Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

FLUX AND PHOTON SPECTRAL INDEX DISTRIBUTIONS OF FERMI-LAT BLAZARS AND CONTRIBUTION TO THE EXTRAGALACTIC GAMMA-RAY BACKGROUND

We present a determination of the distributions of the photon spectral index and gamma-ray flux-the so-called log N-log S relation-for the 352 blazars detected with a greater than approximately 7{sigma} detection threshold and located above {+-}20 Degree-Sign Galactic latitude by the Large Area Telescope of the Fermi Gamma-ray Space Telescope in its first year catalog. Because the flux detection threshold depends on the photon index, the observed raw distributions do not provide the true log N-log S counts or the true distribution of the photon index. We use the non-parametric methods developed by Efron and Petrosian to reconstruct the intrinsic distributions from the observed ones which account for the data truncations introduced by observational bias and includes the effects of the possible correlation between the two variables. We demonstrate the robustness of our procedures using a simulated data set of blazars and then apply these to the real data and find that for the population as a whole the intrinsic flux distribution can be represented by a broken power law with high and low indices of -2.37 {+-} 0.13 and -1.70 {+-} 0.26, respectively, and the intrinsic photon index distribution can be represented by a Gaussian with mean of 2.41 {+-} 0.13 and width of 0.25 {+-} 0.03. We also find the intrinsic distributions for the sub-populations of BL Lac and flat spectrum radio quasar type blazars separately. We then calculate the contribution of Fermi blazars to the diffuse extragalactic gamma-ray background radiation. Under the assumption that the flux distribution of blazars continues to arbitrarily low fluxes, we calculate the best-fit contribution of all blazars to the total extragalactic gamma-ray output to be 60%, with a large uncertainty.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigation of magnetic nanoparticles for the rapid extraction and assay of alpha-emitting radionuclides from urine: Demonstration of a novel radiobioassay method

In the event of an accidental or intentional release of radionuclides into a populated area, three things must occur in a timely manner: food and drinking water supplies must be determined to be safe to eat / drink, civilians and/or military personnel must be surveyed to ensure that they do not have external contamination, and they must be screened to ensure that significant ingestion or inhalation of radionuclides has not occurred (this paper is concerned with the latter). In the event of such a disaster, the volume of radiobioassays to be performed would be tremendous. If the event released significant levels of β- or α-emitting radionuclides, in vivo assays would be ineffective. Therefore, highly efficient and rapid analytical methods for radionuclide detection from submitted spot urine samples (≤ 50 mL) would be required. At present, the quantitative determination of α-emitting radionuclides from urine samples is highly labor intensive, and requires significant sample preparation and analysis time. Sorbent materials that provide effective collection and enable rapid assay could significantly streamline the radioanalytical process. We have demonstrated the use of paramagnetic nanoparticles as a novel class of extracting media for four α-emitting radionuclides of concern (Po, Ra, Am, and U) from chemically unmodified and pH 2 human urine. Herein the initial experimental sorption results are presented along with a novel method that utilizes paramagnetic nanoparticles for the extraction of radionuclides from unmodified human urine followed by the magnetic field-induced collection of the particles for subsequent α-counting-source preparation. Additionally, we construct a versatile human dose model that determines the detector count times required to estimate internal human dose at specific protective action thresholds. The model provides a means to assess a method’s detection capabilities and use fundamental health physics parameters and actual experimental data as core variables. The modeling shows that with effective sorbent materials, rapid screening for internalized α-emitters is possible from a 50 mL spot urine sample volume collected within one week of exposure/intake.

59 BASIC BIOLOGICAL SCIENCES↗

Physical properties of Ce3-xTe4 below room temperature

The physical properties of polycrystalline Ce{sub 3-x}Te{sub 4} were investigated by measurements of the thermoelectric properties, Hall coefficient, heat capacity, and magnetization. The fully filled, metallic x = 0 compound displays a soft ferromagnetic transition near 4 K, and analysis of the corresponding heat capacity anomaly suggests a doublet ground state for Ce{sup 3+}. The transition is suppressed to below 2 K in the insulating x = 0.33 composition, revealing that magnetic order in Ce{sub 3-x}Te{sub 4} is driven by a Ruderman-Kittel-Kasuya-Yosida (RKKY)-type interaction. The thermoelectric properties trend with composition as expected from simple electron counting, and the transport properties in Ce{sub 3}Te{sub 4} are observed to be similar to those in La{sub 3}Te{sub 4}. Trends in the low-temperature thermal conductivity data reveal that the phonons are efficiently scattered by electrons, while all compositions examined have a lattice thermal conductivity near 1.2 W/m K{sup -1} at 200 K.

36 MATERIALS SCIENCE↗

Effect of Measurement vs. Counting Errors on Parameters' Covariance in Neutron Tomography Analysis

We present here a method that estimates the relative effect of the counting uncertainty and of the instrument uncertainty on that of the parameters in a parametric model for neutron time of flight. The final result, obtained independently of calculation of the parameter values from measured data, presents explicitly the ratio of the two uncertainties in terms of the choice, settings, and placement of the detector and the oscilloscope. Consequently, the method can serve as a tool in planning a measurement setup.

fusion↗

Optimal Pulse Processing, Pile-Up Decomposition, and Applications of Silicon Drift Detectors at LCLS

Silicon drift detectors (SDDs) revolutionized spectroscopy in fields as diverse as geology and dentistry. For a subset of experiments at ultrafast, X-ray free-electron lasers (FELs), SDDs can make substantial contributions. Often the unknown spectrum is interesting, carrying science data, or the background measurement is useful to identify unexpected signals. Many measurements involve only several discrete photon energies known a priori, allowing single-event decomposition of pile-up and spectroscopic photon counting. We designed a pulse function and demonstrated that the signal amplitude (i.e., proportional to the detected energy and obtained from fitting with the pulse function), rise time, and pulse height are interrelated, and at short peaking times, the pulse height and pulse area are not optimal estimators for detected energy; instead, the signal amplitude and rise time are obtained for each pulse by fitting, thus removing the need for pulse shaping. By avoiding pulse shaping, rise times of tens of nanoseconds resulted in reduced pulse pile-up and allowed decomposition of remaining pulse pile-up at photon separation times down to hundreds of nanoseconds while yielding time-of-arrival information with the precision of 10 ns. Waveform fitting yields simultaneously high energy resolution and high counting rates (two orders of magnitude higher than current digital pulse processors). At pulsed sources or high photon rates, photon pile-up still occurs. We showed that pile-up spectrum fitting is relatively simple and preferable to pile-up spectrum deconvolution. We then developed a photon pile-up statistical model for constant intensity sources, extended it to variable intensity sources (typical for FELs), and used it to fit a complex pileup spectrum. We subsequently developed a Bayesian pile-up decomposition method that allows decomposing pile-up of single events with up to six photons from six monochromatic lines with 99% accuracy. The usefulness of SDDs will continue into the X-ray FEL era of science. Their successors, the ePixS hybrid pixel detectors, already offer hundreds of pixels, each with a similar performance to an SDD, in a compact, robust and affordable package.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling sequential context effects in diagnostic interpretation of screening mammograms

Prior research has shown that physicians’ medical decisions can be influenced by sequential context, particularly in cases where successive stimuli exhibit similar characteristics when analyzing medical images. This type of systematic error is known to psychophysicists as sequential context effect as it indicates that judgments are influenced by features of and decisions about the preceding case in the sequence of examined cases, rather than being based solely on the peculiarities unique to the present case. We determine if radiologists experience some form of context bias, using screening mammography as the use case. To this end, we explore correlations between previous perceptual behavior and diagnostic decisions and current decisions. We hypothesize that a radiologist’s visual search pattern and diagnostic decisions in previous cases are predictive of the radiologist’s current diagnostic decisions. To test our hypothesis, we tasked 10 radiologists of varied experience to conduct blind reviews of 100 four-view screening mammograms. Eye-tracking data and diagnostic decisions were collected from each radiologist under conditions mimicking clinical practice. Perceptual behavior was quantified using the fractal dimension of gaze scanpath, which was computed using the Minkowski–Bouligand box-counting method. To test the effect of previous behavior and decisions, we conducted a multifactor fixed-effects ANOVA. Further, to examine the predictive value of previous perceptual behavior and decisions, we trained and evaluated a predictive model for radiologists’ current diagnostic decisions. ANOVA tests showed that previous visual behavior, characterized by fractal analysis, previous diagnostic decisions, and image characteristics of previous cases are significant predictors of current diagnostic decisions. Additionally, predictive modeling of diagnostic decisions showed an overall improvement in prediction error when the model is trained on additional information about previous perceptual behavior and diagnostic decisions.

60 APPLIED LIFE SCIENCES↗

becquerel (bq) v0.4.0

Becquerel is a Python package for analyzing nuclear spectroscopic measurements. The core functionalities are reading and writing different spectrum file types, fitting spectral features, rebinning spectrum counts to different bin edges, performing detector calibrations and interpreting measurement results. It also includes tools for visualizing radiation spectra and fits of different spectral features, as well as convenient access to tabulated nuclear data both from remote servers and local caches. It relies heavily on the standard scientific Python stack of numpy, scipy, matplotlib, pandas, and numba. It is intended to be general-purpose enough that it can be useful to anyone from an undergraduate taking a laboratory course to the advanced

Bandstra, Mark↗

becquerel (bq) v0.7.0

Becquerel is a Python package for analyzing nuclear spectroscopic measurements. The core functionalities are reading and writing different spectrum file types, fitting spectral features, rebinning spectrum counts to different bin edges, performing detector calibrations and interpreting measurement results. It also includes tools for visualizing radiation spectra and fits of different spectral features, as well as convenient access to tabulated nuclear data both from remote servers and local caches. It relies heavily on the standard scientific Python stack of numpy, scipy, matplotlib, pandas, and numba. It is intended to be general-purpose enough that it can be useful to anyone from an undergraduate taking a laboratory course to the advanced researcher.

Bandstra, Mark [Lawrence Berkeley National Laborat↗

Complex Disorder in Type-I Clathrates: Synthesis and Structural Characterization of A8GaxSn46−x (A = Rb, Cs; 6.9 < x < 7.5)

Exploratory studies in the systems Rb–Ga–Sn and Cs–Ga–Sn yielded the cubic type-I clathrates with refined compositions Rb8GaxSn46−x and Cs8GaxSn46−x (6.9 < x < 7.5). Nearly single-phase materials with good crystallinity were obtained from stoichiometric reactions of the elements. The structures were characterized by means of single-crystal X-ray diffraction methods. Both Rb8GaxSn46−x and Cs8GaxSn46−x represents cases, where a Group 13 element randomly substitutes a Group 14 element in the structure. The extent of Ga/Sn mixing is apparently governed by the drive of the system to achieve an optimal valence electron count, and hence, Rb8GaxSn46−x and Cs8GaxSn46−x (x ≈ 8) can be regarded as Zintl phases. This notion is supported by structure refinements on a multitude of single-crystal X-ray diffraction data, which also confirm that both types of cages in the cubic type-I structure are fully occupied by Rb and Cs atoms. The open-framework, comprised of 46 nodes per formula unit, adapts to the incorporation of nearly eight Ga atoms within the matrix of Sn, whereby small, short-range distortions result. The exact nature of these effects is still unclear, as so far, the structural variations could only be modeled as both positional and occupational disorder at one of three framework sites. Since vacancies in the structures of the binary type-I clathrates A8Sn46−x☐x (A = Rb, Cs; ☐ = missing Sn atom) are also known to cause local distortions, the latter were also synthesized with the same protocols used for the synthesis of A8GaxSn46−x and structurally re-analyzed. The results from the latter studies confirm that homogeneity issues abound, and that the final structures/compositions are an intricate function of the experimental conditions.

36 MATERIALS SCIENCE↗

Flux and Photon Spectral Index Distributions of Fermi-LAT Blazars and Contribution to the Extragalactic Gamma-ray Background

We present a determination of the distributions of gamma-ray flux - the so called LogN-LogS relation - and photon spectral index for the 352 blazars detected with a greater than approximately seven sigma detection threshold and located above {+-} 20{sup o} Galactic latitude by the Large Area Telescope of the Fermi Gamma-ray Space Telescope in its first year catalog. Because the flux detection threshold depends on the photon index, the observed raw distributions do not provide the true LogN-LogS counts or the true distribution of the photon index. We use the non-parametric methods developed by Efron and Petrosian to reconstruct the intrinsic distributions from the observed ones which account for the data truncations introduced by observational bias and includes the effects of the possible correlation among the two variables. We demonstrate the robustness of our procedures using a simulated data set of blazars and then apply these to the real data and find that for the population as a whole the intrinsic flux distribution can be represented by a broken power law of slopes -2.37 {+-} 0.13 and -1.70 {+-} 0.26, and the intrinsic photon index distribution can be represented by a Gaussian with mean 2.41 {+-} 0.13 and 1{sigma} width of 0.25 {+-} 0.03. We also find the intrinsic distributions for the sub-populations of BL Lac and FSRQs type blazars separately. We then calculate the contribution of blazars to the diffuse cosmic gamma-ray background radiation to be 28% {+-} 19%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development, Testing and Validation of a Waste Assay System for the Measurement and Characterisation of Active Spent Fuel Element Debris From UK Magnox Reactors - 12533

This paper describes the development, testing and validation of a waste measurement instrument for characterising active remote handled radioactive waste arising from the operation of Magnox reactors in the United Kingdom. Following operation in UK Magnox gas cooled reactors and a subsequent period of cooling, parts of the magnesium-aluminium alloy cladding were removed from spent fuel and the uranium fuel rods with the remaining cladding were removed to Sellafield for treatment. The resultant Magnox based spent fuel element debris (FED), which constitutes active intermediate level waste (ILW) has been stored in concrete vaults at the reactor sites. As part of the decommissioning of the FED vaults the FED must be removed, measured and characterised and placed in intermediate storage containers. The present system was developed for use at the Trawsfynydd nuclear power station (NPS), which is in the decommissioning phase, but the approach is potentially applicable to FED characterisation at all of the Magnox reactors. The measurement system consists of a heavily shielded and collimated high purity Germanium (HPGe) detector with electromechanical cooling and a high count-rate preamplifier and digital multichannel pulse height analyser. The HPGe based detector system is controlled by a software code, which stores the measurement result and allows a comprehensive analysis of the measured FED data. Fuel element debris is removed from the vault and placed on a tray to a uniform depth of typically 10 cm for measurement. The tray is positioned approximately 1.2 meters above the detector which views the FED through a tungsten collimator with an inverted pyramid shape. At other Magnox sites the positions may be reversed with the shielded and collimated HPGe detector located above the tray on which the FED is measured. A comprehensive Monte Carlo modelling and analysis of the measurement process has been performed in order to optimise the measurement geometry and eliminate interferences from radioactive sources and FED in the immediate vicinity of the measurement position. The detector system has been calibrated and high activity radioactive sources of Cs-137, Co-60 and Na-22 have been used to validate the measurement process. The data acquisition and analysis software code has been tested and validated in keeping with the software quality assurance requirements of both ISO:9001-2008 - TICK-IT in the UK and NQA-1. The measurement and analysis system has been comprehensively tested with high activity sources, is flexible and may be applicable to a wide range of remote handled radioactive waste measurement applications. It is due to be installed at Trawsfynydd NPS later this year. This paper describes the Waste Tray Assay System (WTAS) that has been developed for the measurement of Magnox FED waste. The WTAS has been tested with a range of radioactive sources and its operation has been simulated with benchmarked MCNP Monte Carlo calculations. The measurement software has been validated as has the operation of the system for a range of strong radioactive sources. A system based on the design is due for installation and operation in 2012. The system has application to the measurement of Magnox Fuel Element Debris (FED) waste at other Magnox reactor sites. The major design objective of the WTAS that has been achieved is the ability of the assay system to determine the content of Cs-137, and in turn to enable the fissile burden to be assessed using a radionuclide fingerprint, in the presence of higher and highly variable quantities of Co-60, typically from nimonic springs. The approach can be used in other Magnox FED waste configurations where the detector is located above the FED waste sorting tray and where the collimation is fixed below the detector and at a distance above the tray. In this case, which has also been investigated, there are different shielding problems and mechanical support issues. The extensive use of MCNP Monte Carlo modelling to simulate the geometry of the sorting cell and the distribution of radioactive sources has helped to ensure that all of the detector shielding requirements are addressed and suitable Cs-137 and Co-60 discrimination can be achieved. The WTAS in its present form or in other configurations has relevance to the measurement of other active ILW and highly active RH waste. Examples include high activity RH LLW and RH TRU (Transuranic) waste as defined in the United States arising from both commercial nuclear and Department of Energy (DOE) operations. The analysis is able to analyse a range of radionuclides beyong those expected in the Magnox FED cases. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Octet baryon masses and sigma terms from an SU(3) chiral extrapolation

We analyze the consequences of the remarkable new results for octet baryon masses calculated in 2+1- avour lattice QCD using a low-order expansion about the SU(3) chiral limit. We demonstrate that, even though the simulation results are clearly beyond the power-counting regime, the description of the lattice results by a low-order expansion can be significantly improved by allowing the regularisation scale of the effective field theory to be determined by the lattice data itself. The model dependence of our analysis is demonstrated to be small compared with the present statistical precision. In addition to the extrapolation of the absolute values of the baryon masses, this analysis provides a method to solve the difficult problem of fine-tuning the strange-quark mass. We also report a determination of the sigma terms for all of the octet baryons, including an accurate value of the pion-nucleon sigma term and the first determination of the strangeness sigma term based on 2+1-flavour l

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A fixed mass method for the Kramers-Moyal expansion—Application to time series with outliers

Extraction of stochastic and deterministic components from empirical data—necessary for the reconstruction of the dynamics of the system—is discussed. We determine both components using the Kramers-Moyal expansion. In our earlier papers, we obtained large fluctuations in the magnitude of both terms for rare or extreme valued events in the data. Calculations for such events are burdened by an unsatisfactory quality of the statistics. In general, the method is sensitive to the binning procedure applied for the construction of histograms. Instead of the commonly used constant width of bins, we use here a constant number of counts for each bin. This approach—the fixed mass method—allows to include in the calculation events, which do not yield satisfactory statistics in the fixed bin width method. The method developed is general. To demonstrate its properties, here, we present the modified Kramers-Moyal expansion method and discuss its properties by the application of the fixed mass method to four representative heart rate variability recordings with different numbers of ectopic beats. These beats may be rare events as well as outlying, i.e., very small or very large heart cycle lengths. The properties of ectopic beats are important not only for medical diagnostic purposes but the occurrence of ectopic beats is a general example of the kind of variability that occurs in a signal with outliers. To show that the method is general, we also present results for two examples of data from very different areas of science: daily temperatures at a large European city and recordings of traffics on a highway. Using the fixed mass method, to assess the dynamics leading to the outlying events we studied the occurrence of higher order terms of the Kramers-Moyal expansion in the recordings. We found that the higher order terms of the Kramers-Moyal expansion are negligible for heart rate variability. This finding opens the possibility of the application of the Langevin equation to the whole range of empirical signals containing rare or outlying events. Note, however, that the higher order terms are non-negligible for the other data studied here and for it the Langevin equation is not applicable as a model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of a method for activity estimation in Sm-153 EDTMP imaging

Absolute activity evaluation is fundamental for internal radionuclide dosimetry when patient-specific therapy optimization is wanted. Often, quantification is attempted with 3D SPECT image based (IB) methods, but the true concentration values can be underestimated due to the partial volume effect (PVE). This is especially true when small diffuse lesions are present. In this paper, we describe a 3D region of interest (ROI) based quantification method (LS-ROI), which estimates the ROI concentration values directly from the projection data acquired in the tomographic scan once ROIs have been segmented on a CT and/or a SPECT image. The method, which has inherent PVE correction capabilities, was applied both on simulated and on real phantom data. Simulations reflected the case of a patient with bone metastases treated with {sup 153}Sm-EDTMP: Both the activity in the metastases and the total retention in the skeleton were evaluated. Thirty noisy data sets were produced in order to evaluate the accuracy and precision of the method. The effect of region segmentation errors on estimated concentrations was thoroughly investigated. Real data were acquired on a NEMA phantom, where a cylindrical central region (283 cm{sup 3}) simulated the bone and two spheres (10.3 and 25.5 cm{sup 3}) simulated the metastases. The results obtained with the LS-ROI method were compared with those of a conventional 3D IB method and those of a quantitative conjugate view approach derived from LS-ROI and applied to the anterior and posterior views acquired in the tomographic scan (LS-ROI anterior-posterior: LS-ROI-AP). Simulations showed that when the geometry of regions is known, the LS-ROI method recovered the simulated concentration values within 20%, while the IB method underestimated the concentration in high activity small lesions by as much as 49%. Segmentation errors, up to 44% of the true region volume, produced a higher variation in LS-ROI estimates than in IB ones; however, the overall bias of the LS-ROI estimates ({<=}25%) remained lower than that of IB estimates. In the case of the evaluation of the total retention in the skeleton, the LS-ROI method recovered the simulated value within 2%, while IB underestimated it up to 13%. In all the cases, the LS-ROI-AP method showed an accuracy comparable with that of the LS-ROI one, and a worse precision just because of the lower number of counts used in the analysis. However, a worsening of LS-ROI-AP performances was demonstrated in the case of strong overlap of regions: In this case, a bias of up to 40% was observed. The results obtained on real phantom data confirmed the simulation results: The IB method underestimated activity up to 47% in the smallest sphere, while the bias was reduced to 13% with LS-ROI and LS-ROI-AP estimates. The good quantification capabilities of the LS-ROI method can be useful for absolute activity quantification in the case of small active diffused lesions and constitute the basis for the development of an accurate patient-specific planning strategy in internal radionuclide treatments, provided there is a reliable segmentation of lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Estimating the mass variance in neutron multiplicity counting $-$ A comparison of approaches

In the standard practice of neutron multiplicity counting, the first three sampled factorial moments of the event triggered neutron count distribution are used to quantify the three main neutron source terms: the spontaneous fissile material effective mass, the relative (α,n) production and the induced fission source responsible for multiplication. This study compares three methods to quantify the statistical uncertainty of the estimated mass: the bootstrap method, propagation of variance through moments, and statistical analysis of cycle data method. Each of the three methods was implemented on a set of four different NMC measurements, held at the JRC-laboratory in Ispra, Italy, sampling four different Pu samples in a standard Plutonium Scrap Multiplicity Counter (PSMC) well counter.

74 ATOMIC AND MOLECULAR PHYSICS↗

Effects, determination, and correction of count rate nonlinearity in multi-channel analog electron detectors

Detector counting rate nonlinearity, though a known problem, is commonly ignored in the analysis of angle resolved photoemission spectroscopy where modern multichannel electron detection schemes using analog intensity scales are used. We focus on a nearly ubiquitous “inverse saturation” nonlinearity that makes the spectra falsely sharp and beautiful. These artificially enhanced spectra limit accurate quantitative analysis of the data, leading to mistaken spectral weights, Fermi energies, and peak widths. We present a method to rapidly detect and correct for this nonlinearity. This algorithm could be applicable for a wide range of nonlinear systems, beyond photoemission spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SDAT – Analysis of 131mXe with 133Xe Interference

The Spectral Deconvolution Analysis Tool (SDAT) software was developed at The University of Texas at Austin. SDAT utilizes a standard spectrum technique for the analysis of beta-gamma coincidence spectra. Testing was performed on the software to compare the standard spectrum analysis technique with a region of interest (ROI) analysis technique. Experimentally produced standard spectra and sample data were produced at the Nuclear Engineering Teaching Laboratory (NETL) TRIGA reactor. The results of the testing showed that the standard spectrum technique had lower errors than the ROI analysis technique for samples with low counting statistics. In contrast, the ROI analysis technique outperformed the standard spectrum technique in high counting statistics samples. It was also shown that the standard spectrum technique benefitted from a compression of the number of channels within the spectra.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

An efficient parallel sampling technique for Multivariate Poisson-Lognormal model: Analysis with two crash count datasets

Our study investigates the Multivariate Poisson-lognormal (MVPLN) model that jointly models crash frequency and severity accounting for correlations. The ordinary univariate count models analyze crashes of different severity level separately ignoring the correlations among severity levels. The MVPLN model is capable to incorporate the general correlation structure and takes account of the over dispersion in the data that leads to a superior data fitting. But, the traditional estimation approach for MVPLN model is computationally expensive, which often limits the use of MVPLN model in practice. In this work, a parallel sampling scheme is introduced to improve the original Markov Chain Monte Carlo (MCMC) estimation approach of the MVPLN model, which significantly reduces the model estimation time. Two MVPLN models are developed using the pedestrian vehicle crash data collected in New York City from 2002 to 2006, and the highway-injury data from Washington State (5-year data from 1990 to 1994) The Deviance Information Criteria (DIC) is used to evaluate the model fitting. The estimation results show that the MVPLN models provide a superior fit over univariate Poisson-lognormal (PLN), univariate Poisson, and Negative Binomial models. Moreover, the correlations among the latent effects of different severity levels are found significant in both datasets that justifies the importance of jointly modeling crash frequency and severity accounting for correlations.

97 MATHEMATICS AND COMPUTING↗