Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microorganisms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Mathematical estimation of the level of microbial contamination on spacecraft surfaces by volumetric air sampling

Microbiological sampling methods presently used for enumeration of microorganisms on spacecraft surfaces require contact with easily damaged components. Estimation of viable particles on surfaces using air sampling methods in conjunction with a mathematical model would be desirable. Parameters necessary for the mathematical model are the effect of angled surfaces on viable particle collection and the number of viable cells per viable particle. Deposition of viable particles on angled surfaces closely followed a cosine function, and the number of viable cells per viable particle was consistent with a Poisson distribution. Other parameters considered by the mathematical model included deposition rate and fractional removal per unit time. A close nonlinear correlation between volumetric air sampling and airborne fallout on surfaces was established with all fallout data points falling within the 95% confidence limits as determined by the mathematical model.

Oxborrow, G. S.↗

Microbial load monitor

Device can detect and identify a number of medically important microorganisms in an average of approximately 8 hours. Monitor consists of cartridges containing special selective media and solid state electro-optical detectors.

Jones, P. W.↗

New methodology for assessing the probability of contaminating Mars

Methodology is proposed to assess the probability that the planet Mars will be contaminated by terrestrial microorganisms aboard a spacecraft. The present NASA methods are extended to permit utilization of detailed information on microbial characteristics, the lethality of release and transport mechanisms, and of other information about the Martian environment. Different types of microbial release are distinguished, and for each release mechanism a probability of growth is computed. Using this new methodology, an assessment was carried out for the 1975 Viking landings on Mars. The resulting probability of contamination for each Viking lander is 6 x 10 to the -6 power, and is amenable to revision as additional information becomes available.

North, D. W.↗

Ecology and thermal inactivation of microbes in and on interplanetary space vehicle components

A series of experiments was conducted to determine the dry heat resistance of microorganisms in soil obtained from Denver Colorado, Pasadena California, Kennedy Space Center Florida, and Cincinnati Ohio. The results of the KSC terminal sterilization cycle experiment are given in graphs. The average number of viable organisms per m1 was calculated for 18 replicate soil samples for each sample area and points plotted equivalent to 30 hr exposure at 112 C. The result showed a reduction of 3 logs from the initial population for both KSC and Cincinnati soil samples. Results from other areas are given in graphs.

Reyes, A. L.↗

Environmental microbiology as related to planetary quarantine

Continued experimental work related to dry heat resistance of microorganisms. One phase of this research has been concerned with the viability and dry heat resistance of indigenous microflora associated with small soil particles. The second part of this report is an analysis of the present status of dry heat sterilization. An attempt is made to integrate results for both laboratory grown spores and spores in soil.

Pflug, I. J.↗

Microbial detection method based on sensing molecular hydrogen

A simple method for detecting bacteria, based on the time of hydrogen evolution, was developed and tested against various members of the Enterobacteriaceae group. The test system consisted of (1) two electrodes, platinum and a reference electrode, (2) a buffer amplifier, and (3) a strip-chart recorder. Hydrogen evolution was measured by an increase in voltage in the negative (cathodic) direction. A linear relationship was established between inoculum size and the time hydrogen was detected (lag period). Lag times ranged from 1 h for 1 million cells/ml to 7 h for 1 cell/ml. For each 10-fold decrease in inoculum, length of the lag period increased 60 to 70 min. Based on the linear relationship between inoculum and lag period, these results indicate the potential application of the hydrogen-sensing method for rapidly detecting coliforms and other gas-producing microorganisms in a variety of clinical, food, and other samples.

Wilkins, J. R.↗

Viking to Mars - The mission strategy

The Viking mission is discussed which will search for evidence of life on Mars by performing extended and closeup reconnaissance of the planet's surface. Previous unsuccessful Soviet attempts to land scientific payloads on Mars are summarized, and choices of landing sites for the two Viking landers are discussed. The onboard computers in both the orbiter and the two landers are described with emphasis on their 18,000-word memories and reprograming capabilities. The mission profiles and lander programs are outlined in detail, and lander experiments are discussed which will involve surface imaging, meteorological and seismometric measurements, soil sampling, lower atmosphere analysis, and searches for possible Martian microorganisms.

Sagan, C.↗

Geochemistry and the origin of life

The origin of life on earth is examined from a viewpoint stressing the validity of the concept of chemical evolution. The different geological formations supporting the mechanisms of the theory are described; the stage of chemical evolution (preceding that of biological evolution) would have taken place from the time of the origin of the earth and meteorites, 4.6 billion years ago, to the early Precambrian period, about 3.2 billion years ago. Specific aspects of the problem discussed include amino acids from spark discharges and their comparison with the Murchison meteorite amino acids, the properties and theory of genesis of the carbonaceous complex within the cold Bokevelt meteorite, ammonion ion concentration in the primitive ocean, the oxygen isotope chemistry of ancient charts, the origin and rise of oxygen concentration in the earth's atmosphere, Precambrian microorganisms and evolutionary events prior to the origin of vascular plants, and biogenicity and significance of the oldest known stromatolites.

Kvenvolden, K. A.↗

Fraction collector for electrophoresis

Rotating-tube electrophoresis apparatus employs rotating jet of eluting buffer to reduce effects of convection during separation. Designed for separation of microorganisms and biological species, system combines gravity/gradient compensating of lumen with buffer flush at fraction outlet to increase separation efficiency.

Bier, M.↗

Remote water-monitoring system

General-purpose, water-quality sampling process detects microorganisms and integrates sampling, sample preservation, and sample analysis. System overcomes difficulties in correlation of surface measurements with remote measurements and minimizes human error in handling of samples and instrumentation.

Grana, D. C.↗

Application and utilization of a space chamber for the drying and decontamination of books, documents and other materials

Truckloads of materials such as rare books, papers, engineering drawings, blue prints, art work, leather objects such as shoes, and clothing were successfully dried, decontaminated and impregnated against future infestation by microorganisms in a large 12 x 24 foot vacuum chamber designed originally for testing unmanned spacecraft. The process is unique in that it allows either frozen or wet material, soaked by some castastrophic event to be dried and sterilized in the same chamber with a minimum of handling and transportation.

Koesterer, M. G.↗

A thermal vacuum-UV solar simulator test system for assessing microbiological viability

Microorganisms were exposed to a simulated space environment in order to assess the photobiological effect of broad spectrum, nonionizing solar electromagnetic radiation in terms of viability. A thermal vacuum chamber capable of maintaining a vacuum of 0.000133n/sq m and an ultraviolet rich solar simulator were the main ingredients of the test system. Results to date indicate the system to be capable of providing reliable microbiological data.

Ross, D. S.↗

Microbiological investigations

The crew microbiology program was conducted to evaluate lunar contamination, to detect potentially pathogenic microoganisms, to identify medically important microorganisms recovered from ill crewmen, to aid in diagnosis and treatment, and to collect microbiological data that would aid in elucidating the response of the crew microbial autoflora to the space flight environment and in evaluating the resultant effect on the crewmember. Microbiological sampling of selected sites in the command module was initiated in support of the quarantine program. During lunar quarantine missions, microbial screening was accomplished for all support personnel to be isolated with the returning crewman. Virology support for the Apollo project consisted of characterization of the viral and mycoplasma flora of the crewmembers and performance of viral serology for crewmembers, crew contacts, and key mission personnel. Procedures and results are discussed in detail.

James K. Ferguson↗

A rapid method for the determination of microbial susceptibility using the firefly luciferase assay for adenosine triphosphate (ATP)

Luciferase assay for adenosine triphosphate (ATP) was optimized for pure bacteria in broth in order to evaluate if changes in bacterial ATP content could be used as a rapid measure of antibiotic effect on microorganisms. Broth cultures of log phase bacteria were incubated at 310 K (37 C) for 2.5 hours at antimicrobial concentrations which resulted in the best discrimination between sensitive and resistant strains. Eighty-seven strains of 11 bacterial species were studied for their susceptibility to 12 commonly used antimicrobial agents: ampicillin, Penicillin G, nafcillin, carbenicillin, cephalothin, tetracycline, erythromycin, clindamycin, gentamicin, nitrofurantoin, colistin, and chloramplenicol. The major advantage of the ATP system over existing methods of rapid microbial susceptibility testing is that the assay can be made specific for bacterial ATP.

Vellend, H.↗

Applications of adenine nucleotide measurements in oceanography

The methodology involved in nucleotide measurements is outlined, along with data to support the premise that ATP concentrations in microbial cells can be extrapolated to biomass parameters. ATP concentrations in microorganisms and nucleotide analyses are studied.

Holm-Hansen, O.↗

Plasma Sterilization Technology for Spacecraft Applications

The application of plasma gas technology to sterilization and decontamination of spacecraft components is considered. Areas investigated include: effective sterilizing ranges of four separate gases; lethal constituents of a plasma environment; effectiveness of plasma against a diverse group of microorganisms; penetrating efficiency of plasmas for sterilization; and compatibility of spacecraft materials with plasma environments. Results demonstrated that plasma gas, specifically helium plasma, is a highly effective sterilant and is compatible with spacecraft materials.

Fraser, S. J.↗

Studies related to the development of the Viking 1975 labeled release experiment

The labeled release life detection experiment on the Viking 1975 Mars mission is based on the concept that microorganisms will metabolize radioactive organic substrates in a nutrient medium and release radioactive carbon dioxide. Several experiments, using laboratory equipment, were carried out to evaluate various aspects of the concept. Results indicate: (1) label is released by sterilization-treated soil, (2) substantial quantities of label are retained in solution under basic conditions, (3) the substrate used, as well as position of label in the molecule, affect release of label, (4) label release is depressed by radiolytic decomposition of substrates, and (5) About 100,000 organisms are required to produce a detectable response. These results, suggest additional areas for testing, add to the data base for interpretation of flight results, and have significance for broader application of this technique for assessing microbial activity.

Devincenzi, D. L.↗