Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “corrected data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Encoding nonlinear and unsteady aerodynamics of limit cycle oscillations using nonlinear sparse Bayesian learning

This article investigates the applicability of a recently proposed, nonlinear sparse Bayesian learning (NSBL) algorithm to identify and estimate the complex aerodynamics of limit cycle oscillations. NSBL provides a semi-analytical framework for determining the data-optimal sparse model nested within a (potentially) over-parameterized model. This is particularly relevant to nonlinear dynamical systems where modelling approaches involve the use of physics-based and data-driven components. In such cases, the data-driven components, where analytical descriptions of the physical processes are not readily available, are often prone to overfitting, meaning that the empirical aspects of these models will often involve the calibration of an unnecessarily large number of parameters. While an overparameterized model may fit the observed data well, such models may be inadequate for making predictions in regimes that are different from those wherein the data were recorded. In view of this, it is desirable to not only calibrate the model parameters, but also identify the optimal compromise between data fit and model complexity. In this article, we exhibit the optimal model discovery for an aeroelastic system wherein the structural dynamics are well-known and described by a differential equation model, coupled with a semi-empirical aerodynamic model for laminar separation flutter, resulting in low-amplitude limit cycle oscillations (LCO). To illustrate the performance of the algorithm, in this article, we use synthetic data and demonstrate the ability of the algorithm to correctly rediscover the optimal model and model parameters, given a known data-generating model. The synthetic data are generated from a forward simulation of a known differential equation model with parameters selected so as to mimic the dynamics observed in wind-tunnel experiments. Subsequently, we demonstrate the performance of the algorithm for model selection using noisy LCO data from wind tunnel experiments. As there is no ground truth available for the experimental data case, we provide a comparison between NSBL and Bayesian model selection to validate the results, and demonstrate the use of NSBL as an efficient alternative to traditional methods.

97 MATHEMATICS AND COMPUTING↗

Low-overhead mechanism to detect address faults in ECC-protected memories

Embodiments are generally directed to a low-overhead mechanism to detect address faults in ECC-protected memories. An embodiment of an apparatus includes a memory array; an error correction code (ECC) encoder for the memory array to encode ECC values based on a data value and a respective address value for the data value; and an ECC decoder for the memory array to decode ECC values that are based on data values and respective addresses for the data values; wherein the apparatus is to detect and correct an error in an address value based on an ECC value, address value, and data value stored in the memory.

Kwon, Kon-Woo↗

Beam Normal Single Spin Asymmetry in Forward Angle Inelastic Electron-Proton Scattering using the Q-Weak Apparatus

The Q-weak experiment in Hall-C at the Thomas Jefferson National Accelerator Facility has made the first direct measurement of the weak charge of the proton through the precision measurement of the parity-violating asymmetry in elastic electron-proton scattering at low momentum transfer. There is also a parity conserving Beam Normal Single Spin Asymmetry or transverse asymmetry (B_n) on H_2 with a sin(phi)-like dependence due to two-photon exchange. If the size of elastic B_n is a few ppm, then a few percent residual transverse polarization in the beam, combined with small broken azimuthal symmetries in the detector, would require a few ppb correction to the Q-weak data. As part of a program of B_n background studies, we made the first measurement of B_n in the N-to-Delta(1232) transition using the Q-weak apparatus. The final transverse asymmetry, corrected for backgrounds and beam polarization, was found to be B_n = 42.82 ± 2.45 (stat) ± 16.07 (sys) ppm at beam energy E_beam = 1.155 GeV, scattering angle theta = 8.3 deg, and missing mass W = 1.2 GeV. B_n from electron-nucleon scattering is a unique tool to study the gamma^* Delta Delta form factors, and this measurement will help to improve the theoretical models on beam normal single spin asymmetry and thereby our understanding of the doubly virtual Compton scattering process. To help correct false asymmetries from beam noise, a beam modulation system was implemented to induce small position, angle, and energy changes at the target to characterize detector response to the beam jitter. Two air-core dipoles separated by ~10 m were pulsed at a time to produce position and angle changes at the target, for virtually any tune of the beamline. The beam energy was modulated using an SRF cavity. The hardware and associated control instrumentation will be described in this dissertation. Preliminary detector sensitivities were extracted which helped to reduce the width of the measured asymmetry. The beam modulation system has also proven valuable for tracking changes in the beamline optics, such as dispersion at the target.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beam dynamics corrections to measurements of the muon anomalous magnetic moment

The Muon $g-2$ experiment at Fermilab is making progress towards its physics goal of measuring the muon anomalous magnetic moment with the unprecedented precision of 140 parts per billion. In April 2021, the collaboration published the first measurement based on the first year of data taking. The second result is based on the second and third years of data taking combined. We discuss the corrections to the anomalous spin precession signal due to beam dynamics effects being used to determine the anomalous spin precession frequency for the second result.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Prospects for direct detection of dark matter in an effective theory approach

We perform the first comprehensive analysis of the prospects for direct detection of dark matter with future ton-scale detectors in the general 11-dimensional effective theory of isoscalar dark matter-nucleon interactions mediated by a heavy spin-1 or spin-0 particle. The theory includes 8 momentum and velocity dependent dark matter-nucleon interaction operators, besides the familiar spin-independent and spin-dependent operators. From a variegated sample of 27 benchmark points selected in the parameter space of the theory, we simulate independent sets of synthetic data for ton-scale Germanium and Xenon detectors. From the synthetic data, we then extract the marginal posterior probability density functions and the profile likelihoods of the model parameters. The associated Bayesian credible regions and frequentist confidence intervals allow us to assess the prospects for direct detection of dark matter at the 27 benchmark points. First, we analyze the data assuming the knowledge of the correct dark matter nucleon-interaction type, as it is commonly done for the familiar spin-independent and spin-dependent interactions. Then, we analyze the simulations extracting the dark matter-nucleon interaction type from the data directly, in contrast to standard analyses. This second approach requires an extensive exploration of the full 11-dimensional parameter space of the dark matter-nucleon effective theory. Interestingly, we identify 5 scenarios where the dark matter mass and the dark matter-nucleon interaction type can be reconstructed from the data simultaneously. We stress the importance of extracting the dark matter nucleon-interaction type from the data directly, discussing the main challenges found addressing this complex 11-dimensional problem.

79 ASTRONOMY AND ASTROPHYSICS↗

Prior-based artifact correction (PBAC) in computed tomography

Purpose: Image quality in computed tomography (CT) often suffers from artifacts which may reduce the diagnostic value of the image. In many cases, these artifacts result from missing or corrupt regions in the projection data, e.g., in the case of metal, truncation, and limited angle artifacts. The authors propose a generalized correction method for different kinds of artifacts resulting from missing or corrupt data by making use of available prior knowledge to perform data completion. Methods: The proposed prior-based artifact correction (PBAC) method requires prior knowledge in form of a planning CT of the same patient or in form of a CT scan of a different patient showing the same body region. In both cases, the prior image is registered to the patient image using a deformable transformation. The registered prior is forward projected and data completion of the patient projections is performed using smooth sinogram inpainting. The obtained projection data are used to reconstruct the corrected image. Results: The authors investigate metal and truncation artifacts in patient data sets acquired with a clinical CT and limited angle artifacts in an anthropomorphic head phantom data set acquired with a gantry-based flat detector CT device. In all cases, the corrected images obtained by PBAC are nearly artifact-free. Compared to conventional correction methods, PBAC achieves better artifact suppression while preserving the patient-specific anatomy at the same time. Further, the authors show that prominent anatomical details in the prior image seem to have only minor impact on the correction result. Conclusions: The results show that PBAC has the potential to effectively correct for metal, truncation, and limited angle artifacts if adequate prior data are available. Since the proposed method makes use of a generalized algorithm, PBAC may also be applicable to other artifacts resulting from missing or corrupt data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Constraints on parton distribution functions and extraction of the strong coupling constant from the inclusive jet cross section in pp collisions at $\sqrt{s} = 7$ $\,\text {TeV}$

The inclusive jet cross section for proton–proton collisions at a centre-of-mass energy of 7TeVwas measured by the CMS Collaboration at the LHC with data corresponding to an integrated luminosity of 5.0fb -1 . The measurement covers a phase space up to 2TeV in jet transverse momentum and 2.5 in absolute jet rapidity. The statistical precision of these data leads to stringent constraints on the parton distribution functions of the proton. The data provide important input for the gluon density at high fractions of the proton momentum and for the strong coupling constant at large energy scales. Using predictions from perturbative quantum chromodynamics at next-to-leading order, complemented with electroweak corrections, the constraining power of these data is investigated and the strong coupling constant at the Z boson mass M Z is determined to be α S (M Z )=0.1185±0.0019(exp) +0.0060 -0.0037 (theo), which is in agreement with the world average.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparison of Methods Used to Age Spring–Summer Chinook Salmon in Idaho: Validation and Simulated Effects on Estimated Age Composition

Abstract Validation of aging methods with known-age individuals is rarely done with wild fish. We used samples collected from carcasses of adult Chinook salmon Oncorhynchus tshawytscha that were tagged as juveniles to (1) compare accuracy and precision of ocean ages determined from scales and fin rays and (2) simulate the effects of aging errors on run reconstruction (assignment to migratory cohort) under two age composition scenarios. Scale age had an overall accuracy of 81.8% and was biased high (χ2 = 8.67; P = 0.014). Fin ray age had an overall accuracy of 98.6% and was unbiased (χ2 = 2.00; P = 0.34). Precision of fin ray readings was higher than that of scale readings (coefficient of variation = 2.1% versus 7.8%, respectively). Accuracy of fin ray ages was greater than that of scale ages (Z = 2.198; P = 0.03). For two age composition scenarios, age classification errors were greatest when using scales and least when using fin rays. Aging errors inflated the size of weak cohorts in simulated run reconstructions. We showed how this can cause large errors in estimates of smolt-to-adult return rate when run strength and age composition vary among years. The amount of error associated with scale aging then becomes problematic for tracking the status of both threatened and healthy salmon stocks. Data based on fin ray readings provided the most accurate, unbiased estimates of age structure. Correction for methodological bias is important if age data are to be used in rigorous analyses.

Copeland, Timothy↗

2016 Postclosure Groundwater Monitoring and Inspection Report, Central Nevada Test Area, Nevada, Subsurface Corrective Action Unit 443

This report presents the groundwater monitoring data collected by the U.S. Department of Energy (DOE) Office of Legacy Management (LM) from the Central Nevada Test Area (CNTA), Nevada, Site, Subsurface Corrective Action Unit (CAU) 443 in Nye County, Nevada (Figure 1). The site was the location of an underground nuclear test in 1968, which resulted in residual contamination at and near the detonation depth of approximately 3200 feet (ft) below ground surface (bgs) that requires long-term monitoring. Responsibility for the environmental restoration and long-term monitoring was transferred from the DOE, National Nuclear Security Administration, Nevada Field Office to LM on October 1, 2006. The environmental restoration and site closure process were completed in 2015 in accordance with the Federal Facility Agreement and Consent Order (State of Nevada et al. 1996) (as amended) (FFACO) and all applicable Nevada Division of Environmental Protection (NDEP) policies and regulations. The Closure Report, Central Nevada Test Area, Subsurface Corrective Action, Unit 443 (LMS/CNT/S12760) (DOE 2016a) (Closure Report) describes LM’s plan for the long-term postclosure monitoring of radioisotope concentrations and water elevations, inspecting the site and maintaining the institutional controls (ICs), evaluating and reporting data, and documenting the site’s records and data management processes (DOE 2016a).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nanoscale Cluster Detection in Massive Atom Probe Tomography Data

Recent technological advances in atom probe tomography (APT) have led to unprecedented data acquisition capabilities that routinely generate data sets containing hundreds of millions of atoms. Detecting nanoscale clusters of different atom types present in these enormous amounts of data and analyzing their spatial correlations with one another are fundamental to understanding the structural properties of the material from which the data is derived. Extant algorithms for nanoscale cluster detection do not scale to large data sets. Here, a scalable, CUDA-based implementation of an autocorrelation algorithm is presented. It isolates spatial correlations amongst atomic clusters present in massive APT data sets in linear time using a linear amount of storage. Correctness of the algorithm is demonstrated using large synthetically generated data with known spatial distributions. Benefits and limitations of using GPU-acceleration for autocorrelation-based APT data analyses are presented with supporting performance results on data sets with up to billions of atoms. To our knowledge, this is the first nanoscale cluster detection algorithm that scales to massive APT data sets and executes on commodity hardware.

Seal, Sudip K↗

Towards in-situ high precision local material velocity measurements in lattice materials under dynamic compression

The study of dynamic compression of materials requires high precision spatial and temporal resolution to infer the material state at any given time. In ultra-fast imaging experiments such as those performed at the Dynamic Compression Sector at the Advanced Photon Source, the current CCD frame rate is less than the X-ray pulse rate necessitating that 4 CCDs be used to image a single scintillator screen to obtain the same projection of transmitted or diffracted beam at time intervals synchronized with the X-ray beam. The use of multiple-camera setups is often employed for a variety of reasons including enhancing the temporal resolution through interleaving frames or increasing the number of viewpoints, for example. Physical corrections are made to have each CCD approximately viewing the same field of view, however we present corrections that can be made after the data collection to further refine and be able to compare movements and changes in the sample between independent CCDs. These software corrections enable higher precision and higher fidelity comparison of position changes due to sample deformation. Furthermore, we present a method to correct images (or frames) as a demonstration toward high fidelity displacement measurements in these types of ultra-fast multi-camera setup experiments.

36 MATERIALS SCIENCE↗

Update on the Iron Opacity Experiments on the NIF

Recent iron opacity experiments on the Sandia National Laboratories Z machine have reported up to factors of two discrepancies between theoretical and experimental results. Much effort has been invested in identifying experimental errors as well as revisiting opacity theories, but a resolution of the discrepancies has not been forthcoming. Here, we emphasize the discrepancies present a fundamental theoretical challenge. To help resolve this question, an experimental platform for opacity experiments is being developed at the National Ignition Facility (NIF). This platform will be able to replicate the experimental conditions of the Z experiments and also extend the measurements to other temperatures and densities. Experiments to date have demonstrated a satisfactory X-ray backlighting source and have achieved the appropriate plasma conditions in the opacity sample. Some initial iron data have been taken, but problems remain with backgrounds and with the spectrometer used to make the measurements.The path forward for correcting these problems is presented.We expect that data for comparing with the Z experiments will be available within a year.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Initial Calibration of Large Timing Arrays for the LHC

In preparation for HL-LHC operation a number of new detector systems are being constructed with timing precision on physics objects of <50 picoseconds. These time stamps will reduce the level of pileup induced backgrounds in this LHC phase where the number of interactions per crossing will reach of order 100-200. In the case of CMS, three new systems have initially to be corrected for the usual amplitude walk resulting from the effect of variations in signal size on leading edge timing. In these systems the resulting timing spread (ie walk) ranges from one to four nanoseconds. In the following note we advocate approaching this initial calibration for walk as a calculable correction given early calibration during commissioning -- rather than depending on special collider data to perform the calibration. We derive a simple analytic expression for the walk correction and confirm its effectiveness with lab data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A beam hardening and dispersion correction for x-ray dark-field radiography

Purpose: X-ray dark-field imaging promises information on the small angle scattering properties even of large samples. However, the dark-field image is correlated with the object’s attenuation and phase-shift if a polychromatic x-ray spectrum is used. A method to remove part of these correlations is proposed. Methods: The experimental setup for image acquisition was modeled in a wave-field simulation to quantify the dark-field signals originating solely from a material’s attenuation and phase-shift. A calibration matrix was simulated for ICRU46 breast tissue. Using the simulated data, a dark-field image of a human mastectomy sample was corrected for the finger print of attenuation- and phase-image. Results: Comparing the simulated, attenuation-based dark-field values to a phantom measurement, a good agreement was found. Applying the proposed method to mammographic dark-field data, a reduction of the dark-field background and anatomical noise was achieved. The contrast between microcalcifications and their surrounding background was increased. Conclusions: The authors show that the influence of and dispersion can be quantified by simulation and, thus, measured image data can be corrected. The simulation allows to determine the corresponding dark-field artifacts for a wide range of setup parameters, like tube-voltage and filtration. The application of the proposed method to mammographic dark-field data shows an increase in contrast compared to the original image, which might simplify a further image-based diagnosis.

60 APPLIED LIFE SCIENCES↗

BioXTAS RAW 2 : new developments for a free open-source program for small-angle scattering data reduction and analysis

BioXTAS RAW is a free open-source program for reduction, analysis and modelling of biological small-angle scattering data. Here, the new developments in RAW version 2 are described. These include improved data reduction using pyFAI ; updated automated Guinier fitting and D max finding algorithms; automated series ( e.g. size-exclusion chromatography coupled small-angle X-ray scattering or SEC-SAXS) buffer- and sample-region finding algorithms; linear and integral baseline correction for series; deconvolution of series data using regularized alternating least squares ( REGALS ); creation of electron-density reconstructions using electron density via solution scattering ( DENSS ); a comparison window showing residuals, ratios and statistical comparisons between profiles; and generation of PDF reports with summary plots and tables for all analysis. Furthermore, there is now a RAW API, which can be used without the graphical user interface (GUI), providing full access to all of the functionality found in the GUI. In addition to these new capabilities, RAW has undergone significant technical updates, such as adding Python 3 compatibility, and has entirely new documentation available both online and in the program.

97 MATHEMATICS AND COMPUTING↗

Chemometric Analysis of Gas Chromatography – Mass Spectrometry Data using Fast Retention Time Alignment via a Total Ion Current Shift Function

A critical comparison of methods for correcting severely retention time shifted gas chromatography-mass spectrometry (GC-MS) data is presented. The method reported herein is an adaptation to the Piecewise Alignment Algorithm to quickly align severely shifted one-dimensional (1D) total ion current (TIC) data, then applying these shifts to broadly align all mass channels throughout the separation, referred to as a TIC shift function (SF). The maximum shift varied from (-) 5 s in the beginning of the chromatographic separation to (+) 20 s toward the end of the separation, equivalent to a maximum shift of over 5 peak widths. Implementing the TIC shift function (TIC SF) prior to Fisher Ratio (F-Ratio) feature selection and then principal component analysis (PCA) was found to be a viable approach to classify complex chromatograms, that in this study were obtained from GC-MS separations of three gasoline samples serving as complex test mixtures, referred to as types C, M and S. The reported alignment algorithm via the TIC SF approach corrects for large dynamic shifting in the data as well as subtle peak-to-peak shifts. The benefits of the overall TIC SF alignment and feature selection approach were quantified using the degree-of-class separation (DCS) metric of the PCA scores plots using the type C and M samples, since they were the most similar, and thus the most challenging samples to properly classify. The DCS values showed an increase from an initial value of essentially zero for the unaligned GC-TIC data to a value of 7.9 following alignment; however, the DCS was unchanged by feature selection using F-Ratios for the GC-TIC data. The full mass spectral data provided an increase to a final DCS of 13.7 after alignment and two-dimensional (2D) F-Ratio feature selection.

02 PETROLEUM↗

Uncertainty of Rotating Shadowband Irradiometers and Si-Pyranometers Including the Spectral Irradiance Error

Concentrating solar power projects require accurate direct normal irradiance (DNI) data including uncertainty specifications for plant layout and cost calculations. Ground measured data are necessary to obtain the required level of accuracy and are often obtained with Rotating Shadowband Irradiometers (RSI) that use photodiode pyranometers and correction functions to account for systematic effects. The uncertainty of Si-pyranometers has been investigated, but so far basically empirical studies were published or decisive uncertainty influences had to be estimated based on experience in analytical studies. One of the most crucial estimated influences is the spectral irradiance error because Si-photodiode-pyranometers only detect visible and color infrared radiation and have a spectral response that varies strongly within this wavelength interval. Furthermore, analytic studies did not discuss the role of correction functions and the uncertainty introduced by imperfect shading. In order to further improve the bankability of RSI and Si-pyranometer data, a detailed uncertainty analysis following the Guide to the Expression of Uncertainty in Measurement (GUM) has been carried out. The study defines a method for the derivation of the spectral error and spectral uncertainties and presents quantitative values of the spectral and overall uncertainties. Data from the PSA station in southern Spain was selected for the analysis. Average standard uncertainties for corrected 10 min data of 2% for global horizontal irradiance (GHI), and 2.9% for DNI (for GHI and DNI over 300 W/m2) were found for the 2012 yearly dataset when separate GHI and DHI calibration constants were used. Also the uncertainty in 1 min resolution was analyzed. The effect of correction functions is significant. The uncertainties found in this study are consistent with results of previous empirical studies.

14 SOLAR ENERGY↗

Dynamical polarization in the Coulomb breakup on loosely bound {sup 17}F.

Angular distributions of the Coulomb breakup of radioactive {sup 17}F were measured by impinging a 10 MeV/nucleon beam on {sup 208}Pb and on {sup 58}Ni to study the dynamic polarization effects. The breakup products, oxygen and a proton, were detected in coincidence. First-order perturbation theory significantly overpredicts the breakup cross section for the {sup 208}Pb target. Dynamical calculations with a dynamic polarization as the leading order correction were performed. The calculations reproduce the data for {sup 17}F on {sup 58}Ni but overpredict the breakup of {sup 17}F on {sup 208}Pb by a factor of two at forward angles.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗