Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image alignment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Electrodynamic parameters in the nighttime sector during auroral substorms

The characteristics of the large-scale electrodynamic parameters, field-aligned currents (FACs), electric fields, and electron precipitation, which are associated with auroral substorm events in the nighttime sector, have been obtained through a unique analysis which places the ionospheric measurements of these parameters into the context of a generic substorm determined from global auroral images. A generic bulge-type auroral emission region has been deduced from auroral images taken by the Dynamics Explorer 1 (DE 1) satellite during a number of isolated substorms, and the form has been divided into six sectors, based on the peculiar emission characteristics in each sector: west of bulge, surge horn, surge, middle surge, eastern bulge, and east of bulge. By comparing the location of passes of the Dynamics Explorer 2 (DE 2) satellite to the simultaneously obtained auroral images, each pass is placed onto the generic aurora. The organization of DE 2 data in this way has systematically clarified peculiar characteristics in the electrodynamic parameters. An upward net current mainly appears in the surge, with little net current in the surge horn and the west of bulge. The downward net current is distributed over wide longitudinal regions from the eastern bulge to the east of bulge. Near the poleward boundary of the expanding auroral bulge, a pair of oppositely directed FAC sheets is observed, with the downward FAC on the poleward side. This downward FAC and most of the upward FAC in the surge and the middle surge are assoc iated with narrow, intense antisunwqard convection, corresponding to an equatorward directed spikelike electric field. This pair of currents decreases in amplitude and latitudinal width toward dusk in the surge and the west of bulge, and the region 1 and 2 FACs become embedded in the sunward convection region. The upward FAC region associated with the spikelike field on the poleward edge of the bulge coincides well with intense electron precipitation and aurora appearing in this western and poleward protion of the bulge. The convection reversal is sharp in the west of bulge and surge horn sectors, and near the high-latitude boundary of the upward region 1, with a near stagnation region often extending over a large interval of latitude. In the eastern bulge and east of bulge sectors, the region 1 and 2 FACs are located in the sunward convection region, while a spikelike electric field occasionally appears poleward of the aurora but usually not associated with a pair of FAC sheets. In the eastern bulge, magnetic field data show complicated FAC distributions which correspond to current segments and filamentary currents.

Fujii, R.↗

The Hitomi X-Ray Observatory, Part 2

When it was launched on 17 February 2016, the Hitomi X-ray Observatory carried four kinds of new-generation x-ray instruments—the Soft X-ray Spectrometer (SXS), the Soft X-ray Imager (SXI), the Hard X-ray Imager (HXI), and the Soft Gamma-ray Detector (SGD). All four instruments were turned on and were in the process of activation at the time of loss of contact on 26 March 2016. In the time it was operational, Hitomi was able to provide researchers with a trove of ground-breaking scientific results. Initial results demonstrated that the instruments were meeting or exceeding requirements and that Hitomi was on its way to pioneering a new era of broad-band and high-resolution x-ray spectroscopy. The results published here summarize the in-flight instrument performance, calibration, and data processing accomplishments of the observatory. Of the papers accepted for publication in this special section, 17 were presented in Part 1 in the January-March 2018 issue of JATIS (Journal of Astronomical Telescopes, Instruments, and Systems). Ten more papers are presented here as Part 2 in the April-June 2018 issue. These papers cover the detailed in-flight performance of the four state-of the-art instruments on-board the Hitomi X-Ray Observatory. These instruments were extremely diverse in their design and principles of operation, ranging from low temperature x-ray calorimeters for high-resolution spectroscopy, CCDs (Charge-Coupled Devices) for wide field imaging, high fill-factor grazing incidence x-ray optics, including multilayer x-ray optics and silicon strip and CdTe strip detectors for high-energy imaging, and a Si/CdTe Compton cameras for extending the bandpass out to 600 kiloelectronvolts. All of these instruments operated as expected and for sufficient time to validate their operating principles and carry out first light scientific investigations, published elsewhere. Collectively, these instruments, all co-aligned and operated simultaneously, provided a tool for astronomers with unprecedented resolution and broadband sensitivity for investigating high-energy processes throughout the universe. These papers serve as part of the Hitomi legacy and will guide the next generation of instruments planned for future missions.

Kelley, Richard L.↗

Ultrasonic through-wall sensors

Aspects of ultrasonic through-wall data communication are described. In some aspects, a sensor device is located in an isolated environment behind a wall. A modulator generates a modulated sensor signal based on the binary sensor signal and a carrier signal. A coaxially aligned pair of electroacoustic transducers that transmits the modulated sensor signal through the wall of the isolated environment. A demodulator demodulates the modulated sensor signal to generate a demodulated binary sensor signal. A sensor data recovery component converts the demodulated binary sensor signal into an image or another sensor parameter.

Zhang, Haifeng↗

WE-AB-207A-10: Transmission Characteristics of a Two Dimensional Antiscatter Grid Prototype for CBCT

Purpose: Scattered radiation remains to be a major contributor to image quality degradation in CBCT. To address the scatter problem, a focused, 2D antiscatter grid (2DASG) prototype was designed, and fabricated using additive manufacturing processes. Its scatter and primary transmission properties were characterized using a linac mounted CBCT system. Methods: The prototype 2DASG was composed of rectangular grid holes separated by tungsten septa, and has a grid pitch of 2.91 mm, grid ratio of 8, and a septal thickness of 0.1 mm. Each grid hole was aligned or focused towards the x-ray source in half-fan (i.e. offset detector) geometry of the Varian TrueBeam CBCT system. Scatter and primary transmission experiments were performed by using acrylic blocks and the beam-stop method. Transmission properties of a radiographic ASG (1DASG) (grid ratio of 10) was also performed by using the identical setup. Results: At 30 cm phantom thickness, scatter to primary ratio (SPR) was 4.51 without any ASG device. SPR was reduced to 1.28 with 1DASG, and it was further reduced to 0.28 with 2DASG. Scatter transmission fraction (Ts) of 1DASG was 21%, and Ts was reduced to 5.8% with 2DASG. The average primary transmission fraction (Tp) of 1DASG was 70.6%, whereas Tp increased to 85.1% with 2DASG. Variation of Tp across 40 cm length (the long axis of flat panel detector) was 2.6%. Conclusion: When compared to conventional ASGs, the focused 2DASG can vastly improve scatter suppression and primary transmission performance. Due to precise alignment of 2DASG’s grid holes with respect to beam divergence, high degree of primary transmission through the 2DASG was maintained across the full length of the prototype. We strongly believe that robust scatter rejection and primary transmission characteristics of our 2DASG can translate into both improved quantitative accuracy and soft tissue resolution in linac mounted CBCT systems.

60 APPLIED LIFE SCIENCES↗

Defect Characterization Through Automated Laser Track Trace Identification in SLM Processes Using Laser Profilometer Data

This paper presents recent developments in statistical image processing to demonstrate feasibility of layer-by-layer nondestructive inspection for selective laser melting (SLM) of metallic parts. A matrix of 10 mm × 10 mm stainless 316 squares was deposited with the first row consisting of just the sintered surface, Row 2 a single layer, Row 3 with 2 layers and so on. These layers were scanned to emulate the layer-by-layer collection of top surface geometry using a laser sensor. The resultant data were utilized to generate ISO 25718 roughness parameters and subsequently to perform track identification. This calculation consisted of two salient steps: (1) computing the gradients of surface roughness, which vanish at the peaks and pits, and (2) extracting the scanning direction by taking Hough transform of the geometry. This algorithm was repeated for all layers, and the alignment of the roughness with the rotating scan was observed to be persistent for all layers. Correlation between surface properties obtained along various scan directions and defect probability is explored.

36 MATERIALS SCIENCE↗

Hybrid chemical characterization of latent images in EUV resist with 12 nm half-pitch features

With the advancement of high numerical aperture extreme ultraviolet (EUV) lithography, the new platform will enable chipmakers to achieve critical dimensions of 8 nm. However, resist materials face significant challenges in delivering increased sensitivity while managing rising stochastic variations. We aim to develop comprehensive techniques to characterize the chemical profile of latent images, stored in EUV resists after exposure and postexposure baking, which is essential for understanding the origin of stochastic effects. Infrared photo-induced force microscopy (IR PiFM) is a bimodal atomic force microscopy technique combined with an infrared light source, allowing for simultaneous sub-5 nm topographic and chemical characterization within a localized environment. Critical-dimension resonant soft X-ray scatterometry (CD-RSoXS) provides statistical data that reveal structural and chemical information for comparative analysis. For the first time, IR PiFM has been used to chemically map the latent images of EUV resists (after exposure and postexposure baking) at a record high resolution of 12 nm half-pitch, enabling nondestructive analysis of patterns prior to development. Furthermore, CD-RSoXS offers direct experimental observation and comparison of exposed, postexposure baked, and developed patterns, which align with the IR PiFM results. We demonstrate that the IR PiFM technique offers valuable insights into both high spatial resolution and local chemical information simultaneously. In addition, CD-RSoXS provides statistical results that support our main findings. This hybrid metrology approach leverages a multifaceted dataset by combining the most reliable information from each source, which is essential for a comprehensive understanding of the stochastic effects in EUV lithography processes.

O’Reilly, Padraic↗

Time delay and integration array (TDI) using charge transfer device technology. Phase 2, volume 1: Technical

The 20x9 TDI array was developed to meet the LANDSAT Thematic Mapper Requirements. This array is based upon a self-aligned, transparent gate, buried channel process. The process features: (1) buried channel, four phase, overlapping gate CCD's for high transfer efficiency without fat zero; (2) self-aligned transistors to minimize clock feedthrough and parasitic capacitance; and (3) transparent tin oxide electrode for high quantum efficiency with front surface irradiation. The requirements placed on the array and the performance achieved are summarized. This data is the result of flat field measurements only, no imaging or dynamic target measurements were made during this program. Measurements were performed with two different test stands. The bench test equipment fabricated for this program operated at the 8 micro sec line time and employed simple sampling of the gated MOSFET output video signal. The second stand employed Correlated Doubled Sampling (CDS) and operated at 79.2 micro sec line time.

Source record↗

Extraordinary line-emitting knots in the Crab Nebula

Extraordinary, semistellar, line-emitting knots are apparent in images of the Crab Nebula which were obtained with the Goddard Fabry-Perot imager at the Michigan-Dartmouth-MIT Observatory. The knots are most prominent for (O III) lambda 5007 emission through a 5.3 A (Full Width at Half Maximum (FWHM)) bandpass centered at 5015.3 A, with representative fluxes of roughly 10(exp -14) ergs/sq cm. They are aligned in arcs, seven to the north and four to the south, from the pulsar. The northern group appears to be in a bounded corridor through the filamentary structure. Measurements over a 2 year baseline yield proper motions of order 0.1 sec/yr, corresponding to transverse velocities of order 900 km/s for a distance of 1830 pc. The knots are characterized by remarkably strong (Ar III) emission, possibly indicating high argon abundances, high gas temperatures, or anomalous physical processes.

Macalpine, Gordon M.↗

NASA Tech Briefs, September 2008

Topics covered include: Nanotip Carpets as Antireflection Surfaces; Nano-Engineered Catalysts for Direct Methanol Fuel Cells; Capillography of Mats of Nanofibers; Directed Growth of Carbon Nanotubes Across Gaps; High-Voltage, Asymmetric-Waveform Generator; Magic-T Junction Using Microstrip/Slotline Transitions; On-Wafer Measurement of a Silicon-Based CMOS VCO at 324 GHz; Group-III Nitride Field Emitters; HEMT Amplifiers and Equipment for their On-Wafer Testing; Thermal Spray Formation of Polymer Coatings; Improved Gas Filling and Sealing of an HC-PCF; Making More-Complex Molecules Using Superthermal Atom/Molecule Collisions; Nematic Cells for Digital Light Deflection; Improved Silica Aerogel Composite Materials; Microgravity, Mesh-Crawling Legged Robots; Advanced Active-Magnetic-Bearing Thrust- Measurement System; Thermally Actuated Hydraulic Pumps; A New, Highly Improved Two-Cycle Engine; Flexible Structural-Health-Monitoring Sheets; Alignment Pins for Assembling and Disassembling Structures; Purifying Nucleic Acids from Samples of Extremely Low Biomass; Adjustable-Viewing-Angle Endoscopic Tool for Skull Base and Brain Surgery; UV-Resistant Non-Spore-Forming Bacteria From Spacecraft-Assembly Facilities; Hard-X-Ray/Soft-Gamma-Ray Imaging Sensor Assembly for Astronomy; Simplified Modeling of Oxidation of Hydrocarbons; Near-Field Spectroscopy with Nanoparticles Deposited by AFM; Light Collimator and Monitor for a Spectroradiometer; Hyperspectral Fluorescence and Reflectance Imaging Instrument; Improving the Optical Quality Factor of the WGM Resonator; Ultra-Stable Beacon Source for Laboratory Testing of Optical Tracking; Transmissive Diffractive Optical Element Solar Concentrators; Delaying Trains of Short Light Pulses in WGM Resonators; Toward Better Modeling of Supercritical Turbulent Mixing; JPEG 2000 Encoding with Perceptual Distortion Control; Intelligent Integrated Health Management for a System of Systems; Delay Banking for Managing Air Traffic; and Spline-Based Smoothing of Airfoil Curvatures.

Source record↗

Thomas Leps Internship Abstract

An optical navigation system is being flown as the backup system to the primary Deep Space Network telemetry for navigation and guidance purposes on Orion. This is required to ensure Orion can recover from a loss of communication, which would simultaneously cause a loss of DSN telemetry. Images taken of the Moon and Earth are used to give range and position information to the navigation computer for trajectory calculations and maneuver execution. To get telemetry data from these images, the size and location of the moon need to be calculated with high accuracy and precision. The reentry envelope for the Orion EM-1 mission requires the centroid and radius of the moon images to be determined within 1/3 of a pixel 3 sigma. In order to ensure this accuracy and precision can be attained, I was tasked with building precise dot grid images for camera calibration as well as building a hardware in the loop test stand for flight software and hardware proofing. To calibrate the Op-Nav camera a dot grid is imaged with the camera, the error between the image dot location and the actual dot location can be used to build a distortion map of the camera and lens system so that images can be fixed to display truth locations. To build the dot grid images I used the Electro Optics Lab optical bench Bright Object Simulator System, and gimbal. The gimbal was slewed to a series of elevations and azimuths. An image of the collimated single point light source was then taken at each position. After a series of 99 images were taken at different locations the single light spots were extracted from each image and added to a composite image containing all 99 points. During the development of these grids it was noticed that an intermittent error in the artificial "star" locations occurred. Prior to the summer this error was attributed to the gimbal having glitches in it's pointing direction and was going to be replaced, however after further examining the issue I determined it to be a software issue. I have since narrowed the likely source of the error down to a Software Development Kit released by the camera supplier PixeLink. I have since developed a workaround in order to build star grids for calibration until the software bug can be isolated and fixed. I was also tasked with building a Hardware in the Loop test stand in order to test the full Op-Nav system. A 4k screen displays simulated Lunar and Terrestrial images from a possible Orion trajectory. These images are then projected through a collimator and then captured with an Op-Nav camera controlled by an Intel NUC computer running flight software. The flight software then analyzes the images to determine attitude and position, this data is then reconstructed into a trajectory and matched to the simulated trajectory in order to determine the accuracy of the attitude and position estimates. In order for the system to work it needs to be precisely and accurately aligned. I developed an alignment procedure that allows the screen, collimator and camera to be squared, centered and collinear with each other within a micron spatially and 5 arcseconds in rotation. I also designed a rigid mount for the screen that was machined on site in Building 10 by another intern. While I was working in the EOL we received a $500k Orion startracker for alignment procedure testing. Due to my prior experience in electronics development, as an ancillary duty, I was tasked with building the cables required to operate and power the startracker. If any errors are made building these cables the startracker would be destroyed, I was honored that the director of the lab entrusted such a critical component with me. This internship has cemented my view on public space exploration. I always preferred public sector to privatization because, as a scientist, the most interesting aspects of space for me are not necessarily the most profitable. I was concerned that the public sector was faltering however, and that in order to improve human space exploration I would be forced into private sector. I now know that, at least at JSC, human spaceflight is still progressing, and exciting work is still being done. I am now actively seeking employment at JSC after I complete my Ph.D and have met with my branch chiefs and mentor to discuss transitioning to a grad Co-op position.

Leps, Thomas↗

Camera modeling, centroiding performance, and geometric camera calibration on ASTERIA

The Arcsecond Space Telescope Enabling Research in Astrophysics (ASTERIA) is a 10-kg, 6U CubeSat in low-Earth orbit that was able to achieve subarcsecond pointing stability and repeatability. To date, this is the best pointing on a spacecraft of its size. This paper will analyze various aspects of the performance of its key piece of hardware—the payload. First,a model of the optics and imager, which is used to simulate stellar images, will be presented. The imager parameters used in this model were derived from simple ground measurements. Next, a centroiding algorithm is provided and used on the simulated images to predict centroiding performance. These results will be shown to match on-orbit telemetry of centroiding performance, validating the modeling approach. This paper will then describe an approach for and results of a geometric camera calibration algorithm to estimate the focal length,distortion,and alignment parameters. The modeling, analyses, and results presented in this paper provide key information that can be used in a time domain pointing simulation or a frequency-domain pointing error analysis.

Smith, Matthew W.↗

THE KINEMATICS OF HH 34 FROM HST IMAGES WITH A NINE-YEAR TIME BASELINE

We study archival HST [S II] 6716+30 and H{alpha} images of the HH 34 outflow, taken in 1998.71 and in 2007.83. The {approx}9 yr time baseline and the high angular resolution of these observations allow us to carry out a detailed proper-motion study. We determine the proper motions of the substructure of the HH 34S bow shock (from the [S II] and H{alpha} frames) and of the aligned knots within {approx}30'' from the outflow source (only from the [S II] frames). We find that the present-day motions of the knots along the HH 34 jet are approximately ballistic, and that these motions directly imply the formation of a major mass concentration in {approx}900 yr, at a position similar to the one of the present-day HH 34S bow shock. In other words, we find that the knots along the HH 34 jet will merge to form a more massive structure, possibly resembling HH 34S.

79 ASTRONOMY AND ASTROPHYSICS↗

MO-PIS-Exhibit Hall-01: Imaging: CT Dose Optimization Technologies I

Partners in Solutions is an exciting new program in which AAPM partners with our vendors to present practical “hands-on” information about the equipment and software systems that we use in our clinics. The imaging topic this year is CT scanner dose optimization capabilities. Note that the sessions are being held in a special purpose room built on the Exhibit Hall Floor, to encourage further interaction with the vendors. Dose Optimization Capabilities of GE Computed Tomography Scanners Presentation Time: 11:15 – 11:45 AM GE Healthcare is dedicated to the delivery of high quality clinical images through the development of technologies, which optimize the application of ionizing radiation. In computed tomography, dose management solutions fall into four categories: employs projection data and statistical modeling to decrease noise in the reconstructed image - creating an opportunity for mA reduction in the acquisition of diagnostic images. Veo represents true Model Based Iterative Reconstruction (MBiR). Using high-level algorithms in tandem with advanced computing power, Veo enables lower pixel noise standard deviation and improved spatial resolution within a single image. Advanced Adaptive Image Filters allow for maintenance of spatial resolution while reducing image noise. Examples of adaptive image space filters include Neuro 3-D filters and Cardiac Noise Reduction Filters. AutomA adjusts mA along the z-axis and is the CT equivalent of auto exposure control in conventional x-ray systems. Dynamic Z-axis Tracking offers an additional opportunity for dose reduction in helical acquisitions while SmartTrack Z-axis Tracking serves to ensure beam, collimator and detector alignment during tube rotation. SmartmA provides angular mA modulation. ECG Helical Modulation reduces mA during the systolic phase of the heart cycle. SmartBeam optimization uses bowtie beam-shaping hardware and software to filter off-axis x-rays - minimizing dose and reducing x-ray scatter. The DICOM Radiation Dose Structured Report (RDSR) generates a dose report at the conclusion of every examination. Dose Check preemptively notifies CT operators when scan parameters exceed user-defined dose thresholds. DoseWatch is an information technology application providing vendor-agnostic dose tracking and analysis for CT (and all other diagnostic x-ray modalities) SnapShot Pulse improves coronary CTA dose management. VolumeShuttle uses two acquisitions to increase coverage, decrease dose, and conserve on contrast administration. Color-Coding for Kids applies the Broselow-Luten Pediatric System to facilitate pediatric emergency care and reduce medical errors. FeatherLight achieves dose optimization through pediatric procedure-based protocols. Adventure Series scanners provide a child-friendly imaging environment promoting patient cooperation with resultant reduction in retakes and patient motion. Philips CT Dose Optimization Tools and Advanced Reconstruction Presentation Time: 11:45 ‘ 12:15 PM The first part of the talk will cover “Dose Reduction and Dose Optimization Technologies” present in Philips CT Scanners. The main Technologies to be presented include: DoseRight and tube current modulation (DoseRight, Z-DOM, 3D-DOM, DoseRight Cardiac) Special acquisition modes Beam filtration and beam shapers Eclipse collimator and ClearRay collimator NanoPanel detector DoseRight will cover automatic tube current selection that automatically adjusts the dose for the individual patient. The presentation will explore the modulation techniques currently employed in Philips CT scanners and will include the algorithmic concepts as well as illustrative examples. Modulation and current selection technologies to be covered include the Automatic Current Selection component of DoseRight, ZDOM longitudinal dose modulation, 3D-DOM (combination of longitudinal and rotational dose modulation), Cardiac Dose right (an ECG based dose modulation scheme), and the DoseRight Index (DRI) IQ index. The special acquisition modes covers acquisition techniques such as prospective gating that is designed to reduce exposure to the patient through the Cardiac Step and Shoot scan mode. This mode can substitute the much higher dose retrospective scan modes for certain types of cardiac imaging. The beam filtration and beam shaper portion will discuss the variety of filtration and beam shaping configurations available on Philips scanners. This topic includes the x-ray beam characteristics, tube filtration as well as dose compensator characteristics. The Eclipse collimator, ClearRay collimator and the NanoPanel detector portion will discuss additional technologies specific to wide coverage CT that address some of the unique challenges encountered and techniques employed to optimize image quality and optimize dose utilization. The Eclipse collimator reduces extraneous exposure by actively blocking the radiation tails at either end of helical scans that do not contribute to the image generation. The ClearRay collimator and the NanoPanel detector optimize the quality of the signal that reaches the detectors by addressing the increased scattered radiation present in wide coverage and the NanoPanel detector adds superior electronic noise characteristics valuable when imaging at a low dose level. The second part of the talk will present “Advanced Reconstruction Technologies” currently available on Philips CT Scanners. The talk will cover filtered back projection (FBP), iDose4 and Iterative Model Reconstruction (IMR). Each reconstruction method will include a discussion of the algorithm as well as similarities and differences between the algorithms. Examples illustrating the merits of each algorithm will be presented, and techniques and metrics to characterize the performance of each type of algorithm will be presented. The Filtered Back projection portion will discuss and provide a brief summary of relevant standard image reconstruction techniques in common use, and discuss the common tradeoffs when using the FBP algorithm. The iDose4 portion will present the algorithms used for iDose4 as well the different levels. The meaning of different levels of iDose4 available will be presented and quantified. Guidelines for selection iDose4 parameters based on the imaging need will be explained. The different image quality goals available with iDose4 and specifically how iDose4 enables noise reduction, spatial resolution improvement or both will be explained. The approaches to leveraging the benefits of iDose4 such as improved spatial resolution, decreased noise, and artifact prevention will be described and quantified; and measurements and metrics behind the improvements will be presented. The image quality benefits in specific imaging situations as well as how to best combine the technology with other dose reduction strategies to ensure the best image quality at a given dose level will be presented. Insight into the IMR algorithm as well as contrast to the iDose4 techniques and performance characteristics will be discussed. Metrics and techniques for characterizing this class of algorithm and IQ performance will be presented. The image quality benefits and the dose reduction capabilities of IMR will be explored. Illustrative examples of the noise reduction, spatial resolution improvement, and low contrast detectability improvements of the reconstruction method will be presented: clinical cases and phantom measurements demonstrating the benefits of IMR in the areas of low dose imaging, spatial resolution and low contrast resolution are discussed and the technical details behind the measurements will be presented compared to both iDose4 and traditional filtered back projection (FBP)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical birefringence imaging of x-ray excited lithium tantalate

X-ray absorption in lithium tantalate induces large, long-lived (~10 -5 s) optical birefringence, visualized via scanning optical polarimetry, likely arising from electrooptic coupling to x-ray induced electric fields. Similar birefringence measured from glass, sapphire, and quartz was two orders of magnitude weaker. This suggests that x-ray excited charges preferentially create ordered, aligned dipoles within the noncentrosymmetric unit cell of ferroelectric LiTaO 3 , enhancing the electric field compared to more isotropic charge distributions in the other materials. In conclusion, time-resolved measurements show a prompt response on a picosecond time scale, which along with the long decay time suggest novel approaches to optical detection of x-rays using ferroelectric materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Overview of the KSTAR experiments and future plan

The Korea Superconducting Tokamak Advanced Research (KSTAR) device has recently entered a new phase of operation following the installation of a tungsten mono-block divertor, providing a unique platform to investigate high-performance, long-pulse plasma scenarios for future reactors. The 2023–2024 experimental campaigns demonstrated significant progress in commissioning the tungsten divertor, developing plasma operation scenarios, and achieving real-time control. Comparative studies revealed increased core radiation losses and associated performance degradation relative to the carbon divertor environment. Alleviation strategies, such as optimized neutral beam injection timing, boron powder seeding, and impurity control through gas puffing, were shown to reduce tungsten accumulation and extend high-performance phases, including record H-mode operation exceeding 100 s. International collaboration enabled the first demonstration of high poloidal beta scenarios with an internal transport barrier on KSTAR. Advances in control included upgraded real-time resonant magnetic perturbation schemes and disruption forecasting. Furthermore, divertor detachment control using a new surrogate-model-based approach with real-time radiation imaging demonstrated active impurity and heat flux management. Supported by enhanced heating, current drive, and diagnostic systems, these achievements offer valuable insights into tungsten impurity behavior, transport physics, and control strategies for future reactors including ITER. Planned upgrades toward a full-tungsten wall and ITER-aligned real-time plasma control will further establish KSTAR as a leading experimental platform for developing operational scenarios required to achieve steady-state, burning plasma conditions.

KSTAR↗

Assembly and testing of a large zoom lens for proton radiography

A zoom lens has been designed for proton radiography applications. Radiographic images are recorded at the end of an accelerator, where protons exit an aluminum vacuum window, producing a shadowgraph image onto an LYSO (lutetium yttrium orthosilicate) scintillator. Emission from this 5-inch-square scintillator reflects off a pellicle and is then collected by a zoom lens located 24 inches away. Proton radiography can make high-speed, multi-frame radiographs or radiographic movies. This zoom lens provides 2X magnification for viewing different object sizes. The zoom lens incorporates eleven lenses, including a moving doublet that changes the magnification. Refocus of the camera is required when zooming. Only one moving doublet lens is required to change magnification. The stop was anchored to the moving doublet, and its diameter is unchanged throughout magnification changes. The entire lens system is housed in a cylindrical tube. This lens will be used with a 10-frame camera with a 44 × 44 mm square image format and 1100 × 1100 pixel resolution. Suppressing stray light is very important in this lens system. Radial compensation is controlled by two locking micrometers on element 9, which relaxes the mechanical tolerancing. A helical cam barrel using a linear rail controls the movement of the doublet. Alignment of the mechanical gears will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗