Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “future accelerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

The Continuous Electron Beam Accelerator Facility at 12 GeV

This review paper describes the energy-upgraded Continuous Electron Beam Accelerator Facility (CEBAF) accelerator. This superconducting linac has achieved 12 GeV beam energy by adding 11 new high-performance cryomodules containing 88 superconducting cavities that have operated cw at an average accelerating gradient of 20 MV / m . After reviewing the attributes and performance of the previous 6 GeV CEBAF accelerator, we discuss the upgraded CEBAF accelerator system in detail with particular attention paid to the new beam acceleration systems. In addition to doubling the acceleration in each linac, the upgrade included improving the beam recirculation magnets, adding more helium cooling capacity to allow the newly installed modules to run cold, adding a new experimental hall, and improving numerous other accelerator components. We review several of the techniques deployed to operate and analyze the accelerator performance and document system operating experience and performance. In the final portion of the document, we present much of the current planning regarding projects to improve accelerator performance and enhance operating margins, and our plans for ensuring CEBAF operates reliably into the future. For the benefit of potential users of CEBAF, the performance and quality measures for the beam delivered to each of the experimental halls are summarized in the Appendix. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Status of the LANSCE refurbishment project

The Los Alamos Neutron Science Center (LANSCE) accelerator is an 800-MeV proton linac that drives user facilities for isotope production, proton radiography, ultra-cold neutrons, weapons neutron research and various sciences using neutron scattering. The LANSCE Refurbishment Project (LANSCE-R) is an ambitious project to refurbish key elements of the LANSCE accelerator that are becoming obsolete or nearing end-of-life. The preliminary design phase for the project is funded and underway. The 6 year, $150M (US) project will enable future decades of reliable, high-performance operation. It will replace a substantial fraction of the radio-frequency power systems (gridded tubes and klystrons) with modern systems, completely refurbish the original accelerator control and timing systems, replace obsolete diagnostic devices, and modernize other ancillary systems. An overview of the LANSCE-R project will be presented. The project requirements will be discussed, the preliminary technical solutions presented, and the plan for successful project execution while meeting annual customer expectations for beam delivery will be reviewed.

43 PARTICLE ACCELERATORS↗

Multidimensional world, inflation, and modern acceleration

Starting from pure multidimensional gravity with curvature-nonlinear terms but no matter fields in the initial action, we obtain a cosmological model with two effective scalar fields related to the size of two extra factor spaces. The model includes both an early inflationary stage and that of modern accelerated expansion and satisfies the observational data. There are no small parameters; the effective inflaton mass depends on the initial conditions which explain its small value as compared to the Planck mass. At the modern stage, the size of extra dimensions slowly increases, therefore this model predicts drastic changes in the physical laws of our Universe in the remote future.

79 ASTRONOMY AND ASTROPHYSICS↗

The status of the SNS external antenna ion source and spare RFQ test facility

The Oak Ridge National Laboratory operates the Spallation Neutron Source, consisting of a H{sup −} ion source, a 1 GeV linac and an accumulator ring. The accumulated <1 μs-long, ∼35 A beam pulses are extracted from the ring at 60 Hz and directed onto a liquid Hg target. Spalled neutrons are directed to ∼20 world class instruments. Currently, the facility operates routinely with ∼1.2 MW of average beam power, which soon will be raised to 1.4 MW. A future upgrade with a second target station calls for raising the power to 2.8 MW. This paper describes the status of two accelerator components expected to play important roles in achieving these goals: a recently acquired RFQ accelerator and the external antenna ion source. Currently, the RFQ is being conditioned in a newly constructed 2.5 MeV Integrated Test Facility (ITF) and the external antenna source is also being tested on a separate test stand. This paper presents the results of experiments and the testing of these systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Laser-Electron-Interaction Region for Compact High Repetition-Rate Mono-Energetic Laser Based Gamma Sources

Inverse-Compton scattering (ICS) is a well-established technique capable of producing monochromatic radiation over a large range of the electromagnetic spectrum. Most recently, ICS has attracted attention, owing to its compactness and possible coupling with novel acceleration methods to yield compact X- and 𝛄-ray sources. Under this award, we carried out a systematic optimization of the ICS and demonstrate via numerical simulation that combining ICS with a conventional superconducting linac could produce Watt-level average-power 𝛄 rays with high spectral brightness. The study is performed with idealized laser and electron-beam distributions and confirmed with the realistic distributions simulated from start-to-end numerical modeling of the electron accelerator. The studies led to the design and engineering design of an ICS interaction point for the FAST facility along with some beam measurement. Due to the cancellation of the program in Year 3 long with delay in the commissioning of the FAST facility, we were not able to demonstrate the generation of 𝛄 rays, we, however, procured some of the hardware, installed some of the required infrastructures and plan to eventually generate 𝛄 ray pending future interest on the topics and availability of funding.

43 PARTICLE ACCELERATORS↗

Assessment and Improvement Proposals for High-Pressure Rinsing Processes during Cleanroom Preparation of Superconducting Radio-Frequency Cavities for Particle Accelerators

The goal of this internship is to develop a fluid dynamics characterization of the high-pressure flow used for cleaning the internal surface of the SRF cavities. Initially, the High Pressure Rinsing (HPR) process is introduced, focusing on the problems of the SRF cavities and how this method can be used to increase their acceleration efficiency and performance. The characterization of the problem is then presented, including an introduction to the multiphase flow modeling and the analysis of the Fermilab facility for the HPR. To accomplish the goal, a preliminary estimation of the variables was performed using MATLAB. Then, multiple 2D simulations were developed with Ansys Fluent, and the influence of the main parameter was investigated. The simulation results are then presented and analysed, with a focus on the possible future developments of the HPR process fluid dynamic characterization.

43 PARTICLE ACCELERATORS↗

Tunable Laser Plasma Accelerator based on Longitudinal Density Tailoring

Laser plasma accelerators have produced high-quality electron beams with GeV energies from cm-scale devices and are being investigated as hyperspectral fs light sources producing THz to {gamma}-ray radiation and as drivers for future high-energy colliders. These applications require a high degree of stability, beam quality and tunability. Here we report on a technique to inject electrons into the accelerating field of a laser-driven plasma wave and coupling of this injector to a lower-density, separately tunable plasma for further acceleration. The technique relies on a single laser pulse powering a plasma structure with a tailored longitudinal density profile, to produce beams that can be tuned in the range of 100-400 MeV with percent-level stability, using laser pulses of less than 40 TW. The resulting device is a simple stand-alone accelerator or the front end for a multistage higher-energy accelerator.

43 PARTICLE ACCELERATORS↗

Beneficial influence of Hf and Zr additions to Nb4at%Ta on the vortex pinning of Nb 3 Sn with and without an O source

In this paper we show that addition of Hf to Nb4Ta can significantly improve the high field performance of Nb 3 Sn, making it suitable for dipole magnets for a machine like the 100 TeV Future Circular Collider (FCC). A big challenge of the FCC is that the desired non-Cu critical current density (J c ) target of 1500 A mm –2 (16 T, 4.2 K) is substantially above the best present Nb 3 Sn conductors doped with Ti or Ta (~1300 A mm –2 in the very best sample of the very best commercial wire). Recent success with internal oxidation of Nb–Zr precursor has shown significant improvement in the layer J c of Nb 3 Sn wires, albeit with the complication of providing an internal oxygen diffusion pathway and avoiding degradation of the irreversibility field H Irr . We here extend the Nb1Zr oxidation approach by comparing Zr and Hf additions to the standard Nb4Ta alloy of maximum H c2 and H Irr . Nb4Ta rods with 1Zr or 1Hf were made into monofilament wires with and without SnO 2 and their properties measured over the entire superconducting range at fields up to 31 T. We found that Group IV alloying of Nb4Ta does raise H Irr , though O 2 addition still slightly degrades it. As noted in earlier Nb1Zr work with an O source, the pinning force density F p is strongly enhanced and its peak value shifted to higher field by internal oxidation. A surprising result of this work is that we found better properties in Nb4Ta1Hf without SnO 2 , F pMax achieving 2.35 times that of the standard Nb4Ta alloy, while the oxidized Nb4Ta1Zr alloy achieved 1.54 times that of the Nb4Ta alloy. The highest layer J c (16 T, 4.2 K) of 3700 A mm –2 was found in the SnO 2 -free wire made with Nb4Ta1Hf alloy. Using a standard A15 cross-section fraction of 60% for modern powder-in-tube and rod restack process wires, we estimated that a non-Cu J c of 2200 A mm –2 is obtainable in modern conductors, well above the 1500 A mm –2 FCC specification. Moreover, since the best properties were obtained without SnO 2 , the Nb4Ta1Hf alloy appears to open a straightforward route to enhanced properties in Nb 3 Sn wires manufactured by virtually all the presently used commercial routes employed today.

36 MATERIALS SCIENCE↗

Transverse spin physics at CLAS and CLAS12

We present ongoing and future measurement of spin-azimuthal asymmetries in semi-inclusive production of pions in deep inelastic scattering using the CLAS detector at the Thomas Jefferson National Accelerator Facility (JLab). The azimuthal modulations of the double and single spin asymmetries have been measured in a wide kinematic range, providing access to transverse momentum distributions of partons. An extensive experimental program has been proposed for the upgraded JLab, which will allow precision studies of the transverse structure of the nucleon.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cooperative Support of the Fermilab Site’s Natural Areas and Related Programs (CRADA Final Report)

Under the prime contract with the Department of Energy, Fermi Research Alliance, LLC (FRA) is responsible for effective stewardship of the Fermi National Accelerator Laboratory (Fermilab) 6,800-acre site, to assure that Fermilab is renewed and enhanced to meet future mission needs. As the steward of the Fermilab site, FRA is responsible for maintaining the natural areas for the site (e.g., prairie restoration sites, woodlands, etc.), which are essential for protecting the health and safety of personnel working on or visiting the site, while supporting the scientific and educational missions of Fermilab. Fermilab Natural Areas (FNA) is a not-for-profit corporation organized and existing under the laws of the State of Illinois. FNA was founded in 2006 and incorporated in 2008 for the purposes of studying, conserving, and restoring the Fermilab Site’s natural areas in a manner consistent with the science mission of Fermilab and enhancing the awareness and visibility of the natural amenities of Fermilab to neighboring communities.

54 ENVIRONMENTAL SCIENCES↗

Accelerator-based Neutron Fluence Standard of the National Metrology Institute of Japan

We report the present status of the national standard on accelerator-based fast neutron fluences in Japan. Monoenergetic neutron fluence standards have been established at 144 keV, 565 keV, 5.0 MeV and 8.0 MeV by using a Van de Graaff accelerator and at 2.5 MeV and 14.8 MeV by using a Cockcroft Walton accelerator. These standards are prepared to measure the detection efficiency and the energy response of neutron sensitive devices, such as personal dosimeters and survey meters. Neutron production and absolute fluence measurement for these energies are described. We are developing a new standard in the energy region of a few tens of keV, which is also introduced here as well as our future plans.

43 PARTICLE ACCELERATORS↗

Los Alamos neutron science center nuclear weapons stewardship and unique national scientific capabilities

This presentation gives an overview of the Los Alamos Neutron Science Center (LANSCE) and its contributions to science and the nuclear weapons program. LANSCE is made of multiple experimental facilities (the Lujan Center, the Weapons Neutron Research facility (WNR), the Ultra-Cold Neutron facility (UCN), the proton Radiography facility (pRad) and the Isotope Production Facility (IPF)) served by the its kilometer long linear accelerator. Several research areas are supported, including materials and bioscience, nuclear science, materials dynamics, irradiation response and medical isotope production. LANSCE is a national user facility that supports researchers worldwide. The LANSCE Risk Mitigation program is currently in progress to update critical accelerator equipment to help extend the lifetime of LANSCE as a key user facility. The Associate Directorate of Business Sciences (ADBS) plays an important role in the continued success of LANSCE. This includes key procurement support, human resource support, technical writing support, and training support. LANSCE is also the foundation of the future signature facility MARIE (Matter-Radiation Interactions in Extremes).

43 PARTICLE ACCELERATORS↗

Accelerated High-Resolution Differential Ion Mobility Separations Using Hydrogen

The resolving power of differential ion mobility spectrometry (FAIMS) was dramatically increased recently by the introduction of carrier gases comprising up to 75% He or various vapors, enabling many new applications. However, the gains were often at the expense of analysis speed, in particular making high-resolution FAIMS incompatible with online liquid-phase separations. Here, we report FAIMS employing hydrogen, specifically in mixtures with N2 containing up to 98.4% H2. Such compositions raise the mobilities of all ions and thus resolving power, while avoiding the electrical breakdown inevitable in He-rich mixtures. The increases of resolving power and ensuing peak resolution are especially significant at the greatest H2 fractions - above {approx}80 - 90%. Higher resolution can be exchanged for acceleration of the analyses by up to {approx}20 times. For more mobile species such as multiply-charged peptides, this exchange is presently forced by the constraints of existing FAIMS devices, but future designs optimized for H2 should consistently improve resolution for all analytes.

08 HYDROGEN↗

A hybrid approach for generating ultra-short bunches for advanced accelerator applications

Generation of electron beams with high phase-space density, short bunch length and high peak current is an essential requirement for future linear colliders and bright electron beam sources. Unfortunately, such bunches cannot be produced directly from the source since forces from the mutual repulsion of electrons would destroy the brilliance of the beam within a short distance. Here, we detail a beam dynamics study of an innovative two-stage compression scheme that can generate ultra-short bunches without degrading the beam quality. In the first stage, the beam is compressed with an advanced velocity bunching technique in which the longitudinal phase space is rotated so that electrons on the bunch tail become faster than electrons in the bunch head. In the second stage, the beam is further compressed with a conventional magnetic chicane. With the aid of numerical simulations we show that our two-staged scheme is capable to increase the current of a 50 pC bunch to a notable factor of 100 while the emittance growth can be suppressed to 1% with appropriate tailoring of the initial beam distribution.

43 PARTICLE ACCELERATORS↗

Modeling of advanced accelerator concepts

Computer modeling is essential to research on Advanced Accelerator Concepts (AAC), as well as to their design and operation. This paper summarizes the current status and future needs of AAC systems and reports on several key aspects of (i) high-performance computing (including performance, portability, scalability, advanced algorithms, scalable I/Os and In-Situ analysis), (ii) the benefits of ecosystems with integrated workflows based on standardized input and output and with integrated frameworks developed as a community, and (iii) sustainability and reliability (including code robustness and usability).

47 OTHER INSTRUMENTATION↗

An approach to multiobjective optimization of rotational therapy

Multiobjective optimization is used in radiotherapy, especially IMRT, to generate treatment plans which meet different objectives to varying extents. Trade-off surfaces can be constructed representing the gains and losses of different objectives when switching from one plan to another, and the planner can interactively explore different treatment possibilities without the need for reoptimization. In this work a method for the multiobjective optimization of rotational therapy is introduced. The proposed method is applied slice per slice and uses the geometry of the slice directly to construct several arcs, each conformally irradiating the tumor and blocking a number (0,1,2,...) of different organs at risk present in the treatment. The blocked arc dose distributions so obtained are quite inhomogeneous in the target. An algorithm, based on the iterative reconstruction of images from projections, has been developed to compensate for this inhomogeneity, leading to compensated blocked arcs which deliver more uniform target doses but still block critical structures. Different treatments can be obtained as linear combinations of these arcs, each involving different trade-offs among the objectives involved. The compensatory algorithm substantially improves the target dose uniformity of blocked arcs at the cost of slightly increasing the dose to the rest of the body, allowing delivery of good uniform dose distributions to the target without significantly irradiating the blocked organ(s). Trade-off surfaces are presented for slices containing a target and one or two critical structures. The method is directly implementable using axial or helical tomotherapy. Implementation for conventional linear accelerators will be more difficult because the number of arcs needed to deliver such treatments can be large, an issue to be explored in future work.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

DEVELOPMENT OF THE SNS EXTERNAL ANTENNA H- ION SOURCE

The U.S. Spallation Neutron Source (SNS) is an accelerator-based, pulsed neutron-scattering facility currently in the process of ramping up neutron production. To meet present and future beam current and reliability requirements we are developing an RF-driven, H- ion source based on a ceramic aluminium nitride (AlN) plasma chamber surrounded by an external RF antenna. This report recounts the design of the prototype source, describes the Cs collar variations tested, enumerates recent modifications made to the source to prepare a production version, and summarizes the results of runs on the SNS test stand and Front End (FE) of the SNS accelerator. Up to ~100 mA unanalyzed beam currents (60Hz, 1ms) have been measured on the SNS ion source test stand, and up to 42mA have been successfully accelerated by the RFQ on the SNS front-end at lower RF power.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗