Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurement errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Evaluation of the LOFTID Flight Thermocouple Measurements

The Flexible Thermal Protection System (FTPS) on NASA’s Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) vehicle was instrumented with thermocouples (TC) to measure the in-depth thermal response during entry into Earth’s atmosphere. Accurate flight temperature measurements are critical for verifying vehicle performance during the flight test and reducing uncertainties in the thermal models. The deployable nature of inflatable decelerator technology presents challenges, namely the TCs need to be compactable, cannot damage the FTPS nor the inflatable structure, and need to be able to withstand high temperatures and large thermal gradients over significant running lengths. As previously reported, an extensive ground-test campaign was conducted prior to flight to inform the selection of the LOFTID FTPS TCs which minimized all known potential error sources. Overall, the resulting flight FTPS TC measurements were exceptionally clean throughout the atmospheric entry heat pulse. However, a few of the FTPS TCs still exhibited electrical shorting or other anomalous behavior. This paper presents the flight measurements made by the LOFTID FTPS TCs, identifies anomalous behavior, and discusses potential explanations for the causes of the anomalous behavior. Lastly, recommendations to further mitigate TC measurement error on future Hypersonic Inflatable Aerodynamic Decelerator (HIAD) missions are provided.

Ruth A Miller↗

Skeletal and body composition evaluation

Research on radiation detectors for absorptiometry; analysis of errors affective single photon absorptiometry and development of instrumentation; analysis of errors affecting dual photon absorptiometry and development of instrumentation; comparison of skeletal measurements with other techniques; cooperation with NASA projects for skeletal evaluation in spaceflight (Experiment MO-78) and in laboratory studies with immobilized animals; studies of postmenopausal osteoporosis; organization of scientific meetings and workshops on absorptiometric measurement; and development of instrumentation for measurement of fluid shifts in the human body were performed. Instrumentation was developed that allows accurate and precise (2% error) measurements of mineral content in compact and trabecular bone and of the total skeleton. Instrumentation was also developed to measure fluid shifts in the extremities. Radiation exposure with those procedures is low (2-10 MREM). One hundred seventy three technical reports and one hundred and four published papers of studies from the University of Wisconsin Bone Mineral Lab are listed.

Mazess, R. B.↗

Gain Instabilities in Photomultipliers: How Accurate are Photon Counting Measurements?

Experiments performed on five commercially available photomultiplier tubes indicate that gain instabilities can be an important source of error in photon counting measurements at the 1% level. It is shown that the error cannot be significantly reduced by standard differential measurement techniques. Analysis of time variations in the pulse height distribution is shown to be a sensitive diagnostic tool for the measurement of gain variations. Using this technique it is found that gain variations occur at counting rates as low as 100 Hz. It is argued that such errors will be present at some level in all tubes. Several calibrating schemes capable of reducing the error to below the 0.1% level are discussed.

Rosen, W. A.↗

Trends in Downwelling Longwave Radiance Over the Southern Great Plains

Downwelling longwave radiation is an important part of the surface energy budget. Spectral trends in the downwelling longwave radiance (DLR) provide insight into the radiative drivers of climate change. In this research, we process and analyze a 23-year DLR record measured by the Atmospheric Emitted Radiance Interferometer (AERI) at the U.S. Department of Energy Atmospheric Radiation Program Southern Great Plains (SGP) site. Two AERIs were deployed at SGP with an overlapping observation period of about 10 years, which allows us to examine the consistency and accuracy of the measurements and to account for discrepancies between them due to errors associated with the instruments themselves. We then analyzed the all-sky radiance trends in DLR, which are associated with the surface warming trend at SGP during this same period and also the complex changes in meteorological conditions. For instance, the observed radiance in the CO2 absorption band follows closely the near-surface air temperature variations. The significant positive radiance trends in weak absorption channels, such as in the wings of the CO 2 band and in the weak absorption channels in the H 2 O vibration-rotational band, show earlier detectability of climate change. The magnitude of the radiance trend uncertainty in the DLR record mainly results from internal climate variability rather than from measurement error, which highlights the importance of continuing the DLR spectral measurements to unambiguously detect and attribute climate change.

54 ENVIRONMENTAL SCIENCES↗

Manufactured solutions for an electromagnetic slot model

The accurate modeling of electromagnetic penetration is an important topic in computational electromagnetics. Electromagnetic penetration occurs through intentional or inadvertent openings in an otherwise closed electromagnetic scatterer, which prevent the contents from being fully shielded from external fields. To efficiently model electromagnetic penetration, aperture or slot models can be used with surface integral equations to solve Maxwell's equations. A necessary step towards establishing the credibility of these models is to assess the correctness of the implementation of the underlying numerical methods through code verification. Surface integral equations and slot models yield multiple interacting sources of numerical error and other challenges, which render traditional code-verification approaches ineffective. In this paper, we provide approaches to separately measure the numerical errors arising from these different error sources for the method-of-moments implementation of the electric-field integral equation with a slot model. Finally, we demonstrate the effectiveness of these approaches for a variety of cases.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Accurate equation of state of H 2 – He binary mixtures up to 5.4 GPa

Brillouin scattering spectroscopy has been used to obtain an accurate (<1%) ρ-P equation of state (EOS) of 1:1 and 9:1 H 2 -He molar mixtures from 0.5 to 5.4 GPa at 296 K. Our calculated equations of state indicate close agreement with the experimental data right to the freezing pressure of hydrogen at 5.4 GPa. The measured velocities agree on average, within 0.5%, of an ideal mixing model. The ρ-P EOSs presented have a standard deviation of under 0.3% from the measured densities and under 1% deviation from ideal mixing. Furthermore, a detailed discussion of the accuracy, precision, and sources of error in the measurement and analyses of our equations of state is presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optoelectronic Tool Measures Steps And Gaps Between Tiles

Optoelectronic tool measures gaps between tiles and steps between faces of tiles. Eliminates need for difficult, tedious, time-consuming, and error-prone manual measurements. Automates measurements of steps and gaps to within 0.006 in. and records data automatically. Developed for inspecting thermal-insulation tiles on Space Shuttle. Adaptable to inspection of any other settings where steps and gaps critical.

Davis, Dick↗

Comparison of Simulated Contrast Performance of Different Phase Induced Amplitude Apodization (PIAA) Coronagraph Configurations

We compare the broadband contrast performances of several Phase Induced Amplitude Apodization (PIAA) coronagraph configurations through modeling and simulations. The basic optical design of the PIAA coronagraph is the same as NASA's High Contrast Imaging Testbed (HCIT) setup at the Jet Propulsion Laboratory (JPL). Using a deformable mirror and a broadband wavefront sensing and control algorithm, we create a "dark hole" in the broadband point-spread function (PSF) with an inner working angle (IWA) of 2(f lambda/D)(sub sky). We evaluate two systems in parallel. One is a perfect system having a design PIAA output amplitude and not having any wavefront error at its exit-pupil. The other is a realistic system having a design PIAA output amplitude and the measured residual wavefront error. We also investigate the effect of Lyot stops of various sizes when a postapodizer is and is not present. Our simulations show that the best 7.5%-broadband contrast value achievable with the current PIAA coronagraph is approximately 1.5x10(exp -8).

adaptive optics↗

Characterization of Infrared Optical Motion Tracking System in NASA's Simulated Lunar Operations (SLOPE) Laboratory

This work characterizes the accuracy of a 16 camera OptiTrack motion tracking system installed in NASA Glenn Research Center's Simulated Lunar Operations (SLOPE) laboratory. The position of a rigid body mounted on a motorized linear stage is compared to its position reported by the motion tracking system as it travels through the facility's 777m$^3$ capture volume of interest. Experiments show that the mean error reported by the motion tracking system for the aggregate capture volume is in-line with independent measurements collected using the motion stage. Error within regions of the capture volume exceed the mean error reported by the motion tracking system, likely due to occlusion, and suggests that additional cameras should be used to increase measurement accuracy in these regions. Overall, results show that error values reported by the motion tracking system are representative of the measurement error in a collected data set and validates the system's use for characterizing the mobility and tractive performance of robots, rovers, and other vehicles for planetary exploration.

Motion capture↗

Revised astrometric calibration of the Gemini Planet Imager

We present a revision to the astrometric calibration of the Gemini Planet Imager (GPI), an instrument designed to achieve the high contrast at small angular separations necessary to image substellar and planetary-mass companions around nearby, young stars. We identified several issues with the GPI data reduction pipeline (DRP) that significantly affected the determination of the angle of north in reduced GPI images. As well as introducing a small error in position angle measurements for targets observed at small zenith distances, this error led to a significant error in the previous astrometric calibration that has affected all subsequent astrometric measurements. We present a detailed description of these issues and how they were corrected. We reduced GPI observations of calibration binaries taken periodically since the instrument was commissioned in 2014 using an updated version of the DRP. These measurements were compared to observations obtained with the NIRC2 instrument on Keck II, an instrument with an excellent astrometric calibration, allowing us to derive an updated plate scale and north offset angle for GPI. This revised astrometric calibration should be used to calibrate all measurements obtained with GPI for the purposes of precision astrometry.

79 ASTRONOMY AND ASTROPHYSICS↗

Systematic Error Cancellation for a Four-Port Interferometric Polarimeter

The Primordial Inflation Explorer (PIXIE) is an Explorer-class mission concept to measure the gravitational-wave signature of primordial inflation through its distinctive imprint on the linear polarization of thecosmic microwave background (CMB). Its optical system couples a polarizing Fourier transform spectrometerto the sky to measure the differential signal between orthogonal linear polarization states from two co-pointedbeams on the sky. The double differential nature of the four-port measurement mitigates beam-related systematic errors common to the two-port systems used in most CMB measurements. Systematic errors coupling unpolarized temperature gradients to a false polarized signal cancel to first order for any individual detector. Thiscommon-mode cancellation is performed optically, prior to detection, and does not depend on the instrumentcalibration. Systematic errors coupling temperature to polarization cancel to second order when comparing signals from independent detectors. We describe the polarized beam patterns for PIXIE and assess the systematicerror for measurements of CMB polarization.

Kogut, Alan J.↗

Noninvasive Investigation of Bone Adaptation in Humans Cumulative Daily Mechanical Loading

Our Research Objective is to measure the spatial distribution of bone mass throughout the entire internal volume of a bone such as the human calcaneus or heel bone. Currently, x-ray computed tomography (CT) is the only practical three-dimensional imaging technology capable of measuring bone density within small contiguous volumetric regions of a bone. spectrum of energies in the x-ray beam producing the image. We have developed a computational method of correcting these errors, provided the x-ray spectrum is known or measured (Yan et al., 2000). Monitoring serial changes in volumetric bone density with age, disuse, exercise or A CT image contains measurement errors in bone density caused by the broad drug therapy also requires accurate image registration.

Whalen, Robert T.↗

Ionospheric Studies with the Differential Doppler Technique

This report is essentially a review of the measurements related to the ionosphere utilizing the differential Doppler technique. A brief study of the theory is presented, in which the error incurred in measurements of ionospheric electron content, caused by the assumption of common-path propagation, is shown as a function of the zenith angle of observation for different values of the critical frequency foF2. Some measurements of electron densities, electron content, horizontal gradients, irregularities, and magnetic-storm effects are discussed. Comments are also made about the method of combining the differential Doppler with the Faraday rotation measurements to establish a necessary constant of integration in the measurements made with satellites. It is concluded that the differential Doppler technique, with harmonically related frequencies transmitted to or from rockets or satellites, can provide accurate information about the electron density or electron content of the medium, and that the knowledge of these quantities is valuable in understanding the morphology of the ionospheric processes.

IONOSPHERE↗

Nearshore coastal mapping

Two test sites of different water quality and bottom topography were used to test for maximum water depth penetration using the Skylab S-192 MSS for measurement of nearshore coastal bathymetry. Sites under investigation lie along the Lake Michigan coastline where littoral transport acts to erode sand bluffs and endangers developments along 1,200 miles of shore, and on the west coast of Puerto Rico where unreliable shoal location and depth information constitutes a safety hazard to navigation. The S-192 and S-190A and B provide data on underwater features because of water transparency in the blue/green portion of the spectrum. Depth of 20 meters were measured with the S-192 in the Puerto Rico test site. The S-190B photography with its improved spatial resolution clearly delineates the triple sand bar topography in the Lake Michigan test site. Several processing techniques were employed to test for maximum depth measurement with least error. The results are useful for helping to determine an optimum spectral bandwidth for future space sensors that will increase depth measurements for different water attenuation conditions where a bottom reflection is detectable.

Polcyn, F. C.↗

Subjective rating scales as a workload

A multidimensional bipolar-adjective rating scale is employed as a subjective measure of operator workload in the performance of a one-axis tracking task. The rating scale addressed several dimensions of workload, including cognitive, physical, and perceptual task loading as well as fatigue and stress effects. Eight subjects performed a one-axis tracking task (with six levels of difficulty) and rated these tasks on several workload dimensions. Performance measures were tracking error RMS (root-mean square) and the standard deviation of control stick output. Significant relationships were observed between these performance measures and skill required, task complexity, attention level, task difficulty, task demands, and stress level.

Bird, K. L.↗

Analysis of shuttle oscillation in the Mach Number = 1.7 to Mach Number = 1.0 range

The first five flights of the Space Transportation System (STS) have exhibited unexpected lateral oscillations in the Mach Number = 1.7 to Mach Number = 1.0 region of the descent trajectory. These oscillations can be split into two parts: a predominantly rolling oscillation referred to as the quarter hertz motion and a long-priod, large-amplitude oscillation in sideslips, roll rate, and yaw rate. These motions are analyzed in this paper in order to determine their source and the mechanism driving them. They will first be examined to determine how much of the motion can be explained using the set of equations that contain linear aerodynamic parameters. Then differences between measured moments and those calculated using linear aerodynamics which are considered to be due to unmodeled moments will be exained. Possible error sources such as not inluding nonlinear aerodynamics in the vehicle model, measurement errors, and the effect of pressure gradients will be considered. Based on these analyses, conclusions as to the nature and cause of the Shuttle lateral oscillations will be drawn.

Suit, W. T.↗

Comparison of Commonly-Used Microwave Radiative Transfer Models for Snow Remote Sensing

This paper reviews four commonly-used microwave radiative transfer models that take different electromagnetic approaches to simulate snow brightness temperature (T(sub B)): the Dense Media Radiative Transfer - Multi-Layer model (DMRT-ML), the Dense Media Radiative Transfer - Quasi-Crystalline Approximation Mie scattering of Sticky spheres (DMRT-QMS), the Helsinki University of Technology n-Layers model (HUT-nlayers) and the Microwave Emission Model of Layered Snowpacks (MEMLS). Using the same extensively measured physical snowpack properties, we compared the simulated T(sub B) at 11, 19 and 37 GHz from these four models. The analysis focuses on the impact of using different types of measured snow microstructure metrics in the simulations. In addition to density, snow microstructure is defined for each snow layer by grain optical diameter (Do) and stickiness for DMRT-ML and DMRT-QMS, mean grain geometrical maximum extent (D(sub max)) for HUT n-layers and the exponential correlation length for MEMLS. These metrics were derived from either in-situ measurements of snow specific surface area (SSA) or macrophotos of grain sizes (D(sub max)), assuming non-sticky spheres for the DMRT models. Simulated T(sub B) sensitivity analysis using the same inputs shows relatively consistent T(sub B) behavior as a function of Do and density variations for the vertical polarization (maximum deviation of 18 K and 27 K, respectively), while some divergences appear in simulated variations for the polarization ratio (PR). Comparisons with ground based radiometric measurements show that the simulations based on snow SSA measurements have to be scaled with a model-specific factor of Do in order to minimize the root mean square error (RMSE) between measured and simulated T(sub B). Results using in-situ grain size measurements (SSA or D(sub max), depending on the model) give a mean T(sub B) RMSE (19 and 37 GHz) of the order of 16-26 K, which is similar for all models when the snow microstructure metrics are scaled. However, the MEMLS model converges to better results when driven by the correlation length estimated from in-situ SSA measurements rather than D(sub max) measurements. On a practical level, this paper shows that the SSA parameter, a snow property that is easy to retrieve in-situ, appears to be the most relevant parameter for characterizing snow microstructure, despite the need for a scaling factor.

Snow↗

Error analysis and corrections to pupil diameter measurements with Langley Research Center's oculometer

Factors that can affect oculometer measurements of pupil diameter are: horizontal (azimuth) and vertical (elevation) viewing angle of the pilot; refraction of the eye and cornea; changes in distance of eye to camera; illumination intensity of light on the eye; and counting sensitivity of scan lines used to measure diameter, and output voltage. To estimate the accuracy of the measurements, an artificial eye was designed and a series of runs performed with the oculometer system. When refraction effects are included, results show that pupil diameter is a parabolic function of the azimuth angle similar to the cosine function predicted by theory: this error can be accounted for by using a correction equation, reducing the error from 6% to 1.5% of the actual diameter. Elevation angle and illumination effects were found to be negligible. The effects of counting sensitivity and output voltage can be calculated directly from system documentation. The overall accuracy of the unmodified system is about 6%. After correcting for the azimuth angle errors, the overall accuracy is approximately 2%.

Fulton, C. L.↗