Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Computational Exploration of High Entropy Alloys as Promising Materials for Future Beam Windows

With the ever-increasing demand for high beam power, the currently used beam-intercepting devices (BIDs) such as targets, and beam windows may not be able to handle the high power required for future accelerator complexes or the lifetime may be reduced drastically. As beam power increases, the damage incurred by BIDs, including thermal shock, fatigue, and irradiation damage, also rises. Therefore, it is imperative to design materials that can withstand high beam power for longer lifetimes. High entropy alloys (HEAs) have emerged as potential alternative materials for designing next-generation BIDs. In this study, we primarily focus on materials for developing beam windows for next-generation accelerator complexes. We propose an integrated approach that combines various computational techniques to study and design new materials. Specifically, we use CALPHAD, density functional theory (DFT), and molecular dynamics (MD) to comprehensively investigate the defect properties of suitable HEAs, offering potential alternatives for future beam windows. We begin by scanning the extensive phase space provided by Cr-Mn-V-Ti-Al-Co HEAs, selecting 8 compositions after evaluating approximately 120,000 unique compositions using CALPHAD. We, then employ DFT-informed machine learning techniques to develop force-field parameters. Finally, MD simulations using these developed force-field parameters will be used to study the effects of radiation damage on the defect and mechanical properties of the selected alloys. This research explains the use of the CALPHAD approach and shows how critical modeling (DFT and MD) is in developing novel material such as HEAs. It also highlights the promising role of machine learning in this field. The results from this study will greatly improve the novel materials development to be used in next-generation accelerator components, leading to higher beam power and longer operational times of BIDs.

43 PARTICLE ACCELERATORS↗

Extension of vibrational power flow techniques to two-dimensional structures

In the analysis of the vibration response and structure-borne vibration transmission between elements of a complex structure, statistical energy analysis (SEA) or Finite Element Analysis (FEA) are generally used. However, an alternative method is using vibrational power flow techniques which can be especially useful in the mid- frequencies between the optimum frequency regimes for FEA and SEA. Power flow analysis has in general been used on one-dimensional beam-like structures or between structures with point joints. In this paper, the power flow technique is extended to two-dimensional plate like structures joined along a common edge without frequency or spatial averaging the results, such that the resonant response of the structure is determined. The power flow results are compared to results obtained using FEA at low frequencies and SEA at high frequencies. The agreement with FEA results is good but the power flow technique has an improved computational efficiency. Compared to the SEA results the power flow results show a closer representation of the actual response of the structure.

Cuschieri, J. M.↗

Power flow analysis of an L-shaped plate structure

In the analysis of the vibration response and structure-borne vibration transmission between elements of a complex structure, statistical energy analysis (SEA) or finite element analysis (FEA) are generally used. However, an alternative method is using vibrational power flow techniques which can be especially useful in the mid frequencies between the optimum frequency regimes for FEA and SEA. Power flow analysis has in general been used on one-dimensional beam-like structures or between structures with point joints. In this paper, the power flow technique is extended to two-dimensional plate like structures joined along a common edge without frequency or spatial averaging the results, such that the resonant response of the structure is determined. The power flow results are compared to results obtained using FEA at low frequencies and SEA at high frequencies. The agreement with FEA results is good but the power flow technique has an improved computational efficiency. Compared to the SEA results the power flow results show a closer representation of the actual response of the structure.

Cuschieri, J. M.↗

Profiling with the electron microscope.

Discussion of a profiling technique using a scanning electron microscope for obtaining depth information on a single micrograph of a small specimen. A stationary electron beam is used to form a series of contamination spots in a line across the specimen. Micrographs obtained by this technique are useful as a means of projection and display where stereo viewers are not practical.

Vedder, J. F.↗

Experimental investigations of elastohydrodynamic lubrication

Various experimental studies of elastohydrodynamic lubrication have been reviewed. The various types of machines used in these investigations, such as the disc, two and four ball, crossed-cylinders, and crossed-axes rolling disc machine, are described. The measurement of the most important parameters, such as film shape, film thickness, pressure, temperature, and traction, is considered. Determination of the film thickness is generally the most important of these effects since it dictates the extent to which the asperities on opposing surfaces can come into contact and thus has a direct bearing on wear and fatigue failure of the contacting surfaces. Several different techniques for measuring film thickness have been described, including electrical resistance, capacitance, X-ray, optical interferometry, laser beam diffraction, strain gage, and spring dynamometer methods. An attempt has been made to describe the basic concepts and limitations of each of these techniques. These various methods have been used by individual researchers, but there is no universally acceptable technique for measuring elastohydrodynamic film thickness. Capacitance methods have provided most of the reliable data for nominal line or rectangular conjunctions, but optical interferometry has proved to be the most effective procedure for elliptical contacts. Optical interferometry has the great advantage that it reveals not only the film thickness, but also details of the film shape over the complete area of the conjunction.

Hamrock, B. J.↗

Silicon Holder For Molecular-Beam Epitaxy

Simple assembly of silicon wafers holds silicon-based charge-coupled device (CCD) during postprocessing in which silicon deposited by molecular-beam epitaxy. Attains temperatures similar to CCD, so hotspots suppressed. Coefficients of thermal expansion of holder and CCD equal, so thermal stresses caused by differential thermal expansion and contraction do not develop. Holder readily fabricated, by standard silicon processing techniques, to accommodate various CCD geometries. Silicon does not contaminate CCD or molecular-beam-epitaxy vacuum chamber.

Hoenk, Michael E.↗

An ultra-compact x-ray free-electron laser

In the field of beam physics, two frontier topics have taken center stage due to their potential to enable new approaches to discovery in a wide swath of science. These areas are: advanced, high gradient acceleration techniques, and x-ray free electron lasers (XFELs). Further, there is intense interest in the marriage of these two fields, with the goal of producing a very compact XFEL. In this context, recent advances in high gradient radio-frequency cryogenic copper structure research have opened the door to the use of surface electric fields between 250 and 500 MV m -1 . Such an approach is foreseen to enable a new generation of photoinjectors with six-dimensional beam brightness beyond the current state-of-the-art by well over an order of magnitude. This advance is an essential ingredient enabling an ultra-compact XFEL (UC-XFEL). In addition, one may accelerate these bright beams to GeV scale in less than 10 m. Such an injector, when combined with inverse free electron laser-based bunching techniques can produce multi-kA beams with unprecedented beam quality, quantified by 50 nm-rad normalized emittances. The emittance, we note, is the effective area in transverse phase space (x, p x /m e c) or (y, p y /m e c) occupied by the beam distribution, and it is relevant to achievable beam sizes as well as setting a limit on FEL wavelength. These beams, when injected into innovative, short-period (1–10 mm) undulators uniquely enable UC-XFELs having footprints consistent with university-scale laboratories. We describe the architecture and predicted performance of this novel light source, which promises photon production per pulse of a few percent of existing XFEL sources. We review implementation issues including collective beam effects, compact x-ray optics systems, and other relevant technical challenges. To illustrate the potential of such a light source to fundamentally change the current paradigm of XFELs with their limited access, we examine possible applications in biology, chemistry, materials, atomic physics, industry, and medicine—including the imaging of virus particles—which may profit from this new model of performing XFEL science.

47 OTHER INSTRUMENTATION↗

Parametric estimation of Poisson's ratio for thin hinged-hinged plates

Cornu's method is an elegant calculation besieged by an impractical approach to obtain accurate estimates for Poisson's ratio. Conventionally, Cornu's method requires several components, and each component can adversely affect the accuracy of the measurement. Furthermore, Cornu's conventional method requires a long beam because beams with short length-to-width ratios cause the estimate of Poisson's ratio to diverge from the true value of Poisson's ratio. We believe that, with the right modifications, Cornu's method can become an attractive approach to obtaining precise estimates for Poisson's ratio from mode shapes. Here we use finite element simulations to show how to use Cornu's method to estimate Poisson's ratio from a mode shape. Our modified Cornu's method removes knife-edges and loading components for a hinged-hinged plate under steady-state excitation. Given the true value of Poisson's ratio, as a performance specification, we show that simple parametric expressions can fit estimates for Poisson's ratio for different length-to-width ratios of thin hinged-hinged plates. Additionally, we show that estimates for Poisson's ratio from higher modes align with the results from the first mode and explain our expectation for this outcome. Furthermore, our results challenge the idea that anticlastic, monoclastic, and synclastic deformation uniquely correspond to positive, zero, and negative estimates of Poisson's ratio, respectively. With the emergence of materials-by-design, we expect that this parametric technique will be able to assist in experimental qualification of thin beam and plate structures with respect to the desired value of Poisson's ratio.

42 ENGINEERING↗

Fluidic Flow Assisted Deterministic Folding of Van der Waals Materials

Origami offers a distinct approach for designing and engineering new material structures and properties. The folding and stacking of atomically thin van der Waals (vdW) materials, for example, can lead to intriguing new physical properties including bandgap tuning, Van Hove singularity, and superconductivity. On the other hand, achieving well-controlled folding of vdW materials with high spatial precision has been extremely challenging and difficult to scale toward large areas. In this paper, a deterministic technique is reported to fold vdW materials at a defined position and direction using microfluidic forces. Electron beam lithography (EBL) is utilized to define the folding area, which allows precise control of the folding geometry, direction, and position beyond 100 nm resolution. Using this technique, single-atomic-layer vdW materials or their heterostructures can be folded without the need for any external supporting layers in the final folded structure. In addition, arrays of patterns can be folded across a large area using this technique and electronic devices that can reconfigure device functionalities through folding are also demonstrated. Such scalable formation of folded vdW material structures with high precision can lead to the creation of new atomic-scale materials and superlattices as well as opening the door to realizing foldable and reconfigurable electronics.

2D materials↗

Enabling the Acquisition of Electron Beam-Induced Current (EBIC) Images in Conventional SEM and STEM Instruments

Electron beam-induced current (EBIC) imaging is a well-established scanning electron microscope (SEM) technique used to analyze the behavior of microelectronic devices including solar cells. Recently, the application of EBIC imaging in an aberration-corrected scanning transmission electron microscope (STEM) has been demonstrated and offers great potential for the in situ study of electronic materials, correlating charge transport properties to atomic structural and elemental information. Here, this work presents two ways to implement EBIC imaging in conventional SEM and STEM systems: one relying on the instrument's inherent scanning and imaging electronics and the other involving third-party systems usually available in electron microscopes. The implementation of lock-in EBIC in systems equipped with a fast beam blanker is also described. In addition, this work shows and discusses the different mechanisms at play in EBIC imaging and their dependence on beam energy, sample impedance, and electrical measurement configuration, providing researchers with the basic information needed to apply the technique to their research.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Technique Developed for Optimizing Traveling-Wave Tubes

A traveling-wave tube (TWT) is an electron beam device that is used to amplify electromagnetic communication waves at radio and microwave frequencies. TWT s are critical components in deep-space probes, geosynchronous communication satellites, and high-power radar systems. Power efficiency is of paramount importance for TWT s employed in deep-space probes and communications satellites. Consequently, increasing the power efficiency of TWT s has been the primary goal of the TWT group at the NASA Lewis Research Center over the last 25 years. An in-house effort produced a technique (ref. 1) to design TWT's for optimized power efficiency. This technique is based on simulated annealing, which has an advantage over conventional optimization techniques in that it enables the best possible solution to be obtained (ref. 2). A simulated annealing algorithm was created and integrated into the NASA TWT computer model (ref. 3). The new technique almost doubled the computed conversion power efficiency of a TWT from 7.1 to 13.5 percent (ref. 1).

Wilson, Jeffrey D.↗

Bonding aluminum beam leads

Report makes it relatively easy for hybrid-circuit manufacturers to convert integrated circuit chips with aluminum bead leads. Report covers: techniques for handling tiny chips; proper geometries for ultrasonic bonding tips; best combinations of pressure, pulse time, and ultrasonic energy for bonding; and best thickness for metal films to which beam leads are bonded.

Burkett, F. S.↗

The response of a 300 micron silicon detector to monoenergetic neutrons determined by the use of the Monte Carlo technique

The response of a 300 micron thick silicon detector to an incident monoenergetic neutron beam is evaluated by the Monte Carlo method for the cases of both a shielded and a bare detector. The result of Monte Carlo calculation, using elastic, inelastic, and absorption reactions indicates that the response of the silicon detector to neutrons is basically due to the elastic scattering. In addition, the gamma rays generated in the shield of the detector will result in a response which is 3 or 4 orders of magnitude smaller than response to incident photons. The response of a bare silicon detector is calculated for neutron energies up to 6 MeV and bias energies from 50 to 250 KeV. It is found that the maximum response for a 300 micron thick silicon detector is less than .004 c/n within this selected neutron and bias energy range. When the pulse height defect is introduced in the calculation the results at low energy neutrons were reduced.

Tahezadeh, M.↗

A LENS on DUNE-PRISM: Characterizing a Neutrino Beam with Off-Axis Measurements

Upcoming precision long-baseline neutrino oscillation experiments will be severely limited by the large systematic uncertainties associated with neutrino flux predictions and neutrino--nucleus cross sections. A promising remedy is the PRISM (Precision Reaction Independent Spectrum Measurement) technique, whereby the near detector measures the neutrino spectrum at different angles with respect to the beam axis. These measurements are then linearly combined into a prediction of the oscillated neutrino flux at the far detector. This prediction is data-driven, but still dependent on some theoretical knowledge about the neutrino flux. In this paper, we study to what extent off-axis measurements themselves can be used to directly constrain neutrino flux models. In particular, we use them to extract separately the fluxes and spectra of different meson species in the beam. We call this measurement LENS (Lateral Extraction of Neutrino Spectra). Second, we demonstrate how the thus improved flux model helps to further constrain the far detector flux prediction, thereby ultimately improving oscillation measurements.

FOS: Physical sciences↗

High-precision mass measurement of 103 Sn restores smoothness of the mass surface

As a step towards the ultimate goal of a high-precision mass measurement of doubly magic 100 Sn, the mass of 103 Sn was measured at the Low Energy Beam and Ion Trap (LEBIT) located at the Facility for Rare Isotope Beams (FRIB). Utilizing the time-of-flight ion cyclotron resonance technique, a mass uncertainty of 3.7 keV was achieved, an improvement by more than an order of magnitude compared to a recent measurement performed in 2023 at the Cooler Storage Ring (CSRe) in Lanzhou. Although the LEBIT and CSRe mass measurements of 103 Sn are in agreement, they diverge from the experimental mass value reported in the 2016 version of the Atomic Mass Evaluation (AME2016), which was derived from the measured 𝑄 𝛽 + value and the mass of 103 In. In AME2020, this indirectly measured 103 Sn mass was classified as a “seriously irregular mass” and replaced with an extrapolated value, which aligns with the most recent measured values from CSRe and LEBIT. As such, the smoothness of the mass surface is confidently reestablished for 103 Sn. Here, LEBIT's mass measurement of 103 Sn enabled a significant reduction in the mass uncertainties of five parent isotopes which are now dominated by uncertainties in their respective 𝑄 values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Concepts for 20/30 GHz satcom systems for direct-to-user applications

A baseline technique is described for implementing a direct-to-user (DTU) satcom communications system at 20/30 GHz transmission frequency. The purpose of this application is to utilize the high capacity frequency spectrum at K(A) band for communications among thousands of small terminals located at or close to a customer's facility. The baseline DTU system utilizes a TDMA method of communications with QPSK modulation. Twenty-five coverage beams from a geosynchronous orbit spacecraft provide full coverage of CONUS. Low cost terminals are limited to less than 4.5 meters diameter. The impact of rain attenuation on communications availability is examined. Other techniques including satellite switched antenna beams are outlined and critical K(A)-band technology developments are identified.

Jorasch, R.↗

Accurate prediction of mega-electron-volt electron beam properties from UED using machine learning

To harness the full potential of the ultrafast electron diffraction (UED) and microscopy (UEM), we must know accurately the electron beam properties, such as emittance, energy spread, spatial-pointing jitter, and shot-to-shot energy fluctuation. Owing to the inherent fluctuations in UED/UEM instruments, obtaining such detailed knowledge requires real-time characterization of the beam properties for each electron bunch. While diagnostics of these properties exist, they are often invasive, and many of them cannot operate at a high repetition rate. Here, we present a technique to overcome such limitations. Employing a machine learning (ML) strategy, we can accurately predict electron beam properties for every shot using only parameters that are easily recorded at high repetition rate by the detector while the experiments are ongoing, by training a model on a small set of fully diagnosed bunches. Applying ML as real-time noninvasive diagnostics could enable some new capabilities, e.g., online optimization of the long-term stability and fine single-shot quality of the electron beam, filtering the events and making online corrections of the data for time-resolved UED, otherwise impossible. This opens the possibility of fully realizing the potential of high repetition rate UED and UEM for life science and condensed matter physics applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗