A Statistical Analysis of the Economic Drivers of Battery Energy Storage in Commercial Buildings: Preprint

There is significant interest in using battery energy storage systems (BESS) to reduce peak demand charges, and therefore the life cycle cost of electricity, in commercial buildings. This paper explores the drivers of economic viability of BESS in commercial buildings through statistical analysis. A sample population of buildings was generated, a techno-economic optimization model was used to size and dispatch the BESS, and the resulting optimal BESS sizes were analyzed for relevant predictor variables. Explanatory regression analyses were used to demonstrate that peak demand charges are the most significant predictor of an economically viable battery, and that the shape of the load profile is the most significant predictor of the size of the battery.

25 ENERGY STORAGE↗

Predictors of Local Recurrence After Rituximab-Based Chemotherapy Alone in Stage III and IV Diffuse Large B-Cell Lymphoma: Guiding Decisions for Consolidative Radiation

Purpose: The role of consolidative radiation therapy (RT) for stage III and IV diffuse large B-cell lymphoma (DLBCL) in the era of rituximab is not well defined. There is evidence that some patients with bulky disease may benefit, but patient selection criteria are not well established. We sought to identify a subset of patients who experienced a high local failure rate after receiving rituximab-based chemotherapy alone and hence may benefit from the addition of consolidative RT. Methods and Materials: Two hundred eleven patients with stage III and IV DLBCL treated between August 1999 and January 2012 were reviewed. Of these, 89 had a complete response to systemic therapy including rituximab and received no initial RT. Kaplan-Meier analysis and Cox proportional hazards regression were performed, with local recurrence (LR) as the primary outcome. Results: The median follow-up time was 43.9 months. Fifty percent of patients experienced LR at 5 years. In multivariate analysis, tumor ≥5 cm and stage III disease were associated with increased risk of LR. The 5-year LR-free survival was 47.4% for patients with ≥5-cm lesions versus 74.7% for patients with <5-cm lesions (P=.01). In patients with <5-cm tumors, the maximum standardized uptake value (SUVmax) was ≥15 in all patients with LR. The 5-year LR-free survival was 100% in SUV<15 versus 68.8% in SUV≥15 (P=.10). Conclusions: Advanced-stage DLBCL patients with stage III disease or with disease ≥5 cm appear to be at an increased risk for LR. Patients with <5-cm disease and SUVmax ≥15 may be at higher risk for LR. These patients may benefit from consolidative RT after chemoimmunotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Engine With Regression and Neural Network Approximators Designed

At the NASA Glenn Research Center, the NASA engine performance program (NEPP, ref. 1) and the design optimization testbed COMETBOARDS (ref. 2) with regression and neural network analysis-approximators have been coupled to obtain a preliminary engine design methodology. The solution to a high-bypass-ratio subsonic waverotor-topped turbofan engine, which is shown in the preceding figure, was obtained by the simulation depicted in the following figure. This engine is made of 16 components mounted on two shafts with 21 flow stations. The engine is designed for a flight envelope with 47 operating points. The design optimization utilized both neural network and regression approximations, along with the cascade strategy (ref. 3). The cascade used three algorithms in sequence: the method of feasible directions, the sequence of unconstrained minimizations technique, and sequential quadratic programming. The normalized optimum thrusts obtained by the three methods are shown in the following figure: the cascade algorithm with regression approximation is represented by a triangle, a circle is shown for the neural network solution, and a solid line indicates original NEPP results. The solutions obtained from both approximate methods lie within one standard deviation of the benchmark solution for each operating point. The simulation improved the maximum thrust by 5 percent. The performance of the linear regression and neural network methods as alternate engine analyzers was found to be satisfactory for the analysis and operation optimization of air-breathing propulsion engines (ref. 4).

Patnaik, Surya N.↗

Simultaneous Integrated Boost Irradiation After Breast-Conserving Surgery: Physician-Rated Toxicity and Cosmetic Outcome at 30 Months' Follow-Up

Purpose: To evaluate toxicity and cosmetic outcome (CO) in breast cancer survivors treated with three-dimensional conformal radiotherapy with a hypofractionated, simultaneous integrated boost (3D-CRT-SIB) and to identify risk factors for toxicity, with special focus on the impact of age. Methods and Materials: Included were 940 consecutive disease-free patients treated for breast cancer (Stage 0-III) with 3D-CRT-SIB, after breast-conserving surgery, from 2005 to 2010. Physician-rated toxicity (Common Terminology Criteria for Adverse Events version 3.0) and CO were prospectively assessed during yearly follow-up, up to 5 years after radiotherapy. Multivariate logistic regression analyses using a bootstrapping method were performed. Results: At 3 years, toxicity scores of 436 patients were available. Grade {>=}2 fibrosis in the boost area was observed in 8.5%, non-boost fibrosis in 49.4%, pain to the chest wall in 6.7%, and fair/poor CO in 39.7% of cases. Radiotherapy before chemotherapy was significantly associated with grade {>=}2 boost fibrosis at 3 years (odds ratio [OR] 2.8, 95% confidence interval [CI] 1.3-6.0). Non-boost fibrosis was associated with re-resection (OR 2.2, 95% CI 1.2-4.0) and larger tumors (OR 1.1, 95% CI 1.0-1.1). At 1 year, chest wall pain was significantly associated with high boost dosage (OR 2.1, 95% CI 1.2-3.7) and younger age (OR 0.4, 95% CI 0.2-0.7). A fair/poor CO was observed more often after re-resection (OR 4.5, 95% CI 2.4-8.5), after regional radiotherapy (OR 2.9, 95% CI 1.2-7.1), and in larger tumors (OR 1.1, 95% CI 1.0-1.1). Conclusions: Toxicity and CO are not impaired after 3D-CRT-SIB. Fibrosis was not significantly associated with radiotherapy parameters. Independent risk factors for fibrosis were chemotherapy after radiotherapy, re-resection, and larger tumor size. Re-resection was most predictive for worse CO. Age had an impact on chest wall pain occurrence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantifying and Reducing Curve-Fitting Uncertainty in Isc: Preprint

Current-voltage (I-V) curve measurements of photovoltaic (PV) devices are used to determine performance parameters and to establish traceable calibration chains. Measurement standards specify localized curve fitting methods, e.g., straight-line interpolation/extrapolation of the I-V curve points near short-circuit current, Isc. By considering such fits as statistical linear regressions, uncertainties in the performance parameters are readily quantified. However, the legitimacy of such a computed uncertainty requires that the model be a valid (local) representation of the I-V curve and that the noise be sufficiently well characterized. Using more data points often has the advantage of lowering the uncertainty. However, more data points can make the uncertainty in the fit arbitrarily small, and this fit uncertainty misses the dominant residual uncertainty due to so-called model discrepancy. Using objective Bayesian linear regression for straight-line fits for Isc, we investigate an evidence-based method to automatically choose data windows of I-V points with reduced model discrepancy. We also investigate noise effects. Uncertainties, aligned with the Guide to the Expression of Uncertainty in Measurement (GUM), are quantified throughout.

14 SOLAR ENERGY↗

GRCop-84 Developed for Rocket Engines

GRCop-84 (Cu-8 at.% Cr-4 at.% Nb) was developed at the NASA Glenn Research Center for use in regeneratively cooled rocket engines. This alloy possesses an excellent combination of conductivity, thermal expansion, strength, creep resistance, ductility, and low-cycle fatigue (LCF) life. In comparison to the currently used alloy, NARloy-Z (Cu-3 wt % Ag-0.5 wt % Zr), GRCop-84's significantly better properties give it the potential for significant gains in engine performance and reliability. For GRCop-84 to be safely used in a rocket engine, it is critical to develop a detailed data base of the important thermophysical and mechanical properties. Work has focused on five major properties: thermal conductivity, thermal expansion, tensile strength, creep resistance, and LCF life. The analysis went beyond simply measuring the data and reporting averages. A detailed statistical analysis was conducted that allowed regression of the data over the entire temperature range tested and establishment of design minimums. The design values were expressed as simple mathematical formulas that are highly amenable to use in computer codes such as in finite element analysis and related computer modeling work.

Ellis, David L.↗

Rate expressions and kinetic parameters for metal ferrites in relation to applications of fossil fuel conversion to hydrogen: Part 1 of 2

Here, the goal of the present work was to provide the necessary reaction emulation information to enable detailed process simulation of a chemical looping H 2 production system from fossil fuels using CaFe 2 O 4 . This specifically pertained to the necessary kinetic data, reaction model development, and model rate parameters required for reaction emulation in both reducing and oxidizing environments. A logical methodology was defined, which included discretization of the reaction network, establishing a core model for reaction emulation that could be adapted based on the system phenomena, and development of a rate parameter regression tool designed around the core model. An extensive array of data sets was acquired by which parametric regressions were performed. The work presented and tabulated a comprehensive set of rate parameters for the reduction and oxidation reactions of CaFe 2 O 4 and descendent phases of Ca 2 Fe 2 O 5 , FeO, Fe 3 O 4 , Fe, and CaO to emulate reaction behavior in a looping-based process environment. This included direct reduction using CH 4 , H 2 , and CO, and direct oxidation reactions with steam, CO 2 and O 2 . Dynamic equilibrium was quantified for reactions that could utilize H 2 O and CO 2 as soft oxidants to re-saturate lattice oxygen in the depleted structure/phases. The kinetics associated with the oxidative mechanisms with the soft oxidants were quantified and compared to those of the reducing counterparts. The analysis provided critical insight to emulate reactions for a process that seeks to use natural gas (NG) or other fossil fuels as a direct reductant for the end goal of H 2 production.

calcium ferrite oxygen carriers↗

NASA's X-Plane Database and Parametric Cost Model v 2.0

The NASA Armstrong Cost Engineering Team with technical assistance from NASA HQ (SID)has gone through the full process in developing new CERs from Version #1 to Version #2 CERs. We took a step backward and reexamined all of the data collected, such as dependent and independent variables, cost, dry weight, length, wingspan, manned versus unmanned, altitude, Mach number, thrust, and skin. We used a well- known statistical analysis tool called CO$TAT instead of using "R" multiple linear or the "Regression" tool found in Microsoft Excel(TradeMark). We setup an "array of data" by adding 21" dummy variables;" we analyzed the standard error (SE) and then determined the "best fit." We have parametrically priced-out several future X-planes and compared our results to those of other resources. More work needs to be done in getting "accurate and traceable cost data" from historical X-plane records!

life cycle cost↗

An analysis of mesoscale VAS retrievals using statistical structure functions

Mesoscale sounding data from a truth rawinsonde network and a VAS from March 6-7, 1982 are statistically studied. The parameters of temperature, geopotential height, and mixing ratio at 850, 700, 500, 300, and 200 mb levels, and thickness and precipitable water are examined. The VAS retrieval gradients derived from a physical algorithm and from a regression technique are analyzed; the analysis reveals that both techniques have similar error characteristics and capabilities for calculating gradients of mesoscale temperature and geopotential height. Ground-truth rawinsonde data and VAS retrievals are compared; it is observed that VAS data describes weaker gradients than rawinsonde data.

Fuelberg, H. E.↗

Multivariate analysis of gamma spectra to characterize used nuclear fuel

Abstract—The Multi-Isotope Process (MIP) Monitor provides an efficient approach to monitoring the process conditions in used nuclear fuel reprocessing facilities to support process verification and validation. The MIP Monitor applies multivariate analysis to gamma spectroscopy of reprocessing streams in order to detect small changes in the gamma spectrum, which may indicate changes in process conditions. This research extends the MIP Monitor by characterizing a used fuel sample after initial dissolution according to the type of reactor of origin (pressurized or boiling water reactor), initial enrichment, burn up, and cooling time. Simulated gamma spectra were used to develop and test three fuel characterization algorithms. The classification and estimation models employed are based on the partial least squares regression (PLS) algorithm. A PLS discriminate analysis model was developed which perfectly classified reactor type. Locally weighted PLS models were fitted on-the-fly to estimate continuous fuel characteristics. Burn up was predicted within 0.1% root mean squared percent error (RMSPE) and both cooling time and initial enrichment within approximately 2% RMSPE. This automated fuel characterization can be used to independently verify operator declarations of used fuel characteristics and inform the MIP Monitor anomaly detection routines at later stages of the fuel reprocessing stream to improve sensitivity to changes in operational parameters and material diversions.

Multivariate Analysis for Characterization of Used↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparing Methods for Assessing Reliability Uncertainty Based on Pass/Fail Data Collected Over Time

In this paper, we compare statistical methods for analyzing pass/fail data collected over time; some methods are traditional and one (the RADAR or Rationale for Assessing Degradation Arriving at Random) was recently developed. These methods are used to provide uncertainty bounds on reliability. We make observations about the methods' assumptions and properties. Finally, we illustrate the differences between two traditional methods, logistic regression and Weibull failure time analysis, and the RADAR method using a numerical example.

97 MATHEMATICS AND COMPUTING↗

Primary Gleason Grade 4 Impact on Biochemical Recurrence After Permanent Interstitial Brachytherapy in Japanese Patients With Low- or Intermediate-Risk Prostate Cancer

Purpose: To reveal a predictive factor for biochemical recurrence (BCR) after permanent prostate brachytherapy (PPB) using iodine-125 seed implantation in patients with localized prostate cancer classified as low or intermediate risk based on National Comprehensive Cancer Network (NCCN) guidelines. Methods and Materials: From January 2004 to December 2009, 414 consecutive Japanese patients with clinically localized prostate cancer classified as low or intermediate risk based on the NCCN guidelines were treated with PPB. The clinical factors including pathological data reviewed by a central pathologist and follow-up data were prospectively collected. Kaplan-Meier and Cox regression analyses were used to assess the factors associated with BCR. Results: Median follow-up was 36.5 months. The 2-, 3-, 4-, and 5-year BCR-free rates using the Phoenix definition were 98.3%, 96.0%, 91.6%, and 87.0%, respectively. On univariate analysis, the Gleason score, especially primary Gleason grade 4 in biopsy specimens, was a strong predicting factor (p < 0.0001), while age, initial prostate-specific antigen (PSA) level, T stage, and minimal dose delivered to 90% of the prostate volume (D90) were insignificant. Multivariate analysis indicated that a primary Gleason grade 4 was the most powerful prognostic factor associated with BCR (hazard ratio = 6.576, 95% confidence interval, 2.597-16.468, p < 0.0001). Conclusions: A primary Gleason grade 4 carried a worse BCR prognosis than the primary grade 3 in patients treated with PPB. Therefore, the indication for PPB in patients with a Gleason sum of 4 + 3 deserves careful and thoughtful consideration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Marginal Recurrence Requiring Salvage Radiotherapy After Stereotactic Body Radiotherapy for Spinal Metastases

Introduction: We sought to quantify and identify risk factors associated with margin recurrence (MR) requiring salvage radiotherapy after stereotactic body radiation therapy (SBRT) for spinal metastases. Methods: We retrospectively reviewed patients with spinal metastases who were treated with single-fraction SBRT between 2006 and 2009. Gross tumor was contoured, along with either the entire associated vertebral body(ies) or the posterior elements, and included in the planning target volume. No additional margins were used. MR was defined as recurrent tumor within one vertebral level above or below the treated lesion that required salvage radiotherapy. Only patients who presented for 3-month post-SBRT follow-up were included in the analysis. Fine and Gray competing risk regression models were generated to identify variables associated with higher risks of MR. MR was plotted using cumulative incidence analysis. Results: SBRT was delivered to 208 lesions in 149 patients. Median follow-up was 8.6 months, and median survival was 12.8 months. The median prescribed dose was 14 Gy (10-16 Gy). MR occurred in 26 (12.5%) treated lesions, at a median time of 7.7 months after SBRT. Patients with paraspinal disease at the time of SBRT (20.8% vs. 7.6% of patients; p = 0.02), and those treated with <16 Gy (16.3% vs. 6.3% of patients, p = 0.14) had higher rates of MR. Both variables were associated with significantly higher risk of MR on multivariate analysis. Conclusion: SBRT for spinal metastases results in a low overall rate of MR. The presence of paraspinal disease at the time of SBRT and a dose of <16 Gy were associated with higher risks of MR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance evaluation of a hybrid-passive landfill leachate treatment system using multivariate statistical techniques

Highlights: • Performance of a hybrid passive landfill leachate treatment system was evaluated. • 33 Water chemistry parameters were sampled for 21 months and statistically analyzed. • Parameters were strongly linked and explained most (>40%) of the variation in data. • Alkalinity, ammonia, COD, heavy metals, and iron were criteria for performance. • Eight other parameters were key in modeling system dynamics and criteria. - Abstract: A pilot-scale hybrid-passive treatment system operated at the Merrick Landfill in North Bay, Ontario, Canada, treats municipal landfill leachate and provides for subsequent natural attenuation. Collected leachate is directed to a hybrid-passive treatment system, followed by controlled release to a natural attenuation zone before entering the nearby Little Sturgeon River. The study presents a comprehensive evaluation of the performance of the system using multivariate statistical techniques to determine the interactions between parameters, major pollutants in the leachate, and the biological and chemical processes occurring in the system. Five parameters (ammonia, alkalinity, chemical oxygen demand (COD), “heavy” metals of interest, with atomic weights above calcium, and iron) were set as criteria for the evaluation of system performance based on their toxicity to aquatic ecosystems and importance in treatment with respect to discharge regulations. System data for a full range of water quality parameters over a 21-month period were analyzed using principal components analysis (PCA), as well as principal components (PC) and partial least squares (PLS) regressions. PCA indicated a high degree of association for most parameters with the first PC, which explained a high percentage (>40%) of the variation in the data, suggesting strong statistical relationships among most of the parameters in the system. Regression analyses identified 8 parameters (set as independent variables) that were most frequently retained for modeling the five criteria parameters (set as dependent variables), on a statistically significant level: conductivity, dissolved oxygen (DO), nitrite (NO{sub 2}{sup −}), organic nitrogen (N), oxidation reduction potential (ORP), pH, sulfate and total volatile solids (TVS). The criteria parameters and the significant explanatory parameters were most important in modeling the dynamics of the passive treatment system during the study period. Such techniques and procedures were found to be highly valuable and could be applied to other sites to determine parameters of interest in similar naturalized engineered systems.

54 ENVIRONMENTAL SCIENCES↗

Robust Machine Learning Inference from X-ray Absorption Near Edge Spectra through Featurization

X-ray absorption spectroscopy (XAS) is a commonly employed technique for characterizing functional materials. In particular, X-ray absorption near edge spectra (XANES) encode local coordination and electronic information, and machine learning approaches to extract this information are of significant interest. To date, most ML approaches for XANES have primarily focused on using the raw spectral intensities as input, overlooking the potential benefits of incorporating spectral transformations and dimensionality reduction techniques into ML predictions. Here, in this work, we focused on systematically comparing the impact of different featurization methods on the performance of ML models for XAS analysis. We evaluated the classification and regression capabilities of these models on computed data sets and validated their performance on previously unseen experimental data sets. Our analysis revealed an intriguing discovery: the cumulative distribution function feature achieves both high prediction accuracy and exceptional transferability. This remarkably robust performance can be attributed to its tolerance to horizontal shifts in the spectra, which is crucial when validating models using experimental data. While this work exclusively focuses on XANES analysis, we anticipate that the methodology presented here will hold promise as a versatile asset to the broader spectroscopy community.

36 MATERIALS SCIENCE↗

Sparse multitask regression for identifying common mechanism of response to therapeutic targets

Motivation: Molecular association of phenotypic responses is an important step in hypothesis generation and for initiating design of new experiments. Current practices for associating gene expression data with multidimensional phenotypic data are typically (i) performed one-to-one, i.e. each gene is examined independently with a phenotypic index and (ii) tested with one stress condition at a time, i.e. different perturbations are analyzed separately. As a result, the complex coordination among the genes responsible for a phenotypic profile is potentially lost. More importantly, univariate analysis can potentially hide new insights into common mechanism of response. Results: In this article, we propose a sparse, multitask regression model together with co-clustering analysis to explore the intrinsic grouping in associating the gene expression with phenotypic signatures. The global structure of association is captured by learning an intrinsic template that is shared among experimental conditions, with local perturbations introduced to integrate effects of therapeutic agents. We demonstrate the performance of our approach on both synthetic and experimental data. Synthetic data reveal that the multitask regression has a superior reduction in the regression error when compared with traditional L1-and L2-regularized regression. On the other hand, experiments with cell cycle inhibitors over a panel of 14 breast cancer cell lines demonstrate the relevance of the computed molecular predictors with the cell cycle machinery, as well as the identification of hidden variables that are not captured by the baseline regression analysis. Accordingly, the system has identified CLCA2 as a hidden transcript and as a common mechanism of response for two therapeutic agents of CI-1040 and Iressa, which are currently in clinical use.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗