Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “additional protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Advanced Communication and Networking Technologies for Mars Exploration

Next-generation Mars communications networks will provide communications and navigation services to a wide variety of Mars science vehicles including: spacecraft that are arriving at Mars, spacecraft that are entering and descending in the Mars atmosphere, scientific orbiter spacecraft, spacecraft that return Mars samples to Earth, landers, rovers, aerobots, airplanes, and sensing pods. In the current architecture plans, the communication services will be provided using capabilities deployed on the science vehicles as well as dedicated communication satellites that will together make up the Mars network. This network will evolve as additional vehicles arrive, depart or end their useful missions. Cost savings and increased reliability will result from the ability to share communication services between missions. This paper discusses the basic architecture that is needed to support the Mars Communications Network part of NASA's Space Science Enterprise (SSE) communications architecture. The network may use various networking technologies such as those employed in the terrestrial Internet, as well as special purpose deep-space protocols to move data and commands autonomously between vehicles, at disparate Mars vicinity sites (on the surface or in near-Mars space) and between Mars vehicles and earthbound users. The architecture of the spacecraft on-board local communications is being reconsidered in light of these new networking requirements. The trend towards increasingly autonomous operation of the spacecraft is aimed at reducing the dependence on resource scheduling provided by Earth-based operators and increasing system fault tolerance. However, these benefits will result in increased communication and software development requirements. As a result, the envisioned Mars communications infrastructure requires both hardware and protocol technology advancements. This paper will describe a number of the critical technology needs and some of the ongoing research activities.

Bhasin, Kul↗

SpaceWire as a Cube-Sat Instrument Interface

SpaceWire is used in the control and data interface for an instrument on a pair of small satellites, one of which was launched in summer 2017. The instrument SpaceWire interface is implemented in a Field Programmable Gate Array as an instantiated core controlled by a LEON3FT CPU, which is also implemented as an instantiated core. The UT699 processor in the flight computer provides the spacecraft side’s SpaceWire interface. A simple message based protocol consisting of four message types was defined, based on existing SpaceWire standards. One was for passing commands to and responses from the instrument in the form of text strings similar to those from a system console where each line of text is passed in a SpaceWire message. Another was for passing spacecraft time to the instrument. The third was for transferring files using a subset of the Remote Memory Access Protocol (RMAP). The fourth was for retrieving science data from the instrument. A set of user application programming interface (API) routines provided an abstracted interface to both the serial console (used during debug) and the SpaceWire device interface. Early instrument development and testing was done with a set of utilities that controlled a Star-Dundee USB-SpaceWire brick providing a user interface similar to a serial console terminal emulator with the addition of file and data transfers. Later in the integration and test process, these utilities were integrated with the COSMOS ground systems software used for spacecraft control, providing a seamless transition from standalone instrument tests to benchtop flat-sat test and full spacecraft level tests.

Lux, James P.↗

Analysis of Surface Nitrides Created During "Doping" Heat Treatments of Niobium

The benefits of reduced RF losses from interstitial "doping" of niobium are well established. Many of the details involved in the process remain yet to be elucidated. The niobium surface reacted with low-pressure nitrogen at 800°C presents a surface with chemical reactivity different than standard niobium. While standard "recipes" are being used to produce cavities, we seek additional insight into the chemical processes that may be used to remove the "undesirable" as-formed surface layer. This may lead to new processing routes or quality assurance methods to build confidence that all surface "nitrides" have been removed. We report a series of alternate chemistry treatments and subsequent morphological examinations and interpret the results. We also introduce a new standardized Nb sample system in use for efficient characterization of varying doping protocols and cross-laboratory calibration.

Spradlin, J. K.↗

Role of NDE and In-Situ Process Monitoring in Managing Risk of AM Space Hardware

The recently published NASA-STD-6030 defines the Additive Manufacturing (AM) Requirements for Spaceflight Systems. Key aspects of the certification approach include the development of a qualified material process (QMP) and material characterization determined by part classification. Nondestructive evaluation (NDE) of the full surface and volume is required for all part classifications except those with negligible risk. NASA is exploring the use of in-process monitoring data to improve risk posture and supplement post-build inspection for complex parts. Currently, the most challenging obstacle to overcome is linking the indications in the monitoring data to the physics of the process and the final material state of the finished part. NASA is undertaking studies to understand and quantify this relationship for various monitoring methods. The desired goal is to develop a protocol to establish this correlation for any monitoring method. Once this correlation is known, the critical defect size can be linked to a representative indication in the monitoring data, and the capability of the monitoring system can be tested using the 90/95 probability of detection requirement for NDE methods. This would enable the use of in-process monitoring as a defect screening activity for AM part certification. Many high-criticality components built with AM have high complexity and therefore limited inspectability, so using in-process monitoring can help address this certification gap. The use of adaptive, closed-loop monitoring systems that alter the locked process will require a new approach to the QMP.

additive manufacturing↗

Role of NDE and In-Situ Process Monitoring in Managing Risk of AM Space Hardware

The recently published NASA-STD-6030 defines the Additive Manufacturing (AM) Requirements for Spaceflight Systems. Key aspects of the certification approach include the development of a qualified material process (QMP) and material characterization determined by part classification. Nondestructive evaluation (NDE) of the full surface and volume is required for all part classifications except those with negligible risk. NASA is exploring the use of in-process monitoring data to improve risk posture and supplement post-build inspection for complex parts. Currently, the most challenging obstacle to overcome is linking the indications in the monitoring data to the physics of the process and the final material state of the finished part. NASA is undertaking studies to understand and quantify this relationship for various monitoring methods. The desired goal is to develop a protocol to establish this correlation for any monitoring method. Once this correlation is known, the critical defect size can be linked to a representative indication in the monitoring data, and the capability of the monitoring system can be tested using the 90/95 probability of detection requirement for NDE methods. This would enable the use of in-process monitoring as a defect screening activity for AM part certification. Many high-criticality components built with AM have high complexity and therefore limited inspectability, so using in-process monitoring can help address this certification gap. The use of adaptive, closed-loop monitoring systems that alter the locked process will require a new approach to the QMP.

advanced manufacturing↗

Multi-site Milling Strategy Reveals Significant Variation in Biomass Composition of Switchgrass ( Panicum virgatum ) Grown at Ten Locations

Cell wall composition influences biomass use as a forage and as a feedstock for biofuel and chemical conversion. To examine the influence of environment on composition of switchgrass (Panicum virgatum L.), we utilized a multi-environment experiment consisting of clones of switchgrass genotypes grown at up to ten locations in the continental US. We tested the influence of different milling treatments on biomass composition trait predictions via near-infrared reflectance spectroscopy (NIRS). We found that most compositional trait predictions (29/34) were significantly different (P < 0.05) when a single lot of biomass was subjected to disparate milling treatments, i.e., knife milling vs. knife milling with an additional cyclone milling. Further, depending on the plant material tested, three to eight compositional trait predictions vary (P < 0.05) when identical biomass was knife milled at different sites followed by cyclone milling at a single site, including for traits such as Klason lignin, nitrogen, and carbon. In some cases, variation due to milling site exceeded environmentally induced compositional variation of a single switchgrass genotype grown at different sites. From these observations, we recommend a protocol with two sequential millings that decouples growth environment from a particular mill. Utilizing this approach, we found that 46/46 biomass composition traits from the warm season herbaceous forage and switchgrass bioethanol NIRS equations vary significantly (P < 0.001) in clones of a switchgrass genotype (WBC) grown at ten sites, with the growth site representing the largest average source of variation (41%). This multi-site milling approach can be used to examine environmental and gene-by-environment influences on composition with the goal of optimizing cell wall composition in different environments for biomass utilization.

09 BIOMASS FUELS↗

A Lakehouse Architecture for the Management and Analysis of Heterogeneous Data for Biomedical Research and Mega-biobanks

Data Lakehouse is a new paradigm in data architectures that embodies and integrates already established concepts for the systematic management of disparate, large-scale data – a data lake for heterogeneous data management, use of open standards for high-performance querying, and systematic maintenance of the data "freshness". In addition to being a new concept, the data lakehouse is also still a conceptual construct. Many projects that use the lakehouse require maturing, empirical studies, and specific implementations. In this paper, we present our implementation of the data lakehouse concept in a biomedical research and health data analytics domain, and we discuss the implementation of some unique and novel features such as support for specialized access controls in support of HIPAA regulation and IRB protocols, and support for the FAIR standard.

Begoli, Edmon↗

SU-F-J-143: Initial Assessment of Image Quality of An Integrated MR-Linac System with ACR Phantom

Purpose/Objective(s): To assess the image quality of an integrated MR-Linac system and compare with other MRI systems that are primarily used for diagnostic purposes. Materials/Methods: An ACR MRI quality control (QC) phantom was used to evaluate the image quality of a fully integrated 1.5T MRI-Linac system recently installed at our institution. This system has a new split magnet design which gives the magnetic field strength of 1.5T. All images were acquired with a set of phased-array surface coils which are designed to have minimal attention of radiation beam. The anterior coil rests on a coil holder which keeps the anterior coil’s position consistent for QA purposes. The posterior coil is imbedded in the patient couch. Multiple sets of T1, T2/PD images were acquired using the protocols as prescribed by the ACR on three different dates, ranging 3 months apart. Results: The geometric distortion are within 0.5 mm in the axial scans and within 1mm in the saggital (z-direction) scans. Slice thickness accuracy, image uniformity, ghosting ratio, high contrast detectability are comparable to other 1.5T diagnostic MRI scanners. The low-contrast object detectability are lower comparatively, which is a result of using the body array coil. Additionally, the beam’s-eye-view images (oblique coronal and saggital images) have minimal geometric distortion at all linac gantry angles tested. No observable changes or drift in image quality is found from images acquired 3 month apart. Conclusion: Despite the use of a body array surface coil, the image quality is comparable to that of an 1.5T MRI scanner and is of sufficient quality to pass the ACR MRI accreditation program. The geometric distortion of the MRI system of the integrated MR-Linac is within 1mm for an object size similar to the ACR phantom, sufficient for radiation therapy treatment purpose. The authors received corporate sponsored research grants from Elekta which is the vendor for the MR-Linac evaluated in this study.

60 APPLIED LIFE SCIENCES↗

Advancing Multi-Hazard Risk and Safety Considerations for Aging Nuclear Facilities (Revision 1)

This project will demonstrate a multi-hazard time-dependent probabilistic risk assessment (PRA) approach for nuclear facilities considering aging-related deterioration of structures. A generic pressurized water reactor (PWR) reactor subjected to seismic mainshock-aftershock sequences considering the aging of the containment structure will be used as a case study to demonstrate the multi-hazard PRA approach. Using advanced modeling and simulation, seismic mainshock-aftershock fragility functions will be simulated for the containment structure considering aging effects. A multi-hazard PRA model for a generic PWR reactor will be built to quantify the multi-hazard core damage frequency (CDF) and large early release frequency (LERF) with explicit time-dependent modeling of event sequences. To date, the cascading impacts of multi-hazards are not adequately accounted for in the PRA models for nuclear facilities. In addition, for both initial and periodic evaluation of facilities to withstand natural phenomena hazards (NPH), deterioration of the SSCs due to aging and other effects is not adequately considered. By advancing multi-hazard considerations accounting for aging effects, this project will contribute to improved understanding of the safety of aging nuclear facilities. Project outcomes such as the multi-hazard CDF and LERF will also allow facility owners to optimize upgrade and retrofit protocols. This project is divided into two components: (1) advanced modeling and simulations; and (2) multi-hazard PRA. For the first component, Idaho National Laboratory’s (INL) Multi-hazard Analysis for STOchastic time-DOmaiN phenomena (MASTODON) and BlackBear codes will be used to simulate the seismic response and damage of a containment structure under cascading mainshock-aftershock sequences with aging effects. Uncertainties related to the seismic inputs, material parameters, and environmental factors such as temperature and humidity will be identified and propagated to the fragility functions. These fragility functions, which consider aging effects, will be time dependent. The second component will take the fragility information from the first component to build a multi-hazard time-dependent PRA model starting from a generic PWR model to evaluate the multi-hazard CDF and LERF and characterize the associated consequences. For this component, OpenPRA Web Application and SAPHIRE code will be used. Events such as the Fukushima Daiichi accident have highlighted the importance of considering the cascading impacts of multi-hazards for PRA. Moreover, many of the reactors in the current nuclear fleet in the United States (US) are already operating well beyond their initially planned design life, and applications for further extensions to operating licenses are being considered. Therefore, considering multi-hazard effects and aging deterioration in the NPH risk assessment process will contribute to the safety of both existing and future nuclear facilities. Outcomes of this project will thus directly benefit the standards DOE-STD-1020-16 and DOE-HDBK-1224-18.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Role for Lower Extremity Interstitial Fluid Volume Changes in the Development of Orthostasis after Simulated Microgravity

Reentry orthostasis after exposure to the conditions of spaceflight is a persistent problem among astronauts. In a previous study, a computer model systems analysis was used to examine the physiologic mechanisms involved in this phenomenon. In this analysis, it was determined that an augmented capacitance of lower extremity veins due to a fluid volume contracture of the surrounding interstitial spaces during spaceflight results in an increase in sequestered blood volume upon standing and appears to be the initiating mechanism responsible for reentry orthostasis. In this study, we attempt to validate the central premise of this hypothesis using a ground-based spaceflight analog. 10 healthy subjects were placed at bed rest in a 6 head down tilt position for 60 days of bed rest. The impact of adaptations in interstitial fluid volume and venous capacitance in the lower extremities were then observed during a standard tilt test protocol performed before and after the confinement period. The interstitial thickness superficial to the calcaneous immediately below the lateral malleolus was measured using ultrasound with a 17-5 MHz linear array transducer. Measurements of the changes in anterior tibial vein diameter during tilt were obtained by similar methods. The measurements were taken while the subjects were supine and then during upright tilt (80') for thirty minutes, or until the subject had signs of presyncope. Additional measurements of the superficial left tibia interstitial thickness and stroke volume by standard echocardiographic methods were also recorded. In addition, calf compliance was measured over a pressure range of 10-60 mmHg, using plethysmography, in a subset of these subjects (n = 5). There was a average of 6% diminution in the size of the lower extremity interstitial space as compared to measurements acquired prior to bed rest. This contracture of the interstitial space coincided with a subsequent relative increase in the percentage change in tibial vein diameter and stroke volume upon tilting in contrast to the observations made before bed rest (54 vs 23% respectively). Compliance in the calf increased by an average of 36% by day 27 of bedrest. A systems analysis using a computer model of cardiovascular physiology suggests that microgravity induced interstitial volume depletion results in an accentuation of venous blood volume sequestration and is the initiating event in reentry orthostasis. This hypothesis was tested in volunteer subjects using a ground-based spaceflight analog model that simulated the body fluid redistribution induced by microgravity exposure. Measurements of changes in the interstitial spaces and observed responses of the anterior tibial vein with tilt, together with the increase in calf compliance, were consistent with our proposed mechanism for the initiation of postflight orthostasis often seen in astronauts.

Platts, Steven H.↗

Comparison of Venous Return Characteristics with Right Ventricular Mechanics During Cephalic Fluid Shift

For my summer internship project, I organized a pilot study to analyze the effects of a cephalic fluid shift on venous return and right ventricular mechanics to increase right ventricular and venous knowledge. To accomplish this pilot study, I wrote a testing protocol, obtained Institutional Review Board (IRB) approval, completed subject payment forms, lead testing sessions, and analyzed the data. This experiment used -20deg head down tilt (20 HDT) as the ground based simulation for the fluid shift that occurs during spaceflight and compared it to data obtained from the seated and supine positions. Using echocardiography, data was collected for the right ventricle, hepatic vein, internal jugular vein, external jugular vein, and inferior vena cava. Additionally, non-invasive venous pressure measurements, similar to those soon to be done in-orbit, were collected. It was determined that the venous return from below the heard is increased during 20 HDT, which was supported by increased hepatic vein velocities, increased right ventricular inflow, and increased right ventricular strain at 20 HDT relative to seated values. Jugular veins in the neck undergo an increase in pressure and area, but no significant increase in flow, relative to seated values when a subject is tilted 20 HDT. Contrary to the initial expectations based on this jugular flow, there was no significant increase in central venous pressure, as evidenced by no change in Doppler indices for right arterial pressure or inferior vena cava diameter. It is suspected that these differences in pressure are due to the hydrostatic pressure indifference point shifting during tilt; there is a potential for a similar phenomenon with microgravity. This data will hopefully lead to a more in-depth understanding of the response of the body to microgravity and how those relate to the previously mentioned cardiovascular risk of fluid shift that is associated with spaceflight. These results were presented in greater detail to the Cardiovascular Laboratory and the Space Life Science Summer Institute, which helped me prepare for future graduate school research presentations. This internship allowed me to apply and expand the anatomy, physiology, and mechanics information I learned during my undergraduate degree in Biomedical Engineering to the cardiovascular system with the unique zero gravity perspective. Additionally, I was able to develop skills with data analysis techniques involving speckle tracking for ventricular strain and Doppler waveforms for blood velocities. Additionally, I was able to expand upon my previous work in the Cardiovascular Laboratory by writing a literature review on a data analysis project I completed last summer. Ultimately, this internship and venous relationship comparison project provided me with a significant learning experience and additional skill sets, which are applicable to my goals of attaining a Ph.D. in biomedical engineering with a focus on tissue engineering and the cardiovascular system.

Elliott, Morgan↗

Future Standardization of Space Telecommunications Radio System with Core Flight System

NASA Glenn Research Center (GRC) is integrating the NASA Space Telecommunications Radio System (STRS) Standard with the Core Flight System (cFS). The STRS standard provides a common, consistent framework to develop, qualify, operate and maintain complex, reconfigurable and reprogrammable radio systems. The cFS is a flexible, open architecture that features a plug-and-play software executive called the Core Flight Executive (cFE), a reusable library of software components for flight and space missions and an integrated tool suite. Together, STRS and cFS create a development environment that allows for STRS compliant applications to reference the STRS APIs through the cFS infrastructure. These APis are used to standardize the communication protocols on NASAs space SDRs. The cFE-STRS Operating Environment (OE) is a portable cFS library, which adds the ability to run STRS applications on existing cFS platforms. The purpose of this paper is to discuss the cFE-STRS OE prototype, preliminary experimental results performed using the Advanced Space Radio Platform (ASRP), the GRC Sband Ground Station and the SCaN (Space Communication and Navigation) Testbed currently flying onboard the International Space Station. Additionally, this paper presents a demonstration of the Consultative Committee for Space Data Systems (CCSDS) Spacecraft Onboard Interface Services (SOIS) using electronic data sheets inside cFE. This configuration allows for the data sheets to specify binary formats for data exchange between STRS applications. The integration of STRS with cFS leverages mission-proven platform functions and mitigates barriers to integration with future missions. This reduces flight software development time and the costs of software-defined radio (SDR) platforms. Furthermore, the combined benefits of STRS standardization with the flexibility of cFS provide an effective, reliable and modular framework to minimize software development efforts for spaceflight missions.

space communications↗

Siting protocols for marine and hydrokinetic energy projects

Project Objective: The purpose of this project is to identify and address regulatory issues that affect the cost, time and the management of potential effects as it relates to siting and permitting advanced water power technologies. Background: The overall goal of this effort is to reduce the cost, time and effort of managing potential effects from the development advanced water power projects as it relates to the regulatory process in siting and permitting. To achieve this goal, a multi-disciplinary team will collect and synthesize existing information regarding regulatory processes into a user-friendly online format. In addition, the team will develop a framework for project planning and assessment that can incorporate existing and new information. The team will actively collaborate and coordinate with other efforts that support or influence regulatory process. Throughout the process, the team will engage in an iterative, collaborative process for gathering input and testing ideas that involves the relevant stakeholders across all sectors at the national, regional, and all state levels.

16 TIDAL AND WAVE POWER↗

Shear Ram Verification Test Protocol (VTP) Best Practices

A blowout preventer (BOP) is a critical component used on subsea oil and gas wells during drilling, completion, and workover operations on the U. S. outer continental shelf (OCS). The purpose of the BOP is to seal oil and gas wells, and in the case of an emergency well-control event, to prevent the uncontrolled release of hydrocarbons. One of the most important components of the BOP is the hydraulically operated blind shear ram (BSR) that shears drilling-related components, such as drill pipes, casings, tubings, and wire-related tools that may have been placed in the well. In addition to shearing these components, the BSR must form a seal to keep hydrocarbons within the well bore, even when under the highest well-fluid pressures expected. The purpose of this document is for Argonne National Laboratory (ANL) to provide an independent view, based on current regulations, and best practices for testing and confirming the operability and suitability of BSRs under realistic (or actual) well conditions.

02 PETROLEUM↗

Analytical equations for CT dose profiles derived using a scatter kernel of Monte Carlo parentage with broad applicability to CT dosimetry problems

Purpose: Knowledge of the complete axial dose profile f(z), including its long scatter tails, provides the most complete (and flexible) description of the accumulated dose in CT scanning. The CTDI paradigm (including CTDI{sub vol}) requires shift-invariance along z (identical dose profiles spaced at equal intervals), and is therefore inapplicable to many of the new and complex shift-variant scan protocols, e.g., high dose perfusion studies using variable (or zero) pitch. In this work, a convolution-based beam model developed by Dixon et al.[Med. Phys. 32, 3712-3728, (2005)] updated with a scatter LSF kernel (or DSF) derived from a Monte Carlo simulation by Boone [Med. Phys. 36, 4547-4554 (2009)] is used to create an analytical equation for the axial dose profile f(z) in a cylindrical phantom. Using f(z), equations are derived which provide the analytical description of conventional (axial and helical) dose, demonstrating its physical underpinnings; and likewise for the peak axial dose f(0) appropriate to stationary phantom cone beam CT, (SCBCT). The methodology can also be applied to dose calculations in shift-variant scan protocols. This paper is an extension of our recent work Dixon and Boone [Med. Phys. 37, 2703-2718 (2010)], which dealt only with the properties of the peak dose f(0), its relationship to CTDI, and its appropriateness to SCBCT. Methods: The experimental beam profile data f(z) of Mori et al.[Med. Phys. 32, 1061-1069 (2005)] from a 256 channel prototype cone beam scanner for beam widths (apertures) ranging from a = 28 to 138 mm are used to corroborate the theoretical axial profiles in a 32 cm PMMA body phantom. Results: The theoretical functions f(z) closely-matched the central axis experimental profile data{sup 11} for all apertures (a = 28 -138 mm). Integration of f(z) likewise yields analytical equations for all the (CTDI-based) dosimetric quantities of conventional CT (including CTDI{sub L} itself) in addition to the peak dose f(0) relevant to SCBCT (allowing direct cross-comparison between CT scan modes and mathematical proofs of several hypotheses of practical utility in CT dosimetry). A fast, analytical dose simulator{sup 6} is also demonstrated--successfully matching complex dose distributions measured using OSL and film dosimetry. Conclusions: The model described allows one to obtain analytical functions describing both the primary and scatter components of the axial dose profile. This model (using no empirical functions or adjustable fit parameters) provides a good match to the experimental data, as well as a complete analytical description of dose for both conventional (axial and helical) CT and cone beam CT. An efficient method whereby the complete data set for both modalities can be obtained from a single measurement of either CTDI{sub 100} or f(0) is illustrated. This method is also flexible--allowing calculation of heretofore unattainable doses for recently-introduced shift-variant protocols [e.g., variable pitch (irregular scan spacing), variable aperture, shuttle mode acquisition, and mA modulation schemes].

61 RADIATION PROTECTION AND DOSIMETRY↗

Comprehensive compartmental model and calibration algorithm for the study of clinical implications of the population-level spread of COVID-19: a study protocol

The complex dynamics of the coronavirus disease 2019 (COVID-19) pandemic has made obtaining reliable long-term forecasts of the disease progression difficult. Simple mechanistic models with deterministic parameters are useful for short-term predictions but have ultimately been unsuccessful in extrapolating the trajectory of the pandemic because of unmodelled dynamics and the unrealistic level of certainty that is assumed in the predictions. We propose a 22-compartment epidemiological model that includes compartments not previously considered concurrently, to account for the effects of vaccination, asymptomatic individuals, inadequate access to hospital care, post-acute COVID-19 and recovery with long-term health complications. Additionally, new connections between compartments introduce new dynamics to the system and provide a framework to study the sensitivity of model outputs to several concurrent effects, including temporary immunity, vaccination rate and vaccine effectiveness. Subject to data availability for a given region, we discuss a means by which population demographics (age, comorbidity, socioeconomic status, sex and geographical location) and clinically relevant information (different variants, different vaccines) can be incorporated within the 22-compartment framework. Considering a probabilistic interpretation of the parameters allows the model's predictions to reflect the current state of uncertainty about the model parameters and model states. We propose the use of a sparse Bayesian learning algorithm for parameter calibration and model selection. This methodology considers a combination of prescribed parameter prior distributions for parameters that are known to be essential to the modelled dynamics and automatic relevance determination priors for parameters whose relevance is questionable. This is useful as it helps prevent overfitting the available epidemiological data when calibrating the parameters of the proposed model. Population-level administrative health data will serve as partial observations of the model states.

59 BASIC BIOLOGICAL SCIENCES↗

Investigation of Membrane Chemical Degradation as a Function of Catalyst Platinum Loading

Membrane chemical degradation is one of many factors that can impact fuel cell durability. Additionally, the fuel cell’s lifetime heavily depends on the membrane and its ability to maintain chemical and mechanical integrity. Previous studies indicate that chemical degradation is due to the formation of hydroxyl radicals that attack the polymer structure resulting in membrane thinning, pinhole formation, and the release of fluoride and sulfate ions. Membrane durability was investigated using ultra-low Pt electrode loadings (≤ 0.1 mg Pt cm -2 ). Accelerated stress testing (US-DOE protocols) demonstrated that the degradation rate was found to increase with higher Pt loadings. This is most likely due to more heterogeneous sites for radical formation due to hydrogen crossover to the cathode. We also explored membrane degradation rates while varying catalyst layer thickness, ionomer to carbon ratio, and types of carbon support. All of the aforementioned variables impact the membrane degradation rates.

25 ENERGY STORAGE↗

Depth-Resolved Lithiated Gradients in Pristine and Laser-Ablated Anodes During Fast Charging

Laser ablating 3D electrode microstructures is a technique to improve Li-ion battery fast-charge performance. This technique has been theoretically proposed and electrochemically validated previously in the literature. The fundamental principle underlying laser ablation is that the ablated features reduce Li-ion transport pathways, improving access to the electrode active material near the current collector. This, in turn, promotes more homogeneous electrode utilization. The present study seeks to directly affirm the physics attributed to laser ablation using operando high-speed synchrotron X-ray diffraction. In this study, depth-resolved graphite lithiation gradients are measured operando during high-rate (15 min) charging. The depth-resolved lithiation dynamics of both ablated and non-ablated anodes are compared. The results highlight that the laser-ablated graphite electrode has notably more homogeneous utilization as compared to the non-ablated electrode. Additionally, the ablated electrode has a significant delay in reaching the maximum graphite lithiation at the separator, indicating less propensity for lithium plating. During low rate delithiation/discharge (2 hr), the two cells' lithiation gradients converge. Notably, a calibrated physics-based electrochemical model accurately reflects experimental findings, suggesting the potential to use pseudo-4D models not only to optimize laser ablation parameters in fast-charge capable electrodes but also to guide fast charging protocols that avoid lithium plating.

25 ENERGY STORAGE↗