Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “linear response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

A flexible gyro-fluid system of equations

Gyro-fluid equations are velocity space moments of the gyrokinetic equations. Special gyro-Landau-fluid closures have been developed that include the damping due to kinetic resonances by fitting to the collisionless local plasma response functions. This damping allows for accurate linear eigenmodes to be computed with a relatively low number of velocity space moments compared to the number of velocity quadrature points in gyrokinetic codes. However, none of the published gyro-Landau-fluid closure schemes considers the Onsager symmetries of the resulting quasi-linear fluxes as a constraint. Onsager symmetry guarantees that the matrix of diffusivities is positive definite, an important property for the numerical stability of a transport solver. A two-parameter real closure for improving the accuracy of low-resolution gyro-fluid equations, which preserves the Onsager symmetry and allows higher velocity space moments, is presented in this paper. The new linear gyro-fluid system (GFS) is used to extend the TGLF quasi-linear transport model so that it can compute the energy and momentum fluxes due to parallel magnetic fluctuations, completing the transport matrix. The GFS equations do not use a bounce average approximation. The GFS equations are fully electromagnetic with general flux surface magnetic geometry, pitch angle scattering for electron collisions, and subsonic equilibrium toroidal rotation. Using GFS eigenmodes in the quasi-linear TGLF model will be shown to yield a more accurate match to fluxes computed by CGYRO turbulence simulations. In conclusion, prospects for future applications of a quasi-linear theory to new plasma transport regimes and magnetic confinement devices in addition to tokamaks are opened by the flexibility of the GFS eigensolver.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Final Seismic Shake Table Test Plan

The Spent Fuel Waste Disposition (SFWD) program is planning to conduct a full-scale seismic shake table test on the dry storage systems of spent nuclear fuel (SNF) to close the gap related to seismic loads on fuel assemblies in dry storage systems. This test will allow for quantifying the strains and accelerations on surrogate fuel assembly hardware and cladding during earthquakes of different magnitudes and frequency content. Full-scale testing is needed because a dry storage system is a complex and highly nonlinear system making it hard to predict (model) the responses to seismic excitations. The non-linearity arises from the multiple spatial gaps in the system – between fuel rods and the basket, between the basket and dry storage canister, between the dry storage canister and the storage cask (overpack), and ventilation gaps. The non-linearities pose significant limitations on the value of tests with scaled systems.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design and evaluation of a low-cost sensor node for near-background methane measurement

Abstract. We developed a low-cost methane sensing node incorporating two metal oxide (MOx) sensors (Figaro Engineering TGS2611-E00 and TGS2600), humidity and temperature sensing, data storage, and telemetry. We deployed the prototype sensor alongside a reference methane analyzer at two sites: one outdoors and one indoors. We collected data at each site for several months across a range of environmental conditions (particularly temperature and humidity) and methane levels. We explored calibration models to investigate the performance of our system and its suitability for methane background monitoring and enhancement detection, first selecting a linear regression to fit a sensor baseline response and then fitting methane response by the sensor deviation from baseline. We achieved moderate accuracy in a 2 to 10 ppm methane range compared to data from the reference analyzer (RMSE < 0.6 ppm), but we found that the sensor response varied over time, possibly as a result of changes in non-targeted gas concentrations. We suggest that this cross sensitivity may be responsible for mixed results in previous studies. We discuss the implications of our results for the use of these and similar inexpensive MOx sensors for methane monitoring in the 2 to 10 ppm range.

Furuta, Daniel↗

Investigation of empirical damping laws for the space shuttle

An analysis of dynamic test data from vibration testing of a number of aerospace vehicles was made to develop an empirical structural damping law. A systematic attempt was made to fit dissipated energy/cycle to combinations of all dynamic variables. The best-fit laws for bending, torsion, and longitudinal motion are given, with error bounds. A discussion and estimate are made of error sources. Programs are developed for predicting equivalent linear structural damping coefficients and finding the response of nonlinearly damped structures.

Bernstein, E. L.↗

Contrast changes in fluoroscopic imaging systems and statistical variations of these changes

Experimental studies have indicated that: (1) The response of digitized fluoroscopic imaging systems is linear systems is linear with contrast over a rather wide range of absorber and cavity thicknesses. (2) Contrast changes associated with the addition of aluminum, iodine containing contrast agents and air of thicknesses 1mm or less can be detected with a 95% confidence level. (3) The standard deviation associated with such determination using clinically available X-ray generators and video disc recording is less than 1 percent. A large flat screen X-ray image intensifier has been constructed and some preliminary results obtained. Sensitivity achieved makes dose reduction a factor often greater than previously reported for a system using a conventional X-ray image intensifier.

Bailey, N. A.↗

Leak detector

A detector for sensing a leaking of fluid pressures is reported. The detector is characterized by an hermetically sealed housing confining therewithin a first normalized pressure, a connector for coupling the housing in direct communication with a suspected leak established within a substantially sealed body, an electrical circuit having a first or normalized configuration and including a pair of circuit completing electrical contacts and means mounting at least one contact of said pair of contacts on a flexible wall of the housing supporting the contact for movement from a first position along a linear path to a second position in response to an altering of the pressure confined within the housing for thereby altering the configuration of the circuit.

Sawyer, J. T.↗

Extraction from flight data of longitudinal aerodynamic coefficients in maneuvering flight for F-8C aircraft

Flight-test data were used to extract the longitudinal aerodynamic parameters of the F-8C aircraft. The aircraft was trimmed in a steady turn at angles of attack of approximately 9 deg and 13 deg at Mach numbers of 0.7 and 0.8. The parameters extracted resulted in a good match to the flight data and the values obtained were reasonable. The values were further verified by comparing the period and time to damp to half-amplitude, as calculated by using the extracted parameter values, with the period and time to damp to half-amplitude actually measured from the flight data traces. These results show that for the set of data examined, a mathematical model using linear aerodynamics was adequate to describe the response motions at the test angles of attack.

Suit, W. T.↗

Development of a moderately sized finite element program for nonlinear structural analysis

AGGIE 1 is a computer program for predicting the linear and nonlinear, static and dynamic structural response of two- and three-dimensional continuum solids. The program is based on isoparametric finite elements and allows for 2-D plane stress, plane strain, and axisymmetric analyses and general 3-D analyses. Large strain kinematics is based on the total Lagrangian formulation. Materially nonlinear models include several elastic-plastic work-hardening models as well as an incompressible Mooney-Rivlin model. Included in this report is a brief description of the theoretical bases of the program, the material models used, the element library and the overall program organization. Instructions for data input preparation are given in detail. Several sample problems are given along with the required program input and program generated solutions.

Haisler, W. E.↗

Combined strength and aeroelastic wing synthesis via constraint approximation

A numerical optimization program using constraint approximations for preliminary sizing of wing structural design parameters to satisfy simultaneous strength and aeroelastic requirements is described. The effects of wing flexibility on loads and flutter are included. The iterative procedure approximates wing internal load distributions and flutter response in generating design constraints. Though a linear Taylor series approximation to the variation of flutter speed is made, constraints in general are formulated as nonlinear and solved in a minimum weight problem using a feasible directions search. The technique is demonstrated for the determination of the optimal ply orientations and for simultaneous sizing for strength and flutter with simple constraint approximations.

Mullen, J., Jr.↗

Nonlinear laminate analysis for metal matrix fiber composites

A nonlinear laminate analysis is described for predicting the mechanical behavior (stress-strain relationships) of angleplied laminates in which the matrix is strained nonlinearly by both the residual stress and the mechanical load and in which additional nonlinearities are induced due to progressive fiber fractures and ply relative rotations. The nonlinear laminate analysis (NLA) is based on linear composite mechanics and a piece wise linear laminate analysis to handle the nonlinear responses. Results obtained by using this nonlinear analysis on boron fiber/aluminum matrix angleplied laminates agree well with experimental data. The results shown illustrate the in situ ply stress-strain behavior and synergistic strength enhancement.

Chamis, C. C.↗

Nonlinear laminate analysis for metal matrix fiber composites

A nonlinear laminate analysis is described for predicting the mechanical behavior (stress-strain relationships) of angle-ply laminates in which the matrix is strained nonlinearly by both the residual stress and the mechanical load and in which additional nonlinearities are induced due to progressive fiber fractures and ply relative rotations. The nonlinear laminate analysis is based on linear composite mechanics and a piece-wise linear laminate analysis to handle the nonlinear responses. Results obtained by using this nonlinear analysis on boron-fiber/aluminum-matrix angle-ply laminates agree well with experimental data. The results shown illustrate the in situ ply stress-strain behavior and synergistic strength enhancement.

Chamis, C. C.↗

The 20 x 20 high speed microwave switches

Tests were conducted at NASA Lewis Research Center to characterize the proof-of-concept matrix switches built under NASA contract by Ford Aerospace and Aeronautics Corporation at Palo Alto, California, and the General Electric Company at Valley Forge, Pennsylvania. The contract requirements and goals are tabulated along with the results of the NASA tests. Characteristics examined are bandwidth, insertion loss, ripple, switching speed, isolation, standing wave ratio (input and output), deviation from linear phase, noise figure, reconfiguration rates, spurious responses, gain compression, and third order intermodulation distortion. A brief description of the testing method and a statistical analysis of the test results for each of the switches are provided.

Saunders, A.↗

Conceptual design of a hybrid Ge:Ga detector array

For potential applications in space infrared astronomy missions such as the Space Infrared Telescope Facility and the Large Deployable Reflector, integrated arrays of long-wavelength detectors are desired. The results of a feasibility study which developed a design for applying integrated array techniques to a long-wavelength (gallium-doped germanium) material to achieve spectral coverage between 30 and 200 microns are presented. An approach which builds up a two-dimensional array by stacking linear detector modules is presented. The spectral response of the Ge:Ga detectors is extended to 200 microns by application of uniaxial stress to the stack of modules. The detectors are assembled with 1 mm spacing between the elements. Multiplexed readout of each module is accomplished with integration sampling of a metal-oxide-semiconductor (MOS) switch chip. Aspects of the overall design, including the anticipated level of particle effects on the array in the space environment, a transparent electrode design for 200 microns response, estimates of optical crosstalk, and mechanical stress design calculations are included.

Parry, C. M.↗

Model of human visual-motion sensing

A model of how humans sense the velocity of moving images is proposed. The model exploits constraints provided by human psychophysics, notably that motion-sensing elements appear tuned for two-dimensional spatial frequency, and by the frequency spectrum of a moving image, namely, that its support lies in the plane in which the temporal frequency equals the dot product of the spatial frequency and the image velocity. The first stage of the model is a set of spatial-frequency-tuned, direction-selective linear sensors. The temporal frequency of the response of each sensor is shown to encode the component of the image velocity in the sensor direction. At the second stage, these components are resolved in order to measure the velocity of image motion at each of a number of spatial locations and spatial frequencies. The model has been applied to several illustrative examples, including apparent motion, coherent gratings, and natural image sequences. The model agrees qualitatively with human perception.

Watson, A. B.↗

Computational solid mechanics (finite elements and boundary elements) - Present status and future directions

Computational finite-element and boundary-element methods are reviewed, and their application to the mechanics of solids is discussed. Stability conditions for general FEMs are considered in addition to the use of least-order, stable, invariant, or hybrid/mixed isoparametric elements as alternatives to the displacement-based isoparametric elements. The use of symbolic manipulation, adaptive mesh refinement, transient dynamic response, and boundary-element methods for linear elaslticity and finite-strain problems of inelastic materials are also discussed.

Atluri, S. N.↗

M.I.T./Canadian vestibular experiments on the Spacelab-1 mission. VI - Vestibular reactions to lateral acceleration following ten days of weightlessness

The effects of weightlessness on human orientation and balance are investigated. The responses of the Spacelab-1 crew to linear acceleration are measured using a perception of linear motion test, a closed-loop otolith assessment test (CLOAT), a dynamic ocular torsion test, and a lateral eye deviations test. The perception of linear motion tests measures a subject's ability to detect the presence and direction of small changes in linear acceleration; CLOAT assesses a person's ability to use linear acceleration cues to perform a manual control task; and the dynamic ocular torsion test examines the gravitoinertial contribution to dynamic ocular counterrolling. The threshold accelerations, velocity constants, regression coefficients, scalar performance measures, and torsion measurements for the subjects are analyzed and described. It is noted that the data support the tilt-translation reinterpretation hypothesis of Young et al. (1984, 1986).

Arrott, A. P.↗

High output paraffin actuators: Utilization in aerospace mechanisms

High Output Paraffin (HOP) thermal actuators were developed to provide an alternative to conventional aerospace actuators: HOP actuators directly convert temperature changes to useful mechanical work. When fabricated with internal resistance heating elements, they provide an electric linear motor. For applications in which slower response times are acceptable or preferred, HOP actuators have distinct advantages over conventional approaches.

Tibbitts, Scott↗