Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ablator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

The ablation of graphitic materials in the sublimation regime.

A large variety of graphitic materials have been tested in an arc heated air stream at a surface pressure of 4.3 atm and a nominal surface temperature of 3925 K. Included were commercial and developmental grades of artificial graphites, both two and three dimensional carbon-carbon composites, composites seeded with refractory compounds, and several special materials such as pyrolytic graphite, mesophase graphite, glassy carbon, and natural graphite. ATJ graphite was used as a control material. Except for the seeded materials which had poor performance, the mass loss rate for all the man-made graphitic materials fell within the range of 17 per cent less to 30 per cent more than the rate for ATJ. Thus it is concluded that wide variations in constituents, processing, fabrication and structure have relatively little effect on the ablation performance of graphitic materials, at least under the conditions of the present tests. Particulate mass loss was observed for all the materials tested and is the dominant mechanism for mass removal at the present test conditions. It is suggested that this mechanism results from physical failure, primarily by compressive thermal stress.

Lundell, J. H.↗

Ablation and radiation coupled viscous hypersonic shock layers, volume 2

A computer program can be used to determine the radiative flux and flux divergence through a nonisothermal planar slab of gas is described. The program considers species typical of air at high temperatures and nylon or carbon phenolic ablation products. The equations solved are for a variable optical depth line and continuum gas model using species cross sections and line widths as the basic data.

Engel, C. D.↗

Effects of nonequilibrium ablation chemistry on Viking radio blackout.

The length of the entry blackout period during descent of the Viking Lander into the Mars atmosphere is predicted from calculated profiles of electron density in the shock layer over the aeroshell. Nonequilibrium chemistry plays a key role in the calculation, both in the inviscid flow and in the boundary layer. This is especially true in the boundary layer contaminated with ablation material, for which nonequilibrium chemistry predicts electron densities two decades lower than the same case calculated with equilibrium chemistry.

Evans, J. S.↗

Initial development of an ablative leading edge for the Space Shuttle orbiter.

A state-of-the-art preliminary design for typical wing areas is developed. Seven medium-density ablators (with/without honeycomb, flown on Apollo, Prime, X15A2) are evaluated. The screening tests include (1) leading-edge models sequentially subjected to ascent heating, cold soak, entry heating, post-entry pressure fluctuations, and touchdown shock, and (2) virgin/charred models subjected to bondline strains. Four materials (none molded) are found acceptable. The ESA 3560 HF and MOD 7 Hc (an AVCO 30 pcf elastomer) are selected. Roughness/recession degradation of low speed aerodynamics appears acceptable. The design, including attachments, substructure and joints, is presented.

Daforno, G.↗

Investigation of low-cost fabrication of ablative heat shields

The fabrication, testing, and evaluation of materials and techniques employed in the fabrication of ablative heat shield panels are described. Results of this effort show projected reductions in labor man-hours for dielectric curing of panels when compared to panels molded in a steam-heated press. In addition, panels were fabricated with more than one density within the cross-section. These dual-density panels show significant weight and cost reduction potentials.

Massions, V. P.↗

The effect of ablation injection on radiative and convective heating

A viscous shock-layer analysis is for calculating high energy equilibrium flow fields about blunt axisymmetric bodies is applied to the problem of massive ablation injection with radiation transport. A nongray radiation model is used that accounts for both line and continuum radiation. The solution method is direct and provides both stagnation and downstream solutions. Results for shock heated air show that phenolic-nylon injection is substantially more effective in reducing the wall radiant flux than air injection. Also, for large included body angles, the wall radiative flux and the coupled phenolic-nylon injection rate do not continue to decrease with increasing distance downstream.

Moss, J. N.↗

Modeling sublimation of a charring ablator

The Hertz-Knudsen analysis is shown to accurately predict the sublimation rate from a charring ablator. Porosity is shown to have a significant effect on the surface temperature. The predominant carbon species found in the vapor is C3, which agrees well with the results of previous investigations.

Balhoff, J. F.↗

Stagnation and downstream viscous shock-layer solutions with radiation and coupled ablation injection

This paper describes a rigorous viscous shock-layer analysis for investigating high energy equilibrium flow fields about blunt axisymmetric bodies. The analysis includes radiation transfer, mass injection, diffusion, and viscous effects. Radiation transfer is calculated with a nongray radiation model that accounts for line and continuum radiation. The analysis can treat all levels of blowing for both stagnation and downstream flow. Results are presented for selected earth entry conditions that demonstrate the essential features of this analysis. Particular emphasis is given to the effects of mass injection on stagnation and downstream flow. Results for both specified and coupled ablation injection are presented.

Moss, J. N.↗

Influence of ablation impurities on blunt body re-entry ionization

Electron density profiles which include the effect of an ablated sodium impurity were computed for the boundary layer on a blunt-nosed body re-entering the atmosphere at 7.62 km/sec. Profiles are computed from the nose to a distance of four diameters along the RAM C-payload. A finite-difference, laminar, nonequilibrium chemistry boundary-layer program was used. Comparison of theory with S-band diagnostic antenna results, electron concentration deduced from X- and C-band attenuation data, and Langmuir probe data at several different aft body locations show that agreement is good at high altitude. At the lower altitudes there is disagreement between theory and S-band antenna data where the apparent discrepancy is attributed to the three-body recombination rate constant used for deionization of sodium coupled with the effect of angle of attack.

Schexnayder, C. J., Jr.↗

Nonequilibrium boundary layer at a stagnation point for a hydrogen-helium stream over ablating graphite

The nonequilibrium axisymmetric stagnation point boundary layer over an ablating graphite surface is considered. The external stream is a high temperature mixture of hydrogen and helium. Variable thermodynamic and transport properties are assumed. Lennard-Jones potential model is used to calculate the transport coefficients of each species. Although the mixture rules for viscosity of the gas mixture are used, the weighting functions are more sophisticated than those commonly employed. For the conductivity of the mixture, generalized Wassiljewa coefficients are used. Seven species with 28 dissociation/recombination reactions are considered. Hansen's model for the dissociation rate constants is employed. The recombination rate constants are obtained by invoking detailed balance principles assisted by the JANAF thermodynamic data and the Hansen-Pearson thermodynamic data for C3.

Liu, T.-M.↗

Study of the ablative effects on tektite

The tumbling and surface roughness effects on the trajectory of entry tektite were studied in both free molecular and continuum flows. It is shown that, while surface roughness has negligible effect on trajectory, the tumbling may play an important role in tektite trajectory and the consequent ablation, provided the body shape is different from a sphere. A shape factor B was proposed to measure the shape irregularity and is found to be a good parameter for correlations between body shape and tumbling effects.

Chen, K. K.↗

Study of the ablative effects on tektite

The tumbling and surface roughness effects on the trajectory of entry tektite are studied in both free molecular and continuum flows. It was concluded that, while surface roughness has negligible effect on trajectory, the tumbling may play an important role in tektite trajectory and the consequent ablation, provided the body shape is different from a sphere. A shape factor was a good parameter for correlations between body shape and tumbling effects.

Chen, K. K.↗

Apparatus for experimental investigation of aerodynamic radiation with absorption by ablation products

A description is given and calibration procedures are presented for an apparatus that is used to simulate aerodynamic radiant heating during planetary entry. The primary function of the apparatus is to simulate the spectral distribution of shock layer radiation and to determine absorption effects of simulated ablation products which are injected into the stagnation region flow field. An electric arc heater is used to heat gas mixtures that represent the planetary atmospheres of interest. Spectral measurements are made with a vacuum ultraviolet scanning monochromator.

Wells, W. L.↗

Moldable cork ablation material

A successful thermal ablative material was manufactured. Moldable cork sheets were tested for density, tensile strength, tensile elongation, thermal conductivity, compression set, and specific heat. A moldable cork sheet, therefore, was established as a realistic product.

Source record↗

Intumescent-ablators as improved thermal protection materials

Nitroaromatic amine-based intumescent coatings were improved with regard to their thermal protection ability by adding endothermic decomposing fillers with endotherms at or near the exothermic reaction of the intumescent agent, since the effectiveness of the intumescent coatings without fillers is reduced by the exothermic behavior of the coatings during thermal activation. Fillers were dispersed directly in the base coating. Potassium fluoborate, ammonium fluoborate, zinc borate, and ammonium oxalate function as endothermic ablative materials at specific temperature regions, and also enhance the char formation during the intumescent process.

Sawko, P. M.↗