Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Modular Automated Processing System (MAPS) for analysis of biological samples.

We have developed a novel modular automated processing system (MAPS) that enables reliable, high-throughput analysis as well as sample-customized processing. This system is comprised of a set of independent modules that carry out individual sample processing functions: cell lysis, protein concentration (based on hydrophobic, ion-exchange and affinity interactions), interferent depletion, buffer exchange, and enzymatic digestion of proteins of interest. Taking advantage of its unique capacity for enclosed processing of intact bioparticulates (viruses, spores) and complex serum samples, we have used MAPS for analysis of BSL1 and BSL2 samples to identify specific protein markers through integration with the portable microChemLab{trademark} and MALDI.

59 BASIC BIOLOGICAL SCIENCES↗

Stochastic sampling method with MCNPX for nuclear data uncertainty propagation in criticality safety applications

In the domain of criticality safety, the efficient propagation of uncertainty in nuclear data to uncertainty in k{sub eff} is an important area of current research. In this paper, a method based on stochastic sampling is presented for uncertainty propagation in MCNPX calculations. To that aim, the nuclear data (i.e. cross sections) are assumed to have a multivariate normal distribution and simple random sampling is performed following this presumed probability distribution. A verification of the developed stochastic sampling procedure with MCNPX is then conducted using the {sup 239}Pu Jezebel experiment as well as the PB-2 BWR and TMI-1 PWR pin cell models from the Uncertainty Analysis in Modeling (UAM) exercises. For the Jezebel case, it is found that the developed stochastic sampling approach predicts similar k{sub eff} uncertainties compared to conventional sensitivity and uncertainty methods. For the UAM models, slightly lower uncertainties are obtained when comparing to existing preliminary results. Further details of these verification studies are discussed and directions for future work are outlined. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Optimizing the implementation of the target motion sampling temperature treatment technique - How fast can it get?

This article discusses the optimization of the target motion sampling (TMS) temperature treatment method, previously implemented in the Monte Carlo reactor physics code Serpent 2. The TMS method was introduced in [1] and first practical results were presented at the PHYSOR 2012 conference [2]. The method is a stochastic method for taking the effect of thermal motion into account on-the-fly in a Monte Carlo neutron transport calculation. It is based on sampling the target velocities at collision sites and then utilizing the 0 K cross sections at target-at-rest frame for reaction sampling. The fact that the total cross section becomes a distributed quantity is handled using rejection sampling techniques. The original implementation of the TMS requires 2.0 times more CPU time in a PWR pin-cell case than a conventional Monte Carlo calculation relying on pre-broadened effective cross sections. In a HTGR case examined in this paper the overhead factor is as high as 3.6. By first changing from a multi-group to a continuous-energy implementation and then fine-tuning a parameter affecting the conservativity of the majorant cross section, it is possible to decrease the overhead factors to 1.4 and 2.3, respectively. Preliminary calculations are also made using a new and yet incomplete optimization method in which the temperature of the basis cross section is increased above 0 K. It seems that with the new approach it may be possible to decrease the factors even as low as 1.06 and 1.33, respectively, but its functionality has not yet been proven. Therefore, these performance measures should be considered preliminary. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Reducing Contingency through Sampling at the Luckey FUSRAP Site - 13186

Typically, the greatest risk in developing accurate cost estimates for the remediation of hazardous, toxic, and radioactive waste sites is the uncertainty in the estimated volume of contaminated media requiring remediation. Efforts to address this risk in the remediation cost estimate can result in large cost contingencies that are often considered unacceptable when budgeting for site cleanups. Such was the case for the Luckey Formerly Utilized Sites Remedial Action Program (FUSRAP) site near Luckey, Ohio, which had significant uncertainty surrounding the estimated volume of site soils contaminated with radium, uranium, thorium, beryllium, and lead. Funding provided by the American Recovery and Reinvestment Act (ARRA) allowed the U.S. Army Corps of Engineers (USACE) to conduct additional environmental sampling and analysis at the Luckey Site between November 2009 and April 2010, with the objective to further delineate the horizontal and vertical extent of contaminated soils in order to reduce the uncertainty in the soil volume estimate. Investigative work included radiological, geophysical, and topographic field surveys, subsurface borings, and soil sampling. Results from the investigative sampling were used in conjunction with Argonne National Laboratory's Bayesian Approaches for Adaptive Spatial Sampling (BAASS) software to update the contaminated soil volume estimate for the site. This updated volume estimate was then used to update the project cost-to-complete estimate using the USACE Cost and Schedule Risk Analysis process, which develops cost contingencies based on project risks. An investment of $1.1 M of ARRA funds for additional investigative work resulted in a reduction of 135,000 in-situ cubic meters (177,000 in-situ cubic yards) in the estimated base volume estimate. This refinement of the estimated soil volume resulted in a $64.3 M reduction in the estimated project cost-to-complete, through a reduction in the uncertainty in the contaminated soil volume estimate and the associated contingency costs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

On-Line Monitoring and Real-Time Characterization of Low Level Waste and Off-Gas Condensate Samples using Raman Spectroscopy - 19274

The demand for Hanford waste property analysis is expected to significantly increase as the U.S. Department of Energy River Protection Project progresses toward transferring waste to the Hanford Waste Treatment and Immobilization Plant. The analysis of waste includes chemical, radionuclide, and physical property characterizations, with the goal of achieving safe/informed transfer and processing. Waste sampling followed by offline laboratory analysis is the current baseline analytical approach. The addition of field-deployed/in situ instruments has the potential to provide improvements and benefits over offline analysis in the areas of 1) Worker Safety: by reducing the need for sampling and thereby reducing the need for worker interaction with waste during sample handling; 2) Operational Efficiency: by reducing analysis turnaround times and offsetting demand on analytical laboratories; and 3) Accuracy: continuous analysis of a flowing waste stream allows cumulative results to be produced for the batch, which is more representative than discrete samples of batch properties. This paper describes the development and application of an online monitor to provide chemical characterizations; specifically, Raman spectroscopy is utilized to identify and quantify tank components. Accurate quantification is achieved through the use of chemometric analysis, which can be configured to provide real-time analysis in field deployment settings. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

On‐Demand Ambient Ionization of Picoliter Samples Using Charge Pulses

Abstract Relay electrospray ionization (rESI) from a capillary containing a sample solution (or from an array of such capillaries) is triggered by charge deposition onto the capillary. Suitable sources of primary ions, besides electrosprays, are plasma ion and piezoelectric discharge plasma sources. With no requirement for physical contact, high‐throughput sample screening is enabled by rapidly addressing individual secondary (sample) capillaries. Sub‐pL sample volumes can be loaded and sprayed. Polar analytes, including neurotransmitters, phosphopeptides, oligonucleotides, illicit drugs, and pharmaceutical compounds are successfully ionized by rESI with concentration sensitivities (0.1 ppb for acetylcholine) which are similar to nanoESI but absolute sensitivities are orders of magnitude better. Nonpolar analytes (steroids, alkynes) are ionized by rESI using an open‐tube secondary capillary and injecting electrolytically generated metal cations from the primary electrospray.

Li, Anyin↗

On‐Demand Ambient Ionization of Picoliter Samples Using Charge Pulses

Abstract Relay electrospray ionization (rESI) from a capillary containing a sample solution (or from an array of such capillaries) is triggered by charge deposition onto the capillary. Suitable sources of primary ions, besides electrosprays, are plasma ion and piezoelectric discharge plasma sources. With no requirement for physical contact, high‐throughput sample screening is enabled by rapidly addressing individual secondary (sample) capillaries. Sub‐pL sample volumes can be loaded and sprayed. Polar analytes, including neurotransmitters, phosphopeptides, oligonucleotides, illicit drugs, and pharmaceutical compounds are successfully ionized by rESI with concentration sensitivities (0.1 ppb for acetylcholine) which are similar to nanoESI but absolute sensitivities are orders of magnitude better. Nonpolar analytes (steroids, alkynes) are ionized by rESI using an open‐tube secondary capillary and injecting electrolytically generated metal cations from the primary electrospray.

Li, Anyin↗

Effect of Sample Mass, Confinement, and Preheating Time on the Thermal Response of LLM‐105: Experiments and Kinetic Analysis

Various small-scale experiments were performed to provide data for developing a model to predict the thermal response of LLM-105 over a wide range of conditions. The thermal decomposition of LLM-105 was studied as a function of sample mass, confinement of volatile products, and preheating time in both isothermal and ramped heating experiments. The thermal decomposition of LLM-105 is a two-step process, as shown by the two exothermic peaks in the heat flow profiles, which were fitted to two nth-order autocatalytic reaction models with a similar activation energy of ∼289 kJ/mol. The magnitude and shape of these peaks varied with sample mass and confinement. Increasing sample mass enhanced the second exotherm with respect to the first one, while increasing the level of confinement promoted a transition from a sublimation-dominated regime towards thermal decomposition. The effect of LLM-105 particle size on the rate of weight loss was evident for open-pan experiments, where bigger particles sublimed at lower temperatures than smaller particles. Thermal response and solid residue composition of LLM-105 samples were analyzed following preheating for different durations. Longer preheating times caused a shift of the second exotherm to lower temperatures and a decrease in the reaction enthalpy, confirming that LLM-105 decay is a consecutive reaction mechanism, probably autocatalytic. In conclusion, the kinetic model derived from ramped experiments was validated against the measured LLM-105 fraction remaining and the enthalpy remaining of the solid residue as a function of preheating times and showed good agreement.

Chemistry - Chemical explosives↗

Depth profiling and standardization from the back side of a sample for accurate analyses: Emphasis on quantifying low‐fluence, shallow implants in diamond‐like carbon

Rationale Back‐side thinning of wafers is used to eliminate issues with transient sputtering when analyzing near‐surface element distributions. Precise and accurate calibrated implants are created by including a standard reference material during the implantation. Combining these methods allows accurate analysis of low‐fluence, shallow features even if matrix effects are a concern. Methods Implanted Na (<2.0 × 10 11 ions/cm 2 , peaking <50 nm) in diamond‐like carbon (DLC) film on silicon (solar wind returned by NASA's Genesis mission) was prepared for measurement as follows. Implanted surfaces of samples were epoxied to wafers and back‐side‐thinned using physical or chemical methods. Thinned samples were then implanted with reference ions for accurate quantification of the solar wind implant. Analyses used a CAMECA IMS 7f‐GEO SIMS in depth‐profiling mode. Results Back‐side‐implanted reference ions reduced the need to change sample mounts or stage position and could be spatially separated from the solar wind implant even when measuring monoisotopic ions. Matrix effects in DLC were mitigated and the need to find an identical piece of DLC for a reference implant was eliminated. Accuracy was only limited by the back‐side technique itself. Conclusions Combining back‐side depth profiling with back‐side‐implanted internal standards aides quantification of shallow mono‐ and polyisotopic implants. This technique helps mitigate matrix effects and keeps measurement conditions consistent. Depth profile acquisition times are longer, but if sample matrices are homogeneous, procedural changes can decrease measurement times.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Image Reconstruction from Under sampled Fourier Data Using the Polynomial Annihilation Transform

Fourier samples are collected in a variety of applications including magnetic resonance imaging and synthetic aperture radar. The data are typically under-sampled and noisy. In recent years, l 1 regularization has received considerable attention in designing image reconstruction algorithms from under-sampled and noisy Fourier data. The underlying image is assumed to have some sparsity features, that is, some measurable features of the image have sparse representation. The reconstruction algorithm is typically designed to solve a convex optimization problem, which consists of a fidelity term penalized by one or more l 1 regularization terms. The Split Bregman Algorithm provides a fast explicit solution for the case when TV is used for the l1l1 regularization terms. Due to its numerical efficiency, it has been widely adopted for a variety of applications. A well known drawback in using TV as an l 1 regularization term is that the reconstructed image will tend to default to a piecewise constant image. This issue has been addressed in several ways. Recently, the polynomial annihilation edge detection method was used to generate a higher order sparsifying transform, and was coined the “polynomial annihilation (PA) transform.” This paper adapts the Split Bregman Algorithm for the case when the PA transform is used as the l 1 regularization term. In so doing, we achieve a more accurate image reconstruction method from under-sampled and noisy Fourier data. Our new method compares favorably to the TV Split Bregman Algorithm, as well as to the popular TGV combined with shearlet approach.

97 MATHEMATICS AND COMPUTING↗

Synthesis and Characterization of Er-Doped Nano ZnO Samples

Pure and erbium-doped ZnO nanoparticles (Zn{sub 1−x}Er{sub x}O), (0.00 ≤ x ≤ 0.10), were synthesized by wet chemical co-precipitation method. The structural, optical, and magnetic properties of the prepared samples were investigated using x-ray powder diffraction (XRD), transmission electron microscopy (TEM), ultraviolet-visible spectroscopy (UV), Fourier transform infrared spectroscopy (FTIR), M-H magnetic hysteresis, and electron paramagnetic resonance (EPR). XRD studies exhibit the presence of a single ZnO wurtzite hexagonal crystal structure for 0.00 ≤ x ≤ 0.06. A secondary phase of Er{sub 2}O{sub 3} appears for x > 0.06. This means that the solubility limit for doping Zn{sup 2+} ions by Er{sup 3+} ions is about x = 0.06 under our preparations condition. The lattice parameter a is not affected by the Erbium doping. On the other hand, the lattice parameter c and the unit cell volume V increase with the increase of x up to x = 0.06. This is attributed to the larger ionic size of Er{sup 3+} ions (0.88 Å) compared to Zn{sup 2+} ions (0.74 Å). Both c and V decrease for x > 0.06. TEM micrographs indicate that the shape and the size of the ZnO nanoparticles are modified by changing the doping level of Er. The UV measurements point out that band gap energy E{sub g} decreases with the increase of x up to x = 0.06. Then, it increases for both x = 0.08 and 0.10. FTIR spectra confirm the presence of O–H and Zn–O stretching modes at 3451.963 and 428.901 cm{sup − 1}, respectively, in pure and doped ZnO samples. The Zn–O stretching mode shifts toward a lower wavenumber for x = 0.06 and toward a higher wavenumber for x = 0.10. M-H hysteresis analysis, at room temperature, reveals that the pure ZnO has a ferromagnetic signal combined with diamagnetic and paramagnetic contributions. This ferromagnetism is reduced for the doped samples up to x = 0.02, and an antiferromagnetic alignment appears for 0.04 ≤ x ≤ 0.10. The saturation magnetization (M{sub s}), the coercivity (H{sub c}), the retentivity (M{sub r}), the anisotropy constant (K{sub a}), and the magnetic moment (μ{sub m}) were estimated and discussed in terms of erbium doping for the different samples. EPR spectra for Zn{sub 1−x}Er{sub x}O were measured at room temperature in order to study the effect of Er substitution on the g value, resonance field (H{sub r}), peak to peak line width (ΔH{sub pp}) and spin–spin relaxation time constant (T{sub 2}).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Rapid method for the determination of 226Ra in hydraulic fracturing wastewater samples

A new method that rapidly preconcentrates and measures 226 Ra from hydraulic fracturing wastewater samples was developed in the Savannah River Environmental Laboratory. The method improves the quality of 226 Ra measurements using gamma spectrometry by providing up to 100x preconcentration of 226 Ra from this difficult sample matrix, which contains very high levels of calcium, barium, strontium, magnesium and sodium. The high chemical yield, typically 80-90%, facilitates a low detection limit, important for lower level samples, and indicates method ruggedness. Ba-133 tracer is used to determine chemical yield and correct for geometry-related counting issues. The 226 Ra sample preparation takes < 2 hours.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rapid method to determine 89 Sr/ 90 Sr in large concrete samples

Here, a new rapid method has been developed that provides high quality low-level measurements of 89,90 Sr in concrete samples with an MDA (Minimum Detectable Activity) of <1 mBq g -1 . The new method is fast, meets new decommissioning regulatory limits and is robust even if refractory particles are present. The method utilizes a rapid fusion to ensure total dissolution of samples and rapid preconcentration and separation of 89,90 Sr from 5-10 g concrete samples. When, the 89 Sr/ 90 Sr ratio is high, Sr can be isolated from up to 5g concrete samples, total 89/90 Sr measured, and then 90Sr determined via 90 Y separated after a period of ingrowth. Another approach allows the immediate determination of 90 Sr in 10 g concrete aliquots without waiting for 90 Y ingrowth, in instances where the shorter lived 89 Sr is unlikely to be encountered.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometry

The use of element isotope ratios has great potential in not only determining the reactor type used to produce plutonium (Pu) but also in determining the burnup and the time since irradiation. While a powerful nuclear forensic technique, determining element isotope ratios is complicated by severe isobaric interferences when performed on typical inductively coupled plasma mass spectrometers. Such analyses require extensive chemical separations prior to analysis to alleviate the inter-elemental isobars. Ultrahigh mass resolution spectrometry provides a potential alternative, greatly reducing the complexity of sample preparation and turnaround times for these critical measurements. To demonstrate the power of the approach, a sample of irradiated, depleted uranium was analyzed with the liquid sampling—atmospheric pressure glow discharge ion source coupled to an Orbitrap mass spectrometer. The Orbitrap is augmented with an external data acquisition system, Spectroswiss’s FTMS-Booster X2T, allowing collection of extended ion transients, providing higher mass resolution. In using this approach, the 150 Sm/ 149 Sm and 152 Sm/ 149 Sm isotope ratios were found to be within 20% of predicted values without any chemical separations and without mass bias corrections. In addition, the 240 Pu/ 239 Pu isotope ratio was determined, free from the 238 UH + interferences common to the ICP-MS platforms, while at the same time allowing for the determination of U isotopic signatures. While these demonstrative results are from a single sample, the advantages of the microplasma/ultrahigh mass resolution approach to intra-element isotope ratio determinations are clear.

Fuel burnup↗

A Feature-Based Stochastic Permeability of Shale: Part 1—Validation and Two-Phase Permeability in a Utica Shale Sample

Estimate of permeability plays a crucial role in flow-based studies of fractured tight-rocks. It is well known that most of the flow through tight-rocks (e.g., shales) is controlled by permeable features (e.g., fractures, laminations, etc.), and there is negligible flow through the matrix. However, current approaches in the literature to model permeability of tight-rocks do not account for such features present within the rock ranging from micro-scale to field-scale. Current permeability modeling approach assumes a single continuum without considering the presence of permeable features within the matrix (e.g., micro-fractures) or outside the matrix (e.g., natural fractures). Although the laboratory-measured permeability implicitly captures discrete features present in that sample (e.g., fractures, laminations, micro-fractures), most of the permeability models proposed for shale do not account for these features. Fracture permeability in the literature is typically modeled using an ideal slit assumption; however, this highly overestimates its permeability because fractures in real medium are non-ideal in terms of their porosity and tortuosity, which affect their permeability. Additionally, the transition zone between fracture and matrix also affects the permeability of fracture. Here in this study, part of a two-part series, a new method to predict permeability of fractured shale by discretizing the medium into matrix (inorganic and organic) and fractures is presented. New analytical expressions of permeability are derived to account for non-ideal nature of porous medium and two-phase flow in fractures. Rock feature in each cell of the grid is identified as one of the three elements (organic matter, inorganic matter, or fracture), and permeability of that cell is estimated using a suitable analytical expression. This method allows estimating permeability at any scale of interest and more robustly than by a pure analytical approach. The proposed method is validated against local and global-scale measurements on three fractured samples from laboratory. Finally, the method is used to predict two-phase flow permeability of supercritical CO 2 displacing water within a fracture in a Utica shale sample. The proposed two-phase flow permeability equations can be used as a quick analytical tool to predict relative permeability estimates of two-phase flow in fractured shale samples. In Part 2, the proposed method is used to estimate field-scale permeability through an optimization process that uses field-scale production and other readily available information.

58 GEOSCIENCES↗

Effects of Coatings on the High-Cycle Fatigue Life of Threaded Steel Samples

In this work, high-cycle fatigue is studied for threaded cylindrical high-strength steel samples coated using three different industrial processes: black oxidation, normal-temperature galvanization and high-temperature galvanization. The fatigue performance in air is compared with that of uncoated samples. Microstructural characterization revealed the abundant presence of small cracks in the zinc coating partially penetrating into the steel. This is consistent with the observation of multiple crack initiation sites along the thread in the galvanized samples, which led to crescent type fracture surfaces governed by circumferential growth. In contrast, the black oxidized and uncoated samples exhibited a semicircular segment type fracture surface governed by single-sided growth with a significantly longer fatigue life. Numerical fatigue life prediction based on an extended Paris-law formulation has been conducted on two different fracture cases: 2D axisymmetric multisided crack growth and 3D single-sided crack growth. The results of this upper-bound and lower-bound approach are in good agreement with experimental data and can potentially be used to predict the lifetime of bolted components.

36 MATERIALS SCIENCE↗

Investigation and Applications of In-Source Oxidation in Liquid Sampling-Atmospheric Pressure Afterglow Microplasma Ionization (LS-APAG) Source

A liquid sampling-atmospheric pressure afterglow microplasma ionization (LS-APAG) source is presented for the first time, which is embedded with both electrospray ionization (ESI) and atmospheric pressure afterglow microplasma ionization (APAG) techniques. This ion source is capable of analyzing compounds with diverse molecule weights and polarities. An unseparated mixture sample was detected as a proof-of-concept, giving complementary information (both polarities and non-polarities) with the two ionization modes. It should also be noted that molecular mass can be quickly identified by ESI with clean and simple spectra, while the structure can be directly studied using APAG with in-source oxidation. The ionization/oxidation mechanism and applications of the LS-APAG source have been further explored in the analysis of nonpolar alkanes and unsaturated fatty acids/esters. A unique [M + O – 3H]{sup +} was observed in the case of individual alkanes (C{sub 5}–C{sub 19}) and complex hydrocarbons mixture under optimized conditions. Moreover, branched alkanes generated significant in-source fragments, which could be further applied to the discrimination of isomeric alkanes. The technique also facilitates facile determination of double bond positions in unsaturated fatty acids/esters due to diagnostic fragments (the acid/ester-containing aldehyde and acid oxidation products) generated by on-line ozonolysis in APAG mode. Finally, some examples of in situ APAG analysis by gas sampling and surface sampling were given as well. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Fibrinogen-Specific Sandwich Enzyme-Linked Immunosorbent Assay Microarray Assay for Distinguishing Between Blood Plasma and Serum Samples

We have developed a fibrinogen-specific sandwich ELISA microarray assay for use in qualitatively distinguishing between blood plasma and serum samples. Three capture antibodies, 49D2, HPA001900, and F8512, were evaluated in conjunction with 1D6 as detection antibody, and the data show that 49D2 and, to a lesser extent, F8512 successfully identify previously unknown plasma and serum samples based upon a ~28-fold difference in signal intensity between the sample types. This assay has utility in rapidly identifying previously archived clinical samples with incomplete annotation in a high throughput manner prior to proteomics analyses.

60 APPLIED LIFE SCIENCES↗