Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “depth data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Soil moisture, physical and chemical properties coincident with airborne SAR data collections for 2017 and 2019, Seward Peninsula, Alaska

Soil samples were collected coincident with in-situ soil moisture and thaw depth measurements at NGEE Arctic study sites on the Seward Peninsula, Alaska in August 2017 and 2019 Field measurements and flights were conducted during both summers as a collaboration between the NASA ABoVE Project's Airborne SAR Campaign and the NGEE Arctic Project. Airborne overflights of L-band SAR instruments occurred during the soil sampling periods. Laboratory measurements of soil properties include bulk density, volumetric and gravimetric water content, carbon and nitrogen content, and particle size of mineral components. Soil samples processed and reported in this dataset were collected coincident with in situ measurements of soil moisture and thaw depth and airborne P-band and L-band SAR measurements as a collaboration between NGEE Arctic and NASA ABoVE. To learn more about how ABoVE protocols were applied for sampling site selection and making in situ measurements, see the following datasets: (2017: https://doi.org/10.5440/1423892 and 2019: https://doi.org/10.5440/1856042). Contained in this dataset are four .csv data files (including data dictionaries) and one zipped folder of *.pdf files.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort (with some overlap with Covid-19 pandemic) to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Retrospective Analysis of Backwater Habitat Availability Using Remote Sensing

Low-velocity channel-margin habitats serve as important nursery habitats for the endangered Colorado pikeminnow (Ptychocheilus lucius) in the middle Green River between Jensen and Ouray, Utah. These habitats, known as backwaters, are associated with emergent sandbars, and are shaped and reformed annually by peak flows. Our recent knowledge about backwater characteristics and dynamics that is summarized in the synthesis report (Grippo et al. 2015) was based on detailed annual survey data from a relatively small sample of backwaters that were collected from 2003 to 2014 and reach-wide evaluations of backwater surface area based on manual interpretation of aerial and satellite imagery. Methods that bridge the gap between the detailed surveys from a small number of backwaters and the reach-wide assessment of their surface area would enable an assessment of the availability of backwater habitats that meet the minimum depth requirements for suitable habitat for Colorado pikeminnow. In 2015 Argonne National Laboratory (Argonne) tested three regression models—linear, multiple, and partial least square (PLS) regression models—for estimating backwater depth using National Agriculture Imagery Program (NAIP) imagery collected in July 2006 that covered the Jensen-Ouray reach of the Green River (Hamada and LaGory 2016). The results suggested that a PLS regression model showed high correlation with the reference depth (R 2 = 0.69) and had the most unbiased and consistent estimate of backwater depth. The results also indicated that the PLS model would provide reasonable estimates of the amount of habitat providing a minimum suitable depth of 30 cm for young-of-the-year Colorado pikeminnow, even though absolute depth estimates may be uncertain for backwater areas deeper than approximately 40 cm. The study also provided insights regarding the amount and the selection of calibration and validation (cal-val) data needed for improving the accuracy of depth prediction.

54 ENVIRONMENTAL SCIENCES↗

INFRARED IMAGING OF CARBON AND CERAMIC COMPOSITES: DATA REPRODUCIBILITY

Infrared NDE techniques have proven to be superior for imaging of flaws in ceramic matrix composites (CMC) and carbon silicon carbide composites (C/SiC). Not only can one obtain accurate depth gauging of flaws such as delaminations and layered porosity in complex-shaped components such as airfoils and other aeronautical components, but also excellent reproducibility of image data is obtainable using the STTOF (Synthetic Thermal Time-of-Flight) methodology. The imaging of large complex shapes is fast and reliable. This methodology as applied to large C/SiC flight components at the NASA Dryden Flight Research Center will be described.

36 MATERIALS SCIENCE↗

Local H i emissivity measured with Fermi-LAT and implications for cosmic-ray spectra

Cosmic-ray (CR) electrons and nuclei interact with the Galactic interstellar gas and produce high-energy γ-rays. The γ-ray emission rate per hydrogen atom, called emissivity, provides a unique indirect probe of the CR flux. We present the measurement and the interpretation of the emissivity in the solar neighborhood for γ-ray energy from 50 MeV to 50 GeV. We analyzed a subset of 4 yr of observations from the Large Area Telescope (LAT) aboard the Fermi Gamma-ray Space Telescope (Fermi) restricted to absolute latitudes 10{sup ∘}<|b|<70{sup ∘}. From a fit to the LAT data including atomic, molecular, and ionized hydrogen column density templates, as well as a dust optical depth map, we derived the emissivities, the molecular hydrogen–to–CO conversion factor X{sub CO}=(0.902±0.007)×10{sup 20} cm{sup −2} (K km s{sup −1}){sup −1}, and the dust-to-gas ratio X{sub DUST}=(41.4±0.3)×10{sup 20} cm{sup −2} mag{sup −1}. Moreover, we detected for the first time γ-ray emission from ionized hydrogen. We compared the extracted emissivities to those calculated from γ-ray production cross sections and to CR spectra measured in the heliosphere. We observed that the experimental emissivities are reproduced only if the solar modulation is accounted for. This provides a direct detection of solar modulation observed previously through the anticorrelation between CR fluxes and solar activity. Finally, we fitted a parameterized spectral form to the heliospheric CR observations and to the Fermi-LAT emissivity and obtained compatible local interstellar spectra for proton and helium kinetic energy per nucleon between between 1 and 100 GeV and for electron–positrons between 0.1 and 100 GeV.

79 ASTRONOMY AND ASTROPHYSICS↗

Sub-daily virus sampling at the Bermuda Atlantic Time Series reveals diel and depth-structured population dynamics without community-level shifts

Ocean microbes contribute to biogeochemical cycles and ecosystem function, but they do so under top-down pressure imposed by viruses. While viruses are increasingly understood spatially and beginning to be incorporated into predictive modeling, high-frequency ocean virus dynamics remain understudied due to methodological challenges. Here we sampled stratified Bermuda Atlantic Time Series (BATS) waters for 112 hours at sub-daily 4- (surface) or 12- (deep chlorophyll maximum) hour intervals, purified viral particles from these samples, sequenced their metagenomes, and used the resulting data to characterize high-frequency virus community dynamics. Aggregated community diversity metrics changed with depth, but were not statistically significant temporally at a fixed location. However, finer-scale population-level analyses revealed both depth and temporal change, including physicochemical depth-driven differences and, in surface waters, thousands of viral populations that exhibited statistically significant diel rhythms. Statistical analyses revealed three main archetypes of temporal dynamics that themselves differed in abundance patterns, host predictions, viral taxonomy, and gene functions. Among these, highlights include viruses resembling an archetype with a night peaking pattern in activity that include an over-representation of viruses that putatively infect Prochlorococcus, a phototrophic cyanobacteria. Together, these efforts provide baseline community- and population-scale short-time-frame observations relevant to future climate state modeling.

Carrillo, Alfonso [The Ohio State University, Colu↗

SU-F-T-495: Method for Simultaneous Commissioning of Multiple Truebeam (TB) Linacs: Small Field Data and the Choice of Dosimetric Lead Gap (DLG)

Purpose: Many times a set of multiple Varian-Truebeam (TB) linacs are acquired by an institution. Since “beam matching” is an important requirement for many facilities, we developed a strategy to perform a “simultaneous” commissioning between multiple linacs.Methods and Materials: We first commissioned the required photon beam data for eclipse on the 1st TB for all the energy modalities with a beam scanning system, while integrated measurements for output factors, of all field sizes (from 1×1 to 40×40cm{sup 2}) were conducted on the 2nd TB. Care was exercised during small field dosimetry so the appropriate detectors were used with data taken between two detectors be “linked” to a larger field size (4×4cm{sup 2}) with the “daisy-chaining” technique via: OF=[M-PTW(fs)×(M-PTW(4×4))-1]×[MA12s(4×4)×(M-A12S(10×10))−1]. For all energy modalities, data that span the entire range of field size, was repeated on the next TB linac, for verification. The primarily energy-dependent dosimetric leaf gap (DLG) which was measured separately on each TB. The modeled data was validated with special measurements conducted on both linacs during commissioning. Results: Our data agreed with the “TB representative beam data” to within 0.5% for all energy modalities and field sizes ≥3×3cm2. Sample depth-doses and cross-profiles of a 3×3cm2 between the linacs agreeing to within 1% between linacs. The measured DLGs were quite different with a uniform difference of 1.3% between the two linacs. The measured DLG values are independent of the average dose rate and medium used for the measurements. Conclusion: A comprehensive method of commissioning identical Varian-TB linacs, outlining the critical issues, especially small field dosimetry and DLG. The dosimetric effect of different DLG values, when it comes to, dynamic delivery and data comparisons will be presented. The dependence of DLG value on the measurement medium (in-air vs. water) or dose rate used will also be discussed. This work was supported by CAMC Cancer Center and Alliance Oncology.

61 RADIATION PROTECTION AND DOSIMETRY↗

Review of atomic data needs for active charge-exchange spectroscopy on ITER

The quantitative exploitation of active beam spectra is largely based on an advanced atomic modeling. Under the ITER operating conditions the penetration depth of a diagnostic beam into the plasma core crucially affects the intensities of spectral lines and hence the uncertainties of derived plasma parameters. A critical review of atomic data and an assessment of its error margins are, therefore, urgently needed. The aim of the present work is to verify the existing beam-stopping and beam-emission data for hydrogen beam in fusion plasmas. The agreement between the ADAS database and the present calculations is found to be within 5% for the beam-stopping data in a H-plasma. The calculation of beam attenuation in the presence of He-ash (4%) and Be ions (2%) demonstrates the agreement between the present data and the ADAS database within 10%. Finally, the maximum deviation of 15% is found only for beam-emission data at the electron density of 1x10{sup 12}-2x10{sup 12} cm{sup -3}, which is significantly below the ITER density of 10{sup 14} cm{sup -3}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Geothermal Play-Fairway Analysis of Washington State Prospects: Final Report

The Washington State Geothermal Play-Fairway Analysis overcomes the exploration challenges posed by dense vegetation, glacial deposits, and extreme precipitation. The geothermal play-fairways we target are locations where heat, permeability, and saturated porosity are present in sufficient volume to provide adequate heat exchange at depths accessible by modern drilling technology. The three study areas lie along the Cascade Range magmatic arc and are near Mount Baker, Mount St. Helens, and the Wind River Valley. The seven-year project is divided into three phases. In Phase 1 we build on a previous statewide assessment of geothermal resources and develop an initial modeling approach. The results are a series of favorability, uncertainty, and risk maps for three targeted study areas. Based on these initial results, we collect new geologic and geophysical data to further refine our modeling and reduce exploration uncertainty in Phase 2. We improve the modeling method to handle the new data and update the favorability, uncertainty, and risk maps. We also update the conceptual geothermal resource models. In Phase 3 we validate our modeling approach by drilling two temperature-gradient holes and collecting and analyzing core, image logs, and new geochemistry. Our modeling approach improves on an earlier statewide method through a more-rigorous and detailed assessment of heat and permeability. Permeability potential is assessed through geomechanical modeling of the deformation that can generate and maintain reservoir porosity and permeability. Metrics to inform heat potential include temperature-gradient wells, which are sparse in Washington; proximity of Quaternary volcanic vents and young intrusive rock; spring temperature; and reservoir temperature inferred from geothermometry. We weight the individual components using an expert-guided approach known as the Analytical Hierarchy Process. During Phase 2 we also develop a fluid-filled fracture model, and an infrastructure model that helps to delineate areas which are more favorable for geothermal development based on proximity to transmission lines, elevation, land ownership and use restrictions, and availability of process water. New geologic and geophysical data is collected during Phase 2 in each of our three main study areas. At Mount Baker and north of Mount St. Helens we conduct 1:24,000-scale geologic mapping and lidar analysis to better constrain the location and character of surface faults; detailed mapping in the Wind River Valley was completed just prior to the start of this project. Ages of intrusive rocks are determined with 40 Ar/ 39 Ar geochronology, though all of our samples are Miocene or older. We collect ground based gravity observations (a total of 1,580 new stations) in all of our study areas and ground-based magnetic lines (a total of 93 km) at Mount Baker. These data are combined with existing gravity and aeromagnetic data and used to constrain fault locations and geometry. Two to three cross sections are constructed at each study area using the mapped surface geology and forward-modeling of the gravity and magnetic data; these cross sections form the basis for our updated conceptual models. We collect magnetotelluric surveys at Mount Baker and Mount St. Helens and these data are inverted to form a resistivity model from the surface to about 10 km depth; each model shows conductive zones that can be interpreted as upwelling geothermal fluids. At Mount St. Helens we deploy a passive seismic array and use the newly detected events to refine the location of the Saint Helens seismic zone. We also employ ambient-noise tomography to develop a detailed seismic-velocity model for the study area and use this model to help constrain our cross sections and conceptual model. Based on the new data collected during Phase 2—and our updated models—we develop a campaign of temperature-gradient holes and core analysis to validate our modeling in Phase 3. Drill hole MB76-31 is located near Little Park Creek, 11 km west-southwest of the summit of Mount Baker, and is 1,471 ft deep. About 410 ft of core from the lower portion of the hole—and image logs from ~175 ft below ground surface to the bottom—are collected and analyzed. Water samples are collected and processed for geothermometry. Drill hole MSH17-24 is located along upper Schultz Creek, 16 km north-northeast of Mount St. Helens and has core from 470 ft to the bottom at 1,053 ft. We did not collect image logs due to borehole stability concerns, but water samples are collected and analyzed for geothermometry. Repeat temperature-gradient measurements are made at both sites and thermal conductivity is measured from core samples. At MB76-31, the equilibrated temperature gradient of 64°C/km and calculated heat flow of 141–159 mW/m 2 is more than twice the regional average. Detailed mapping and analysis of the core, coupled with correlation to the image logs, indicates a history of permeability generation consistent with our predictions of high permeability. Because the site has high favorability in the Phase 2 model, we consider the results a positive validation of the modeling. At site MSH17-24, the equilibrated temperature gradient of ~15°C/km and calculated heat flow of 41–43 mW/m 2 are similar to regional. Geochemical analysis of the water samples indicates a meteoric source without any geothermal component. Detailed outcrop-based mapping of fault exposures near the drill site and analysis of image logs from nearby boreholes indicates a history of permeability generation consistent with our predictions. Because the site has low favorability in the Phase 2 model, we consider the results a positive validation of the modeling. Together, the two sites provide a reasonably positive validation of the Phase 2 modeling and should encourage future use of this modeling approach.

15 GEOTHERMAL ENERGY↗

SU-F-P-19: Fetal Dose Estimate for a High-Dose Fluoroscopy Guided Intervention Using Modern Data Tools

Purpose: An accurate dose estimate is necessary for effective patient management after a fetal exposure. In the case of a high-dose exposure, it is critical to use all resources available in order to make the most accurate assessment of the fetal dose. This work will demonstrate a methodology for accurate fetal dose estimation using tools that have recently become available in many clinics, and show examples of best practices for collecting data and performing the fetal dose calculation. Methods: A fetal dose estimate calculation was performed using modern data collection tools to determine parameters for the calculation. The reference point air kerma as displayed by the fluoroscopic system was checked for accuracy. A cumulative dose incidence map and DICOM header mining were used to determine the displayed reference point air kerma. Corrections for attenuation caused by the patient table and pad were measured and applied in order to determine the peak skin dose. The position and depth of the fetus was determined by ultrasound imaging and consultation with a radiologist. The data collected was used to determine a normalized uterus dose from Monte Carlo simulation data. Fetal dose values from this process were compared to other accepted calculation methods. Results: An accurate high-dose fetal dose estimate was made. Comparison to accepted legacy methods were were within 35% of estimated values. Conclusion: Modern data collection and reporting methods ease the process for estimation of fetal dose from interventional fluoroscopy exposures. Many aspects of the calculation can now be quantified rather than estimated, which should allow for a more accurate estimation of fetal dose.

60 APPLIED LIFE SCIENCES↗

Plant root trait measurements raw data, 1962-2018, Island of Puerto Rico

This data package is a compilation of studies and raw datasets on root traits including root biomass, root nitrogen and phosphorus concentrations organized by different root diameters, species, soil depth, and forest types in Puerto Rico. The attached zip file contains a Word document that describes metadata including the methods, the data sources and publications used in the synthesis, and information about the content of included CSV data files. Separate KMZ and csv files are attached with the collection locations.

54 ENVIRONMENTAL SCIENCES↗

Identification of Galaxy–Galaxy Strong Lens Candidates in the DECam Local Volume Exploration Survey Using Machine Learning

We perform a search for galaxy–galaxy strong lens systems using a convolutional neural network (CNN) applied to imaging data from the first public data release of the DECam Local Volume Exploration Survey, which contains ~520 million astronomical sources covering ~4000 deg 2 of the southern sky to a 5σ point–source depth of g = 24.3, r= 23.9, i = 23.3, and z = 22.8 mag. Following the methodology of similar searches using Dark Energy Camera data, we apply color and magnitude cuts to select a catalog of ~11 million extended astronomical sources. After scoring with our CNN, the highest-scoring 50,000 images were visually inspected and assigned a score on a scale from 0 (not a lens) to 3 (very probable lens). We present a list of 581 strong lens candidates, 562 of which are previously unreported. We categorize our candidates using their human-assigned scores, resulting in 55 Grade A candidates, 149 Grade B candidates, and 377 Grade C candidates. We additionally highlight eight potential quadruply lensed quasars from this sample. Due to the location of our search footprint in the northern Galactic cap (b > 10 deg) and southern celestial hemisphere (decl. < 0 deg), our candidate list has little overlap with other existing ground-based searches. Where our search footprint does overlap with other searches, we find a significant number of high-quality candidates that were previously unidentified, indicating a degree of orthogonality in our methodology. We report properties of our candidates including apparent magnitude and Einstein radius estimated from the image separation.

79 ASTRONOMY AND ASTROPHYSICS↗

Electrical Resistivity Correlation to Vadose Zone Sediment and Pore-Water Composition for the BC Cribs and Trenches Area

This technical report documents the results of geochemical and soil resistivity characterization of sediment obtained from four boreholes drilled in the BC Cribs and Trench area. Vadose zone sediment samples were obtained at a frequency of about every 2.5 ft from approximately 5 ft bgs to borehole total depth. In total, 505 grab samples and 39 six-inch long cores were obtained for characterization. The pore-water chemical composition data, laboratory-scale soil resistivity and other ancillary physical and hydrologic measurements and analyses described in this report are designed to provide a crucial link between direct measurements on sediments and the surface-based electrical-resistivity information obtained via field surveys. A second goal of the sediment characterization was to measure the total and water-leachable concentrations of key contaminants of concern as a function of depth and distance from the footprints of inactive disposal facilities. The total and water-leachable concentrations of key contaminants will be used to update contaminant distribution conceptual models and to provide more data for improving base-line risk predictions and remedial alternative selections. The ERC “ground truthing” exercise for the individual boreholes showed mixed results. In general, the high concentrations of dissolved salts in the pore waters of sediments from C5923, C5924 and C4191 produced a low resistivity “target” in the processed resistivity field surveys, and variability could be seen in the resistivity data that could relate to the variability in pore- water concentrations but the correlations (regression R2 were mediocre ranging from 0.2 to 0.7 at best; where perfect correlation is 1.0). The field-based geophysical data also seemed to suffer from a sort of vertigo, where looking down from the ground surface, the target (e.g., maximum pore-water salt concentration) depth was difficult to resolve. The best correlations between the field electrical resistivity surveys and borehole pore water data sets were obtained when focusing on areal extent of the salt plume. Lateral resolution of the geophysical field data is best conducted by comparing an aggregated set of geophysical data on all boreholes together. When assembling the pore-water data for all four boreholes in an aerial view, the field ERC data produce a reasonable aerial picture of where high salt plumes exist below the BC Cribs and Trenches area. Future work that relies on more laboratory soil resistivity and incorporation of other field data (spectral gamma, neutron moisture and soil density logs) and physical and hydraulic measurements on samples obtained from the boreholes will used develop a more detailed petrophysical model of the sediments below BC Cribs and Trenches. This more detailed model can be used as a more realistic “earth model” in the inversion process to better manipulate the raw field survey data. It is also recommended that one more borehole be drilled after a thorough vetting of the current data with geophysics experts and other Hanford stakeholder to optimize where to place the borehole, what electrical and other geophysical surveys should be conducted , where to take sediment samples and what parameters should be measured on the sediments to attempt one more “ground truthing” exercise.

54 ENVIRONMENTAL SCIENCES↗

Depth resolved luminescence from oriented ZnO nanowires.

We have utilized the limited penetration depth of x-rays to study the near-surface properties of vertically aligned ZnO nanowires. For an energy of 600 eV the penetration depth varies between 3 and 132 nm as the incidence angle changes from 2{sup o} to 33{sup o}. Thus, by obtaining optical luminescence spectra as a function of incidence angle, it is possible to probe the near-surface region with nanometer-scale resolution. We will present angle dependent optical luminescence data from oriented ZnO nanowires. By fitting the results to a simple model, we extract a depth for the surface defect regions of -14 nm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TRACER-Coastal Urban Boundary-Layer Interactions with Convection (TRACER-CUBIC) Field Campaign Report

To better understand the complicated web of processes governing convective cloud life cycle and aerosol-convection interactions, the U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) user facility supported deployment of a variety of advanced atmospheric measurement systems to the greater Houston, Texas, area from 1 October 2021 to 30 September 2022 as part of the Tracking Aerosol Convection Interactions Experiment (TRACER). Houston was selected as a study area because isolated convection and a variety of aerosol conditions are common in this region. This one-year ARM Mobile Facility (AMF) deployment featured a four-month intensive operational period (IOP) during summer 2022 (1 June–30 September). The ARM instrumentation was deployed at three sites along an east-west transect from La Porte, Texas to an ancillary site in a less-polluted rural region southwest of downtown Houston (Figure 1). At the La Porte Site, which is located near the Houston ship channel in an area that experiences significant pollution, the first ARM Mobile Facility (AMF1) was deployed. During the IOP, the ARM tethered balloon system (TBS) operated at the ancillary site. The second-generation C-Band Scanning ARM Precipitation Radar (CSAPR) operated near Pearland, Texas, roughly halfway between the Laporte and ancillary sites. As part of the TRACER- Coastal Urban Boundary-Layer Interactions with Convection (CUBIC) project, three boundary-layer profiling systems) were deployed along a north-south transect spanning from the University of Houston Coastal Center to the Aldine site north of downtown Houston (also blue dot in Figure 1) during the TRACER IOP. These systems included the National Oceanic and Atmospheric Administration (NOAA) National Severe Storms Laboratory CLAMPS2 (C2), which was deployed at the UHCC, the University of Wisconsin SPARC, which was deployed at the ARM CSAPR site near Pearland (orange diamond in middle of map in Figure 1), and the University of Oklahoma CLAMPS1 (C1), which was deployed at Aldine. These three systems have been successfully operated in various field campaigns, providing data sets that collectively offer new insights into atmospheric-boundary-layer (ABL) processes, sea-breeze (SB) circulations, and convection initiation (CI). For the TRACER IOP window, these systems ran continuously between 1 June and 26 September, 2022. Due to commitments to NOAA projects, the Doppler lidar at the UHCC site was not available until 24 June 2022. The CLAMPS and SPARC profiling systems are self-contained platforms that have benefited from several years of development and deployment. Instruments and data processing were maintained remotely, which made the 4-month deployment for the TRACER-CUBIC IOP period possible. The same basic instrument configuration comprises each system: a scanning Doppler wind lidar for flow characterization and passive profiler(s) for characterizing planetary-boundary-layer (PBL) thermodynamic properties. Each platform includes a Halo Streamline Doppler wind lidar, an Atmospheric Emitted Radiance Interferometer (AERI), and a surface meteorology station. CLAMPS1 and CLAMPS2 each also include a microwave radiometer (MWR, Figure 1d). The TRACER-CUBIC hypotheses included (i) Interactions of SB and urban circulations and how they affect the PBL structure in the Houston environment, causing spatially (horizontally and vertically) and temporally highly variable flow patterns, (ii) heat, moisture, and aerosol transport and mixing depend on these flow dynamics, and (iii) an improved understanding of the flow patterns and PBL structure are critical for investigating the processes leading to CI. To test these hypotheses, the project aimed at (i) characterizing SB circulations and their impacts on the diurnal evolution of the structure of the ABL, (ii) studying the evolution of Houston’s complex urban boundary layer, and (iii) identifying effects of urban-induced circulations on pre-convective environments. TRACER-CUBIC observations generally provide good coverage during the summer IOP. Initial screening of the data indicates a good number of cases with bay-breeze (BB) and/or SB signatures, local CI, and interesting boundary-layer features such as strong nocturnal low-level jets (LLJs, Table 1). The numbers listed in rows 3-5 in this table will be further updated as part of ongoing in-depth analyses and systematic identification of local circulations and CI events. More detailed information about the data availability and quality for each instrument is provided in the “readme” files that were submitted to the ARM Data Center along with each archived data sets. These “readme” files also provide instrument descriptions, information about the data collection and processing procedures, data formats, and any additional information relevant for further data analysis.

54 ENVIRONMENTAL SCIENCES↗

SU-E-T-16: A Comparison of Expected Dwell Times and Dose Variations for NAMD Patients Treated with An Episcleral Brachytherapy Device

Purpose: To evaluate the variations in dwell times and doses expected when using an episcleral brachytherapy device for treatment of neovascular agerelated macular degeneration (n-AMD) based on accurate imaging modalities Methods: Data from 40 eyes from 40 subjects with known n- AMD acquired through the Distance of Choroid Study (DOCS) conducted at Moorfields Eye Hospital was used to determine the target depth; the distance from the outer scleral surface of the eye, through the choroid, to the apex of the choroidal neovascularization (CNV). Each subject underwent, in triplicate, enhanced-depth Spectral Domain Optical Coherence Tomography (SD-OCT), Swept Source Optical Coherence Tomography, (SS-OCT) and Ocular Ultrasound (O-US). These data are the most comprehensive and accurate measurements of the dimensions of the CNV and adjacent layers of the eye for this cohort of patients. During treatment of n-AMD, patients receive a dose of 24Gy to the apex at the target depth. Using the percentage depth dose for a Sr-90 episcleral brachytherapy device, dwell times and doses to the apex were computed to determine the expected variations. Results: The mean target depth and the 95% confidence interval (CI) determined by combining O-US with SD-OCT were 1326 (956,1696)µm and with SS-OCT were 1332 (970,1693)µm. The calculated corresponding mean dwell times and 95% (CI) were 334 (223,445)s and 335 (226,445)s for SD-OCT and SS-OCT determined depths, respectively. The corresponding mean apex dose and 95% (CI) were 24 (35.9,18.0)Gy (SD-OCT) and 24 (35.6,18.1)Gy (SS-OCT). Conclusion: For episcleral brachytherapy treatment of n-AMD, using a patient population average target depth for treatment planning is inadequate, resulting in dose variations of a factor of approximately two over the 95% CI and larger variations for a nontrivial segment of the population. Each patient should have individualized imaging studies to determine the target depth for use in the dwell time calculation. Study was sponsored by Salutaris Medical Devices, Ltd., a subsidiary of Salutaris Medical Devices, Inc. Hamilton and Marsteller are founders of Salutaris Medical Devices, Inc. Drew, McGovern and Vitali are minor equity holders in Salutaris Medical Devices, Inc.

60 APPLIED LIFE SCIENCES↗

Cation- and lattice-site-selective magnetic depth profiles of ultrathin Fe 3 O 4 (001) films

A detailed understanding of ultrathin film surface properties is crucial for the proper interpretation of spectroscopic, catalytic, and spin-transport data. We present x-ray magnetic circular dichroism (XMCD) and x-ray resonant magnetic reflectivity (XRMR) measurements on ultrathin Fe 3 O 4 films to obtain magnetic depth profiles for the three resonant energies corresponding to the different cation species F e o c t 2 + , F e t e t 3 + , and F e o c t 3 + located on octahedral and tetrahedral sites of the inverse spinel structure of Fe 3 O 4 . By analyzing the XMCD spectrum of Fe 3 O 4 using multiplet calculations, the resonance energy of each cation species can be isolated. Performing XRMR on these three resonant energies yields magnetic depth profiles that each correspond to one specific cation species. The depth profiles of both kinds of Fe 3+ cations reveal a (3.9 ± 1.0) -Å -thick surface layer of enhanced magnetization, which is likely due to an excess of these ions at the expense of the F e o c t 2 + species in the surface region. The magnetically enhanced F e t e t 3 + layer is additionally shifted about 2.9 ± 0.4 Å farther from the surface than the F e o c t 3 + layer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

LARGE-SCALE FLUCTUATIONS IN THE He II Ly{alpha} FOREST AND He II REIONIZATION

We examine large-scale fluctuations in the He II Ly{alpha} forest transmission during and after He II reionization. We use a simple Monte Carlo model to distribute quasars throughout a large volume and compute the resulting radiation field along one-dimensional skewers. In agreement with previous studies, we find that the rarity of these sources induces order unity fluctuations in the mean optical depth after reionization, even when averaged over large segments ({approx}10-100Mpc across). We compare our models to existing data along five He II Ly{alpha} forest lines of sight spanning z {approx} 2-3.2. The large cosmic variance contained in our model plausibly explains many of the observed fluctuations at z {approx_lt} 2.5. But our models cannot accommodate the large fluctuations toward high optical depths on {approx}30Mpc scales observed at z {approx} 2.7-2.9, and the measured optical depths ({tau}{sub eff} {approx_gt} 4) at z>2.9 are difficult to explain with a smoothly evolving mean radiation field. In order to better understand these data, we construct a toy model of He II reionization, in which we assume that regions with the smallest radiation fields in a post-reionization universe (or farthest from strong ionizing sources) are completely dark during reionization. The observed fluctuations fit much more comfortably into this model, and we therefore argue that, according to present data, He II reionization does not complete until z {approx_lt} 2.9.

79 ASTRONOMY AND ASTROPHYSICS↗

Calibration of time-of-flight cameras for accurate intraoperative surface reconstruction

Purpose: In image-guided surgery (IGS) intraoperative image acquisition of tissue shape, motion, and morphology is one of the main challenges. Recently, time-of-flight (ToF) cameras have emerged as a new means for fast range image acquisition that can be used for multimodal registration of the patient anatomy during surgery. The major drawbacks of ToF cameras are systematic errors in the image acquisition technique that compromise the quality of the measured range images. In this paper, we propose a calibration concept that, for the first time, accounts for all known systematic errors affecting the quality of ToF range images. Laboratory and in vitro experiments assess its performance in the context of IGS.Methods: For calibration the camera-related error sources depending on the sensor, the sensor temperature and the set integration time are corrected first, followed by the scene-specific errors, which are modeled as function of the measured distance, the amplitude and the radial distance to the principal point of the camera. Accounting for the high accuracy demands in IGS, we use a custom-made calibration device to provide reference distance data, the cameras are calibrated too. To evaluate the mitigation of the error, the remaining residual error after ToF depth calibration was compared with that arising from using the manufacturer routines for several state-of-the-art ToF cameras. The accuracy of reconstructed ToF surfaces was investigated after multimodal registration with computed tomography (CT) data of liver models by assessment of the target registration error (TRE) of markers introduced in the livers.Results: For the inspected distance range of up to 2 m, our calibration approach yielded a mean residual error to reference data ranging from 1.5 ± 4.3 mm for the best camera to 7.2 ± 11.0 mm. When compared to the data obtained from the manufacturer routines, the residual error was reduced by at least 78% from worst calibration result to most accurate manufacturer data. After registration of the CT data with the ToF data, the mean TRE ranged from 3.7 ± 2.1 mm for point-based and 5.7 ± 1.9 mm for surface-based registration for the best camera to 6.2 ± 3.4 and 11.1 ± 2.8 mm, respectively. Compared to data provided by the manufacturer, the mean TRE decreased by 8%–60% for point-based and by 18%–74% for surface-based registration.Conclusions: Using the proposed calibration approach improved the measurement accuracy of all investigated ToF cameras. Although evaluated in the context of intraoperative image acquisition, the proposed calibration procedure can easily be applied to other medical applications using ToF cameras, such as patient positioning or respiratory motion tracking in radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗