Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “method development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Investigation on lateral resolution of surface slope profilers

Here, we investigate and compare the spatial (lateral) resolution, or more generally, the optical/instrumental transfer function (OTF/ITF) of surface slope measuring profilometers of two different types that are commonly used for high accuracy characterization of x-ray optics at the long-spatial-wavelength range. These are an autocollimator based profiler, Optical Surface Measuring System (OSMS), and a long trace profiler, LTP-II, both available at the Advanced Light Source (ALS) X-Ray Optics Lab (XROL). In the OSMS, an ELCOMAT-3000 electronic auto-collimator, vertically mounted to the translation carriage and equipped with an aperture of 2.5 mm diameter, is scanned along the surface under test. The LTP-II OTF has been measured for two different configurations, a classical two-beam pencil-beam-interferometry and a single-Gaussian-beam deflectometry. For the ITF calibration, we apply a recently developed method based on test surfaces with one-dimensional (1D) linear chirped height profiles of constant slope amplitude. Analytical expressions for the OTFs, empirically deduced based on the experimental results, are presented. We also discuss the application of the results of the ITF measurements and modeling to improve the surface slope metrology with state-of-the-art x-ray mirrors.

42 ENGINEERING↗

Second-surface silvered glass solar mirrors of very high reflectance

This paper reports methods developed to maximize the overall reflectance second-surface silvered glass. The reflectance at shorter wavelengths is increased with the aid of a dielectric enhancing layer between the silver and the glass, while at longer wavelengths it is enhanced by use of glass with negligible iron content. The calculated enhancement of reflectance, compared to unenhanced silver on standard low-iron float glass, corresponds to a 4.4% increase in reflectance averaged across the full solar spectrum, appropriate for CSP, and 2.7% for CPV systems using triple junction cells. An experimental reflector incorporating these improvements, of drawn crown glass and a silvered second-surface with dielectric boost, was measured at NREL to have 95.4% solar weighted reflectance. For comparison, non-enhanced, wetsilvered reflectors of the same 4 mm thickness show reflectance ranging from 91.6 - 94.6%, depending on iron content. A potential drawback of using iron-free drawn glass is reduced concentration in high concentration systems because of the inherent surface errors. This effect is largely mitigated for glass shaped by slumping into a concave mold, rather than by bending.

14 SOLAR ENERGY↗

Accuracy of Acuros XB and AAA dose calculation for small fields with reference to RapidArc stereotactic treatments

Purpose: To assess the accuracy against measurements of two photon dose calculation algorithms (Acuros XB and the Anisotropic Analytical algorithm AAA) for small fields usable in stereotactic treatments with particular focus on RapidArc. Methods: Acuros XB and AAA were configured for stereotactic use. Baseline accuracy was assessed on small jaw-collimated open fields for different values for the spot sizes parameter in the beam data: 0.0, 0.5, 1, and 2 mm. Data were calculated with a grid of 1 x 1 mm{sup 2}. Investigated fields were: 3 x 3, 2 x 2, 1 x 1, and 0.8 x 0.8 cm{sup 2} with a 6 MV photon beam generated from a Clinac2100iX (Varian, Palo Alto, CA). Profiles, PDD, and output factors were measured in water with a PTW diamond detector (detector size: 4 mm{sup 2}, thickness 0.4 mm) and compared to calculations. Four RapidArc test plans were optimized, calculated and delivered with jaw settings J3 x 3, J2 x 2, and J1 x 1 cm{sup 2}, the last was optimized twice to generate high (H) and low (L) modulation patterns. Each plan consisted of one partial arc (gantry 110 deg. to 250 deg.), and collimator 45 deg. Dose to isocenter was measured in a PTW Octavius phantom and compared to calculations. 2D measurements were performed by means of portal dosimetry with the GLAaS method developed at authors' institute. Analysis was performed with gamma pass-fail test with 3% dose difference and 2 mm distance to agreement thresholds. Results: Open square fields: penumbrae from open field profiles were in good agreement with diamond measurements for 1 mm spot size setting for Acuros XB, and between 0.5 and 1 mm for AAA. Maximum MU difference between calculations and measurements was 1.7% for Acuros XB (0.2% for fields greater than 1 x 1 cm{sup 2}) with 0.5 or 1 mm spot size. Agreement for AAA was within 0.7% (2.8%) for 0.5 (1 mm) spot size. RapidArc plans: doses were evaluated in a 4 mm diameter structure at isocenter and computed values differed from measurements by 0.0, -0.2, 5.5, and -3.4% for Acuros XB calculations (1 mm spot size), and of -0.1, 0.3, 6.7, and -1.2% for AAA, respectively for J3 x 3, J2 x 2, J1 x 1H, J1 x 1L RapidArc plans. Gamma Agreement Index from 2D dose analysis was higher than 95% for J3 x 3 and J2 x 2 plans, being around 80% for J1 x 1 maps. Sensitivity with respect to the dosimetric leaf gap and transmission factor MLC parameters was evaluated in the four RapidArc plans, showing the need to properly set the dosimetric leaf gap for accurate calculations. Conclusions: Acuros XB and AAA showed acceptable characteristics for stereotactic small fields if adequate tuning of configuration parameters is performed. Dose calculated for RapidArc stereotactic plans showed an acceptable agreement against point and 2D measurements. Both algorithms can therefore be considered safely applicable to stereotactic treatments.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-233: A Facility for Radiobiological Experiments in a Large Magnetic Field

Purpose: There is considerable interest in developing medical linear accelerators with integrated image guidance by MRI. Less work has been done on the fundamental biology of cell survival in the presence of a strong magnetic field. The purpose of this work is to describe an experimental system capable of measuring cell survival response in the types of MRI-linac systems currently under development. Methods: We have integrated a cobalt irradiator with a solenoid magnet. The solenoid magnet has inner diameter of 10 cm. To enable measurement of the biological effects as a function of depth, we are utilizing the sliced gel technique, in which cells are embedded and fixed within a gelatin matrix. Irradiated cells at defined positions (sub mm resolution) can subsequently be recovered and assessed for cell survival or other biological effects. Results: The magnetic field profile in the solenoid has a peak magnetic field 36 cm below the top edge of the magnet bore and can be placed at and SAD of 100 cm. At a solenoid current of 35 A, the peak magnetic field is 0.25 T. The dose rate of the cobalt irradiator is 16 cGy/min at 100 cm SAD. EBT3 film was used to demonstrate the system functionality. It was irradiated at 1 cm depth at 100 cm SSD with a 4×4 field to 1.5 Gy in a 0.25 T magnetic field. The dose profile was similar between this film and the control exposure without magnetic field. Conclusion: Integrating a cobalt irradiator with a high field magnet is demonstrated. The magnetic field at the cobalt defining head was minimal and did not interfere with the functioning of this unit. Cell survival experiments can be reproduced exactly in the presence or absence of a magnetic field since a resistive magnet is used.

60 APPLIED LIFE SCIENCES↗

SU-E-T-154: Establishment and Implement of 3D Image Guided Brachytherapy Planning System

Purpose: Cannot observe the dose intuitionally is a limitation of the existing 2D pre-implantation dose planning. Meanwhile, a navigation module is essential to improve the accuracy and efficiency of the implantation. Hence a 3D Image Guided Brachytherapy Planning System conducting dose planning and intra-operative navigation based on 3D multi-organs reconstruction is developed. Methods: Multi-organs including the tumor are reconstructed in one sweep of all the segmented images using the multiorgans reconstruction method. The reconstructed organs group establishs a three-dimensional visualized operative environment. The 3D dose maps of the three-dimentional conformal localized dose planning are calculated with Monte Carlo method while the corresponding isodose lines and isodose surfaces are displayed in a stereo view. The real-time intra-operative navigation is based on an electromagnetic tracking system (ETS) and the fusion between MRI and ultrasound images. Applying Least Square Method, the coordinate registration between 3D models and patient is realized by the ETS which is calibrated by a laser tracker. The system is validated by working on eight patients with prostate cancer. The navigation has passed the precision measurement in the laboratory. Results: The traditional marching cubes (MC) method reconstructs one organ at one time and assembles them together. Compared to MC, presented multi-organs reconstruction method has superiorities in reserving the integrality and connectivity of reconstructed organs. The 3D conformal localized dose planning, realizing the 'exfoliation display' of different isodose surfaces, helps make sure the dose distribution has encompassed the nidus and avoid the injury of healthy tissues. During the navigation, surgeons could observe the coordinate of instruments real-timely employing the ETS. After the calibration, accuracy error of the needle position is less than 2.5mm according to the experiments. Conclusion: The speed and quality of 3D reconstruction, the efficiency in dose planning and accuracy in navigation all can be improved simultaneously.

60 APPLIED LIFE SCIENCES↗

SU-E-QI-16: Reproducibility of Computed Tomography Quantitative Structural Features Using the FDA Thoracic Phantom Image Database

Purpose: To assess the reproducibility of quantitative structural features using images from the computed tomography thoracic FDA phantom database under different scanning conditions. Methods: Development of quantitative image features to describe lesion shape and size, beyond conventional RECIST measures, is an evolving area of research in need of benchmarking standards. Gavrielides et al. (2010) scanned a FDA-developed thoracic phantom with nodules of various Hounsfield units (HU) values, shapes and sizes close to vascular structures using several scanners and varying scanning conditions/parameters; these images are in the public domain. We tested six structural features, namely, Convexity, Perimeter, Major Axis, Minor Axis, Extent Mean and Eccentricity, to characterize lung nodules. Convexity measures lesion irregularity referenced to a convex surface. Previously, we showed it to have prognostic value in lung adenocarcinoma. The above metrics and RECIST measures were evaluated on three spiculated (8mm/-300HU, 12mm/+30HU and 15mm/+30HU) and two non-spiculated (8mm/+100HU and 10mm/+100HU) nodules (from layout 2) imaged at three different mAs values: 25, 100 and 200 mAs; on a Phillips scanner (16-slice Mx8000-IDT; 3mm slice thickness). The nodules were segmented semi-automatically using a commercial software tool; the same HU range was used for all nodules. Results: Analysis showed convexity having the lowest maximum coefficient of variation (MCV): 1.1% and 0.6% for spiculated and non-spiculated nodules, respectively, much lower compared to RECIST Major and Minor axes whose MCV were 10.1% and 13.4% for spiculated, and 1.9% and 2.3% for non-spiculated nodules, respectively, across the various mAs. MCVs were consistently larger for speculated nodules. In general, the dependence of structural features on mAs (noise) was low. Conclusion: The FDA phantom CT database may be used for benchmarking of structural features for various scanners and scanning conditions; we used only a small fraction of available data. Our feature convexity outperformed other structural features including RECIST measures.

60 APPLIED LIFE SCIENCES↗

Sci—Thur AM: YIS - 11: Estimation of Bladder-Wall Cumulative Dose in Multi-Fraction Image-Based Gynaecological Brachytherapy Using Deformable Point Set Registration

Dosimetric parameters based on dose-volume histograms (DVH) of contoured structures are routinely used to evaluate dose delivered to target structures and organs at risk. However, the DVH provides no information on the spatial distribution of the dose in situations of repeated fractions with changes in organ shape or size. The aim of this research was to develop methods to more accurately determine geometrically localized, cumulative dose to the bladder wall in intracavitary brachytherapy for cervical cancer. The CT scans and treatment plans of 20 cervical cancer patients were used. Each patient was treated with five high-dose-rate (HDR) brachytherapy fractions of 600cGy prescribed dose. The bladder inner and outer surfaces were delineated using MIM Maestro software (MIM Software Inc.) and were imported into MATLAB (MathWorks) as 3-dimensional point clouds constituting the “bladder wall”. A point-set registration toolbox for MATLAB, Coherent Point Drift (CPD), was used to non-rigidly transform the bladder-wall points from four of the fractions to the coordinate system of the remaining (reference) fraction, which was chosen to be the emptiest bladder for each patient. The doses were accumulated on the reference fraction and new cumulative dosimetric parameters were calculated. The LENT-SOMA toxicity scores of these patients were studied against the cumulative dose parameters. Based on this study, there was no significant correlation between the toxicity scores and the determined cumulative dose parameters.

60 APPLIED LIFE SCIENCES↗

SU-E-T-111: An Iterative Approach to Modelling Dosimetric Properties of a Varian MLC

Purpose: In effort to efficiently and accurately model MLC parameters for use in Varian Eclipse treatment planning system (TPS), an iterative technique for characterizing the dosimetric properties of MLCs has been developed. Methods: The initial characterization of the dosimetric leaf gap (DLG) and MLC transmission was performed using varied sizes of moving gaps and transmission measurements through central axis of the radiation beam. These values were determined during the initial data collection. After the initial values were determined and entered into the TPS, two plans were calculated to test the veracity of DLG and transmission independently. The plan used to determine the DLG has openings of varied sizes which are affected differently by the DLG. A large field uniform fluence that required a MLC carriage shift was used to determine the transmission value independent of DLG. After characterizing the dosimetric properties of the MLC independently, clinical IMRT plans were tested and used to tweak the final values. Results: This approach to modelling MLC dosimetric properties was employed for: standard 120 leaf MLC (SDMLC) and 120 leaf high definition MLC (HDMLC). Both types were successfully commissioned, tested, and approved for clinical use on 4 SDMLC machines and 2 HDMLC machines. The pass rate of clinical IMRT plans was 96.9% for 6MV and 98.3% for 10MV for SDMLC and 96.3% for 6MV, 96.5% for 6FFF, and 97.5% for 10FFF for HDMLCs using MapCheck2 with gamma analysis of 2%/2mm and 10% threshold. The final DLG and transmission parameters for 6X were 0.5mm and 0.01, and 1.35mm and 0.02 for HD and SD MLCs respectively. Conclusion: This iterative approach of determining dosimetric properties of MLCs is viable for both SDMLC and HDMLC and multiple energies. This approach accurately and efficiently determines the values needed for commissioning MLCs when they are employed for modulated therapies.

60 APPLIED LIFE SCIENCES↗

SU-E-T-597: Parameterization of the Photon Beam Dosimetry for a Commercial Linear Accelerator

Purpose: In radiation therapy, accurate data acquisition of photon beam dosimetric quantities is important for (1) beam modeling data input into a treatment planning system (TPS), (2) comparing measured and TPS modelled data, (3) a linear accelerator’s (linac) beam characteristics quality assurance process, and (4) establishing a standard data set for data comparison, etcetera. Parameterization of the photon beam dosimetry creates a portable data set that is easy to implement for different applications such as those previously mentioned. The aim of this study is to develop methods to parameterize photon percentage depth doses(PDD), profiles, and total scatter output factors(Scp). Methods: Scp, PDDs and profiles for different field sizes (from 2×2 to 40×40cm{sup 2}), depths and energies were measured in a linac using a three-dimensional water tank. All data were smoothed and profile data were also centered, symmetrized and geometrically scaled. The Scp and PDD data were analyzed using exponential functions. For modelling of open and wedge field profiles, each side was divided into three regions described by exponential, sigmoid and Gaussian equations. The model’s equations were chosen based on the physical principles described by these dosimetric quantities. The equations’ parameters were determined using a least square optimization method with the minimal amount of measured data necessary. The model’s accuracy was then evaluated via the calculation of absolute differences and distance–to–agreement analysis in low gradient and high gradient regions, respectively. Results: All differences in the PDDs’ buildup and the profiles’ penumbra regions were less than 2 mm and 0.5 mm, respectively. Differences in the low gradient regions were 0.20 ± 0.20% and 0.50 ± 0.35% for PDDs and profiles, respectively. For Scp data, all differences were less than 0.5%. Conclusion: This novel analytical model with minimum measurement requirements proved to accurately calculate PDDs, profiles, and Scp for different field sizes, depths and energies.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-610: Phosphor-Based Fiber Optic Probes for Proton Beam Characterization

Purpose: To investigate feasibility of using fiber optics probes with rare-earth-based phosphor tips for proton beam radiation dosimetry. We designed and fabricated a fiber probe with submillimeter resolution (<0.5 mm3) based on TbF3 phosphors and evaluated its performance for measurement of proton beam including profiles and range. Methods: The fiber optic probe with TbF3 phosphor tip, embedded in tissue-mimicking phantoms was irradiated with double scattering proton beam with energy of 180 MeV. Luminescence spectroscopy was performed by a CCD-coupled spectrograph to analyze the emission spectra of the fiber tip. In order to measure the spatial beam profile and percentage depth dose, we used singular value decomposition method to spectrally separate the phosphors ionoluminescence signal from the background Cerenkov radiation signal. Results: The spectra of the TbF3 fiber probe showed characteristic ionoluminescence emission peaks at 489, 542, 586, and 620 nm. By using singular value decomposition we found the contribution of the ionoluminescence signal to measure the percentage depth dose in phantoms and compared that with measurements performed with ion chamber. We observed quenching effect at the spread out Bragg peak region, manifested as under-responding of the signal, due to the high LET of the beam. However, the beam profiles were not dramatically affected by the quenching effect. Conclusion: We have evaluated the performance of a fiber optic probe with submillimeter resolution for proton beam dosimetry. We demonstrated feasibility of spectral separation of the Cerenkov radiation from the collected signal. Such fiber probes can be used for measurements of proton beams profile and range. The experimental apparatus and spectroscopy method developed in this work provide a robust platform for characterization of proton-irradiated nanophosphor particles for ultralow fluence photodynamic therapy or molecular imaging applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parameterization of photon beam dosimetry for a linear accelerator

Purpose: In radiation therapy, accurate data acquisition of photon beam dosimetric quantities is important for (1) beam modeling data input into a treatment planning system (TPS), (2) comparing measured and TPS modeled data, (3) the quality assurance process of a linear accelerator’s (Linac) beam characteristics, (4) the establishment of a standard data set for comparison with other data, etcetera. Parameterization of the photon beam dosimetry creates a data set that is portable and easy to implement for different applications such as those previously mentioned. The aim of this study is to develop methods to parameterize photon beam dosimetric quantities, including percentage depth doses (PDDs), profiles, and total scatter output factors (S{sub cp}). Methods: S{sub cp}, PDDs, and profiles for different field sizes, depths, and energies were measured for a Linac using a cylindrical 3D water scanning system. All data were smoothed for the analysis and profile data were also centered, symmetrized, and geometrically scaled. The S{sub cp} data were analyzed using an exponential function. The inverse square factor was removed from the PDD data before modeling and the data were subsequently analyzed using exponential functions. For profile modeling, one halfside of the profile was divided into three regions described by exponential, sigmoid, and Gaussian equations. All of the analytical functions are field size, energy, depth, and, in the case of profiles, scan direction specific. The model’s parameters were determined using the minimal amount of measured data necessary. The model’s accuracy was evaluated via the calculation of absolute differences between the measured (processed) and calculated data in low gradient regions and distance-to-agreement analysis in high gradient regions. Finally, the results of dosimetric quantities obtained by the fitted models for a different machine were also assessed. Results: All of the differences in the PDDs’ buildup and the profiles’ penumbra regions were less than 2 and 0.5 mm, respectively. The differences in the low gradient regions were 0.20% ± 0.20% (<1% for all) and 0.50% ± 0.35% (<1% for all) for PDDs and profiles, respectively. For S{sub cp} data, all of the absolute differences were less than 0.5%. Conclusions: This novel analytical model with minimum measurement requirements was proved to accurately calculate PDDs, profiles, and S{sub cp} for different field sizes, depths, and energies.

61 RADIATION PROTECTION AND DOSIMETRY↗

How does C-VIEW image quality compare with conventional 2D FFDM?

Purpose: The FDA approved the use of digital breast tomosynthesis (DBT) in 2011 as an adjunct to 2D full field digital mammography (FFDM) with the constraint that all DBT acquisitions must be paired with a 2D image to assure adequate interpretative information is provided. Recently manufacturers have developed methods to provide a synthesized 2D image generated from the DBT data with the hope of sparing patients the radiation exposure from the FFDM acquisition. While this much needed alternative effectively reduces the total radiation burden, differences in image quality must also be considered. The goal of this study was to compare the intrinsic image quality of synthesized 2D C-VIEW and 2D FFDM images in terms of resolution, contrast, and noise. Methods: Two phantoms were utilized in this study: the American College of Radiology mammography accreditation phantom (ACR phantom) and a novel 3D printed anthropomorphic breast phantom. Both phantoms were imaged using a Hologic Selenia Dimensions 3D system. Analysis of the ACR phantom includes both visual inspection and objective automated analysis using in-house software. Analysis of the 3D anthropomorphic phantom includes visual assessment of resolution and Fourier analysis of the noise. Results: Using ACR-defined scoring criteria for the ACR phantom, the FFDM images scored statistically higher than C-VIEW according to both the average observer and automated scores. In addition, between 50% and 70% of C-VIEW images failed to meet the nominal minimum ACR accreditation requirements—primarily due to fiber breaks. Software analysis demonstrated that C-VIEW provided enhanced visualization of medium and large microcalcification objects; however, the benefits diminished for smaller high contrast objects and all low contrast objects. Visual analysis of the anthropomorphic phantom showed a measureable loss of resolution in the C-VIEW image (11 lp/mm FFDM, 5 lp/mm C-VIEW) and loss in detection of small microcalcification objects. Spectral analysis of the anthropomorphic phantom showed higher total noise magnitude in the FFDM image compared with C-VIEW. Whereas the FFDM image contained approximately white noise texture, the C-VIEW image exhibited marked noise reduction at midfrequency and high frequency with far less noise suppression at low frequencies resulting in a mottled noise appearance. Conclusions: Their analysis demonstrates many instances where the C-VIEW image quality differs from FFDM. Compared to FFDM, C-VIEW offers a better depiction of objects of certain size and contrast, but provides poorer overall resolution and noise properties. Based on these findings, the utilization of C-VIEW images in the clinical setting requires careful consideration, especially if considering the discontinuation of FFDM imaging. Not explicitly explored in this study is how the combination of DBT + C-VIEW performs relative to DBT + FFDM or FFDM alone.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP2-13: Spatial Accuracy Evaluation for Real-Time MR Guided Radiation Therapy Using a Novel Large-Field MRI Distortion Phantom

Purpose: Evaluate a large-field MRI phantom for assessment of geometric distortion in whole-body MRI for real-time MR guided radiation therapy. Methods: A prototype CIRS large-field MRI distortion phantom consisting of a PMMA cylinder (33 cm diameter, 30 cm length) containing a 3D-printed orthogonal grid (3 mm diameter rods, 20 mm apart), was filled with 6 mM NiCl{sub 2} and 30 mM NaCl solution. The phantom was scanned at 1.5T and 3.0T on a GE HDxt and Discovery MR750, respectively, and at 0.35T on a ViewRay system. Scans were obtained with and without 3D distortion correction to demonstrate the impact of such corrections. CT images were used as a reference standard for analysis of geometric distortion, as determined by a fully automated gradient-search method developed in Matlab. Results: 1,116 grid points distributed throughout a cylindrical volume 28 cm in diameter and 16 cm in length were identified and analyzed. With 3D distortion correction, average/maximum displacements for the 1.5, 3.0, and 0.35T systems were 0.84/2.91, 1.00/2.97, and 0.95/2.37 mm, respectively. The percentage of points with less than (1.0, 1.5, 2.0 mm) total displacement were (73%, 92%, 97%), (54%, 85%, 97%), and (55%, 90%, 99%), respectively. A reduced scan volume of 20 × 20 × 10 cm{sup 3} (representative of a head and neck scan volume) consisting of 420 points was also analyzed. In this volume, the percentage of points with less than (1.0, 1.5, 2.0 mm) total displacement were (90%, 99%, 100%), (63%, 95%, 100%), and (75%, 96%, 100%), respectively. Without 3D distortion correction, average/maximum displacements were 1.35/3.67, 1.67/4.46, and 1.51/3.89 mm, respectively. Conclusion: The prototype large-field MRI distortion phantom and developed software provide a thorough assessment of 3D spatial distortions in MRI. The distortions measured were acceptable for RT applications, both for the high field strengths and the system configuration developed by ViewRay.

60 APPLIED LIFE SCIENCES↗

Energy filtering–induced ultrahigh thermoelectric power factors in Ni 3 Ge

Traditional thermoelectric materials rely on low thermal conductivity to enhance their efficiency but suffer from inherently limited power factors. Innovative pathways to optimize electronic transport are thus crucial. Here, we achieve ultrahigh power factors in Ni 3 Ge-based systems through an unconventional thermoelectric materials design principle. When overlapping flat and dispersive bands are engineered to the Fermi level, charge carriers can undergo intense interband scattering, yielding an energy filtering effect similar to what has long been predicted in certain nanostructured materials. Via a multistep DFT-based screening method developed here, we find a family of L1 2 -ordered binary compounds with ultrahigh power factors up to 11 mW m −1 K −2 near room temperature, which are driven by an intrinsic phonon-mediated energy filtering mechanism. Our comprehensive experimental and theoretical study of these intriguing materials paves the way for understanding and designing high-performance scattering-tuned metallic thermoelectrics.

Science & Technology - Other Topics↗

Printed Assemblies of Inorganic Light-Emitting Diodes for Deformable and Semitransparent Displays

We have developed methods for creating microscale inorganic light-emitting diodes (LEDs) and for assembling and interconnecting them into unusual display and lighting systems. The LEDs use specialized epitaxial semiconductor layers that allow delineation and release of large collections of ultrathin devices. Diverse shapes are possible, with dimensions from micrometers to millimeters, in either flat or “wavy” configurations. Printing-based assembly methods can deposit these devices on substrates of glass, plastic, or rubber, in arbitrary spatial layouts and over areas that can be much larger than those of the growth wafer. Furthermore, the thin geometries of these LEDs enable them to be interconnected by conventional planar processing techniques. Displays, lighting elements, and related systems formed in this manner can offer interesting mechanical and optical properties.

42 ENGINEERING↗

Surface Plasmon Resonance and Aggregate Stability of Silver Nanoparticle Complexes with Chemotripsin

Extinction spectra, effective sizes, and aggregate stability of silver nanoparticles and nanocomplexes of silver nanoparticles with chymotrypsin obtained by the reactions of chemical reduction of silver nitrate using sodium borohydride as a reducing agent are studied. It is shown that silver nanoparticles obtained in the absence of chymotrypsin are aggregatively stable only at pH values immediately after synthesis. The placement of the synthesized silver nanoparticles in buffer solutions with pH values from 3.0 to 12.0 resulted in the appearance of a wide absorption band in the visible region of the spectrum, which is due to the agglomeration of silver nanoparticles, which appears to be the result of the destruction of the double electric layer formed by the ions making up sodium borohydride. The presence of chymotrypsin in the reaction medium resulted in significant spectral changes. Unlike silver nanoparticles synthesized in the absence of chymotrypsin, for nanocomplexes of silver nanoparticles with chymotrypsin with a change in pH, the shape of the extinction spectra and the position of the surface plasmon resonance band were preserved, while nanocomplexes of silver nanoparticles with chymotrypsin retained the aggregative stability in solutions in the pH range from 3.0 to 12.0 within a month. The observed stabilization effect of silver nanoparticles over a wide pH range induced by the presence of chymotrypsin in the reaction medium can be used further to develop methods for immobilizing enzymes on nanoparticles of biogenic elements and for creating polyfunctional pharmaceuticals, in which the components of nanocomplexes have different biological activity.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

X-ray diffraction study of BaTiO{sub 3} single crystals before and after fast-neutron irradiation

The neutron irradiation of ferroelectrics is efficiently used to form structural states that cannot be obtained by conventional technologies. To date, the effect of neutron irradiation on the structure and properties of BaTiO{sub 3} has been studied for only ceramic materials. We have considered the influence of fast-neutron irradiation (F = 1 × 10{sup 17} cm{sup −2}) on the structure and properties of BaTiO{sub 3} single crystals for the first time. The structural changes occurring in irradiated BaTiO{sub 3} and their correlation with the behavior of dielectric and nonlinear optical characteristics are analyzed with the aid of a specially developed method for taking into account the experimental correction to diffuse scattering. Neutron irradiation to the aforementioned dose retains the polar structure of the material and only slightly changes atomic displacements. The radiationinduced structural changes occur according to the high-temperature type to form a structure similar to the cubic modification of unirradiated BaTiO{sub 3} crystal.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Construction of a dynamical matrix for an HCP crystal using phonon data at the symmetry points of the Brillouin zone and elastic constants

General analytical expressions are obtained for the dynamical matrix D(k) and the elastic constants C{sub ik} in an HCP crystal in terms of the Born-von Karman (BvK) parameters. An analytical method is proposed for constructing D(k) on the basis of data about the phonon frequencies {omega}{sub i}(N) at the symmetry points of the Brillouin zone and the elastic constants C{sub ik}. A number of relations between the values of {omega}{sub i}(N) and C{sub ik} are presented for conventional interaction models. It is shown that the standard method for determining BvK parameters by fitting them to experimental phonon spectra in HCP lattices is, as a rule, ambiguous, whereas the analytical method proposed allows one to find all the solutions of the problem. The methods developed are illustrated by the construction of dynamical matrices for Tb, Sc, Ti, and 0008.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗