Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “conclusions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Assessment of acute myocarditis by cardiac magnetic resonance imaging: Comparison of qualitative and quantitative analysis methods

Background: To compare cardiac magnetic resonance (CMR) qualitative and quantitative analysis methods for the noninvasive assessment of myocardial inflammation in patients with suspected acute myocarditis (AM). Methods: A total of 61 patients with suspected AM underwent coronary angiography and CMR. Qualitative analysis was performed applying Lake-Louise Criteria (LLC), followed by quantitative analysis based on the evaluation of edema ratio (ER) and global relative enhancement (RE). Diagnostic performance was assessed for each method by measuring the area under the curves (AUC) of the receiver operating characteristic analyses. The final diagnosis of AM was based on symptoms and signs suggestive of cardiac disease, evidence of myocardial injury as defined by electrocardiogram changes, elevated troponin I, exclusion of coronary artery disease by coronary angiography, and clinical and echocardiographic follow-up at 3 months after admission to the chest pain unit. Results: In all patients, coronary angiography did not show significant coronary artery stenosis. Troponin I levels and creatine kinase were higher in patients with AM compared to those without (both P < .001). There were no significant differences among LLC, T2-weighted short inversion time inversion recovery (STIR) sequences, early (EGE), and late (LGE) gadolinium-enhancement sequences for diagnosis of AM. The AUC for qualitative (T2-weighted STIR 0.92, EGE 0.87 and LGE 0.88) and quantitative (ER 0.89 and global RE 0.80) analyses were also similar. Conclusions: Qualitative and quantitative CMR analysis methods show similar diagnostic accuracy for the diagnosis of AM. These findings suggest that a simplified approach using a shortened CMR protocol including only T2-weighted STIR sequences might be useful to rule out AM in patients with acute coronary syndrome and normal coronary angiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Coronary risk equivalence of diabetes assessed by SPECT-MPI

Background: Several publications and guidelines designate diabetes mellitus (DM) as a coronary artery disease (CAD) risk equivalent. The aim of this investigation was to examine DM cardiac risk equivalence from the perspective of stress SPECT myocardial perfusion imaging (MPI). Methods and Results: We examined cardiovascular outcomes (cardiac death or nonfatal MI) of 17,499 patients referred for stress SPECT-MPI. Patients were stratified into four categories: non-DM without CAD, non-DM with CAD, DM without CAD, and DM with CAD, and normal or abnormal perfusion. Cardiac events occurred in 872 (5%), with event-free survival best among non-DM without CAD, worst in DM with CAD, and intermediate in DM without CAD, and non-DM with CAD. After multivariate adjustment, risk remained comparable between DM without CAD and non-DM with CAD [AHR 1.0 (95% CI 0.84–1.28), P =0.74]. Annualized event rates for normal subjects were 1.4% and 1.6% for non-DM with CAD and DM without CAD, respectively (P = 0.48) and 3.5% (P = 0.95) for both abnormal groups. After multivariate adjustment, outcomes were comparable within normal [AHR 1.4 (95% CI 0.98–1.96) P = 0.06] and abnormal [AHR 1.1 (95% CI 0.83–1.50) P = 0.49] MPI. Conclusions: Diabetic patients without CAD have comparable risk of cardiovascular events as non-diabetic patients with CAD after stratification by MPI results. These findings support diabetes as a CAD equivalent and suggest that MPI provides additional prognostic information in such patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Additional value of systolic wall thickening in myocardial stunning evaluated by stress-rest gated perfusion SPECT

Aim and patients: The aim of the present study is to evaluate the additional value of systolic wall thickening to myocardial perfusion in diagnosing myocardial stunning in patients with angiography proven coronary artery disease. We selected 91 ischemic patients (82 males; mean age 59.7 ± 10.3) with CAD documented by angiography. Ischemia was defined as a summed difference score ≥5. All patients underwent a 2-day gated perfusion SPECT protocol. The patients received a dose of 740 MBq of {sup 99m}Tc-tetrofosmin after stress and at rest. Treadmill maximal exercise tests were performed on all patients. Results: The post-stress LVEF was significantly lower than rest LVEF (48.1% ± 10.3% vs 50.3% ± 10.7%; P = .0001). The wall thickening summed difference score was 4.44 ± 4.13 (P = .0001). At a multivariate regression analysis, only WT-SDS as independent variable was significantly correlated with myocardial ischemia (SDS). We also divided patients according to SDS in those with mild (SDS < 8) and severe (SDS ≥ 8) ischemia. WT-SDS, but not ∆LVEF, was significantly different between groups. Conclusions: WT-SDS, more than the depression in the global function (∆LVEF) of the left ventricle, correlates with the degree of ischemia and better identifies, when present, the stunning phenomenon.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of attenuation correction for myocardial PET imaging using combined PET/MRI

Objective: To evaluate the frequency of artifacts in MR-based attenuation correction (AC) maps and their impact on the quantitative accuracy of PET-based flow and metabolism measurements in a cohort of consecutive heart failure patients undergoing combined PET/MR imaging. Methods: Myocardial viability studies were performed in 20 patients following a dual-tracer protocol involving the assessment of myocardial perfusion ({sup 13}N-NH{sub 3}: 813 ± 86 MBq) and metabolism ({sup 18}F-FDG: 335 ± 38 MBq). All acquisitions were performed using a fully-integrated PET/MR system, with standard DIXON-attenuation correction (DIXON-AC) mapping for each PET scan. All AC maps were examined for spatial misalignment with the emission data, total lung volume, susceptibility artifacts, and tissue inversion (TI). Misalignment and susceptibility artifacts were corrected using rigid co-registration and retrospective filling of the susceptibility-induced gaps, respectively. The effects of the AC artifacts were evaluated by relative difference measures and perceived changes in clinical interpretations. Results: Average respiratory misalignment of (7 ± 4) mm of the PET-emission data and the AC maps was observed in 18 (90%) patients. Substantial changes in the lung volumes of the AC maps were observed in the test–retest analysis (ratio: 1.0 ± 0.2, range: 0.8-1.4). Susceptibility artifacts were observed in 10 (50%) patients, while six (30%) patients had TI artifacts. Average differences of 14 ± 10% were observed for PET images reconstructed with the artifactual AC maps. The combined artifact effects caused false-positive findings in three (15%) patients. Conclusion: Standard DIXON-AC maps must be examined carefully for artifacts and misalignment effects prior to AC correction of cardiac PET/MRI studies in order to avoid misinterpretation of biased perfusion and metabolism readings from the PET data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

{sup 18}F-FDG PET/CT for the quantification of inflammation in large carotid artery plaques

Background: There is currently no consensus on the methodology for quantification of {sup 18}F-FDG uptake in inflammation in atherosclerosis. In this study, we explore different methods for quantification of {sup 18}F-FDG uptake in carotid atherosclerotic plaques and correlate the uptake values to histological assessments of inflammation. Methods and Results: Forty-four patients with atherosclerotic stenosis ≥70% of the internal carotid artery underwent {sup 18}F-FDG PET/CT. Maximum standardized uptake values (SUV{sub max}) from all plaque-containing slices were collected. SUV{sub max} for the single highest and the mean of multiple slices with and without blood background correction (by subtraction (cSUV) or by division (target-to-background ratio (TBR)) were calculated. Following endarterectomy 30 plaques were assessed histologically. The length of the plaques at CT was 6-32 mm. The {sup 18}F-FDG uptake in the plaques was 1.15-2.66 for uncorrected SUVs, 1.16-3.19 for TBRs, and 0.20-1.79 for cSUVs. There were significant correlations between the different uptake values (r = 0.57-0.99, P < 0.001). Methods with and without blood background correction showed similar, moderate correlations to the amount of inflammation assessed at histology (r = 0.44-0.59, P < 0.02). Conclusions: In large stenotic carotid plaques, {sup 18}F-FDG uptake reflects the inflammatory status as assessed at histology. Increasing number of PET slices or background correction did not change the correlation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volume-based glucose metabolic analysis of FDG PET/CT: The optimum threshold and conditions to suppress physiological myocardial uptake

Objective: FDG PET/CT plays a significant role in the diagnosis of inflammatory heart diseases and cardiac tumors. We attempted to determine the optimal FDG uptake threshold for volume-based analyses and to evaluate the relationship between the myocardial physiological uptake volume in FDG PET and several clinical factors. Methods: A total of 190 patients were retrospectively analyzed. The cardiac metabolic volume (CMV) was defined as a volume within the boundary determined by a threshold (SUVmean of blood pool × 1.5). Results: The SUVmean of the blood pool measured in the descending aorta (DA) (r = 0.86, intraclass correlation coefficient [ICC] = 0.93, P < 0.0001) and that in the left ventricle (LV) cavity (r = 0.87, ICC = 0.90, P < 0.0001) showed high inter-operator reproducibility. However, the SUVmean in the LV cavity showed a significant correlation with the CMV (P = 0.0002, r = 0.26). The CMV in the patients who fasted < 18 hours were significantly higher (49.7 ± 73.2 vs. 18.0 ± 53.8 mL, P = 0.0013) compared to the patients with > 18-hour fasting. The multivariate analysis demonstrated that only the fasting period > 18 hours was independently associated with CMV = 0. Conclusion: Our findings revealed that the DA is suitable to decide the threshold for the volume-based analysis. The fasting time was significantly associated with the cardiac FDG uptake.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early therapeutic effects of adaptive servo-ventilation on cardiac sympathetic nervous function in patients with heart failure evaluated using a combination of {sup 11}C-HED PET and {sup 123}I-MIBG SPECT

Rationale: Adaptive servo-ventilation (ASV), a novel respiratory support therapy for sleep disorders, may improve cardiac function in heart failure (HF). However, the reasons that ASV improves cardiac function have not been fully studied especially in sympathetic nervous function (SNF). The purpose of the present study was to investigate the effects of ASV therapy on cardiac SNF in patients with HF. Methods: We evaluated ASV therapeutic effects before and 6 months after ASV therapy in 9 HF patients [57.3 ± 17.3 years old, left ventricular ejection fraction (LVEF) 36.1 ± 16.7%]. We performed echocardiography, polysomnography, biomarkers, {sup 11}C-hydroxyephedrine (HED) PET as a presynaptic function marker and planar {sup 123}I-metaiodobenzylguanidine (MIBG) to evaluate washout rate. Results: ASV therapy reduced apnea-hypopnea index (AHI) and improved plasma brain natriuretic peptide (BNP) concentration. In {sup 123}I-MIBG imaging, the early heart/mediastinum (H/M) ratio increased after ASV therapy (2.19 ± 0.58 to 2.40 ± 0.67; P = 0.045). Washout rate did not change (23.8 ± 7.3% to 23.8 ± 8.8%; P = 0.122). Global {sup 11}C-HED retention index (RI) improved from 0.068 ± 0.033/s to 0.075 ± 0.034/s (P = 0.029). Conclusions: ASV reduced AHI and improved BNP. ASV might initially improve presynaptic cardiac sympathetic nervous function in HF patients after 6 months of treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Complete revascularization determined by myocardial perfusion imaging could improve the outcomes of patients with stable coronary artery disease, compared with incomplete revascularization and no revascularization

Objectives: To compare the outcomes among patients treated by complete coronary revascularization (CCR) or incomplete coronary revascularization (ICR) and no coronary revascularization (NCR) by myocardial perfusion imaging (MPI), as well as to evaluate the impact of severity of ischemia on patients with coronary artery disease (CAD) by different therapy strategies. Background: Using myocardial ischemia severity determined by MPI guiding treatment strategies for CAD patients still lacks strong clinical evidences. Methods: Consecutive patients (N = 286) underwent clinical stress-rest SPECT MPI and were retrospectively followed-up. For assessment of outcome of treatment, all patients were classified into three groups (CCR, ICR, and NCR), and further divided into two subgroups as mild ischemia (< 10% ischemic myocardium) and moderate-severe ischemia (≥ 10% ischemic myocardium). All-cause death was defined as the primary endpoint, and the composite of deaths, nonfatal myocardial infarction, and repeat revascularization (MACE) as the secondary endpoint. Results: Two-hundred eighty-six patients were followed-up for 46 ± 21 months. Thirty deaths and 65 MACEs were recorded. Patients treated by revascularization had significantly lower MACE (P < .001) but not mortality (P = .158) than patients treated by NCR. Outcomes of CCR related to mortality rate were greater than ICR and NCR (death: P = .019, MACE: P < .001). In patients with moderate-severe ischemia, CCR showed improved outcomes than ICR and NCR (death: P = .034; and MACE: P < .001). In patients with mild ischemia, the outcomes of CCR, ICR, and NCR had no significant difference (P > .05). Multivariate regression Cox analysis revealed that summed difference score [death: HR 1.09 (1.03, 1.15), P = .004] was an independent risk factor and CCR was an independent negative predictor [death: HR 0.31 (0.12, 0.81), P = .017; MACE: HR 0.30 (0.16, 0.57), P < .001]. Conclusions: Outcomes of patients treated by CCR were most likely more promising in comparison with treatment of ICR and NCR, especially when patients had over 10% ischemic myocardium.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relationship of left ventricular global longitudinal strain with cardiac autonomic denervation as assessed by {sup 123}I-mIBG scintigraphy in patients with heart failure with reduced ejection fraction submitted to cardiac resynchronization therapy

Background: Heart failure (HF) is associated with cardiac autonomic denervation (AD), which can be non-invasively assessed by {sup 123}I-metaiodobenzylguanidine ({sup 123}I-mIBG) scintigraphy and has prognostic implications. We aimed to study the relationship between myocardial contractility assessed by global longitudinal strain (GLS) and AD assessed by {sup 123}I-mIBG scintigraphy in advanced HF. Methods/Results: BETTER-HF is a prospective randomized clinical trial including HF patients (pts) submitted to cardiac resynchronization therapy (CRT) who are submitted to a clinical, echocardiographic, and scintigraphic assessment before and 6 months after CRT. 81 pts were included. An echocardiographic response (absolute increase in left ventricular ejection fraction ≥ 10%) was observed in 73.7% of pts. A higher baseline late heart-to-mediastinum ratio (HMR) was associated with a better echocardiographic response. There was a significant association between late HMR and GLS at baseline and 6 months. At baseline, GLS had an AUC of 0.715 for discrimination for a late HMR < 1.6. A GLS cut-off of − 9% maximized the likelihood of correctly classifying a pt as having severe AD (HMR < 1.6). Conclusion: Myocardial contractility as assessed by GLS is moderately correlated with AD as assessed by {sup 123}I-mIBG scintigraphy and has a good discrimination for the identification of severe cardiac denervation. GLS may allow for a more readily accessible estimation of the degree of AD in advanced HF pts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of two software systems for quantification of myocardial blood flow in patients with hypertrophic cardiomyopathy

Backgorund: Quantification of myocardial blood flow (MBF) by positron emission tomography (PET) is important for investigation of angina in hypertrophic cardiomyopathy (HCM). Several software programs exist for MBF quantification, but they have been mostly evaluated in patients (with normal cardiac geometry), referred for evaluation of coronary artery disease (CAD). Software performance has not been evaluated in HCM patients who frequently have hyperdynamic LV function, LV outflow tract (LVOT) obstruction, small LV cavity size, and variation in the degree/location of LV hypertrophy. Aim: We compared results of MBF obtained using PMod, which permits manual segmentation, to those obtained by FDA-approved QPET software which has an automated segmentation algorithm. Methods: {sup 13}N-ammonia PET perfusion data were acquired in list mode at rest and during pharmacologic vasodilation, in 76 HCM patients and 10 non-HCM patients referred for evaluation of CAD (CAD group.) Data were resampled to create static, ECG-gated and 36-frame-dynamic images. Myocardial flow reserve (MFR) and MBF (in ml/min/g) were calculated using QPET and PMod softwares. Results: All HCM patients had asymmetric septal hypertrophy, and 50% had evidence of LVOT obstruction, whereas non-HCM patients (CAD group) had normal wall thickness and ejection fraction. PMod yielded significantly higher values for global and regional stress-MBF and MFR than for QPET in HCM. Reasonably fair correlation was observed for global rest-MBF, stress-MBF, and MFR using these two softwares (rest-MBF: r = 0.78; stress-MBF: r = 0.66.; MFR: r = 0.7) in HCM patients. Agreement between global MBF and MFR values improved when HCM patients with high spillover fractions (> 0.65) were excluded from the analysis (rest-MBF: r = 0.84; stress-MBF: r = 0.72; MFR: r = 0.8.) Regionally, the highest agreement between PMod and QPET was observed in the LAD territory (rest-MBF: r = 0.82, Stress-MBF: r = 0.68) where spillover fraction was the lowest. Unlike HCM patients, the non-HCM patients (CAD group) demonstrated excellent agreement in MBF/MFR values, obtained by the two softwares, when patients with high spillover fractions were excluded (rest-MBF: r = 0.95; stress-MBF: r = 0.92; MFR: r = 0.95). Conclusions: Anatomic characteristics specific to HCM hearts contribute to lower correlations between MBF/MFR values obtained by PMod and QPET, compared with non-HCM patients. These differences indicate that PMod and QPET cannot be used interchangeably for MBF/MFR analyses in HCM patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of maximal Rubidium-82 activities for myocardial blood flow quantification between digital and conventional PET systems

Background: PET-based myocardial blood flow (MBF) quantification can be inaccurate when using high tracer activities. Our aim was to derive the maximal Rubidium-82 activity for MBF assessment using a new digital PET system and compare the results with conventional analog systems. Methods: 1.8 GBq Rubidium-82 was injected into the cardiac insert of an anthropomorphic torso phantom. Data were acquired for 10 min using an Ingenuity TF (Philips Healthcare), Discovery 690 (D690, GE Healthcare), and digital PET prototype system (Philips Healthcare). The dynamic ranges, defined as the maximal measured activity in the reconstructed images deviating < 10% from the true present activity, were determined in all scans. Results: The dynamic ranges were 312 MBq for Ingenuity TF, 650 MBq for D690, and 654 MBq for digital PET prototype. Conclusions: The maximal Rb-82 activity for MBF assessment using digital PET prototype is higher than that for its analog counterpart (Ingenuity TF), but seems comparable to the D690.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

{sup 18}F-FDG PET/CT-imaging of left ventricular assist device infection: a retrospective quantitative intrapatient analysis

Background: Despite the use of {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) positron emission tomography/computed tomography (PET/CT), diagnosis of a driveline infection in ventricular assist device (LVAD) recipients remains challenging. Our aim was to evaluate the potential of a baseline {sup 18}F-FDG PET/CT (prior to an infection) for the diagnosis of an LVAD-related infection. Methods: We retrospectively selected all LVAD recipients who had undergone two consecutive whole-body {sup 18}F-FDG PET/CT examinations between January 2010 and December 2016. PET/CT was analyzed qualitatively (uptake pattern) and semi-quantitatively (SUV{sub max} and ∆SUV{sub max}). SUV{sub max} was measured and compared in five distinctive volumes of interest along the LVAD driveline. An SUV{sub max} threshold was calculated. Final diagnosis was made by clinical examination, microbiological parameters, and molecular imaging. Results: Thirty patients were enrolled (mean age 54 ± 12 years; 26 male). Mean difference in SUV{sub max} for all five positions between the first and the second PET/CT along the driveline was significantly higher in patients with an LVAD-related infection (mean ∆SUV{sub max} = 4.38 ± 1.44) compared to those without a driveline infection (mean ∆SUV{sub max} = 0.03 ± 0.43), P < 0.05. Applying ROC analysis, an SUV{sub max} threshold of 3.88 resulted in a sensitivity and specificity of 100%, respectively. There were three distinctive uptake patterns in patients with a driveline infection. Conclusion: PET/CT diagnosis in the context of an LVAD-related infection can be improved by comparison to a baseline examination using a distinctive SUV{sub max} threshold.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Non-cardiac uptake of technetium-99m pyrophosphate in transthyretin cardiac amyloidosis

Background: Technetium-based bone scintigraphy is rapidly becoming the most common non-invasive imaging tool in the diagnosis of Transthyretin cardiac amyloidosis (ATTR). Skeletal muscle uptake has been described with technetium-99m-3,3-diphosphono-1,2-propanodicarboxylic acid (TcDPD), and may account for masking of bony uptake. We sought to investigate skeletal muscle uptake of technetium-99m-pyrophosphate (TcPYP) in patients with ATTR. Methods and Results: This was a retrospective analysis of 57 patients diagnosed with ATTR who underwent TcPYP scintigraphy. Cardiac uptake was assessed on whole-body planar imaging using a semiquantitative scale (grades 0 to 3) and on single-photon emission computed tomography (SPECT) with CT attenuation correction using total myocardial counts per voxel after a 3-hour incubation. Skeletal muscle (psoas and biceps), vertebral body, LV myocardium, and blood pool mean counts were calculated. In the cohort (age 78 ± 9 years, 77% male, and 30% hereditary ATTR), there was no visualized tracer uptake in skeletal muscle or soft tissue on qualitative SPECT assessment. Total and blood pool-corrected uptake in the muscle groups were significantly less than myocardium and bone (P < 0.001). Blood pool-corrected muscle uptake was not associated with semiquantitative grade 3 vs 2 uptake (psoas P = 0.66, biceps P = 0.13) or presence of hereditary ATTR (psoas P = 0.43, biceps P = 0.69). As bony uptake decreased, there was no corresponding increase in skeletal muscle uptake. Conclusions: In patients with ATTR cardiac amyloidosis, skeletal muscle uptake of TcPYP is minimal when assessed by qualitative and quantitative metrics, and is not significantly different in patients with grade 2 vs 3 semiquantitative uptake. The properties of this tracer may be different than TcDPD with respect to non-cardiac uptake.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Utilization of stress testing for low-risk patients with chest discomfort in the emergency department

Background: The management of patients presenting to an emergency department with chest discomfort at low-risk for acute coronary syndrome represents a common clinical challenge. Such patients are often triaged to chest pain units for monitoring and cardiac stress testing for further risk stratification. Methods: We conducted a retrospective study of 292 low-risk patients who presented to an emergency department with chest discomfort. We performed physician-adjudicated chart reviews of all patients with positive stress tests to assess downstream testing, subsequent coronary revascularization, and outcomes. Results: Of the 292 patients, 33 (11.3%) had stress tests positive for ischemia, and 12 (4.1%) underwent diagnostic cardiac catheterization. Of the 292 patients, 4 (1.4%) underwent coronary revascularization that may have resulted in a mortality benefit. Conclusion: These data suggest a very low yield of detecting clinically significant coronary disease with stress testing low-risk patients with chest discomfort in emergency department chest pain units.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of renin–angiotensin–aldosterone system polymorphisms on myocardial perfusion: Correlations with myocardial single photon emission computed tomography-derived parameters

Background: Renin–angiotensin–aldosterone system (RAAS) has an important role in atherosclerosis. We investigated the effects of six RAAS gene polymorphisms on myocardial perfusion. Methods and Results: We examined 810 patients with known or suspected coronary artery disease (CAD) using stress–rest myocardial single-photon emission computed tomography. Summed stress score (SSS), summed rest score (SRS), summed difference score (SDS), transient ischemic dilation (TID), and lung/heart ratio (LHR) were recorded. The following gene polymorphisms were investigated: angiotensin-converting enzyme (ACE) insertion/deletion (I/D), angiotensinogen (AGT) M235T and T174M, angiotensin II type 1 receptor (AT1R) A1166C, renin (REN) C5312T, and angiotensin II type 2 receptor (AT2R) C3123A. The heterozygotes or homozygotes on ACE D allele were 7.54 times more likely to have abnormal SSS, while the AGT (T174M) heterozygotes were 5.19 times more likely to have abnormal SSS. The homozygotes of ACE D had significantly higher values on TID and LHR, while the AGT (T174M) heterozygotes had higher values on TID. The AT1R heterozygotes had greater odds for having SSS ≥ 3. The patients carried AT1R homozygosity of C allele had significantly higher values on TID, while heterozygotes of AT1R had significantly higher values on LHR. Conclusions: Among the polymorphisms investigated, ACE D allele had the strongest association with abnormal myocardial perfusion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Focal mass-like cardiac uptake on oncologic FDG PET/CT: Real lesion or atypical pattern of physiologic uptake?

Background: Cardiac uptake on oncologic FDG PET/CT can be unpredictable. Focal or mass-like cardiac uptake not confined to normal pattern is a real challenge for interpretation due to great variability in physiologic uptake and rarity of either primary or metastatic cardiac neoplasms. Methods and Results: Eight patients with suspicious mass-like cardiac uptake on oncologic FDG PET/CT were retrospectively analyzed with correlation to cardiac workups including contrast CT, echocardiography, and repeat PET/CT. Four patients had real cardiac lesions or metastases. Focal uptake was benign and might represent papillary muscle in the other four. SUV{sub max} ratio between the cardiac focus and surrounding background cardiac uptake was statistically higher in the true-positive group than that in the false-positive group. In addition, the patients with true-positive cardiac uptake had more diffuse distant metastases compared to those with false-positive cardiac uptake. Conclusions: Focal suspicious cardiac uptake on oncology FDG PET/CT warranted further evaluation. SUV{sub max} ratio between the cardiac focus and surrounding background cardiac uptake and status of distant metastases might help to differentiate malignant from benign nature of the focal cardiac uptake on FDG PET/CT. Focal uptake of the right ventricle on oncologic FDG PET/CT is more likely suggestive of a neoplasm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Potential effects of low-dose average CT on cardiac implantable electronic devices

Background: Average CT has been shown to be more accurate than conventional helical CT in quantitation of the PET data. The risk of CT irradiation of a cardiac implantable electronic device (CIED) causing an adverse event is low and is generally outweighed by the clinical benefit of a medically indicated examination. However, irradiation of CIED over one breath cycle in cine CT scan for average CT could impose risks on a patient who is pacing dependent. The purpose of this study was to demonstrate that low-dose average CT can be safe for CIED. Methods: A Medtronic CIED of model Protecta VR was submerged in a saline bath for a series of 4-s cine CT scans on a GE CT scanner programmed to deliver a 2-cm-wide radiation at a dose rate of 0.9 to 41.2 mGy/s to the CIED. The number of over-sensings was recorded as the interference of radiation to the CIED. Results: Dose rates ≥ 1.9 mGy/s caused over-sensing. The higher the dose rate, the more over-sensings there were. The lowest dose rate of 0.9 mGy/s did not cause any over-sensing. Conclusions: Low-dose average CT at 0.9 mGy/s can be safe for a CIED patient who is pacing dependent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gated SPECT myocardial perfusion imaging with cadmium-zinc-telluride detectors allows real-time assessment of dobutamine-stress-induced wall motion abnormalities

Background: Left ventricular (LV) ejection fraction (EF) during high dobutamine stress (HD) by real-time gated-SPECT myocardial perfusion imaging (MPI) on a cadmium-zinc-telluride (CZT) gamma camera was validated versus cardiac magnetic resonance imaging (CMR). Methods and results: After injecting 99mTc-tetrofosmin (320 MBq) in 50 patients (mean age 64 +/− 11 years), EF at rest and post-stress as well as relevant changes in EF at HD (ΔEF ≥ 5%) were assessed. CZT and CMR rest EF values yielded an excellent correlation and agreement (r = 0.96; P < 0.001; Bland–Altman limits of agreement (BA): + 0 to 14.8%). HD EF acquisition was feasible using CZT and correlated better to HD CMR EF than did post-stress CZT EF (r = 0.85 vs 0.76, respectively, all P < 0.001). Agreement in ΔEF detection between HD CMR and immediate post-stress CZT (reflecting standard acquisition using conventional SPECT camera unable to scan during stress) was 45%, while this increased to 85% with real-time HD CZT scan. Conclusion: Real-time ultrafast dobutamine gated-SPECT MPI with a CZT device is feasible and provides accurate measurements of HD LV performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗