ESSENCE- A rapid, shear-enhanced, flow-through, capacitive electrochemical platform for rapid detection of biomolecules

The rapid, sensitive, and selective detection of target analytes using electrochemical sensors are challenging. ESSENCE, a new Electrochemical Sensor that uses a Shear-Enhanced, flowthrough Nanoporous Capacitive Electrode, overcomes current electrochemical sensors' response limitations, selectivity, and sensitivity limitations. ESSENCE is a microfluidic channel packed with transducer material sandwiched by a top and bottom microelectrode. The room-temperature instrument less integration process allows the switch of the transducer materials to make up the porous electrode without modifying the electrode architecture or device protocol. ESSENCE can be used to detect both biomolecules and small molecules by simply changing the packed transducer material. Electron microscopy results confirm the high porosity. In conjunction with the non-planar interdigitated electrode, the packed transducer material results in a flow-through porous electrode. Electron microscopy results confirm the high porosity. The enhanced shear forces and increased convective fluxes disrupt the electric double layer's (EDL) diffusive process in ESSENCE. This disruption migrates the EDL to high MHz frequency allowing the capture signal to be measured at around 100 kHz, significantly improving device timing (rapid detection) with a low signal-to-noise ratio. The device’s unique architecture allows us multiple configuration modes for measuring the impedance signal. This allows us to use highly conductive materials like carbon nanotubes. We show that by combining single-walled carbon nanotubes as transducer material with appropriate capture probes, NP-µIDE has high selectivity and sensitivity for DNA (fM sensitivity, selective against non-target DNA), breast cancer biomarker proteins (p53, pg/L sensitivity, selective against non-target HER2).

Cheng, Yu-Hsuan↗

Multimodal imaging and machine learning to enhance microscope images of shale

A machine learning based image processing workflow is presented to enhance shale source rock microscopic images obtained using diverse imaging platforms. Images were acquired from a 30 μm diameter cylindrical Vaca Muerta shale sample using both nondestructive Transmission X-Ray Microscopy (TXM, alternately referred to as nano computed tomography) and destructive Focused Ion Beam-Scanning Electron Microscopy (FIB-SEM). Output cross-sectional images from each modality were aligned using a combination of manual and automated registration techniques to create a registered image dataset. We then apply this dataset for two image processing tasks: prediction of image cross sections with SEM-like resolution from nondestructive TXM data and repair of charged region artifacts (localized accumulation of electrons) within SEM images. The image processing algorithms for both tasks use deep learning models, specifically image-to-image Convolutional Neural Networks (CNNs) and conditional Generative Adversarial Networks (cGANs). In the image enhancement tasks, we are able to achieve significant qualitative and quantitative improvement in TXM images. Here, the best model reaches an average Peak Signal to Noise Ratio (PSNR) of 15.8 dB. Conditioning on TXM data is also shown to reduce artifacts from SEM charging, achieving an average PSNR of 25.8 dB. Furthermore, our results suggest that properly trained and validated networks are capable of significant enhancement of images obtained using nondestructive techniques, thereby improving interpretation of two- and three-dimensional images while preserving samples for future use.

58 GEOSCIENCES↗

Methods of measurement for semiconductor materials, process control, and devices

This progress report describes NBS activities directed toward the development of methods of measurement for semiconductor materials, process control, and devices. Significant accomplishments during this reporting period include design of a plan to provide standard silicon wafers for four-probe resistivity measurements for the industry, publication of a summary report on the photoconductive decay method for measuring carrier lifetime, publication of a comprehensive review of the field of wire bond fabrication and testing, and successful completion of organizational activity leading to the establishment of a new group on quality and hardness assurance in ASTM Committee F-1 on Electronics. Work is continuing on measurement of resistivity of semiconductor crystals; characterization of generation-recombination-trapping centers in silicon; study of gold-doped silicon; development of the infrared response technique; evaluation of wire bonds and die attachment; and measurement of thermal properties of semiconductor devices, delay time and related carrier transport properties in junction devices, and noise properties of microwave diodes.

Bullis, W. M.↗

Novel Multiplexing Technique for Detector and Mixer Arrays

Future submillimeter and far-infrared space telescopes will require large-format (many 1000's of elements) imaging detector arrays to perform state-of-the-art astronomical observations. A crucial issue related to a focal plane array is a readout scheme which is compatible with large numbers of cryogenically-cooled (typically < 1 K) detectors elements. When the number of elements becomes of the order of thousands, the physical layout for individual readout amplifiers becomes nearly impossible to realize for practical systems. Another important concern is the large number of wires leading to a 0.1-0.3 K platform. In the case of superconducting transition edge sensors (TES), a scheme for time-division multiplexing of SQUID read-out amplifiers has been recently demonstrated. In this scheme the number of SQUIDs is equal to the number (N) of the detectors, but only one SQUID is turned on at a time. The SQUIDs are connected in series in each column of the array, so the number of wires leading to the amplifiers can be reduced, but it is still of the order of N. Another approach uses a frequency domain multiplexing scheme of the bolometer array. The bolometers are biased with ac currents whose frequencies are individual for each element and are much higher than the bolometer bandwidth. The output signals are connected in series in a summing loop which is coupled to a single SQUID amplifier. The total number of channels depends on the ratio between the SQUID bandwidth and the bolometer bandwidth and can be at least 100 according to the authors. An important concern about this technique is a contribution of the out-of-band Johnson noise which multiplies by factor N(exp 1/2) for each frequency channel. We propose a novel solution for large format arrays based on the Hadamard transform coding technique which requires only one amplifier to read out the entire array of potentially many 1000's of elements and uses approximately 10 wires between the cold stage and room temperature electronics. This can significantly reduce the complexity of the readout circuits.

Karasik, Boris S.↗

Crystallographic variant mapping using precession electron diffraction data

In this work, we developed three methods to map crystallographic variants of samples at the nanoscale by analyzing precession electron diffraction data using a high-temperature shape memory alloy and a VO2 thin film on sapphire as the model systems. The three methods are (I) a user-selecting-reference pattern approach, (II) an algorithm-selecting-reference-pattern approach, and (III) a k-means approach. In the first two approaches, Euclidean distance, Cosine, and Structural Similarity (SSIM) algorithms were assessed for the diffraction pattern similarity quantification. We demonstrated that the Euclidean distance and SSIM methods outperform the Cosine algorithm. We further revealed that the random noise in the diffraction data can dramatically affect similarity quantification. Denoising processes could improve the crystallographic mapping quality. With the three methods mentioned above, we were able to map the crystallographic variants in different materials systems, thus enabling fast variant number quantification and clear variant distribution visualization. The advantages and disadvantages of each approach are also discussed. We expect these methods to benefit researchers who work on martensitic materials, in which the variant information is critical to understand their properties and functionalities.

Crystallographic variant mapping↗

Time-dependent SOLPS-ITER simulations of the tokamak plasma boundary for model predictive control using SINDy *

Abstract Time-dependent SOLPS-ITER simulations have been used to identify reduced models with the sparse identification of nonlinear dynamics (SINDy) method and develop model-predictive control of the boundary plasma state using main ion gas puff actuation. A series of gas actuation sequences are input into SOLPS-ITER to produce a dynamic response in upstream and divertor plasma quantities. The SINDy method is applied to identify reduced linear and nonlinear models for the electron density at the outboard midplane n e , s e p O M P and the electron temperature at the outer divertor T e , s e p d i v . Note that T e , s e p d i v is not necessarily the peak value of T e along the divertor. The identified reduced models are interpretable by construction (i.e. not black box), and have the form of coupled ordinary differential equations. Despite significant noise in T e , s e p d i v , the reduced models can be used to predict the response over a range of actuation levels to a maximum deviation of 0.5% in n e , s e p O M P and 5%–10% in T e , s e p d i v for the cases considered. Model retraining using time history data triggered by a preset error threshold is also demonstrated. A model predictive control strategy for nonlinear models is developed and used to perform feedback control of a SOLPS-ITER simulation to produce a setpoint trajectory in n e , s e p O M P using the integrated plasma simulator framework. The developed techniques are general and can be applied to time-dependent data from other boundary simulations or experimental data. Ongoing work is extending the approach to model identification and control for divertor detachment, which will present transient nonlinear behavior from impurity seeding, including realistic latency and synthetic diagnostic signals derived from the full SOLPS-ITER output.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An evaluation of reaction wheel emitted vibrations for space telescope

Emitted forces and moments characteristics of the Space Telescope Reaction Wheel Assembly (ST RWA) were measured under room temperature and pressure, thermal extremes, and vibratory conditions. The RWA/Emitted Vibration Measurement Fixture was calibrated statically and dynamically, and background noise was measured with ST RWA not operating. A base line set of forces and moments of the ST RWA along and about three mutually perpendicular axes were recorded at room ambient. The temperature vibration sensitivites shown are those which were concluded to be a function of rotor unbalance changes and not associated with either spin motor nor rotor electronic changes.

Source record↗

Polarized polymer films as electronic pulse detectors of cosmic dust particles

A new type of dust particle detector has been developed which consists of a polarized film of polyvinylidene fluoride (PVDF) having conducting electrons on its surface and operating with no bias voltage. Here, the response characteristics of PVDF detectors with areas in the range 4-150 sq cm and thickness in the range 2-28 microns to iron particles accelerated to velocities in the range 1-12 km/s are reported. The discussion also covers the mechanism of detection, fast pulse response, noise characteristics, and the dependence of the detector signal amplitude on particle mass and velocity. The detectors exhibit long-term stability and can be operated for extended periods of time over the temperature range -50 to +50 C; their response to dust particle impacts is unaffected by high background fluxes of charged particles.

Simpson, J. A.↗

A 58 x 62 pixel Si:Ga array camera for 5 - 14 micron astronomical imaging

A new infrared array camera system has been successfully applied to high background 5 - 14 micron astronomical imaging photometry observations, using a hybrid 58 x 62 pixel Si:Ga array detector. The off-axis reflective optical design incorporating a parabolic camera mirror, circular variable filter wheel, and cold aperture stop produces diffraction-limited images with negligible spatial distortion and minimum thermal background loading. The camera electronic system architecture is divided into three subsystems: (1) high-speed analog front end, including 2-channel preamp module, array address timing generator, bias power suppies, (2) two 16 bit, 3 microsec per conversion A/D converters interfaced to an arithmetic array processor, and (3) an LSI 11/73 camera control and data analysis computer. The background-limited observational noise performance of the camera at the NASA/IRTF telescope is NEFD (1 sigma) = 0.05 Jy/pixel min exp 1/2.

Gezari, D. Y.↗

Micromachined silicon tunnel sensor for motion detection

The extreme sensitivity of electron tunneling to variations in electrode separation has been used to construct a novel, compact displacement transducer. Electrostatic forces are used to control the separation between the tunneling electrodes, thereby eliminating the need for piezoelectric actuators. The entire structure is composed of micromachined silicon single crystals, including a folded cantilever spring and a tip. Measurements of displacement sensitivity and noise are reported. This device offers a substantial improvement over conventional technology for applications which require compact, highly sensitive transducers.

Kenny, T. W.↗

Photon-to-Digital Converters for Neutron Imaging Instruments (Final Report)

Oak Ridge National Laboratory (ORNL) collaborated with the Université de Sherbrooke (UdeS) to design a modular and scalable tile of innovative digital photodetectors called Photon-to-Digital Converters (PDC) and the required subsystems to demonstrate the feasibility of large area single-photon detectors to support high-resolution, depth-of-interaction, fast neutron radiography based on scintillation detectors. The goal is to demonstrate the advantages of using PDC over conventional Silicon Photomultiplier (SiPM) for neutron imaging systems. The basic building blocks of analog SiPM and PDC are Single-Photon Avalanche Photodiodes (SPAD). The main difference between conventional SiPMs and PDCs, is in the fact that analog SiPMs sum the charge produced by individual SPAD passively, while in PDCs each SPAD is read out individually by an active electronic circuit. Hence, PDCs provide a direct photon-to-bit conversion where a logic “1” means that there was a detection in a given SPAD. Conversely, an analog SiPM requires a sophisticated preamplifier (current amplifiers or transimpedance amplifier) followed by a shaping amplifier and an analog-to-digital converter. Moreover, since the charge from each SPAD varies slightly, the passive sum of the analog SiPM will have signal fluctuations for the same amount of photon detected. This is one of many issues that is completely eliminated by individual one-to-one SPAD read out in PDCs. The large area required for scintillator readouts for neutron imaging is such that the output capacitance of a large area of SiPM arrays is very high. This creates a burden on the signal-to-noise optimization with respect to the power budget. For PDC, the power consumption is dictated by rate of the incident photon flux, or in photon-starved environments, the dark noise rate of the SPAD array. In other words, the power consumption in the absence of events is extremely low. Hence, the power consumption of a PDC read out system is much lower than its analog counterpart. Further, the large SiPM capacitance may introduce signal distortions on the scintillator fast rise or decay time with undesired effects on timing and pulse shape discrimination. The problem is absent in PDCs, as their readout is independent on device capacitance. UdeS is the world leader in 3D vertical integration of frontside illuminated SPAD arrays over CMOS readouts. These capabilities allow future production of “3D PDC” with maximum photosensitive fill factor and electronic functionalities tailored to the application. UdeS' vast knowledge of SPADs and CMOS design made the team an ideal collaborator in the development of large area high-resolution fast neutron radiography.

42 ENGINEERING↗

Eddy Current Shielding of the Magnetic Field Ripple in the EIC Electron Storage Ring Vacuum Chambers

The EIC electron storage ring (ESR) has very tight tolerances for the beam position and size stability at the interaction point. The oscillations at the proton betatron frequency and its harmonics are the most dangerous because, for instance, they could lead to unacceptable proton emittance growth from the oscillating beam-beam kick from the electrons at the amplitude of the positional oscillations as low as 10 -4 of the beam size. Even at much lower frequencies, down to the single Hz range, the position oscillations at a few percent level of the nominal beam size were found to be dangerous. These oscillations could have different causes including magnet power supply ripple, mag net vibration, noise in the main and crab RF systems, and some collective instabilities. To specify the acceptable level of the current ripple and noise of the magnet power supplies we need to accurately account for the eddy current shielding by the vacuum chamber, as well as, potentially, by the laminated magnet yokes (considered elsewhere). With some ap proximations, the chamber shielding can be described analytically. The main objective of this note is to derive these analytical expressions and to document the resulting shielding performance of the ESR chamber.

43 PARTICLE ACCELERATORS↗

Data Summarization and Inference at Scale

This is the final report for the DOE ASCR grant SC-0022260, Data Summarization and Inference at Scale, PI: Alex Pothen, Purdue University. The goal of the project was to solve data-intensive and compute-intensive problems in the physical sciences, engineering, information science, data science, etc. by designing and implementing new algorithms that could work with a subset of the data. The four subgoals were: (a) The solution of problems where the data is too large to be stored in the memory of a computer. In this streaming model of computation, the data arrives as a stream of elements to the computer, each element is processed as it arrives, and a decision is made to discard the data or to store it; only a small subset of the data proportional to the size of the output solution is stored, and when all the data has been streamed, a solution to the problem is computed from the stored subset. (b) The use of machine learning methods to compute solutions to data-intensive problems. The use of GPUs is critical to obtain high performance on machine learning tasks, but their memory sizes are smaller relative to that of CPUs. For large-scale problems, the data is sampled many times, and small samples are used with repetition, for robustness, to compute solutions to inference tasks. This sampling reduces the memory required to solve the problem, but attention is needed to avoid slow convergence to the solutions, and reduced accuracy of inference. We propose submodular optimization, Large Language Models, and physics-informed neural networks to enable GPU computations here. (c) Modeling and visualization of high-dimensional data using interpretable features. Clinical proteomic data sets from immunology for the detection of cancer and other diseases are temporal and high-dimensional, and algorithms for visualizing these data sets using clinically interpretable features are lacking. We propose methods that compute distances based on the optimal transportation problem and graph edit distances to address this problem. We also propose the use of optimal transport-based distances, spatial statistics, and network structure to classify image data sets, We apply these algorithms to electron micrographs of the peripheral nervous system in the digestive tract. (d) The design of data-intensive algorithms on emerging architectures, specifically, noisy, intermediate-scale quantum (NISQ) devices. Quantum computers offer the possibility of exploring large solution spaces due to the principle of superposition, but current quantum computers are limited by few qubits, short coherence times due to noise, poor interconections among the qubits, etc. We propose the use of the divide and conquer paradigm to solve large-scale problems, wherein collections of small subproblems are solved on the quantum devices, and the solutions to the subproblems are integrated into a solution for the original problem on a classical computer.

97 MATHEMATICS AND COMPUTING↗

Animal exposure during burn tests

An animal exposure test system has been designed and fabricated for the purpose of collecting physiological and environmental (temperature) data from animal subjects exposed to combustion gases in large scale fire tests. The AETS consists of an open wire mesh, two-compartment cage, one containing an exercise wheel for small rodents, and the other containing one rat instrumented externally for electrocardiogram and respiration. The ECG and respiration sensors are located in a belt placed around the torso of the subject, electrode wires forming an umbilical to a connector in the top of the compartment. A cable extends from the connector to the power supply and signal conditioning electronics. These are connected to a dual-beam oscilloscope for real time monitoring and a magnetic tape recorder having three or more channels. Endpoints observed are bradycardia, cardiac arrhythmias, changes in respiratory pattern, respiratory arrest and cardiac arrest. The ECG record also appears to be a good method of monitoring animal activity as indicated by an increase in EMG noise superimposed on the record during increased activity of the torso musculature. Examples of the recordings are presented and discussed as to their significance regarding toxicity of fire gases.

Gaume, J. G.↗

Simplifications of the RELIEF flow tagging system for laboratory use

The use of an O2:He stimulated Raman cell to generate the Stokes beam for the Raman vibrational pumping step of the RELIEF (Raman Excitation plus Laser-Induced Electronic Fluorescence) flow tagging method is reported. Use of the Raman cell rather than a dye laser provides pump and Stokes beams which are automatically frequency matched and temporally and spatially overlapped. The Nd:YAG pump laser is operated multilongitudinal mode, which eliminates the need for injection seeding, resulting in decreased operation complexity and improved stability with respect to acoustic noise. Results are presented for 1st Stokes conversion efficiency and stimulated Brillouin backscattering loss and are compared to the case of pure O2. Scanning CARS measurements of the Q-branch lineshape for both pure O2 and the O2:He mixture are also presented.

Lempert, Walter R.↗

Thermal Infrared Imaging Spectrometer - An advanced optics technology instrument

Through the use of a special optical filter, the Thermal Infrared Imaging Spectrometer, an airborne multispectral IR imaging instrument operating in the thermal emission region (7.5-14 microns), will achieve signal-to-noise ratios greater than 600 with ambient temperature optics. This instrument will be used to do compositional surface mapping of the terrain, and will refine the ability to categorize rock families and types by providing much higher spectral resolution in the emission region than was previously available. Details of the optical system, the detector, the cooler system, and the support electronics are described.

Mahoney, Colin↗