the sample. The p-doping of the PCAT-SWCNT film then can be electrochemically reversed by polarizing it cathodically. This sensor not only shows good sensing response in the whole concentration range of free chlorine in drinking water but is also able to be electrochemically reset back many times without the use of any reagents. This simple sensor is ideally suited for measuring free chlorine in drinking water continuously.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A review on nanomechanical resonators and their applications in sensors and molecular transportation

Nanotechnology has opened a new area in science and engineering, leading to the development of novel nano-electromechanical systems such as nanoresonators with ultra-high resonant frequencies. The ultra-high-frequency resonators facilitate wide-ranging applications such as ultra-high sensitive sensing, molecular transportation, molecular separation, high-frequency signal processing, and biological imaging. This paper reviews recent studies on dynamic characteristics of nanoresonators. A variety of theoretical approaches, i.e., continuum modeling, molecular simulations, and multiscale methods, in modeling of nanoresonators are reviewed. The potential application of nanoresonators in design of sensor devices and molecular transportation systems is introduced. The essence of nanoresonator sensors for detection of atoms and molecules with vibration and wave propagation analyses is outlined. The sensitivity of the resonator sensors and their feasibility in detecting different atoms and molecules are particularly discussed. Furthermore, the applicability of molecular transportation using the propagation of mechanical waves in nanoresonators is presented. An extended application of the transportation methods for building nanofiltering systems with ultra-high selectivity is surveyed. The article aims to provide an up-to-date review on the mechanical properties and applications of nanoresonators, and inspire additional potential of the resonators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ethanol sensor based on nanocrystallite cadmium ferrite

The cadmium ferrite was synthesized by oxalate co-precipitation method. The crystal structure and surface morphology were examined by X-ray diffraction and SEM techniques, respectively. The nanocrystallite CdFe{sub 2}O{sub 4} sensor was tested for LPG, Cl{sub 2} and C{sub 2}H{sub 5}OH. The sensitivity was measured at various operating temperatures in the range of 100-400°C. The sensor shows highest sensitivity and selectivity to C{sub 2}H{sub 5}OH at 350°C. The response and recovery time was measured at operating temperature of 350°C. The sensor exhibits a lower response and recovery time for LPG and Cl{sub 2} as compared to ethanol.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ultra-sensitive Hall sensors based on graphene encapsulated in hexagonal boron nitride

The encapsulation of graphene in hexagonal boron nitride provides graphene on substrate with excellent material quality. Here, we present the fabrication and characterization of Hall sensor elements based on graphene boron nitride heterostructures, where we gain from high mobility and low charge carrier density at room temperature. We show a detailed device characterization including Hall effect measurements under vacuum and ambient conditions. We achieve a current- and voltage-related sensitivity of up to 5700 V/AT and 3 V/VT, respectively, outpacing state-of-the-art silicon and III/V Hall sensor devices. Finally, we extract a magnetic resolution limited by low frequency electric noise of less than 50 nT/√(Hz) making our graphene sensors highly interesting for industrial applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modeling the dark current histogram induced by gold contamination in complementary-metal-oxide-semiconductor image sensors

We propose a model for dark current induced by metallic contamination in a CMOS image sensor. Based on Shockley-Read-Hall kinetics, the expression of dark current proposed accounts for the electric field enhanced emission factor due to the Poole-Frenkel barrier lowering and phonon-assisted tunneling mechanisms. To that aim, we considered the distribution of the electric field magnitude and metal atoms in the depth of the pixel. Poisson statistics were used to estimate the random distribution of metal atoms in each pixel for a given contamination dose. Then, we performed a Monte-Carlo-based simulation for each pixel to set the number of metal atoms the pixel contained and the enhancement factor each atom underwent, and obtained a histogram of the number of pixels versus dark current for the full sensor. Excellent agreement with the dark current histogram measured on an ion-implanted gold-contaminated imager has been achieved, in particular, for the description of the distribution tails due to the pixel regions in which the contaminant atoms undergo a large electric field. The agreement remains very good when increasing the temperature by 15 °C. We demonstrated that the amplification of the dark current generated for the typical electric fields encountered in the CMOS image sensors, which depends on the nature of the metal contaminant, may become very large at high electric field. The electron and hole emissions and the resulting enhancement factor are described as a function of the trap characteristics, electric field, and temperature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Note: Improving long-term stability of hot-wire anemometer sensors by means of annealing

Annealing procedures for hot-wire sensors of platinum and platinum-plated tungsten have been investigated experimentally. It was discovered that the two investigated sensor metals behave quite differently during the annealing process, but for both types annealing may improve long-term stability considerably. Measured drift of sensors both without and with prior annealing is presented. Suggestions for suitable annealing temperatures and times are given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Properties of a weakly ionized NO gas sensor based on multi-walled carbon nanotubes

Nitric oxide NO is one of the major targets for environmental monitoring, but the existing NO sensors are limited by their low sensitivity and narrow test range. Here, a NO gas sensor employing multiwalled carbon nanotubes (MWCNTs) was fabricated, and its properties in NO–N{sub 2} mixture were investigated from both emission and ionization. The current I{sub e} passing through the nanotubes cathode was found to decrease with increasing NO concentration and increase linearly in different slopes with the extracting voltage U{sub e}. It is shown that the Schottky barrier of the MWCNTs calculated by I{sub e} increased with NO concentration due to the adsorption of NO gas, which restrained the electron emission and consequently weakened the ionization. The positive ion currents I{sub c} passing through the collecting electrode at different voltages of U{sub e} were found to monotonically decrease with increasing NO concentration, which was induced by both of the reduced electron emission and the consumption of the two excited metastable states N{sub 2}(A{sup 3}∑{sub u}{sup +}) and N{sub 2}(a′{sup 1}∑{sub u}{sup −}) by NO. The sensor exhibited high sensitivity at the low temperature of 30 °C. The calculated conductivity was found to be able to take place of I{sub c} for NO detection in a wide voltage range of 80–150 V U{sub e}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MoS{sub 2} oxygen sensor with gate voltage stress induced performance enhancement

Two-dimensional (2D) materials have recently attracted wide attention and rapidly established themselves in various applications. In particular, 2D materials are regarded as promising building blocks for gas sensors due to their high surface-to-volume ratio, ease in miniaturization, and flexibility in enabling wearable electronics. Compared with other 2D materials, MoS{sub 2} is particularly intriguing because it has been widely researched and exhibits semiconducting behavior. Here, we have fabricated MoS{sub 2} resistor based O{sub 2} sensors with a back gate configuration on a 285 nm SiO{sub 2}/Si substrate. The effects of applying back gate voltage stress on O{sub 2} sensing performance have been systematically investigated. With a positive gate voltage stress, the sensor response improves and the response is improved to 29.2% at O{sub 2} partial pressure of 9.9 × 10{sup −5} millibars with a +40 V back-gate bias compared to 21.2% at O{sub 2} partial pressure of 1.4 × 10{sup −4} millibars without back-gate bias; while under a negative gate voltage stress of −40 V, a fast and full recovery can be achieved at room temperature. In addition, a method in determining O{sub 2} partial pressure with a detectability as low as 6.7 × 10{sup −7} millibars at a constant vacuum pressure is presented and its potential as a vacuum gauge is briefly discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Significant manipulation of output performance of a bridge-structured spin valve magnetoresistance sensor via an electric field

Through principles of spin-valve giant magnetoresistance (SV-GMR) effect and its application in magnetic sensors, we have investigated electric-field control of the output performance of a bridge-structured Co/Cu/NiFe/IrMn SV-GMR sensor on a PZN-PT piezoelectric substrate using the micro-magnetic simulation. We centered on the influence of the variation of uniaxial magnetic anisotropy constant (K) of Co on the output of the bridge, and K was manipulated via the stress of Co, which is generated from the strain of a piezoelectric substrate under an electric field. The results indicate that when K varies between 2 × 10{sup 4 }J/m{sup 3} and 10 × 10{sup 4 }J/m{sup 3}, the output performance can be significantly manipulated: The linear range alters from between −330 Oe and 330 Oe to between −650 Oe and 650 Oe, and the sensitivity is tuned by almost 7 times, making it possible to measure magnetic fields with very different ranges. According to the converse piezoelectric effect, we have found that this variation of K can be realized by applying an electric field with the magnitude of about 2–20 kV/cm on a PZN-PT piezoelectric substrate, which is realistic in application. This result means that electric-control of SV-GMR effect has potential application in developing SV-GMR sensors with improved performance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compact all-fiber quartz-enhanced photoacoustic spectroscopy sensor with a 30.72 kHz quartz tuning fork and spatially resolved trace gas detection

An ultra compact all-fiber quartz-enhanced photoacoustic spectroscopy (QEPAS) sensor using quartz tuning fork (QTF) with a low resonance frequency of 30.72 kHz was demonstrated. Such a sensor architecture has the advantages of easier optical alignment, lower insertion loss, lower cost, and more compact compared with a conventional QEPAS sensor using discrete optical components for laser delivery and coupling to the QTF. A fiber beam splitter and three QTFs were employed to perform multi-point detection and demonstrated the potential of spatially resolved measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of microheaters for gas sensor with an AT-Mega 8535 temperature controller using a PWM (pulse width modulation) method

Microheater is the main component in gas sensor characterized by their sensitivity, selectivity, and time response of gas sensor which is depend on the microheater temperature stability. A Cu microheater was developed and utilized AT-Mega 8535 controller using a PWM (pulse width modulation) method. This control system is interfaced to the PC to observe the real time temperature response of the microheater. Three initial resistance (R0) variations of microheater were developed in an open loop control system. The power characteristic of designed microheater depends on the specified microheater initial resistance. The smaller R0, the less power required to reach a temperature setting value. The developed microheater was designed to reach a temperature setting value of 250°C having resistance 0.531 Ω for 1.979 Watt and 0.265 Ω for 1.072 Watt respectively. The results of the investigation on the control performances shows microheater-control system achieved operating temperature up to 250°C. The response of the temperature control shows smallest R0 resulted in a high stability with short settling time, short delay time and small ripple for temperature setting values higher than 150°C. The obtained error of microheater temperature with R0 = 0.265 is 8.596 %. It is concluded that the developed microheater can be utilized as a component of a gas sensor.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Indium oxide based fiber optic SPR sensor

Surface plasmon resonance based fiber optic sensor using indium oxide layer is presented and theoretically studied. It has been found that with increase in thickness of indium oxide layer beyond 170 nm, the sensitivity of SPR sensor decreases. 170 nm thick indium oxide layer based SPR sensor holds maximum sensitivity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enhanced and selective ammonia sensing of reduced graphene oxide based chemo resistive sensor at room temperature

The reduced graphene oxide thin films were fabricated by using the spin coating method. The reduced graphene oxide samples were characterised by Raman studies to obtain corresponding D and G bands at 1360 and 1590 cm{sup −1} respectively. Fourier transform infra-red (FTIR) spectra consists of peak corresponds to sp{sup 2} hybridisation of carbon atoms at 1560 cm{sup −1}. The reduced graphene oxide based chemoresistive sensor exhibited a p-type semiconductor behaviour in ambient conditions and showed good sensitivity to different concentration of ammonia from 25 ppm to 500 ppm and excellent selectivity at room temperature. The sensor displays selectivity to several hazardous vapours such as methanol, ethanol, acetone and hydrazine hydrate. The sensor demonstrated a sensitivity of 9.8 at 25 ppm concentration of ammonia with response time of 163 seconds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of metal oxide impregnated stilbite thick film ethanol sensor

This paper presents the study of the sensing efficiency of Titanium oxide/ Stilbite and Copper oxide /Stilbite composites towards detection of hazardous pollutants like ethanol. Stilbite based composites are prepared by physically mixing zeolite with metal oxides namely TiO{sub 2} and CuO with weight ratios of 25:75, 50:50 and 75:25. The resulting sensor materials are characterized by X-ray diffraction and Fourier Transform Infrared Spectroscopy techniques. Composite sensors are fabricated in the form of thick film by using screen printing technique. The effect of metal oxide concentration on various ethanol sensing parameters such as operating temperature, maximum uptake capacity and response/recovery time are investigated. The results indicate that metal oxide impregnated stilbite composites have great potential as low temperature ethanol sensor.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nano-imprint gold grating as refractive index sensor

Large scale of fabrication of plasmonic nanostructures has been a challenging task due to time consuming process and requirement of expensive nanofabrication tools such as electron beam lithography system, focused ion beam system, and extreme UV photolithography system. Here, we present a cost-effective fabrication technique so called soft nanoimprinting to fabricate nanostructures on the larger sample area. In our fabrication process, a commercially available optical DVD disc was used as a template which was imprinted on a polymer glass substrate to prepare 1D polymer nano-grating. A homemade nanoimprinting setup was used in this fabrication process. Further, a label-free refractive index sensor was developed by utilizing the properties of surface plasmon resonance (SPR) of a gold coated 1D polymer nano-grating. Refractive index sensing was tested by exposing different solutions of glycerol-water mixture on the surface of gold nano-grating. The calculated bulk refractive index sensitivity was found to be 751nm/RIU. We believed that our proposed SPR sensor could be a promising candidate for developing low-cost refractive index sensor with high sensitivity on a large scale.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Reducing the capacitance of piezoelectric film sensors

We present a novel design for large area, wideband, polymer piezoelectric sensor with low capacitance. The large area allows better spatial resolution in applications such as photoacoustic tomography and the reduced capacitance eases the design of fast transimpedance amplifiers. The metalized piezoelectric polymer thin film is segmented into N sections, electrically connected in series. In this way, the total capacitance is reduced by a factor 1/N{sup 2}, whereas the mechanical response and the active area of the sensor are not modified. We show the construction details for a two-section sensor, together with the impedance spectroscopy and impulse response experimental results that validate the design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-enzymatic glucose sensor based on electrodeposited copper on carbon paste electrode (Cu/CPE)

The development of non-enzymatic glucose sensor has much attention due to their applications in glucose monitoring. In this research, copper oxide is used as a non-enzymatic glucose sensor by oxidizing glucose to gluconolactone. Copper was electrodeposited on Carbon paste electrode (CPE) at constant potential. The experimental condition was varied in electrodeposition of Cu with the following parameters: Electrodeposition time 60 s, 120 s and 180 s and potential reduction -0.166 V, -0.266 V and -0.366 V. The effective performance of these working electrodes in sensing glucose was investigated. The Cu/CPE which used -0.366 V potential reduction and 120 s electrodeposition time shows the best performance. The amperometric response current in concentration range 1.6-62.5 mM of glucose gives the good linearity R{sup 2} = 0.9988, low detection limit 0.6728 mM and high sensitivity 1183.59 µA mM{sup −1}cm{sup −2}. Furthermore this sensor exhibited a good repeatability with %RSD = 1.31% (n=10) and high stability with %RSD = 1.51% (n=5 days). The homogeneity of Cu particles on CPE was investigated by Scanning Electron Microscope (SEM).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-speed imaging at high x-ray energy: CdTe sensors coupled to charge-integrating pixel array detectors

Pixel Array Detectors (PADs) consist of an x-ray sensor layer bonded pixel-by-pixel to an underlying readout chip. This approach allows both the sensor and the custom pixel electronics to be tailored independently to best match the x-ray imaging requirements. Here we describe the hybridization of CdTe sensors to two different charge-integrating readout chips, the Keck PAD and the Mixed-Mode PAD (MM-PAD), both developed previously in our laboratory. The charge-integrating architecture of each of these PADs extends the instantaneous counting rate by many orders of magnitude beyond that obtainable with photon counting architectures. The Keck PAD chip consists of rapid, 8-frame, in-pixel storage elements with framing periods <150 ns. The second detector, the MM-PAD, has an extended dynamic range by utilizing an in-pixel overflow counter coupled with charge removal circuitry activated at each overflow. This allows the recording of signals from the single-photon level to tens of millions of x-rays/pixel/frame while framing at 1 kHz. Both detector chips consist of a 128×128 pixel array with (150 µm){sup 2} pixels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗