Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Self-consistent drift-diffusion-reaction model for the electron beam interaction with dielectric samples

The charging of insulating samples degrades the quality and complicates the interpretation of images in scanning electron microscopy and is important in other applications, such as particle detectors. In this paper, we analyze this nontrivial phenomenon on different time scales employing the drift-diffusion-reaction approach augmented with the trapping rate equations and a realistic semi-empirical source function describing the pulsed nature of the electron beam. We consider both the fast processes following the impact of a single primary electron, the slower dynamics resulting from the continuous bombardment of a sample, and the eventual approach to the steady-state regime.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reduced Energetic Disorders in Dion–Jacobson Perovskites for Efficient and Spectral Stable Blue LEDs

Metal halide perovskites have witnessed great success in green, red, and near-infrared light-emitting diodes (LEDs), yet blue LEDs still lag behind. Reducing undesired energetic disorders – broad n -phases and halide segregation – is considered as the most critical strategy to further improve the performances. Here, the study reports a newly designed and synthesized di-ammonium ligand with rigid π -conjugated rings and additional methyl groups to construct Dion–Jacobson (DJ) structure. Augmented coordination from the extra ammonium site and increased effective bulkiness from methyl groups lead to better distribution control over conventional mono-ammonium ligands. This enhances the radiative recombination of blue emissions in the film with homogeneous energy landscape and improved surface morphology, as evidenced by a series of imaging and mapping techniques. As a result, it demonstrates DJ perovskite LEDs (PeLEDs) with peak external quantum efficiencies of ≈4% at 484 nm and ≈11% at 494 nm, which are among the top reported for pure DJ phase-based PeLEDs in the corresponding wavelength regions. The results deepen the understanding of regulating energetic disorders in perovskite materials via molecular engineering.

36 MATERIALS SCIENCE↗

Enhanced detection of volatile organic compounds (VOCs) by caffeine modified carbon nanotube junctions

Detection of vapor phase analytes and gas molecules is primarily essential for numerous applications including medical diagnostic, environmental monitoring, chemical threat detection, food quality control, and chemical warfare agents. Here, we developed Caffeine functionalized carbon nanotubes (CNTs) random network based vapor quantum resistive sensors (vQRSs) for volatile organic compounds (VOCs) detection. The localized transmission electron microscopy (TEM) image and energy dispersive X-ray spectroscopy (EDS) confirm migration of caffeine to CNT–CNT junction (CNTj). We have recorded more than one order of magnitude higher sensitivity and unique selectivity towards selective VOCs (e.g., acetone, toluene, ethanol, methanol, etc.) with short response time (few seconds) for caffeine modified CNT junction (Caf-CNTj) vQRSs. Molecular dynamics (MD) calculations suggest that the sensitivity of the sensor is diffusion limited, with an advective contribution for ethanol. Furthermore, the designed Caf-CNTj sensors can potentially be important candidate to be a part of electronic nose used for various application such as breath analysis and food quality monitoring.

36 MATERIALS SCIENCE↗

NWChem: Recent and Ongoing Developments

In this paper we summarize developments in the NWChem computational chemistry suite since the last major release (NWChem 7.0). Specifically, we focus on functionalities, along with input blocks, that are currently accessible in the current stable release (NWChem 7.2) and master branches, interfaces to quantum computing simulators, interfaces to external libraries, the NWChem GitHub repository, and containerization of NWChem executable images. In conclusion, some of the ongoing developments that will be available in the near future are also discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A glimpse of gluons through deeply virtual compton scattering on the proton

The proton is composed of quarks and gluons, bound by the most elusive mechanism of strong interaction called confinement. In this work, the dynamics of quarks and gluons are investigated using deeply virtual Compton scattering (DVCS): produced by a multi-GeV electron, a highly virtual photon scatters off the proton which subsequently radiates a high energy photon. Similarly to holography, measuring not only the magnitude but also the phase of the DVCS amplitude allows to perform 3D images of the internal structure of the proton. The phase is made accessible through the quantum-mechanical interference of DVCS with the Bethe-Heitler (BH) process, in which the final photon is emitted by the electron rather than the proton. Here, we report herein the first full determination of the BH-DVCS interference by exploiting the distinct energy dependences of the DVCS and BH amplitudes. In the high energy regime where the scattering process is expected to occur off a single quark in the proton, these accurate measurements show an intriguing sensitivity to gluons, the carriers of the strong interaction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optical tomographic reconstruction of ion beam induced refractive index changes in silica

Refractive index changes induced by ion beam implantation can be used to produce photonic devices such as waveguides. Here, we relate the measured three-dimensional changes in refractive index produced by ion beam implantation to modeling of the implantation process. We use a quantitative phase microscopic method in conjunction with a tomographic reconstruction process to determine the change in the refractive index distribution within a silica optical fiber that has been selectively implanted with 2.4 MeV H{sup +} ions. The index profile is compared with numerical simulations of the ion vacancy and ionization using the stopping range of ions in matter program.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spatial emission tomography reconstruction using Pitman-Yor process

In this paper, we address the problem of emission tomography spatial reconstruction in three dimensions following a Bayesian nonparametric approach. Our model makes use of a generalization of the Dirichlet process called Pitman-Yor process. The problem in this approach is to deal with the infinite representation of the distribution in the inference. So we propose an efficient Markov Chain Monte-Carlo sampling scheme which is able to generate samples from the posterior distribution of the activity distribution. An application to 3D-PET reconstruction is presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detection of a 2.8 THz quantum cascade laser with a semiconductor nanowire field-effect transistor coupled to a bow-tie antenna

The use of a high-electron mobility semiconductor nanowire as transistor channel has recently allowed the extension of the spectral coverage of THz field-effect transistor detectors up to 1.5 THz. In this report, we demonstrate efficient operation of a field-effect transistor detector based on a semiconductor nanowire at a much higher frequency, 2.8 THz, with a responsivity ≈5 V/W in a bandwidth ≈100 kHz, thus proving the full potential of such approach for the detection of THz quantum cascade lasers. Finally, such a THz sensing system is exploited to perform raster scan transmission imaging, with high spatial resolution, signal-to-noise ratio, and acquisition rate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Synthesis of nano-sized ZnO particles by co-precipitation method with variation of heating time

Zinc oxide powders have been synthesized by a co-precipitation method at low temperature (85 °C), using zinc acetate dihydrate, ammonia, hydrochloric acid solutions as the reactants. A number of process parameters such as reaction temperature, solution basicity or pH and heating time are the main factors affecting the morphology and physical properties of the ZnO nanostructures. In this work the effect of heating time on the morphology and particles size were studied. The as-synthesized ZnO powders were characterized using transmission electron microscopy (TEM) and X-ray diffraction (XRD) techniques. The samples were also analyzed using Fourier transform infrared (FTIR). Rietveld refinement of XRD data confirms that ZnO crystallizes in the hexagonal wurtzite structure with high degree of purity and the (101) plane predominant. The XRD results show that the average crystallite sizes were about 66, 27 and 12 nm for 3, 4 and 5 h of heating times, respectively. The XRD analysis indicated that a fraction of nano-sized ZnO powders were in the form of aggregates, which was also verified by TEM image. The TEM photograph demonstrated that the nano-sized ZnO particles were a pseudo-spherical shape.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uncovering surface plasmon optical resonances in nanohole arrays through interferometric photoemission electron microscopy

In this work, the role of surface plasmon polaritons (SPPs) in nanohole array optical extinction spectra is explored using a time-resolved technique capable of isolating the air/metal interfacial SPP contribution to the typical Fano profile in optical transmission curves. A pair of interferometrically locked broad-band femtosecond pulses is used to launch SPPs from lithographically patterned plasmonic nanohole arrays. SPPs launched in the co- and counter-propagating directions are probed using a third probe pulse in a photoemission electron microscope. Using this approach, we record interferometric SPP–SPP linear autocorrelations that selectively report on the resonances of SPPs launched from arrays of varying pitches and hole diameters. Aside from advancing an approach to selective SPP spectroscopy, we illustrate that resonant coupling in the counter-propagating direction may be exploited to control the spatial, temporal, and spectral characteristics of SPPs. For the counter-propagating direction, we show that tuning the array pitch near the fundamental plasmon resonance generates color-tuned (~770–820 nm), narrow bandwidth SPPs, and the bandwidth may be controlled by changing the ratio of pitch to hole diameter. The SPP resonances we recover through Fourier transforms of the interferometric autocorrelations shed light on the classical problem of Fano interference in nanohole array extinction spectra.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Information coding of exciting laser pulses in an optical echo-processor

We report the possibility of controlling the distribution of quantum bits within an inhomogeneously broadened line of a resonant transition in recording and transforming information in optical echo-processors. We consider the efficiency of realisation of the elementary logic XOR gate based on a two-pulse excitation of a resonant medium with phase memory. The encoded information is incorporated into the temporal shape of laser pulses in the form of amplitude modulation of an 'echelon' of present ('1') and absent ('0') pulse-codes for obtaining more efficient logic elements that reduce the noise in a quantum communication channel. (optical information processing)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Imaging coherent phonons and precursor dynamics in LaFeAsO with 4D ultrafast electron microscopy

In this work, we used 4D ultrafast electron microscopy (UEM) to directly image femtosecond photoinduced structural dynamics in single-crystal LaFeAsO at initial temperatures of 300 and 100 K, above and below the known structural and magnetic phase-transition temperatures, respectively. With nanometer-picosecond resolution, we resolved an initial (precursor) sigmoidlike response arising from photothermal expansion and lattice reorientation that precedes the onset of propagating coherent acoustic phonons (CAPs). In the specific regions probed, the precursor response at 100 K is shorter than at 300 K ($t$ 0.5;100 K = 11.3ps vs $t$ 0.5;300 K = 17.8ps), and the CAP oscillation frequency is lowered with cooling (ƒ CAP;100 K = 12 GHz vs ƒ CAP;300 K = 21 GHz), correlated to known lattice softening due to the structural phase change. The transient CAP behaviors at 300 K are dispersive, displaying an exponentially decaying phase velocity over the first nanosecond. Further, the CAP symmetry at 300 K matches a first-order antisymmetric shear mode (A 1 ), while at 100 K it is best matched by a mostly nondispersive zero-order symmetric mode (S 0 ). These findings illustrate the sensitivity of UEM imaging to spatially heterogeneous dynamics in the Fe-pnictide materials and more broadly in other quantum materials.

36 MATERIALS SCIENCE↗

Noise variance analysis using a flat panel x-ray detector: A method for additive noise assessment with application to breast CT applications

Purpose: A simplified linear model approach was proposed to accurately model the response of a flat panel detector used for breast CT (bCT). Methods: Individual detector pixel mean and variance were measured from bCT projection images acquired both in air and with a polyethylene cylinder, with the detector operating in both fixed low gain and dynamic gain mode. Once the coefficients of the linear model are determined, the fractional additive noise can be used as a quantitative metric to evaluate the system's efficiency in utilizing x-ray photons, including the performance of different gain modes of the detector. Results: Fractional additive noise increases as the object thickness increases or as the radiation dose to the detector decreases. For bCT scan techniques on the UC Davis prototype scanner (80 kVp, 500 views total, 30 frames/s), in the low gain mode, additive noise contributes 21% of the total pixel noise variance for a 10 cm object and 44% for a 17 cm object. With the dynamic gain mode, additive noise only represents approximately 2.6% of the total pixel noise variance for a 10 cm object and 7.3% for a 17 cm object. Conclusions: The existence of the signal-independent additive noise is the primary cause for a quadratic relationship between bCT noise variance and the inverse of radiation dose at the detector. With the knowledge of the additive noise contribution to experimentally acquired images, system modifications can be made to reduce the impact of additive noise and improve the quantum noise efficiency of the bCT system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multilevel learning-based segmentation of ill-defined and spiculated masses in mammograms

Purpose: A learning-based approach integrating the use of pixel-level statistical modeling and spiculation detection is presented for the segmentation of mammographic masses with ill-defined margins and spiculations. Methods: The algorithm involves a multiphase pixel-level classification, using a comprehensive group of features computed from regional intensity, shape, and textures, to generate a mass-conditional probability map (PM). Then, the mass candidate, along with the background clutters consisting of breast fibroglandular and other nonmass tissues, is extracted from the PM by integrating the prior knowledge of shape and location of masses. A multiscale steerable ridge detection algorithm is employed to detect spiculations. Finally, all the object-level findings, including mass candidate, detected spiculations, and clutters, along with the PM, are integrated by graph cuts to generate the final segmentation mask. Results: The method was tested on 54 masses (51 malignant and 3 benign), all with ill-defined margins and irregular shape or spiculations. The ground truth delineations were provided by five experienced radiologists. Area overlapping ratio of 0.689 ({+-}0.160) and 0.540 ({+-}0.164) were obtained for segmenting entire mass and margin portion only, respectively. Williams index of area and contour based measurements indicated that the segmentation results of the algorithm agreed well with the radiologists' delineation. Conclusions: The proposed approach could closely delineate the mass body. Most importantly, it is capable of including mass margin and its spicule extensions which are considered as key features for breast lesion analyses.

60 APPLIED LIFE SCIENCES↗

A digitally reconstructed radiograph algorithm calculated from first principles

Purpose: To develop an algorithm for computing realistic digitally reconstructed radiographs (DRRs) that match real cone-beam CT (CBCT) projections with no artificial adjustments. Methods: The authors used measured attenuation data from cone-beam CT projection radiographs of different materials to obtain a function to convert CT number to linear attenuation coefficient (LAC). The effects of scatter, beam hardening, and veiling glare were first removed from the attenuation data. Using this conversion function the authors calculated the line integral of LAC through a CT along rays connecting the radiation source and detector pixels with a ray-tracing algorithm, producing raw DRRs. The effects of scatter, beam hardening, and veiling glare were then included in the DRRs through postprocessing. Results: The authors compared actual CBCT projections to DRRs produced with all corrections (scatter, beam hardening, and veiling glare) and to uncorrected DRRs. Algorithm accuracy was assessed through visual comparison of projections and DRRs, pixel intensity comparisons, intensity histogram comparisons, and correlation plots of DRR-to-projection pixel intensities. In general, the fully corrected algorithm provided a small but nontrivial improvement in accuracy over the uncorrected algorithm. The authors also investigated both measurement- and computation-based methods for determining the beam hardening correction, and found the computation-based method to be superior, as it accounted for nonuniform bowtie filter thickness. The authors benchmarked the algorithm for speed and found that it produced DRRs in about 0.35 s for full detector and CT resolution at a ray step-size of 0.5 mm. Conclusions: The authors have demonstrated a DRR algorithm calculated from first principles that accounts for scatter, beam hardening, and veiling glare in order to produce accurate DRRs. The algorithm is computationally efficient, making it a good candidate for iterative CT reconstruction techniques that require a data fidelity term based on the matching of DRRs and projections.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

IRMMW-THz 2011 - The 36 th International Conference on Infrared, Millimeter, and Terahertz Waves

The Major Topic List of the 2011 conference featured a category entitled “IR, millimeter-wave, and THz spectroscopy,” another entitled “Gyro-Oscillators and Amplifiers, Plasma Diagnostics,” and a third called “Free Electron Lasers and Synchrotron Radiation.” Topical areas of interest to meeting participants include millimeter-wave electronics, high-power sources, high-frequency communications systems, and terahertz sensing and imaging, all of which are prominent in the research portfolios of the DOE. The development and study of new materials, components, and systems for use in the IR, THz, and MMW regions of the spectrum are of significant interest as well. a series of technical sessions were organized on the following topics: terahertz metamaterials and plasmonics; imaging techniques and applications; graphene spectroscopy; waveguide concepts; gyrotron science and technology; ultrafast terahertz measurements; and quantum cascade lasers.

42 ENGINEERING↗

State-of-the-art Space Telescope Digicon performance data

The Digicon has been chosen as the detector for the High Resolution Spectrograph and the Faint Object Spectrograph of the Space Telescope. Both tubes are 512 channel, parallel-output devices and feature CsTe photocathodes on MgF2 faceplates. Using a computer-assisted test facility, the tubes have been characterized with respect to diode array performance, photocathode response (1100-9000 A), and imaging capability. Data are presented on diode dark current and capacitance distributions, pulse height resolution, photocathode quantum efficiency, uniformity and blemishes, dark count rate, distortion, resolution, and crosstalk.

Ginaven, R. O.↗