Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “commercialization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Data analytics and optimization of an ice-based energy storage system for commercial buildings

Ice-based thermal energy storage (TES) systems can shift peak cooling demand and reduce operational energy costs (with time-of-use rates) in commercial buildings. The accurate prediction of the cooling load, and the optimal control strategy for managing the charging and discharging of a TES system, are two critical elements to improving system performance and achieving energy cost savings. This study utilizes data-driven analytics and modeling to holistically understand the operation of an ice–based TES system in a shopping mall, calculating the system’s performance using actual measured data from installed meters and sensors. Results show that there is significant savings potential when the current operating strategy is improved by appropriately scheduling the operation of each piece of equipment of the TES system, as well as by determining the amount of charging and discharging for each day. A novel optimal control strategy, determined by an optimization algorithm of Sequential Quadratic Programming, was developed to minimize the TES system’s operating costs. Three heuristic strategies were also investigated for comparison with our proposed strategy, and the results demonstrate the superiority of our method to the heuristic strategies in terms of total energy cost savings. Specifically, the optimal strategy yields energy costs of up to 11.3% per day and 9.3% per month compared with current operational strategies. A one-day-ahead hourly load prediction was also developed using machine learning algorithms, which facilitates the adoption of the developed data analytics and optimization of the control strategy in a real TES system operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Adopting occupancy-based HVAC controls in commercial building energy codes: Analysis of cost-effectiveness and decarbonization potential

Recent research has shown the energy-saving potential of occupancy-based HVAC controls (OBCs) in commercial buildings. However, building energy codes have not fully adopted this technology. This study aims to evaluate the cost-effectiveness and decarbonization benefits of OBCs and provide guidance for integrating occupancy sensors into building energy code development. To this end, a parametric simulation using EnergyPlus and a nationwide cost-effectiveness analysis are carried out considering three building types and 40 representative cities in the U.S. Here, the findings reveal that the current cost-effectiveness performance of OBCs is limited due to the high cost of occupancy sensors. However, incorporating the societal cost of carbon factor in future energy and environmental policy could greatly enhance the actual cost-effectiveness performance. Besides, a reduction in the cost of occupancy sensors to approximately 60% of the current price level could also greatly shorten the discounted payback period of OBCs. Additionally, OBCs demonstrate significant potential in building decarbonization, with potential CO 2 emissions savings of more than 5.56 million metric tons across the three building types and 40 selected cities. Finally, policy implications are provided to guide the incorporation of occupancy-based HVAC controls in future energy codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Decarbonization of heat pump dual fuel systems using a practical model predictive control: Field demonstration in a small commercial building

In the transition from fossil fuel to electrified heating, a concerning trend is emerging in certain regions of the US. Owners of buildings with gas-based systems leave them in place after adding heat pumps (HPs). Existing control solutions for these hybrid (dual fuel) systems are rudimentary and fall short of realizing the full carbon reduction potential of these systems. Model predictive control (MPC) is often regarded as the benchmark for achieving optimal control in integrated systems. However, in the case of small-medium commercial buildings (SMCBs), the control and communication infrastructure required to facilitate the implementation of such advanced controls is often lacking. This paper presents a field implementation of easy-to-deploy MPC for a dual fuel heating system consisting of HPs and a gas-fired furnace (GF) for SMCBs. The control system is deployed on an open-source middleware platform and utilizes low-cost sensor devices to be used for real SMCBs without major retrofits. Here, we demonstrated this MPC in a real office building with 5 HPs and 1 GF for 2 months. The test results showed that MPC reduced 27% of cost while completely eliminating GF usage by shifting 23% of the thermal load from occupied-peak time to non-occupied-non-peak times.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Improving ethanol yields with deacetylated and two-stage pretreated corn stover and sugarcane bagasse by blending commercial xylose-fermenting and wild type Saccharomyces yeast

Corn stover and sugarcane bagasse are the most widely available agriculture processing biomass and could serve as feedstocks for production of biofuel. In this study, three different technologies are combined to develop a more efficient conversion process for each of these feedstocks. The three technologies are diluted alkaline deacetylation process, combined thermochemical and mechanical shear pretreatment, and fermentation using a combined inoculum of two commercial Saccharomyces yeast strains. The two yeast strains used were a non-GMO and GMO strain engineered for xylose fermentation. The final ethanol concentrations obtained were 35.7 g/L from deacetylated corn stover and 32.9 g/L from sugarcane bagasse. Blending the two yeast reduced residual xylose content from 1.24 g/L to 0.48g/L and increased ethanol production by 6.5% compared to solely using the C5/C6 yeast. In conclusion, the optimized yeast blend also lowered the amount of C5/C6 yeast required for inoculation by 80%.

09 BIOMASS FUELS↗

Regional difference and related cooling electricity savings of air pollutant affected natural ventilation in commercial buildings across the US

Maintaining indoor air pollutants under acceptable levels is significant to protect occupants from exposure to excessive air pollutants in natural ventilation. In this paper, using the representative air pollutant concentration data, we present the natural ventilation usability with associated cooling energy saving potentials in different location settings (urban and city center, suburban and rural) of the US under the influence of local weather conditions and major outdoor air pollutants, i.e. PM2.5, PM10 and ozone. It is found that the impacts of air pollutants on natural ventilation are usually higher in urban/suburban areas than rural areas (up to 25% difference) with the PM2.5 being the most significant outdoor air pollutant affecting natural ventilation usage. Furthermore, ozone could become increasingly influential on natural ventilation as moving from urban to suburban/rural areas. As to the cooling energy saving considering the impacts of outdoor air pollutants, natural ventilation is estimated to save approximately 10%–40% cooling energy (800–2600 kWh per small commercial building) annually in different location settings of investigated areas across the US. The following economic analysis demonstrates that these electricity savings lead to approximately 80–540 dollars annual savings of building operation cost per building. If the time of use rate is adopted, these cost savings could further increase by approximately 20% (Los Angeles) to more than 50% (Albuquerque) depending on different rate structures, which further demonstrates the potential of adopting natural ventilation as a sustainability measurement with benefits for building owners without compromising occupants health.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nature and spatial distribution of sulfur species in a sulfated barium-based commercial lean NOx trap catalyst

We report observations of the nature and spatial distribution of sulfur species on a sulfated Ba-based commercial lean NO{sub x} trap (LNT) catalyst. The monolithic catalyst was sulfated in a bench flow reactor during 60/4-s NO{sub x} storage/reduction cycling to achieve a total sulfur loading of 3.4 g L{sup -1} of catalyst. Washcoat composition, structure and sulfur distribution were analyzed with electron probe microanalysis, X-ray diffraction, Raman spectroscopy, X-ray photoelectron spectroscopy, and temperature-programmed reduction. The most significant washcoat elements of catalytic relevance were Pt, Pd, Rh, Ba, Ce, Zr, Mg, Al, and these were present mainly in four distinct domains; Mg/Al mixed oxide with Pt, Ce; Al oxide with Rh, Pd; Ce/Zr mixed oxide with Pt, Pd, Ba (high Ba content); Ce/Zr mixed oxide with Pt, Pd, Ba (lower Ba content). Sulfur was present in the form of sulfates that decreased in concentration along the LNT axis from front to back. Barium showed the highest sulfur affinity leading to a plug-like axial progression of its sulfation. The sulfation of AI, Mg/Al, and Ce/Zr oxides was less vigorous with a more axially dispersed and less penetrating front.

02 PETROLEUM↗

Effect of sulfur loading on the desulfation chemistry of a commercial lean NOx trap catalyst

We investigate the effects of initial sulfur loadings on the desulfation chemistry and the subsequent final activity of a commercial LNT catalyst. Identical total amounts of SO2 are applied to the samples, albeit with the frequency of desulfation varied. The results indicate that performance is better with less frequent desulfations. The greater the amount of sulfur deposited before desulfation, the more amount of SO2 evolution before H2S is observed during desulfation, which can be explained by two sequential reactions; initial conversion of sulfate to SO2, followed by the reduction of SO2 to H2S. After completing all sulfation/desulfation steps, the sample with only a single desulfation results in a fairly uniform sulfur distribution along the z-axis inside of the monolith. We expect that the results obtained in this study will provide useful information for optimizing regeneration strategies in vehicles that utilize the LNT technology.

Environmental Molecular Sciences Laboratory↗

Ammonia reactions with the stored oxygen in a commercial lean NO x trap catalyst

Ammonia is an important intermediate of the NO x reduction in a NO x storage and reduction catalyst (aka lean NO x trap). NH 3 formed under rich conditions in the reduced front part of the catalyst is transported by convection downstream to the unregenerated (still oxidized) zone of the catalyst, where it further reacts with the stored oxygen and NO x . In this paper, the kinetics and selectivity of NH 3 reactions with the stored oxygen are studied in detail with a commercial Ba-based NO x storage catalyst containing platinum group metals (PGM), Ba and Ce oxides. Furthermore, steady-state NH 3 decomposition, NH 3 oxidation by O 2 and NO, and N 2 O decomposition are examined in light-off experiments. Periodic lean/rich cycling is measured first with O 2 and NH 3 , and then with NO x + O 2 and NH 3 to discriminate between the NH 3 reactions with the stored oxygen and the stored NO x . The reaction of NH 3 with the stored O 2 is highly selective towards N 2 , however a certain amount of NO x and N 2 O is also formed. The formed NO x by-product is efficiently adsorbed on the NO x storage sites such that the NO x is not detected at the reactor outlet except at high temperatures. The stored NO x reacts with NH 3 feed in the next rich phase, contributing to the N 2 O formation. Water inhibits the reactions of NH 3 with the stored oxygen. On the contrary, the presence of CO 2 increases the NH 3 consumption. Furthermore, CO 2 is able to provide additional oxygen for NH 3 oxidation, forming –CO in analogy to the reverse water gas shift reaction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Energy-efficient carbon capture from industrial point sources via commercially available green solvent and hollow fiber membrane contactors

Solvent-based absorption systems have emerged in the carbon capture space due to their high absorption capacities, reusability, and favorable energy requirements. Using diethyl sebacate as a solvent for pre- and post-combustion carbon capture has advantages over other solvents, including high hydrophobicity, low viscosity, low vapor pressure, high CO 2 solubility, high CO 2 selectivity, and being commercially available in large quantities. Despite these advantageous properties, the use of diethyl sebacate as a solvent for post-combustion carbon capture has not been studied in detail. To examine the capability of diethyl sebacate, a scalable, energy-efficient, hollow fiber membrane (microporous polypropylene and polyvinylidene fluoride) contactor (HFMC)-based process with low-cost and high surface area is investigated. A purity of 95.3 % CO 2 with 46 % recovery in one absorption stage was achieved, with a permeate flux over one magnitude greater than using a deep eutectic solvent in the same system. Technoeconomic analysis determined a ∼ 0.8 GJ per ton of CO 2 at a processing cost of ∼$93 per ton of CO 2 . Results from this work underscore the potential for utilizing green solvents in HFMC-based separation processes for effective carbon capture and provide a pathway towards practical deployment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct air capture with bis-iminoguanidines: From discovery to commercialization

Here, research on direct air capture (DAC) of CO 2 at Oak Ridge National Laboratory (ORNL) over the past five years is highlighted, starting with the initial discovery, continuing with fundamental and applied research, and concluding with commercialization by teaming up with industry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cyclic oxidation behavior of selected commercial NiCr-alloys for engine exhaust valves in wet air environment between 800 and 950 °C

In this work, the impact of water vapor on the cyclic oxidation behavior of four commercial Ni-based superalloys (N80A, N90, R41 and H282) was investigated between 800 and 950°C. Oxidation- and volatilization-induced Cr loss accelerated the transition from protective and adherent oxide formation (Cr 2 O 3 ) to mixed oxides that significantly spalled at 950°C for H282 and R41. The accelerated oxidation, Cr depletion, and spallation susceptibility for R41 and to a lesser extent for H282 compared to N80A and N90 was related to the higher fraction of γ’, which led to increased Ti incorporation into the Cr 2 O 3 scale in the presence of water vapor.

36 MATERIALS SCIENCE↗

Superconducting properties of commercially available solders for low-field applications

Solders with superconducting transitions around 4K are useful in low magnetic field environments for AC current leads or in electrical and mechanical bonds. Accurate knowledge of these solders’ superconducting properties is essential for improving high precision experiments. We have measured the electrical resistance of five commercially-available eutectic or near-eutectic solders: 50%Sn-50%Pb, 60%Sn-40%Pb, 60%Sn-40%Pb-0.3%Sb, 52%In-48%Sn, and 96.5%Sn-3.5%Ag, down to 2.3K and in applied magnetic fields from 0 to 0.1 T . We report critical temperatures T c (B), 90%–10% transition widths ΔT c , and zero-temperature critical fields B c,0 . Our best candidate for low-loss AC current wiring in low fields is 50%Sn-50%Pb, which has a zero-field T c,0 = 7.1K (with ΔT c = 0.6 K), and remained high at T c (0.1 T) = 6.9K (ΔT c = 0.6K ). We also report, for the first time, T c and B c of 60%Sn-40%Pb-0.3%Sb and B c,0 of 96.5%Sn-3.5%Ag. Our T c,0 - 3.31K (ΔT c = 0.08K) for 96.5%Sn-3.5%Ag disagrees with a widely adopted value.

Hickman, C. [North Carolina State University, Rale↗

Assessing the impacts of future demand for saline groundwater on commercial deployment of CCS in the United States

This paper provides a preliminary assessment of the potential impact that future demand for groundwater might have on the commercial deployment of carbon dioxide capture and storage (CCS) technologies within the United States. A number of regions within the U.S. have populations, agriculture and industries that are particularly dependent upon groundwater. Moreover, some key freshwater aquifers are already over-utilized or depleted, and others are likely to be moving toward depletion as demand grows. The need to meet future water demands may lead some parts of the nation to consider supplementing existing supplies with lower quality groundwater resources, including brackish waters that are currently not considered sources of drinking water but which could provide supplemental water via desalination. In some areas, these same deep saline-filled geologic formations also represent possible candidate carbon dioxide (CO2) storage reservoirs. The analysis presented here suggests that future constraints on CCS deployment due to potential needs to supplement conventional water supplies by desalinating deeper and more brackish waters are likely to be necessary only in limited regions across the country, particularly in areas that are already experiencing water stress.

54 ENVIRONMENTAL SCIENCES↗

Investigating the durability of a direct methanol fuel cell equipped with commercial Platinum Group Metal-free cathodic electro-catalysts

For the first time a long-term (500 h) durability study in direct methanol fuel cells (DMFCs) is carried out on a Platinum Group Metal-free (PGM-free) cathodic electro-catalyst commercially available on market. The electro-catalyst is tested for 500 h at a fixed cell voltage (0.3 V), recording the polarization curves during the operation. A drastic decrease in performance is observed after the first 100 h (from 220 to 75 mA cm –2 ); afterwards, the decrease is flatter, passing from 75 to 25 mA cm –2 (at 500 h). The causes of this performance degradation are investigated by postmortem physicochemical analyzes, such as X-ray photoelectron spectroscopy (XPS), transmission electron microscopy (TEM) and scanning electron microscopy (SEM) with X-ray energy dispersive analysis (EDX). Finally, possible reasons of degradation are indicated to be PGM-free catalyst aggregation, carbon and nitrogen species decrease, Ruthenium dissolution and migration from the anode to the cathode, poisoning both membrane and cathode catalyst.

25 ENERGY STORAGE↗

Variability in Automated Responses of Commercial Buildings and Industrial Facilities to Dynamic Electricity Prices

Changes in the electricity consumption of commercial buildings and industrial facilities (C&I facilities) during Demand Response (DR) events are usually estimated using counterfactual baseline models. Model error makes it difficult to precisely quantify these changes in consumption and understand if C&I facilities exhibit event-to-event variability in their response to DR signals. This paper seeks to understand baseline model error and DR variability in C&I facilities facing dynamic electricity prices. Using a regression-based baseline model, we present a method to compute the error associated with estimates of several DR parameters. We also develop a metric to determine how much observed DR variability results from baseline model error rather than real variability in response. We analyze 38 C&I facilities participating in an automated DR program and find that DR parameter errors are large. Though some facilities exhibit real DR variability, most observed variability results from baseline model error. Therefore, facilities with variable DR parameters may actually respond consistently from event to event. Consequently, in DR programs in which repeatability is valued, individual buildings may be performing better than previously thought. In some cases, however, aggregations of C&I facilities exhibit real DR variability, which could create challenges for power system operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field evaluation of performance of HVAC optimization system in commercial buildings

Smart new building technologies that offer continuous dynamic optimization of Heating, Ventilation, and Air Conditioning (HVAC) control hold promise to advance building operations for efficiency and grid response. These technologies use data from the control system to determine the analytically optimal setpoints, and then write back the optimal setpoints into the control system to minimize system energy consumption or costs. There are limited studies documenting field validations of these technologies. This paper presents the results from a long-term field evaluation of a model-predictive HVAC optimization system that installed in four commercial buildings. Energy savings analysis was conducted based on pre/post submetered energy use. Across the cohort of evaluation sites, HVAC savings following the implementation of the optimization system were mixed, ranging from 0–9%. Analysis of site operational data showed that occupant comfort was neither positively nor negatively impacted. Key technology adoption considerations and recommendations are summarized in the paper. The technology performs best when HVAC systems are in good working condition, and can be exercised to achieve the full range of its optimized setpoints–however it may not provide extensive additional savings over cases where best practice sequences of operation and reset strategies are already comprehensively implemented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sequence-to-sequence neural networks for short-term electrical load forecasting in commercial office buildings

The U.S. power grid is transforming to become smarter, cleaner, and more effi- cient. This is leading to the addition of significant distributed variable renew- able generation. Due to the variable nature of renewable generation, the short- and long-term supply-demand imbalances are less predictable, and conventional approaches to mitigating the imbalance will not be efficient or cost-effective. To address this challenge, transactive control technologies have been proposed which balance energy generation and consumption with market activity and in- frastructural limitations. Transactive control requires the ability of individual end-use loads to express flexibility as a function of a transactive signal (e.g., price). Empirical gray- and black-box models have been widely used to express flexibility, and although these approaches are generally easy to construct and simple to use, they do not capture the non-linear behavior that some end-use loads represent . Machine learning approaches have been proposed to address this limitation. Although deep learning approaches for forecasting end-use loads have been explored, certain aspects of the application of deep models to load forecasting are not well understood. These aspects include how much training data is required, and how models should be structured and trained. To that end, this work explores how to approach applying deep recurrent neural networks to short-term electrical load forecasting with a case study of four commercial office buildings. We identify data requirements for training accurate models of whole building electricity use conditioned on outdoor temperature, provide insight into model hyperparameter sensitivity, and demonstrate how readily models can be generalized to unseen buildings.

Skomski, Elliott↗