Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Virtual Metering for Monitoring Building Energy Consumption

The United States Department of Energy (DOE) has standard metering requirements of commercial buildings for optimizing energy performance. The guiding principles are to continuously track and optimize energy performance and install building-level meters for electricity, natural gas, and steam. Some buildings at Los Alamos National Laboratory (LANL) have physical submeters monitoring their energy consumption, but these meters have proven to be unreliable. And, in most cases, replacing them has proven to be a slow process. Installing new submeters also requires a temporary lockout of the circuit on which they are being installed. Many buildings at LANL contain laboratories with ongoing experiments or data centers, which makes an equipment power outage nearly impossible to plan. This inability to plan power outages results in long-term submeter failures. Although most submeters are eventually replaced, failures lead to missing consumption data for some unpredictable, extended time. A building automation system (BAS) is a system that provides control and monitoring on a building to maintain the operational performance of the building and occupancy comfort. Many buildings at LANL currently have a BAS, and all new renovations and installs will include installing a BAS if one does not already exist. The intended purpose for a BAS is primarily to monitor the health and efficiency of a building; however, it is also possible to calculate equipment power and energy consumption using BAS information. This project aims to use virtual meters to monitor building energy consumption as a cost-effective and minimally labor-intensive alternative to installing physical submeters. The fault detection and diagnostics tool, SkySpark, provides a centralized database for all the data from the various BAS that are active at LANL. This data includes the information that is needed to create virtual meters for heating, ventilating, and air conditioning (HVAC) systems in most buildings, including heating and cooling loads. 9 This report begins with a detailed summary of the project, including the reasoning, procedure, and results. The specific processes of creating the various virtual meters are then identified. Then the limitations are discussed. And, lastly, the results and future potential are presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Photonic Doppler Velocimetry for Valve Analysis and Surveillance

This study is an experimental evaluation to measure and surveil the velocity of stainless steel (Carpenter 455) pistons within a forged 21-6-9 stainless steel valve body. The velocity of the piston “stroke” will be identified using Photonic Doppler Velocimetry (PDV). The piston velocity will be the measured variable of interest. The outcome of this testing series provides further understanding to whether the extracted piston velocity can provide enough information to determine valve integrity. PDV has been identified as a diagnostic of interest as it can detect surface motion at high speeds with reliable accuracy. Through preliminary studies conducted with velocity interferometer system for any reflector (VISAR), the velocity of the piston is expected to stroke with a speed of 135 m/s. The PDV technique is much more reliable and repeatable than the VISAR technique because of its high-speed precision and accuracy, so it will not only validate the preliminary data, but also provide a testing technique that is capable of being used in future valve qualification efforts. The initial testing was completed using valves that were assembled per qualified procedures in a pristine condition. These initial tests were conducted to provide baseline data. This baseline data was then compared to data collected from valves where man-made defects were introduced. These defects are discussed in later sections. Lastly, actuators used to operate the valves were loaded with varied amounts of high explosives to identify if velocity is a function of the amount of explosive in an actuator. These parameters were adjusted to conclusively determine and identify if PDV can be used as a method to assess valve integrity. It was concluded through the testing discussed in this paper that in fact, PDV is capable of measuring the differences in piston velocities based on varied parameters. As far as understanding the PDV accuracy of the measured differences, this is ongoing and will have to be assessed in continued testing series.

42 ENGINEERING↗

Enabling Realistic Communications Evaluations for ADMS

Increasing penetration levels of inverter-based distributed energy resources (DERs) in distribution systems are creating challenges in system operation. Currently, wired or proprietary wireless communications are used by advanced distribution management systems (ADMS) to detect the state of the system and control the DERs for optimal operation. Wireless communications are an alternative solution that can enable connectivity between the dispersed assets used in distribution system applications. As demand for the seamless integration of distributed energy resources (DERs) continues to increase, proper networking and communications systems are becoming important to support the DER infrastructure. This report summarizes validation of a private wireless LTE network in a laboratory environment. The purpose of this work is to 1) demonstrate the effectiveness of private wireless LTE communication for grid applications and 2) provide a means of evaluating latency and overall performance of wireless communication in grid applications. First, private wireless LTE communication was validated in a direct transfer trip relaying scenario as an example of one-way communications using grid equipment. This study provided a baseline understanding of the variation in latency for seven different kinds of wireless scenarios shown in Figure A below. As expected, weak (attenuated) wireless signal-based communication yielded the widest ranges in latency. When higher priority was set for the trip signal communication, this resulted in lower latency in communication timing. In the final phase of this project, the private wireless LTE network was validated using two-way communications in an advanced distribution management system (ADMS) testbed which was developed in the ESIF at NREL. The purpose of this was to study the impact of wireless communication on grid performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Open Source Evaluation Framework for Solar Forecasting

The Solar Forecast Arbiter is an open-source evaluation framework for solar forecasting. The framework enables evaluations of solar irradiance, solar power, and net-load forecasts that are impartial, repeatable and auditable. The Solar Forecast Arbiter addresses stakeholder-informed use cases including evaluation of forecast skill, comparisons to reference data sets, private forecast trials, and evaluation of probabilistic forecast skill. The framework includes a data validation toolkit, reference data sources, data privacy protocols, and benchmark forecast capabilities for intra-hour and day ahead forecast horizons. Reports and metrics communicate the relative merits of the test and benchmark forecasts. The reports are created from standardized templates and include graphics for qualitatively evaluating deterministic and probabilistic forecasts and standard metrics for quantitatively evaluating forecasts. The Solar Forecast Arbiter is designed to support all solar forecasting stakeholders, including Solar Forecasting 2 Topic Area 2 and Topic Area 3 teams.

14 SOLAR ENERGY↗

Progress in developing a superconducting accelerator for efficient eBeam and X-ray production

The PIP-II Accelerator is an 800 MeV superconducting Linac in the injection chain of the Fermilab accelerator complex. The LLRF systems for the 125 cavities which include a few normal conducting cavities in the warm front-end section, use a variety of LLRF hardware components and sub-systems that are part of the timing and synchronization system. This includes a master oscillator and phase averaging reference line, a beam pattern generator to enable beam transfer between non-harmonic RF systems and beam loading compensation systems synchronized to a start of beam trigger. The timing signals are based on a 650 MHz clock with manchester encoded event information and data provided over optical fiber. The timing and synchronization systems and their performance parameters will be described here.

43 PARTICLE ACCELERATORS↗

Timing and Synchronization in the LLRF systems of the Fermilab PIP-II Linac

The PIP-II Accelerator is an 800 MeV superconducting Linac in the injection chain of the Fermilab accelerator complex. The LLRF systems for the 125 cavities which include a few normal conducting cavities in the warm front-end section, use a variety of LLRF hardware components and sub-systems that are part of the timing and synchronization system. This includes a master oscillator and phase averaging reference line, a beam pattern generator to enable beam transfer between non-harmonic RF systems and beam loading compensation systems synchronized to a start of beam trigger. The timing signals are based on a 650 MHz clock with manchester encoded event information and data provided over optical fiber. The timing and synchronization systems and their performance parameters will be described here.

Varghese, Philip↗

Spread Spectrum Time Domain Reflectometry (SSTDR) Digital Twin Simulation of Photovoltaic Systems for Fault Detection and Location

Utilizing spread spectrum time domain reflectometry (SSTDR) to detect, locate, and characterize faults in photovoltaic (PV) systems is examined in this paper. We present a method to obtain the model parameters that are needed to produce digital twin SSTDR responses for PV systems. The digital twin SSTDR responses could be used to predict faults within the PV systems. Here, the model parameters are the reflection and transmission coefficients at each impedance discontinuity in the PV system along with the propagation coefficients across each PV cable segment. We obtain model parameter by applying inverse modeling techniques to experimental SSTDR data associated with PV systems. Our model parameters can be used in any digital twin simulation method for modeling reflectometry in frequency-dependent and complex loads. For validation, we used the model parameters in a graph network simulation engine and adapted it to be used for SSTDR digital twin simulations in PV systems. We produced simulations for 0 to 10 PV modules connected in series. We also simulated SSTDR responses for open circuit disconnections in a PV setup containing 10 PV modules in series. Results show that all but one simulated disconnect locations match experimental disconnection locations of the same setup with an error of less than 5%.

14 SOLAR ENERGY↗

Electric Grid Visualization: Hourly Generation, Load, Unserved Load, and Locational Marginal Prices during a 2018 Heatwave

Visualization of hourly generation, load, unserved load, and locational marginal energy prices in the western United States during a July 22-28 heatwave event in 2018. In addition to hourly time series data of each of the parameters, choropleth maps showing the hourly value for each balancing authority are provided as well as a county-level choropleth map of temperature.

Mongird, Kendall (ORCID:0000000328077088)↗

Hierarchical Resilience Planning for Networked Microgrids: A Case Study of Puerto Rico

Microgrids can be designed to enhance the energy resilience of communities and critical infrastructures, such as hospitals, data centers, and communication networks, which are vulnerable to frequent weather-related disruption. Coordinating multiple microgrids in a network can leverage the geographical diversity of load and generation resources while enabling resilient and cost-effective planning of the distribution system. Designing a networked microgrid is complex, involving intricate technical assessment, cost-benefit analysis, site-specific requirements, and the evaluation of existing resources. Therefore, this paper proposes a hierarchical resilience planning framework and performs an extensive techno-economic analysis for the design of a networked microgrid. Hierarchical resilience planning involves technology sizing at an individual community level to meet the critical load and satisfy resilience criteria, and resource optimization at networked microgrid level to provide a higher level of resilience and energy adequacy. A real-world case of Puerto Rico's cooperative microgrid “Microrred de la Montaña” is investigated considering localized electricity tariffs, site-specific demand profiles, solar generation, and existing hydro resources. Multiple optimization scenarios are developed based on the resiliency requirement to estimate the capacity of solar photovoltaic and battery energy storage (BES) to be installed at each substation. The results provide the optimal sizing for individual community and networked microgrid to withstand 1day and 3-day outages along with the criteria for critical load.

13 - HYDRO ENERGY↗

Specification of EBR-II Fabricated Fuel Diameter Data

All IFR EBR-II fuel pins were fabricated at one of the related fuel fabrication facilities at Argonne National Laboratory-West, at the EBR-II site [1]. U-Pu-Zr experimental pins were fabricated at the Experimental Fuels Laboratory (EFL), which was established in April of 1984 after the positive acceptance of the IFR concept, while the U-Zr experimental pins were fabricated at the Fuel Manufacturing Facility (FMF), along with the driver fuel pins [2]. The injection-casting fabrication process is described in detail in ref [1]. All the fuel pins that were loaded into EBR-II were examined after fabrication to ensure that they met the design dimensional requirements and tolerances prior to assembly. Fuel slug diameter was measured with either a laser profilometer (at FMF) or a hand micrometer (at EFL), at a minimum of 1-inch intervals over the length of the fuel slug, as shown in Figure 1 [2]. In all cases the average fuel diameter is reported, in some cases with additional summary statistics (e.g., minimum, maximum), and in rare cases the complete record of axially-varying fuel diameters is available. It should be noted that in cases where axial varying data is available, in general the orientation of the slug was not recorded or carried over to loading of the pin, so a diameter measurement at the bottom of the fabricated slug does not necessarily correspond to the bottom of the loaded slug, as it may have been loaded in either orientation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

4D Imaging of ZnO-Coated Nanoporous Al 2 O 3 Aerogels by Chemically Sensitive Ptychographic Tomography: Implications for Designer Catalysts

The 3D chemical structure (4D spectromicroscopy) of nanoporous Al 2 O 3 aerogels coated with ZnO by atomic layer deposition (ALD) was studied by multienergy scanning transmission X-ray microscopy. These materials are representative of a class of designer catalysts in which the nanoporous support is prepared separately from the active catalyst material, which is subsequently introduced by ALD, thereby allowing independent optimization of the morphology, chemistry, and spatial distribution of the support and catalyst. The samples studied were prepared by Ga ion and Xe plasma focused ion beam (FIB) milling as well as drop casting from water suspension. Zn L and Al K edge spectra of six samples with three different ZnO loadings were measured to investigate how loading and different sample preparation methods affect the 3D distribution of the ZnO and Al 2 O 3 . Scanning transmission X-ray microscopy (STXM) and ptychographic imaging at two energies each at the Zn L 3 and Al K edge were measured. The ptychography data were analyzed by using the SHARP reconstruction code to generate quantitative 2D chemical maps of the Al 2 O 3 and the ZnO. The STXM and ptychography maps were then measured at a sequence of tilt angles, covering up to 160° of rotation. The 3D structure of the ZnO and Al 2 O 3 was derived from the tilt series data by tomographic reconstruction using a compressed sensing algorithm. A twodimensional spatial resolution (half-period) of 6 nm, measured by Fourier ring correlation, and a 3D spatial resolution (half-period) of 9 nm, measured by Fourier shell correlation, were achieved when using the COSMIC beamline at the Advanced Light Source (ALS). The results show that for all of the ZnO loadings studied there is nonuniform coverage of the ZnO on the Al 2 O 3 aerogel framework. In addition, we found that both FIB methods create sample artifacts, although the distortion was less with Xe plasma than Ga ion FIB.

36 MATERIALS SCIENCE↗

End-Use Savings Shapes Upgrade Package Documentation: Wall and Roof Insulation and New Windows

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Window Replacement, Exterior Wall Insulation, and Roof Insulation, which we will refer to collectively as the "High Efficiency Envelope" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

End-Use Savings Shapes Upgrade Package Documentation: LED Lighting, HP-RTU and ASHP-Boiler

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Light Emitting Diode (LED) Lighting, Heat Pump Rooftop Unit (RTU) (HP-RTU), and Air-Source Heat Pump (ASHP) Boiler, which we will refer to collectively as the "Interior Lighting and Heat Pump" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Enhancing SRF cavity stability and minimizing detuning with data-driven resonance control based on dynamic mode decomposition

Effective resonance control of superconducting radio frequency (SRF) cavities is critical for large machines like LCLS-II, as failure to achieve proper control can result in increased RF power consumption, higher cryogenic heat loads, and increased costs. To address this challenge, we have developed a machine learning (ML) model based on the dynamic mode decomposition method to represent the forced cavity dynamics. Using this model, we designed a model predictive controller (MPC) and demonstrated through simulation that the MPC can effectively stabilize the amplitude and phase of SRF cavities using only a frequency actuator, even in the presence of multiple mechanical modes. The lightweight and explicit ML model makes the controller suitable for direct implementation on field-programmable gate arrays, unlocking the full potential of SRF linacs like LCLS-II, enabling higher beam power and energy, and also serving as an advanced motion controller for various applications, such as photon beamlines and storage rings.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterization of wind conditions and impact on wind loading at an operational parabolic trough concentrating solar power plant using LiDAR observations

Wind loading is a major factor influencing the structural design costs of Concentrating Solar Power (CSP) collector systems, including heliostats and parabolic troughs. Traditionally, these designs have been based on wind-tunnel data, which often fail to accurately represent the dynamic effects experienced at full scale. This study presents a first-of-its-kind experimental characterization of wind conditions within an operational parabolic-trough CSP power plant focusing specifically on using lidar observations. The lidar observations give a unique opportunity to provide insights into wind flow conditions deep within the trough arrays. Our results suggest that (1) after being blocked by the first few rows, the wind speed above the troughs recovers to 73% of its inflow magnitude as it flows further over the trough field due to enhanced turbulent mixing and (2) due to the wind speed recovery, troughs in the interior field will likely experience higher shear-induced turning moments compared those at the front. The conclusions from this work stress the importance of better understanding the wind patterns and interior wind loads when designing solar collectors and highlights the need for more interior load measurements in the future field campaigns.

17 WIND ENERGY↗

Using Best Basis Inventory Data to Direct Strategies for Real-Time Monitoring of Hanford High Level Waste

The proposed Direct Feed High Level Waste (DFHLW) approach for processing high-level tank waste at Hanford is intended to reduce processing time by bypassing the Pretreatment Facility and transferring waste directly from the tank farm to the WTP HLW vitrification facility. This processing strategy could reduce or eliminate the washing and leaching steps that would have occurred in the Pretreatment facility. Operation of the vitrification facility is subject to chemical and radiological limits protecting safety (e.g. Waste Acceptance Criteria, or WACs) and process quality (e.g. Process Control Limits, or PCLs). Without washing and leaching, there is a greater risk of exceeding the WACs and PCLs. Hanford process engineers have devised blending strategies based on known chemical and radiological composition, volumes, and solids loadings of individual layers within each waste tank. These blending campaigns succeed in predicting a processing strategy that does not exceed the WACs and PCLs. However, the calculations do not ascribe uncertainties to the tank analysis data, quantities of material taken from the tanks to make the blend, or potential for mixing of layers within tanks. In order to confirm that a process strategy is working, it would be advantageous to have inline or at-line analytical instrumentation installed in the processing facilities that deliver measurement results in real time.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Demonstration of NREL Modeling Capability to Design the Next Generation of Floating Offshore Wind Turbines with Stiesdal and Magellan Wind (Cooperative Research and Development Final Report)

This Technology Commercialization Fund (TCF) CRADA involved demonstration of NREL modeling capability using OpenFAST (formerly known as FAST) to design the next generation of floating offshore wind turbines (FOTW) with Stiesdal’s TetraSpar design. The objective of the project was to enable the design and optimization of next generation FOWT that show promise to make FOWT cost-competitive with other energy technologies by upgrading, verifying, and validating improvements to OpenFAST. This objective was achieved by (1) upgrading OpenFAST to compute floating substructure flexibility and member-level loads, which is critical to enable the design of floating substructures—especially newer designs that are streamlined, flexible, and cost-effective; (2) verifying the new OpenFAST capabilities through model-to-model comparisons and validating the capabilities through comparisons to empirical data generated with wave-tank testing, using TetraSpar data provided by Stiesdal; and (3) making available the upgraded OpenFAST tool to the wind energy community to enable next-generation floating wind designs.

17 WIND ENERGY↗

Robust PCA-Deep Belief Network Surrogate Model for Distribution System Topology Identification with DERs

With the expansion of distribution networks and increased penetration of distributed energy resources (DERs), it is becoming increasingly important to obtain accurate distribution network topology in real-time. In this paper, a robust principal component analysis coupled deep belief network (PCA-DBN) surrogate model is proposed for distribution system topology identification. It integrates the benefits of robust feature extraction from PCA to deal with data quality issues and filter out noise, and the strength of DBN in capturing the nonlinear relationship between voltage amplitudes and the binary states of switchable connections. This also significantly reduces the DBN training complexity without loss of accuracy. It is shown that the widely used standard deviation of voltage drop and the voltage covariance matrix features yield less accuracy as compared to that of the voltage amplitudes in presence of high penetration of DERs and ZIP loads. Comparison results with other alternatives, such as the random forest (RF), multi-output regression (MOR) and the traditional DBN methods demonstrate that the proposed method can achieve a much higher topology identification accuracy while maintaining robustness to missing data and measurement noise under various penetration levels of DERs.

deep belief network↗