Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Measuring Tracking Accuracy of CCD Imagers

Tracking accuracy and resolution of charge-coupled device (CCD) imaging arrays measured by instrument originally developed for measuring performance of star-tracking telescope. Operates by projecting one or more artifical star images on surface of CCD array, moving stars in controlled patterns, and comparing star locations computed from CCD outputs with those calculated from step coordinates of micropositioner.

Stanton, R. H.↗

Computed Tomography Imaging Spectrometer (CTIS) with 2D Reflective Grating for Ultraviolet to Long-Wave Infrared Detection Especially Useful for Surveying Transient Events

The optical system of this invention is an unique type of imaging spectrometer, i.e. an instrument that can determine the spectra of all points in a two-dimensional scene. The general type of imaging spectrometer under which this invention falls has been termed a computed-tomography imaging spectrometer (CTIS). CTIS's have the ability to perform spectral imaging of scenes containing rapidly moving objects or evolving features, hereafter referred to as transient scenes. This invention, a reflective CTIS with an unique two-dimensional reflective grating, can operate in any wavelength band from the ultraviolet through long-wave infrared. Although this spectrometer is especially useful for events it is also for investigation of some slow moving phenomena as in the life sciences.

Daniel W Wilson↗

Computed tomography imaging spectrometer (CTIS) with 2D reflective grating for ultraviolet to long-wave infrared detection especially useful for surveying transient events

The optical system of this invention is an unique type of imaging spectrometer, i.e. an instrument that can determine the spectra of all points in a two-dimensional scene. The general type of imaging spectrometer under which this invention falls has been termed a computed-tomography imaging spectrometer (CTIS). CTIS's have the ability to perform spectral imaging of scenes containing rapidly moving objects or evolving features, hereafter referred to as transient scenes. This invention, a reflective CTIS with an unique two-dimensional reflective grating, can operate in any wavelength band from the ultraviolet through long-wave infrared. Although this spectrometer is especially useful for rapidly occurring events it is also useful for investigation of some slow moving phenomena as in the life sciences.

Wilson, Daniel W.↗

Status of the JWST Science Instrument Payload

The James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM) system consists of five sensors (4 science): Mid-Infrared Instrument (MIRI), Near Infrared Imager and Slitless Spectrograph (NIRISS), Fine Guidance Sensor (FGS), Near InfraRed Camera (NIRCam), Near InfraRed Spectrograph (NIRSpec); and nine instrument support systems: Optical metering structure system, Electrical Harness System; Harness Radiator System, ISIM Electronics Compartment, ISIM Remote Services Unit, Cryogenic Thermal Control System, Command and Data Handling System, Flight Software System, Operations Scripts System.

JWST Payload↗

Instrument design for an inertial confinement fusion ion temperature imager

A mix of contaminant mass is a known, performance-limiting factor for laser-driven inertial confinement fusion (ICF). It has also recently been shown that the contaminant mass is not necessarily in thermal equilibrium with the deuterium–tritium plasma. Contaminant mass temperature is one of the dominant uncertainties in contaminant mass estimates. The MixIT diagnostic is a new and potentially transformative diagnostic, capable of spatially resolving ion temperature. The approach combines principles of neutron time-of-flight and neutron imaging diagnostics. The information from the MixIT diagnostic can be used to optimize ICF target and laser drive designs as well as provide key constraints on ICF radiation-hydrodynamic simulations that are critical to contaminant mass estimates. This work details the design and optimization of the major components of the MixIT diagnostic: the neutron aperture, the neutron detector (scintillator), and the recording system.

47 OTHER INSTRUMENTATION↗

Helium Ion Microscopy

Nanotechnology research led to the development of various instruments to be used for imaging or fabrication. The helium ion microscope (HIM) became available in 2006 but quickly gained popularity. Its unique gas field ion source enables high-resolution imaging, nanofabrication, direct write, and the recent combination with a secondary ion mass spectrometer offers chemical imaging with ~15 nm resolution. Particularly attractive are the small interaction volume of He and Ne (the two gases offered), small beam spot size, and a moderate sputtering rate. Additionally, the HIM is an excellent imaging tool for insulating samples in soft, polymeric, and biological materials. It can be expected that helium ion microscopy will continue to have a strong influence on broad range of scientific disciplines, including chemistry, materials science, and biology.This chapter aims at providing an overview of the current status of HIM for imaging, analysis, and nanofabrication. It introduces the reader to key components of the instrument, theoretical background, and latest results in the areas of imaging, material fabrication, and chemical analysis capabilities of helium ion microscopy.

Belianinov, Alex↗

A Wolter imager on the Z machine to diagnose warm x-ray sources

A new Wolter x-ray imager has been developed for the Z machine to study the emission of warm (>15 keV) x-ray sources. A Wolter optic has been adapted from observational astronomy and medical imaging, which uses curved x-ray mirrors to form a 2D image of a source with 5 × 5 × 5 mm 3 field-of-view and measured 60-300-μm resolution on-axis. The mirrors consist of a multilayer that create a narrow bandpass around the Mo Kα lines at 17.5 keV. Here, we provide an overview of the instrument design and measured imaging performance. In addition, we present the first data from the instrument of a Mo wire array z-pinch on the Z machine, demonstrating improvements in spatial resolution and a 350-4100× increase in the signal over previous pinhole imaging techniques.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Large format imaging arrays for the Atacama Cosmology Telescope

We describe progress in the fabrication, characterization, and production of detector arrays for the Atacama Cosmology Telescope (ACT). The completed ACT instrument is specified to image simultaneously at 145, 225, and 265 GHz using three 32x32 filled arrays of superconducting transition edge sensors (TES) read out with time-division-multiplexed SQUID amplifiers. We present details of the pixel design and testing including the optimization of the electrical parameters for multiplexed readout. Using geometric noise suppression and careful tuning of operation temperature and device bias resistance, the excess noise in the TES devices is balanced with detector speed for interfacing with the ACT optics. The design also accounts for practical tolerances such as transition temperature gradients and scatter that occur in the production of multiple wafers to populate fully the kilopixel cameras. We have developed an implanted absorber layer compatible with our silicon-on-insulator process that allows for tunable optical resistance with requisite on-wafer uniformity and wafer-to-wafer reproducibility. Arrays of 32 elements have been tested in the laboratory environment including electrical, optical, and multiplexed performance. Given this pixel design, optical tests and modeling are used to predict the performance of the filled array under anticipated viewing conditions. Integration of the filled array of pixels with a tuned backshort and dielectric plate in front of the array maximize absorption and the focal plane and suppress reflections. A mechanical design for the build of the full structure is completed and we report on progress toward the construction of a prototype array for first light on the ACT.

Chervenak, J. A.↗

Transportable, Low-Dose Active Fast-Neutron Imaging

This document contains a description of the method of transportable, low-dose active fast-neutron imaging as developed by ORNL. The discussion begins with the technique and instrumentation and continues with the image reconstruction and analysis. The analysis discussion includes an example of how a gap smaller than the neutron production spot size and detector size can be detected and characterized depending upon the measurement time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative metrics for assessment of chemical image quality and spatial resolution

Rationale: Currently objective/quantitative descriptions of the quality and spatial resolution of mass spectrometry derived chemical images are not standardized. Development of these standardized metrics is required to objectively describe chemical imaging capabilities of existing and/or new mass spectrometry imaging technologies. Such metrics would allow unbiased judgment of intra-laboratory advancement and/or inter-laboratory comparison for these technologies if used together with standardized surfaces. Methods: We developed two image metrics, viz., chemical image contrast (ChemIC) based on signal-to-noise related statistical measures on chemical image pixels and corrected resolving power factor (cRPF) constructed from statistical analysis of mass-to-charge chronograms across features of interest in an image. These metrics, quantifying chemical image quality and spatial resolution, respectively, were used to evaluate chemical images of a model photoresist patterned surface collected using a laser ablation/liquid vortex capture mass spectrometry imaging system under different instrument operational parameters. Results: The calculated ChemIC and cRPF metrics determined in an unbiased fashion the relative ranking of chemical image quality obtained with the laser ablation/liquid vortex capture mass spectrometry imaging system. These rankings were used to show that both chemical image contrast and spatial resolution deteriorated with increasing surface scan speed, increased lane spacing and decreasing size of surface features. Conclusions: ChemIC and cRPF, respectively, were developed and successfully applied for the objective description of chemical image quality and spatial resolution of chemical images collected from model surfaces using a laser ablation/liquid vortex capture mass spectrometry imaging system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance of multimirror quartzline lamps in a high-pressure, underwater environment

Multimirror Quartzline Lamps are extremely versatile and effective for nonconventional imaging requirements such as high-speed photo and video instrumentation and high-magnification imaging. The lamps' versatility though, is not limited to conventional environments. Many research experiments and projects require a high pressure environment. Continuous photographic data acquisition in a high-pressure vessel requires wall penetrations and creates design problems as well as potential failure sites. Underwater photography adds the extra consideration of a liquid. This report expands upon the basic research presented in, Performance of Multimirror Quartzline Lamps in High-Pressure Environments, (NASA-TM-83793, Ernie Walker and Howard Slater, 1984). The report provides information to professional industrial, scientific, and technical photographers as well as research personnel on the survivability of lighting a multimirror quartzline lamp in a nonconventional high-pressure underwater environment. Test results of lighted ELH 300 W multimirror quartzline lamps under high-pressure conditions are documented and general information on the lamps' intensity (footcandle output), cone of light coverage, approximate color temperature is provided. Continuous lighting considerations in liquids are also discussed.

Slater, Howard A.↗

Analysis of Ground-Based Observations of TLES From Spritacular Project Database

Spritacular is a citizen science project that was launched in October of 2022. It provides a space for anyone to submit their transient luminous event (TLE) images along with observational information, i.e. time, geographic location, direction, camera setup. Along with submissions, one can also help identify different types of TLEs in the images submitted. Since its inception hundreds of images have been submitted to the project database by its users. Not only does the database itself provide a record of observations, but these submissions allow for scientists with access to a wider array of observational platforms to obtain a better understanding of TLE’s without having to chase or hunt for them. Citizen science databases come with pros and cons when dealing with observational science and trying to work across different platforms. Using this database, over one hundred sprites were found to have accurate pointing and adequate temporal resolution to attempt to match both ground based (National Lightning Detection Network [NLDN]) and satellite based (Geostationary Lightning Mapper [GLM]) sensors. A statistical analysis of these TLE properties as well as a discussion about the implications these measurements have on the hunt for TLEs both in current space based observational platforms such as the Atmosphere-Space Interaction Monitor (ASIM), International Space Station Lightning Imaging Sensor (ISS-LIS), and GLM or legacy satellite instruments such as the Lightning Imaging Sensor (LIS) on the Tropical Rainfall Measuring Mission (TRMM) satellite will be presented.

T. Daniel Walker↗

A NVLAP Accredited Process for Transfer of Calibration to High Energy Laser Probes

Experiments conducted at national user facilities, such as the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL), employ state-of-the-art instrumentation including optical and X-ray streak cameras, gated imagers, CCDs, and diodes. These instruments are characterized to ensure the diagnostics perform reliably, and data collected during their use will be traceable to relevant standards. A process accredited by the National Voluntary Laboratory Accreditation Program (NVLAP) was developed for transferring the calibration of pulsed high energy laser probes from a standard calibrated by the National Institute of Standards and Testing (NIST) to additional energy probes for use as general working standards. We will discuss the unique challenges of developing the measurement methodologies associated with this calibration transfer, and the analysis of error propagation as it pertains to the expanded uncertainty of the calibration measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Results of testing short wavelength HgCdTe hybrid focal plane arrays for earth remote sensing applications

The NASA Imaging Spectrometer program has the objective to develop the next generation of earth remote sensing systems. One part of the program is concerned with the production of advanced short-wavelength mercury cadmium telluride (HgCdTe) hybrid focal plane arrays (FPAs). These arrays are needed for several instruments, including the Shuttle Imaging Spectrometer (SIS), which requires a mosaic of six 64 x 64-element arrays with a cutoff wavelength of 2.5 microns. A device description is provided and the test results are considered. The Airborne Imaging Spectrometer (AIS) is discussed, taking into account an instrument description, focal plane requirements, and AIS results.

Blessinger, M. A.↗

Land and Cryosphere Products from Suomi NPP VIIRS: Overview and Status

The Visible Infrared Imaging Radiometer Suite (VIIRS) instrument was launched in October 2011 as part of the Suomi National Polar-Orbiting Partnership (S-NPP). The VIIRS instrument was designed to improve upon the capabilities of the operational Advanced Very High Resolution Radiometer and provide observation continuity with NASA's Earth Observing System's Moderate Resolution Imaging Spectroradiometer (MODIS). Since the VIIRS first-light images were received in November 2011, NASA- and NOAA-funded scientists have been working to evaluate the instrument performance and generate land and cryosphere products to meet the needs of the NOAA operational users and the NASA science community. NOAA's focus has been on refining a suite of operational products known as Environmental Data Records (EDRs), which were developed according to project specifications under the National Polar-Orbiting Environmental Satellite System. The NASA S-NPP Science Team has focused on evaluating the EDRs for science use, developing and testing additional products to meet science data needs, and providing MODIS data product continuity. This paper presents to-date findings of the NASA Science Team's evaluation of the VIIRS land and cryosphere EDRs, specifically Surface Reflectance, Land Surface Temperature, Surface Albedo, Vegetation Indices, Surface Type, Active Fires, Snow Cover, Ice Surface Temperature, and Sea Ice Characterization. The study concludes that, for MODIS data product continuity and earth system science, an enhanced suite of land and cryosphere products and associated data system capabilities are needed beyond the EDRs currently available from the VIIRS.

Land Surface↗

The ITER core imaging x-ray spectrometer: X-ray calorimeter performance

We describe the anticipated performance of an x-ray microcalorimeter instrument on ITER. As part of the core imaging x-ray spectrometer, the instrument will augment the imaging crystal spectrometers by providing a survey of the concentration of heavy ion plasma impurities in the core and possibly ion temperature values from the emission lines of different elemental ions located at various radial positions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Co-registered Topographical, Band Excitation Nanomechanical, and Mass Spectral Imaging Using a Combined Atomic Force Microscopy/Mass Spectrometry Platform

The advancement of a hybrid atomic force microscopy/mass spectrometry imaging platform demonstrating for the first time co-registered topographical, band excitation nanomechanical, and mass spectral imaging of a surface using a single instrument is reported. The mass spectrometry-based chemical imaging component of the system utilized nanothermal analysis probes for pyrolytic surface sampling followed by atmospheric pressure chemical ionization of the gas phase species produced with subsequent mass analysis. We discuss the basic instrumental setup and operation and the multimodal imaging capability and utility are demonstrated using a phase separated polystyrene/poly(2-vinylpyridine) polymer blend thin film. The topography and band excitation images showed that the valley and plateau regions of the thin film surface were comprised primarily of one of the two polymers in the blend with the mass spectral chemical image used to definitively identify the polymers at the different locations. Data point pixel size for the topography (390 nm x 390 nm), band excitation (781 nm x 781 nm), mass spectrometry (690 nm x 500 nm) images was comparable and submicrometer in all three cases, but the data voxel size for each of the three images was dramatically different. The topography image was uniquely a surface measurement, whereas the band excitation image included information from an estimated 10 nm deep into the sample and the mass spectral image from 110-140 nm in depth. Moreover, because of this dramatic sampling depth variance, some differences in the band excitation and mass spectrometry chemical images were observed and were interpreted to indicate the presence of a buried interface in the sample. The spatial resolution of the mass spectral image was estimated to be between 1.5 m 2.6 m, based on the ability to distinguish surface features in that image that were also observed in the other images.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Climate Absolute Radiance and Refractivity Observatory (CLARREO) Pathfinder Intercalibration Data Analysis Strategy

One of the prime science objectives of NASA’s Climate Absolute Radiance and Refractivity Observatory (CLARREO) Pathfinder (CPF) mission is to acquire unprecedentedly accurate Système Internationale (SI)-traceable Earth-view measurements that can be used as reference for intercalibrating the Clouds and the Earth’s Radiant Energy System (CERES) and Visible Infrared Imaging Radiometer Suite (VIIRS) instruments onboard NOAA-20 satellite. The hyperspectral nature of CPF measurements will significantly reduce spectrally induced biases when intercalibrating multiband or broadband satellite instruments with CPF. This advancement eliminates the requirement for spectral band adjustment factors, representing a substantial improvement in sensor intercalibration studies. The CPF intercalibration team is aiming to achieve a maximum intercalibration methodology uncertainty of 0.3 % (k=1). Our studies have revealed that the most significant contribution to the targeted uncertainty budget originates from the combined effects of spatial and temporal matching errors. Spatial matching error arises from discrepancies in CPF and target instrument pixel resolution and geolocation uncertainty, while temporal matching error is caused by changes in scene radiances over time, occurring between when the target and reference instruments observe the same scenes. To estimate the maximum expected uncertainty contribution from these sources, spatial and temporal matching noise analyses were conducted using algorithmically filtered Landsat 9 Operational Land Imager (OLI) and Geostationary Operational Environmental Satellite (GOES)-16 ABI CONUS scan data as proxies for CPF and target instruments. In the upcoming conference presentation, we will elaborate on the methodology employed in these experiments, provide details of the data filtering algorithms, and present results of the spatial and temporal matching uncertainty analyses.

Intercalibration↗