Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

System and method for compact, adaptive optical sensor for obtaining areal images

The present disclosure relates to an imaging system which may make use of an electronic controller, a digital micromirror array, an aperture control system and a detector to image a desired scene. The digital micromirror array has a plurality of micromirror elements responsive to control signals generated by the electronic controller for electronically aiming the micromirror elements in a desired direction to image the desired area, and for receiving and reflecting light emanating from the desired area. The aperture control system receives light reflected from the digital micromirror array and passes a predetermined subportion of the received light therethrough. The detector is responsive to the predetermined subportion of light.

Panas, Robert Matthew↗

Description of the Electronic Structure of Oxyhemoglobin Using Fe L-Edge X-ray Absorption Spectroscopy

The electronic structure of oxyhemoglobin has been controversial since the discovery of the compound’s diamagnetism in 1936. Here, this study uses partial fluorescence yield Fe L-edge X-ray absorption spectroscopy (XAS) in the 3s→2p fluorescence on oxyhemoglobin solutions, measured using a transition-edge sensor detector, to obtain a quantitative experimental description of the electronic structure of the O 2 -bound iron site. The spectrum is very different from typical low-spin Fe II and Fe III heme spectra, and multiplet simulations indicate a mixed ground configuration with ∼57% low-spin Fe III and ∼43% low-spin Fe II character. This is also very different from the Fe II character found for the picket-fence porphyrin model complex. The oxyhemoglobin L-edge XAS data further show that the O 2 ligand engages in a weak σ- but strong π-bond with the iron ion, leading to the overall strong Fe–O 2 bond required for O 2 transport.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of Pixelated Cadmium-Zinc-Telluride Detectors for Astrophysical Applications

Comparisons of charge sharing and charge loss measurements between two pixelated Cadmium-Zinc-Telluride (CdZnTe) detectors are discussed. These properties along with the detector geometry help to define the limiting energy resolution and spatial resolution of the detector in question. The first detector consists of a 1-mm-thick piece of CdZnTe sputtered with a 4x4 array of pixels with pixel pitch of 750 microns (inter-pixel gap is 100 microns). Signal readout is via discrete ultra-low-noise preamplifiers, one for each of the 16 pixels. The second detector consists of a 2-mm-thick piece of CdZnTe sputtered with a 16x16 array of pixels with a pixel pitch of 300 microns (inter-pixel gap is 50 microns). This crystal is bonded to a custom-built readout chip (ASIC) providing all front-end electronics to each of the 256 independent pixels. These detectors act as precursors to that which will be used at the focal plane of the High Energy Replicated Optics (HERO) telescope currently being developed at Marshall Space Flight Center. With a telescope focal length of 6 meters, the detector needs to have a spatial resolution of around 200 microns in order to take full advantage of the HERO angular resolution. We discuss to what degree charge sharing will degrade energy resolution but will improve our spatial resolution through position interpolation.

Gaskin, Jessica↗

Remote Radiation Sensing Using Aerial and Ground Platforms

Remote sensing of ionizing radiation has a significant role in waste management, nuclear material management and nonproliferation, and radiation safety. Robotic platforms can surpass the number of tasks that are achieved by humans. With this technique, the operator's radiation exposure can be decreased. Remote sensing allows for the evaluation and monitoring of radiological contamination. Gamma-ray and neutron sensors were integrated onto the robotic platforms. This approach allows for the radiation sensor data to be dynamically tracked and mapped thus enabling further analysis of the radiation flux in temporal and spatial domains. The goal is to complete scheduled tasks while the robot is being irradiated. To achieve this, electronic components must be shielded and radiation hardened. CZT Detector: Cadmium Zinc Telluride (CZT) detector technology has been a promising solution for gamma-ray and x-ray measurements. Detector data is transferred to the Odroid minicomputer that controls and powers the module via the USB. Robot Operating System (ROS) was utilized for data acquisition and data fusion. The Mariscotti method was employed for the spectrum analysis. A function was programmed in ROS for the automatic identification of photopeaks. CLYC Detector: A Cs{sub 2}LiYCl{sub 6}:Ce{sup 3+} (CLYC) detector was used for simultaneous medium-resolution gamma-ray measurements and neutron counting. A 2.54 cm diameter photomultiplier tube (PMT) was equipped with a high voltage supply and a miniature digitizer. Gamma-ray excitation: fast core-to-valence luminescence (CVL) with 1 ns decay constant, and prompt Ce{sup 3+} emission with 50 ns decay constant. Neutron excitation: slow cerium self-trapped excitation (Ce{sup 3+} STE), 1000 ns decay constant. Radiation Source Localization: Maximum Likelihood Estimation (MLE) and gradient-based methods were used to locate the position of a radiation source based on measured radiation intensities. Multi-Particle Transport Code FLUKA: Estimation of radiation damage of the electronic components is important in order to optimize the robot's operational time while it is irradiated. Displacement per atom (DPA) represents the radiation damage in materials exposed to the ionizing radiation. Various shielding layers of different thickness t were analyzed (< 5% statistical error). The model of the controller of the UAS was designed in FLUKA. Conclusion: CZT and CLYC detectors were integrated onto the robotic platforms. Radiation source localization and contour mapping using robotic platforms were studied. Functions for data analysis and fusion were developed in ROS. FLUKA code was utilized to analyze DPA values. Layers of low-density and high-density materials were used to shield the UAS electronics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Complementary Barrier Infrared Detector

The complementary barrier infrared detector (CBIRD) is designed to eliminate the major dark current sources in the superlattice infrared detector. The concept can also be applied to bulk semiconductor- based infrared detectors. CBIRD uses two different types of specially designed barriers: an electron barrier that blocks electrons but not holes, and a hole barrier that blocks holes but not electrons. The CBIRD structure consists of an n-contact, a hole barrier, an absorber, an electron barrier, and a p-contact. The barriers are placed at the contact-absorber junctions where, in a conventional p-i-n detector structure, there normally are depletion regions that produce generation-recombination (GR) dark currents due to Shockley-Read- Hall (SRH) processes. The wider-bandgap complementary barriers suppress G-R dark current. The barriers also block diffusion dark currents generated in the diffusion wings in the neutral regions. In addition, the wider gap barriers serve to reduce tunneling dark currents. In the case of a superlattice-based absorber, the superlattice itself can be designed to suppress dark currents due to Auger processes. At the same time, the barriers actually help to enhance the collection of photo-generated carriers by deflecting the photo-carriers that are diffusing in the wrong direction (i.e., away from collectors) and redirecting them toward the collecting contacts. The contact layers are made from materials with narrower bandgaps than the barriers. This allows good ohmic contacts to be made, resulting in lower contact resistances. Previously, THALES Research and Technology (France) demonstrated detectors with bulk InAsSb (specifically InAs0.91Sb0.09) absorber lattice-matched to GaSb substrates. The absorber is surrounded by two wider bandgap layers designed to minimize impedance to photocurrent flow. The wide bandgap materials also serve as contacts. The cutoff wavelength of the InAsSb absorber is fixed. CBIRD may be considered as a modified version of the THALES double heterostructure (DH) p-i-n device, but with even wider bandgap barriers inserted at the contact layer/absorber layer interfaces. It is designed to work with either bulk semiconductors or superlattices as the absorber material. The superlattice bandgap can be adjusted to match the desired absorption cutoff wavelength. This infrared detector has the potential of high-sensitivity operation at higher operating temperatures. This would reduce cooling requirements, thereby reducing the power, mass, and volume of the equipment and allowing an increased mission science return.

Ting, David Z.↗

Radiation Design of Ion Mass Spectrometers

In the harsh radiation environment of Jupiter and with the JUpiter ICy moon Explorer (JUICE) mission including two Europa flybys where local intensities are approx. 150 krad/month behind 100 mils of Al shielding, so background from penetrating radiation can be a serious issue for detectors inside an Ion Mass Spectrometer (IMS). This can especially be important for minor ion detection designs. Detectors of choice for time-of-flight (TOF) designs are microchannel plates (MCP) and some designs may include solid state detectors (SSD). The standard approach is to use shielding designs so background event rates are low enough that the detector max rates and lifetimes are first not exceeded and then the more stringent requirement that the desired measurement can successfully be made (i.e., desired signal is sufficiently greater than background noise after background subtraction is made). GEANT codes are typically used along with various electronic techniques, but such designs need to know how the detectors will respond to the simulated primary and secondary radiations produced within the instrument. We will be presenting some preliminary measurements made on the response of MCPs to energetic electrons (20 ke V to 1400 ke V) using a Miniature TOF (MTOF) device and the High Energy Facility at Goddard Space Flight Center which has a Van de Graaff accelerator.

Sittler, Ed↗

Topmetal CMOS direct charge sensing plane for neutrinoless double-beta decay search in high-pressure gaseous TPC

We propose a novel charge sensing concept for high-pressure Time Projection Chamber (TPC) to search for Neutrinoless Double-Beta Decay (NLDBD) with ton-scale isotope mass and beyond. A meter-sized plane, tiled with an array of CMOS integrated sensors called Topmetal that directly collect charge without gas avalanche gain, is to be deployed into a high-pressure gaseous TPC with working gases containing suitable NLDBD candidate isotopes such as Xe-136 and Se-82. The Topmetal sensor has an electronic noise <30 e- per pixel, which allows the detector to reach <1% FWHM energy resolution at the NLDBD Q-value for both Xe-136 and 82SeF6 gases by measuring ionization charges alone. The elimination of charge avalanche gain allows the direct sensing of slow-drifting ions, which enables the use of highly electronegative gas SeF6 in which free electrons do not exist. It supports the swapping of working gases without hardware modification, which is a unique way to validate signals against radioactive backgrounds. Since the sensor manufacturing and plane assembling could leverage unaltered industrial mass-production processes, stability, uniformity, scalability, and cost-effectiveness that are required for ton-scale experiments could all be reached. The strengths of TPC such as 3D ionization tracking and decay daughter tagging are retained. This development could lead to a competitive NLDBD experiment at and above ton-scale. The conceptual considerations, simulations, and initial prototyping are discussed.

Mei, Yuan↗

Characterization of the scintillation time response of liquid argon detectors for dark matter search

The scintillation time response of liquid argon has a key role in the discrimination of electronic backgrounds in dark matter search experiments. However, its extraordinary rejection power can be affected by various detector effects such as the delayed light emission of TetraPhenyl Butadiene, the most commonly used wavelength shifter, and the electric drift field applied in Time Projection Chambers. Herein, we characterized the TetraPhenyl Butadiene delayed response and the dependence of the pulse shape discrimination on the electric field, exploiting the data acquired with the ARIS, a small-scale single-phase liquid argon detector exposed to monochromatic neutron and gamma sources at the ALTO facility of IJC Lab in Orsay.

47 OTHER INSTRUMENTATION↗

Determination of particle-dependent light response for defining detector response functions

This study comprehensively characterizes two scintillation detectors, an organic deuterated liquid and a stilbene crystal, concerning their response to charged particles such as electrons, protons, alphas, and carbon nuclei. The Birks function was used to determine the detectors’ response to charged particles, enabling the determination of particle-dependent light responses. The particle-dependent light characterization was used to determine detector response functions (DRF) using Geant in combination with Gamma Detector Response and Analysis Software (GADRAS). These DRFs enhance GADRAS by enabling full spectral analysis functionality for previously underrepresented detector materials. Additionally, neutron-specific DRFs are determined for neutron energy spectrum unfolding applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Small area silicon diffused junction X-ray detectors

The low-temperature performance of silicon diffused junction detectors in the measurement of low energy X-rays is reported. The detectors have an area of 0.04 sq cm and a thickness of 100 microns. The spectral resolutions of these detectors were found to be in close agreement with expected values, indicating that the defects introduced by the high-temperature processing required in the device fabrication were not deleteriously affecting the detection of low-energy X-rays. Device performance over a temperature range of 77 K to 150 K is given. These detectors were designed to detect low-energy X-rays in the presence of minimum ionizing electrons. The successful application of silicon-diffused junction technology to X-ray detector fabrication may facilitate the development of other novel silicon X-ray detector designs.

Walton, J. T.↗

Assessment of deep levels with selenium concentration in Cd 1–x Zn x Te 1–y Se y room temperature detector materials

Incorporation of Se into Cd 1–x Zn x Te (CZT) to form the quaternary compound semiconductor Cd 1–x Zn x Te 1–y Se y (CZTS) has proven to be an effective solution for compensating the major flaws associated with CZT, including poor homogeneity and high concentrations of electronically active deep levels that limit the performance of CZT detectors. In order to investigate how deep levels are affected by the Se concentration in CZTS, we performed photoinduced current transient spectroscopy (PICTS) measurements on CZTS crystals grown by the traveling heater method (THM) with 10% atomic Zn and varying atomic percentage of Se from 1.5% to 7.0%. The PICTS scans for up to 4% Se showed an exponential reduction in the capture cross section of deep levels associated with Te secondary phases in conjunction with an increase in a deep level positioned near the mid-gap, which initially increases the electron trapping time before degrading again at higher Se concentrations. The PICTS peaks present in 7% Se were anomalous relative to the other crystals and are expected to originate from transition metal impurities found in the lower-purity CdSe precursor material.

36 MATERIALS SCIENCE↗

SBND Shower Reconstruction with SPINE

The Short-Baseline Near Detector (SBND) is a liquid argon time projection chamber (LArTPC) neutrino detector in the Short-Baseline Neutrino (SBN) program at Fermilab. SBND is designed to investigate the Low-Energy Excess (LEE), an unexplained excess of electron-like events observed by previous short-baseline neutrino experiments that may point to physics beyond the Standard Model. In LArTPC detectors, precise shower reconstruction is essential for distinguishing electrons from photons, a key requirement for testing possible explanations of the LEE and improving $\nu_e$ event selection. In this poster, the reconstruction studies using the Scalable Particle Imaging with Neural Embeddings (SPINE), a machine learning based reconstruction framework for particle imaging detectors will be presented. SPINE combines sparse convolutional neural networks (CNN) and graph neural networks (GNN) to enable detailed reconstruction and characterization of neutrino interactions in LArTPC detectors. Shower calorimetry and kinematic reconstruction are performed in dedicated post-processing stages. Strong agreement between data and Monte Carlo simulation will be demonstrated, indicating high-precision detector calibration and reconstruction performance. The agreement between reconstructed and true electron shower energy will also be discussed, emphasizing the robustness of the shower reconstruction performance. These results demonstrate the unprecedented precision achievable with SPINE in SBND, highlighting their potential for future high-resolution neutrino measurements.

Fan, Castaly [Florida U.; Fermilab] (ORCID:0000000↗

Soft x ray window encapsulant for HgI2 detectors

HgI2 is an excellent semiconductor material for a low energy, room temperature x-ray spectrometer. The high values of the atomic numbers for its constituent elements gives high x-ray and gamma ray stopping power. The band gap of HgI2 is significantly higher than other commonly used semiconductors. Owing to the large value band gap, the leakage current for HgI2 devices is smaller, thus allowing low noise performance. Devices fabricated from HgI2 crystals have demonstrated energy resolution sufficient to distinguish the x-ray emission from the neighboring elements on the periodic table. Also the power requirements of HgI2 are very low. These characteristics make a HgI2 spectrometer an ideal component in a satellite based detection system. Unfortunately, HgI2 crystals tend to deteriorate with time, even if protected by standard semiconductor encapsulants. This degradation ruins the performance of the device in terms of its energy resolution and pulse amplitude. The degrading mechanism is believed to be material loss occurring from below the electrodes, due to high vapor pressure of HgI2 at room temperature. To address this major obstacle to rapid expansion of HgI2 technology, a research program aimed at improving device stability by encapsulation with inert polymeric materials was carried out. The program focused specifically on optimizing the encapsulant materials and their deposition techniques. The principal objectives for this program were device encapsulation, device testing, and accelerated testing to ensure very long term stability of these high resolution sensors. A variety of encapsulants were investigated with the selection criteria based on their chemical diffusion barrier properties, mechanical stability, reactivity, and morphology of encapsulant films. The investigation covered different classes of encapsulants including solvent based encapsulants, vapor deposited encapsulants, and plasma polymerized encapsulants. A variety of characterization techniques were employed to examine their effectiveness in stabilizing HgI2 devices; these included permeability evaluation, vacuum and heat testing, scanning electron microscopy (SEM) as well as studying the detector performance of coated detectors. The plasma polymerized films appear to have entirely solved the HgI2 degradation problem. Another achievement of this program was the development of an accelerated testing technique which correlates extremely well with long term tesing.

Entine, G.↗

Readout optimization of multi-amplifier sensing charge-coupled devices for single-quantum measurement

The non-destructive readout capability of the Skipper Charge Coupled Device (CCD) has been demonstrated to reduce the noise limitation of conventional silicon devices to levels that allow single-photon or single-electron counting. The noise reduction is achieved by taking multiple measurements of the charge in each pixel. These multiple measurements come at the cost of extra readout time, which has been a limitation for the broader adoption of this technology in particle physics, quantum imaging, and astronomy applications. This work presents recent results of a novel sensor architecture that uses multiple non-destructive floating-gate amplifiers in series to achieve sub-electron readout noise in a thick, fully-depleted silicon detector to overcome the readout time overhead of the Skipper-CCD. This sensor is called the Multiple-Amplifier Sensing Charge-Coupled Device (MAS-CCD) can perform multiple independent charge measurements with each amplifier, and the measurements from multiple amplifiers can be combined to further reduce the readout noise. We will show results obtained for sensors with 8 and 16 amplifiers per readout stage in new readout operations modes to optimize its readout speed. The noise reduction capability of the new techniques will be demonstrated in terms of its ability to reduce the noise by combining the information from the different amplifiers, and to resolve signals in the order of a single photon per pixel. The first readout operation explored here avoids the extra readout time needed in the MAS-CCD to read a line of the sensor associated with the extra extent of the serial register. The second technique explore the capability of the MAS-CCD device to perform a region of interest readout increasing the number of multiple samples per amplifier in a targeted region of the active area of the device.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Selection Algorithm for electron neutrino charged current interactions in SBND

The Short Baseline Neutrino (SBN) program at Fermilab is a joint proposal by three experimental collaborations primarily for the investigation of the cause behind the low-energy electron-like event excess observed by the MiniBoone experiment. This dissertation focuses on the near detector of the project, named the Short Baseline Near Detector (SBND), a Liquid Argon Time Projection Chamber apparatus which will conduct searches for sterile neutrinos in the mass range of 1 ${eV}^2/{c}^4$, as well as provide cross-section measurements for neutrino interactions in argon and perform other beyond the standard model studies.\\ \indent As is the case for all detectors in the program, the SBND will use the Booster Neutrino Beam as its source, which will provide it with both muon and electron neutrinos. Given that the ability to discern between the neutrino flavors will be crucial to the fulfillment of the detector's physics goals, the objective of this work is to provide the collaboration with a tool capable of doing so. As such, we here present the development process for an inclusive selection algorithm for the identification of electron neutrino charged current (CC) events regardless of their interaction channel. This is done through a combination of traditional techniques, such as the implementation of cuts on the reconstructed interaction properties, with the use of the Convolutional Visual Network, a machine learning algorithm capable of classifying particle interactions through the analysis of the topology of their final states. With this approach, we have developed a selection process that is capable of identifying $\nu_e$ CC interactions across a wide range of topologies with 34.4\% efficiency, as well as a purity of 91.2\%, making it especially promising for use in cross section studies.

Freire, Hector Moya [ABC Federal U.] (ORCID:000900↗

The CLAS12 forward electromagnetic calorimeter

The CLAS12 Forward Detector includes six independent lead-scintillator electromagnetic sampling calorimeters to provide the primary electron trigger and extend the CLAS12 detection capability to photons and neutrons. Each calorimeter package consists of two modules, the legacy Electromagnetic Calorimeter (EC) previously used in the CLAS detector, and a new pre-shower calorimeter (PCAL) located in front of the EC to extend the total detector radiation length, in order to fully absorb the electromagnetic showers induced by electrons with energies up to 12 GeV. Both calorimeters use a novel triangular hodoscope geometry with stereo readout. The PCAL uses an upgraded design to provide the high spatial resolution necessary for reconstructing π 0 and η decays, and neutrons with high efficiency. Here, this paper treats the design, construction, and calibration of the PCAL and the preliminary combined performance of both detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Flight of the Gamma-Ray Imager Polarimeter for Solar Flares (GRIPS) Instrument

The Gamma-Ray Imager/Polarimeter for Solar ares (GRIPS) instrument is a balloon-borne telescope designed to study solar-flare particle acceleration and transport. We describe GRIPS's first Antarctic long-duration flight in January 2016 and report preliminary calibration and science results. Electron and ion dynamics, particle abundances and the ambient plasma conditions in solar flares can be understood by examining hard X-ray (HXR) and gamma-ray emission (20 keV to 10 MeV). Enhanced imaging, spectroscopy and polarimetry of flare emissions in this energy range are needed to study particle acceleration and transport questions. The GRIPS instrument is specifically designed to answer questions including: What causes the spatial separation between energetic electrons producing hard X-rays and energetic ions producing gamma-ray lines? How anisotropic are the relativistic electrons, and why can they dominate in the corona? How do the compositions of accelerated and ambient material vary with space and time, and why? GRIPS's key technological improvements over the current solar state of the art at HXR/gamma-ray energies, the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI), include 3D position-sensitive germanium detectors (3D-GeDs) and a single-grid modulation collimator, the multi-pitch rotating modulator (MPRM). The 3D-GeDs have spectral FWHM resolution of a few hundred keV and spatial resolution less than 1cu mm. For photons that Compton scatter, usually greater or equal to 150 keV, the energy deposition sites can be tracked, providing polarization measurements as well as enhanced background reduction through Compton imaging. Each of GRIPS's detectors has 298 electrode strips read out with ASIC/FPGA electronics. In GRIPS's energy range, indirect imaging methods provide higher resolution than focusing optics or Compton imaging techniques. The MPRM grid-imaging system has a single-grid design which provides twice the throughput of a bi-grid imaging system like RHESSI. The grid is composed of 2.5 cm deep tungsten-copper slats, and quasi-continuous FWHM angular coverage from 12.5-162 arcsecs are achieved by varying the slit pitch between 1-13 mm. This angular resolution is capable of imaging the separate magnetic loop footpoint emissions in a variety of are sizes. In comparison, RHESSI's 35-arcsec resolution at similar energies makes the footpoints resolvable in only the largest ares.

Duncan, Nicole↗