Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VOLUME”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

4f electron delocalization and volume collapse in praseodymium metal

We study the pressure evolution of the 4f electrons in elemental praseodymium metal compressed through several crystallographic phases, including the large volume-collapse transition at 20 GPa. Using resonant x-ray emission, we directly and quantitatively measure the development of multiple electronic configurations with differing 4f occupation numbers, the key quantum observable related to the delocalization of the strongly correlated 4f electrons. These results provide a high-fidelity test of prior predictions by dynamical mean-field theory, and support the hypothesis of a strong connection between electronic and structural degrees of freedom at the volume-collapse transition.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Excluded-volume model for quarkyonic matter: Three-flavor baryon-quark mixture

The single-flavor excluded-volume model based on the effective size of baryons reproduces the hard-soft density evolution of the equation of state (EoS) required by the recent studies of GW170817. This phenomenological model basically realizes the concept of quarkyonic matter which is introduced from large-$N_c$ gauge theory for dense matter. Further, enhanced nucleon interactions and dynamically generated quark degrees of freedom can reproduce the hard-soft evolution of the EoS. In this paper, we extend the excluded-volume model to a three-flavor system by considering electromagnetic charge and possible weak equilibrium in order to obtain a proper description for the hard-soft behavior of the EoS inferred from the gravitational waves observations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Two-neutrino double-𝛽 decay in pionless effective field theory from a Euclidean finite-volume correlation function

Two-neutrino double-β decay of certain nuclear isotopes is one of the rarest Standard Model processes observed in nature. Its neutrinoless counterpart is an exotic lepton-number nonconserving process that is widely searched to determine if the neutrinos are Majorana fermions. In order to connect the rate of these processes to the Standard Model and beyond the Standard Model interactions, it is essential that the corresponding nuclear matrix elements are constrained reliably from theory. Lattice quantum chromodynamics (LQCD) and low-energy effective field theories (EFTs) are expected to play an essential role in constraining the matrix element of the two-nucleon subprocess, which could in turn provide the input into ab initio nuclear-structure calculations in larger isotopes. Focusing on the two-neutrino process $nn\rightarrow pp(ee\bar{v}_{e}\bar{v}_e)$, the amplitude is constructed in this work in pionless EFT at next-to-leading order, demonstrating the emergence of a renormalization-scale independent amplitude and the absence of any new low-energy constant at this order beyond those present in the single-weak process. Most importantly, it is shown how a LQCD four-point correlation function in Euclidean and finite-volume spacetime can be used to constrain the Minkowski infinite-volume amplitude in the EFT. The same formalism is provided for the related single-weak process, which is an input to the double-β decay formalism. The LQCD-EFT matching procedure outlined for the double-weak amplitude paves the road toward constraining the two-nucleon matrix element entering the neutrinoless double-β decay amplitude with a light Majorana neutrino.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantum of volume in de Sitter space

We apply the nonstandard loop quantum cosmology method to quantize a flat Friedmann-Robertson-Walker cosmological model with a free scalar field and the cosmological constant {Lambda}>0. Modification of the Hamiltonian in terms of loop geometry parametrized by a length {lambda} introduces a scale dependence of the model. The spectrum of the volume operator is discrete and depends on {Lambda}. Relating quantum of the volume with an elementary lattice cell leads to an explicit dependence of {Lambda} on {lambda}. Based on this assumption, we investigate the possibility of interpreting {Lambda} as a running constant.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Inviscid simulations of expansion waves propagating into structured particle beds at low volume fractions

Expansion waves propagating into particle beds are found in many manmade and natural applications. Rapid decompression of a highly pressurized powder bed or a volcanic eruption are two such examples. In this investigation, we perform fully resolved simulations of expansion waves propagating into particle beds of three different volume fractions using the discontinuous Galerkin spectral element method code, cmt-nek. We validate state-of-the-art drag models for a particle in an unsteady compressible flow and show good agreement, particularly at lower volume fractions. We model the particle bed as a nozzle or area reduction and, using isentropic flow relations, predict the final pressure, temperature, and Mach number extremely well in each case.

42 ENGINEERING↗

Effect of Mach number and volume fraction in air-shock interacting with a bed of randomly distributed spherical particles

Shock-particle interaction is a fundamental problem in many engineering applications, with the dynamics being heavily influenced by the incident-shock Mach number and the particle volume fraction. In this paper we present fully resolved inviscid simulations of an incident-shock wave traveling through a bed of randomly distributed spherical particles. We vary the strength of the incident shock along with the particle volume fraction in order to study the complex wave interaction during shock-particle interaction. In this study we are interested in the early-time behavior during which the particles do not move and hence in our simulations all the particles are fixed in space. We compute the streamwise average of flow field quantities to generate the x - t contour plots to study the unsteady oscillations inside the particle bed. We observe that the transmitted shock slows down under certain conditions and it is partly due to tortuosity and partly due to weakening caused by energy dissipation. We also present the force histories of the streamwise drag and lift forces for all the particles. The random distribution of particles leads to high variability in the drag force experienced by the particles. We compute the mean peak drag force as a function of the streamwise location to study the mean behavior of the transmitted shock. Based on our findings, we propose simple modifications to improve the current point-particle models used in Euler-Lagrange simulations of shock interacting with a bed of particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

β -Technetium: An allotrope with a nonstandard volume-pressure relationship

In this work, we report the synthesis and structure of the second allotrope of technetium, β-Tc. Transformative pathways are accessed at extreme conditions using the laser-heated diamond anvil cell and confirmed with in situ synchrotron x-ray diffraction and Raman spectroscopy. βTc is fully recoverable to ambient conditions, although counter to our DFT calculations predicting a face-centered-cubic lattice, we observe a tetragonal structure (I4/mmm) that exhibits further tetragonal distortion with pressure. β-Tc has an expanded volume relative to the hcp ground state phase, that when doped with nitrogen has an unexpected volume lowering. Such anomalous behavior is possibly indicative of a rare electronic phase transition in a 4d element.

36 MATERIALS SCIENCE↗

Multivariate volume visualization through dynamic projections

We propose a multivariate volume visualization framework that tightly couples dynamic projections with a high-dimensional transfer function design for interactive volume visualization. We assume that the complex, high-dimensional data in the attribute space can be well-represented through a collection of low-dimensional linear subspaces, and embed the data points in a variety of 2D views created as projections onto these subspaces. Through dynamic projections, we present animated transitions between different views to help the user navigate and explore the attribute space for effective transfer function design. Our framework not only provides a more intuitive understanding of the attribute space but also allows the design of the transfer function under multiple dynamic views, which is more flexible than being restricted to a single static view of the data. For large volumetric datasets, we maintain interactivity during the transfer function design via intelligent sampling and scalable clustering. As a result, using examples in combustion and climate simulations, we demonstrate how our framework can be used to visualize interesting structures in the volumetric space.

97 MATHEMATICS AND COMPUTING↗

Evaluation of large volume yeast interfering RNA lure-and-kill ovitraps for attraction and control of Aedes mosquitoes

Aedes mosquitoes (Diptera: Culicidae), principle vectors of several arboviruses, typically lay eggs in man-made water-filled containers located near human dwellings. Given the widespread emergence of insecticide resistance, stable and biofriendly alternatives for mosquito larviciding are needed. Laboratory studies have demonstrated that inactivated yeast interfering RNA tablets targeting key larval developmental genes can be used to facilitate effective larvicidal activity while also promoting selective gravid female oviposition behaviour. In this work, we examined the efficacy of transferring this technology toward development of lure-and-kill ovitraps targeting Aedes aegypti (L.) and Aedes albopictus (Skuse) female mosquitoes. Insectary, simulated field and semi-field experiments demonstrated that two mosquito-specific yeast interfering RNA pesticides induce high levels of mortality among larvae of both species in treated large volume containers. Small-scale field trials conducted in Trinidad, West Indies demonstrated that large volume ovitrap containers baited with inactivated yeast tablets lure significantly more gravid females than traps containing only water and were highly attractive to both A. aegypti and A. albopictus females. Finally, these studies indicate that development of biorational yeast interfering RNA-baited ovitraps may represent a new tool for control of Aedes mosquitoes, including deployment in existing lure-and-kill ovitrap technologies or traditional container larviciding programs.

59 BASIC BIOLOGICAL SCIENCES↗

Numerical Study of Liquid Piston Compression Using Large-Eddy Simulation and Volume-of-Fluid Approach

Efforts to increase the efficiency of residential and commercial air conditioners and heat pumps have demonstrated that the compressor accounts for most of the system’s electrical energy usage. Therefore, the efficiency of this component should be improved to reduce its energy usage. The US Department of Energy’s Oak Ridge National Laboratory developed a near-isothermal liquid piston compressor (LPC) that uses propylene glycol (PG) to compress CO2. This report presents numerical studies of the LPC in which the compression chamber fills with injected PG from the bottom inlet. Numerical simulations were performed using the large-eddy simulation (LES) with the wall-adapting local eddy-viscosity (WALE) subgrid-scale model coupled with the multiphase volume-of-fluid (VOF) model to simulate the transient interface between gas and liquid and to capture the heat and mass transfer within the compression chamber. In this effort, effects of boundary conditions applied to the LES-VOF calculations (e.g., no wall, an adiabatic wall, and a wall with a heat flux subscribed) to the overall pressure and temperature of CO2 gas as well as the transient evolution of flow and heat transfer evolution within the compression chamber are investigated and discussed. It was found that the LES calculation with no wall have shown no dynamical flow patterns and the volume-averaged temperature of CO2 increased from 305 to 392.7 K, while LES calculations with a constant wall temperature or a wall heat flux had similar increases of CO2 temperatures. Results of LES simulation using a wall heat flux showed different stages in the compression process and revealed dynamical formation and interaction of CO2 gas layers and circulation flow patterns within the chamber that contribute to the overall heat transfer between the solid wall, gas, and liquid surface in the compressor.

Nguyen, Thien D.↗

Semiautomatic technique for defining the internal gross tumor volume of lung tumors close to liver/spleen cupola by 4D-CT

Purpose: It has been shown that in cases of lung tumors close to the liver cupola, the four dimensional (4D)-CT postprocessing maximum intensity projection (MIP) algorithm does not fully recover the radiotherapy internal gross tumor volume (IGTV). In this work, a semiautomatic technique was evaluated by which the residual IGTV that was not included into the IGTV by MIP algorithm was actually added. Methods: A moving phantom and five selected patients were considered. The various IGTVs produced by the semiautomatic approach were compared to those generated by 4D-CT manual contouring. Results: In all cases, the radiation oncologist qualitatively concurred with the semiautomatic IGTV. A quantitative difference in volume of 2.6% was found in the phantom study, whereas a mean difference of 0.1{+-}4.6% was obtained in the patient studies. Conclusions: A semiautomatic technique to include the residual part of IGTV covered by liver/spleen cupola when using MIP algorithm was validated on phantom and on selected patients, revealing the possibility of defining the IGTV for patients with lesions located near liver/spleen cupola by performing only the contours on the MIP series.

60 APPLIED LIFE SCIENCES↗

Can volumetric modulated arc therapy with flattening filter free beams play a role in stereotactic body radiotherapy for liver lesions? A volume-based analysis

Purpose: To compare volumetric modulated arc therapy with flattening filter free (FFF) and flattening filter (FF) beams in patients with hepatic metastases subject to hypofractionated radiotherapy (RT). Methods: A planning study on 13 virtual lesions of increasing volume was performed. Two single arc plans were optimized with the RapidArc technique using either FFF or FF beams. A second planning study was performed on ten patients treated for liver metastases to validate conclusions. In all cases, a dose of 75 Gy in 3 fractions was prescribed to the planning target volume (PTV) and plans were evaluated in terms of coverage, homogeneity, conformity, mean dose to healthy liver and to healthy tissue. For each parameter, results were expressed in relative terms as the percentage ratio between FFF and FF data. Results: In terms of PTV coverage, conformity index favored FFF for targets of intermediate size while FF resulted more suitable for small (<100 cm{sup 3}) and large (>300 cm{sup 3}) targets. Plans optimized with FFF beams resulted in increased sparing of healthy tissue in {approx_equal}85% of cases. Despite the qualitative results, no statistically significant differences were found between FFF and FF results. Plans optimized with un-flattened beams resulted in higher average MU/Gy than plans with FF beams. A remarkable and significant difference was observed in the beam-on time (BOT) needed to deliver plans. The BOT for FF plans was 8.2 {+-} 1.0 min; for FFF plans BOT was 2.2 {+-} 0.2 min. Conclusions: RapidArc plans optimized using FFF were dosimetrically equivalent to those optimized using FF beams, showing the feasibility of SBRT treatments with FFF beams. Some improvement in healthy tissue sparing was observed when using the FFF modality due to the different beam's profile. The main advantage was a considerable reduction of beam-on time, relevant for SBRT techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Visibility of microcalcification clusters and masses in breast tomosynthesis image volumes and digital mammography: A 4AFC human observer study

Purpose: To investigate the visibility of simulated lesions in digital breast tomosynthesis (BT) image volumes compared with 2D digital mammography (DM). Methods: Simulated lesions (masses and microcalcifications) were added to images of the same women acquired on a DM system (Mammomat Novation, Siemens) and a BT prototype. The same beam quality was used for the DM and BT acquisitions. The total absorbed dose resulting from a 25-projection BT acquisition and reconstruction (BT{sub 25}) was approximately twice that of a single DM view. By excluding every other projection image from the reconstruction (BT{sub 13}), approximately the same dose as in DM was effected. Simulated microcalcifications were digitally added with varying contrast to the DM and BT images. Simulated masses with 8 mm diameter were also added to BT images. A series of 4-alternative forced choice (4AFC) human observer experiments were conducted. Four medical physicists participated in all experiments, each consisting of 60 trials per experimental condition. The observers interpreted the BT image volumes in cine-mode at a fixed image sequence speed. The required threshold contrast (S{sub t}) to achieve a detectability index (d') of 2.5 (i.e., 92.5% correct decisions) was determined. Results: The S{sub t} for mass detection in DM was approximately a factor of 2 higher than required in BT indicating that the detection of masses was improved under BT conditions compared to DM. S{sub t} for microcalcification detection was higher for BT than for DM at both BT dose levels (BT{sub 25} and BT{sub 13}), with a statistically significant difference in S{sub t} between DM and BT{sub 13}. These results indicate a dose-dependent decrease in detection performance in BT for detection of microcalcifications. Conclusions: In agreement with previous investigations, masses of size 8 mm can be detected with less contrast in BT than in DM indicating improved detection performance for BT. However, for the investigated microcalcifications, the results of this study indicate potentially worse performance for BT than for DM at the same dose level.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of cold walls on PET image quantification and volume segmentation: A phantom study

Purpose: Commercially available fillable plastic inserts used in positron emission tomography phantoms usually have thick plastic walls, separating their content from the background activity. These “cold” walls can modify the intensity values of neighboring active regions due to the partial volume effect, resulting in errors in the estimation of standardized uptake values. Numerous papers suggest that this is an issue for phantom work simulating tumor tissue, quality control, and calibration work. This study aims to investigate the influence of the cold plastic wall thickness on the quantification of 18F-fluorodeoxyglucose on the image activity recovery and on the performance of advanced automatic segmentation algorithms for the delineation of active regions delimited by plastic walls.Methods: A commercial set of six spheres of different diameters was replicated using a manufacturing technique which achieves a reduction in plastic walls thickness of up to 90%, while keeping the same internal volume. Both sets of thin- and thick-wall inserts were imaged simultaneously in a custom phantom for six different tumor-to-background ratios. Intensity values were compared in terms of mean and maximum standardized uptake values (SUVs) in the spheres and mean SUV of the hottest 1 ml region (SUV{sub max}, SUV{sub mean}, and SUV{sub peak}). The recovery coefficient (RC) was also derived for each sphere. The results were compared against the values predicted by a theoretical model of the PET-intensity profiles for the same tumor-to-background ratios (TBRs), sphere sizes, and wall thicknesses. In addition, ten automatic segmentation methods, written in house, were applied to both thin- and thick-wall inserts. The contours obtained were compared to computed tomography derived gold standard (“ground truth”), using five different accuracy metrics.Results: The authors' results showed that thin-wall inserts achieved significantly higher SUV{sub mean}, SUV{sub max}, and RC values (up to 25%, 16%, and 25% higher, respectively) compared to thick-wall inserts, which was in agreement with the theory. This effect decreased with increasing sphere size and TBR, and resulted in substantial (>5%) differences between thin- and thick-wall inserts for spheres up to 30 mm diameter and TBR up to 4. Thinner plastic walls were also shown to significantly improve the delineation accuracy for the majority of the segmentation methods tested, by increasing the proportion of lesion voxels detected, although the errors in image quantification remained non-negligible.Conclusions: This study quantified the significant effect of a 90% reduction in the thickness of insert walls on SUV quantification and PET-based boundary detection. Mean SUVs inside the inserts and recovery coefficients were particularly affected by the presence of thick cold walls, as predicted by a theoretical approach. The accuracy of some delineation algorithms was also significantly improved by the introduction of thin wall inserts instead of thick wall inserts. This study demonstrates the risk of errors deriving from the use of cold wall inserts to assess and compare the performance of PET segmentation methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-192: Verification of 4D-MRI Internal Target Volume Using Cine MRI

Purpose: To investigate the accuracy of 4D-MRI in determining the Internal Target Volume (ITV) used in radiation oncology treatment planning of liver cancers. Cine MRI is used as the standard baseline in establishing the feasibility and accuracy of 4D-MRI tumor motion within the liver. Methods: IRB approval was obtained for this retrospective study. Analysis was performed on MR images from four patients receiving external beam radiation therapy for liver cancer at our institution. Eligible patients received both Cine and 4D-MRI scans before treatment. Cine images were acquired sagittally in real time at a slice bisecting the tumor, while 4D images were acquired volumetrically. Cine MR DICOM headers were manipulated such that each respiratory frame was assigned a unique slice location. This approach permitted the treatment planning system (Eclipse, Varian Medical Systems) to recognize a complete respiratory cycle as a “volume”, where the gross tumor was contoured temporally. Software was developed to calculate the union of all frame contours in the structure set, resulting in the corresponding plane of the ITV projecting through the middle of the tumor, defined as the Internal Target Area (ITA). This was repeated for 4D-MRI, at the corresponding slice location, allowing a direct comparison of ITAs obtained from each modality. Results: Four patients have been analyzed. ITAs contoured from 4D-MRI correlate with contours from Cine MRI. The mean error of 4D values relative to Cine values is 7.67 +/− 2.55 %. No single ITA contoured from 4D-MRI demonstrated more than 10.5 % error compared to its Cine MRI counterpart. Conclusion: Motion management is a significant aspect of treatment planning within dynamic environments such as the liver, where diaphragmatic and cardiac activity influence plan accuracy. This small pilot study suggests that 4D-MRI based ITA measurements agree with Cine MRI based measurements, an important step towards clinical implementation. NIH 1R21CA165384-01A1.

60 APPLIED LIFE SCIENCES↗

SU-F-BRD-14: The Effect of Radiation-Induced Esophageal Swelling On Dose-Volume Histograms

Purpose: Acute esophagitis results in esophageal swelling. Here we evaluate the effect of this response on DVH metrics calculated throughout the course of radiation therapy. Methods: Twenty-nine NSCLC patients were identified who received weekly CT imaging, and varying esophagitis grades (11 grade0 patients, 12 grade2 patients, 6 grade3 patients), using CTCAE scoring criteria. Deformable image registration was used to map the planning esophagus contour to the weekly CT images. Treatment plans were recalculated on each weekly 4DCT and DVH metrics for the esophagus were compared to the delivered treatment plan. DVH metrics were also extracted for esophagus planning-at-risk volumes (PRV) with 1–3mm uniform expansions. Results: The esophagus V50 increased as the treatment progressed by 2.3±0.7cc and 9.0±1.1cc, for the grade 0 and grade 2/3 patients, respectively. The mean esophageal dose (MED) increased by 3.5±0.9Gy, and 8.0±1.1Gy for the grade 0 and grade 2/3 patients, respectively. In some cases where the planned V50 was similar, it remained the same at the end of treatment for grade 0 cases, but increased for higher grade cases. These apparent changes in delivered dose, as expressed by the DVH, are mostly attributed to volume changes in the regions of esophagitis. In addition, portions of the esophagus of some patients moved into highdose regions. The 2mm PRV was able to account for these differences in all but 1 of the 18 G2/3 patients. The 1mm PRV produced the closest DVH metrics calculated from the average weekly plans compared to the true treatment plan. Conclusion: Esophagus radiation response affects DVH parameters throughout treatment, especially patients with high toxicity. This effect must be considered when comparing DVHs calculated using daily IGRT CT images with those from the original planning CT (e.g. for adaptive planning). Adding a margin to the esophagus can account for variation in DVH metrics.

60 APPLIED LIFE SCIENCES↗

TH-A-18C-11: An Investigation of KV CBCT Image Quality and Dose Reduction for Volume-Of-Interest Imaging Using Dynamic Collimation

Purpose: The focus of this work was to investigate the improvements in image quality and dose reduction for volume-of-interest (VOI) kV-CBCT using dynamic collimation. Methods: A prototype iris aperture was used to track a VOI during a CBCT acquisition. The current aperture design is capable of one-dimensional translation as a function of gantry angle and dynamic adjustment of the iris radius. The aperture occupies the location of the bow-tie filter on a Varian OBI system. CBCT and planar image quality was investigated as a function of aperture radius, while maintaining the same dose to the VOI, for a 20 cm diameter cylindrical water phantom with a 9 mm diameter bone insert centered on isocenter. Corresponding scatter-to-primary ratios (SPR) were determined at the detector plane with Monte Carlo simulation using EGSnrc. Dose distributions for various anatomical sites were modeled using a dynamic BEAMnrc library and DOSXYZnrc. The resulting VOI dose distributions were compared to full-field distributions. Results: SPR was reduced by a factor of 8.4 when decreasing iris diameter from 21.2 cm to 2.4 cm (at isocenter). Similarly, this change in iris diameter corresponds to a factor increase of approximately 1.4 and 1.5 in image contrast for CBCT and planar images, respectively, and similarly a factor decrease in image noise of approximately 1.7 and 1.5. This results in a measured gain in contrast-to-noise ratio of a factor of approximately 2.3 for both CBCT and planar images. Depending upon the anatomical site, dose was reduced to 10%–70% of the full field value along the central axis plane and down to 2% along the axial planes, while maintaining the same dose to the VOI compared to full-field techniques. Conclusion: The presented VOI technique offers improved image quality for image-guided radiotherapy while sparing the surrounding volume of unnecessary dose compared to full-field techniques.

60 APPLIED LIFE SCIENCES↗

SU-C-BRE-02: BED Vs. Local Control: Radiobiological Effect of Tumor Volume in Monte Carlo (MC) Lung SBRT Planning

Purpose: SBRT with hypofractionated dose schemata has emerged a compelling treatment modality for medically inoperable early stage lung cancer patients. It requires more accurate dose calculation and treatment delivery technique. This report presents the relationship between tumor control probability(TCP) and size-adjusted biological effective dose(sBED) of tumor volume for MC lung SBRT patients. Methods: Fifteen patients who were treated with MC-based lung SBRT to 50Gy in 5 fractions to PTVV100%=95% were studied. ITVs were delineated on MIP images of 4DCT-scans. PTVs diameter(ITV+5mm margins) ranged from 2.7–4.9cm (mean 3.7cm). Plans were generated using non-coplanar conformal arcs/beams using iPlan XVMC algorithm (BrainLABiPlan ver.4.1.2) for Novalis-TX with HD-MLCs and 6MVSRS(1000MU/min) mode, following RTOG-0813 dosimetric guidelines. To understand the known uncertainties of conventional heterogeneities-corrected/uncorrected pencil beam (PBhete/ PB-homo) algorithms, dose distributions were re-calculated with PBhete/ PB-homo using same beam configurations, MLCs and monitor units. Biologically effective dose(BED10) was computed using LQ-model with α/β=10Gy for meanPTV and meanITV. BED10-c*L, gave size-adjusted BED(sBED), where c=10Gy/cm and L=PTV diameter in centimeter. The TCP model was adopted from Ohri et al.(IJROBP, 2012): TCP = exp[sBEDTCD50]/ k /(1.0 + exp[sBED-TCD50]/k), where k=31Gy corresponding to TCD50=0Gy; and more realistic MC-based TCP was computed for PTV(V99%). Results: Mean PTV PB-hete TCP value was 6% higher, but, mean PTV PB-homo TCP value was 4% lower compared to mean PTV MC TCP. Mean ITV PB-hete/PB-homo TCP values were comparable (within ±3.0%) to mean ITV MC TCP. The mean PTV(V99%)had BED10=90.9±3.7%(median=92.2%),sBED=54.1±8.2%(median=53.5%) corresponding to mean MC TCP value of 84.8±3.3%(median=84.9%) at 2- year local control. Conclusion: The TCP model which incorporates BED10 and tumor diameter indicates that radiobiological effect of target volume and dose calculation algorithm significantly affects TCP for lung SBRT patients. Dose calculation using MC-based algorithm is more realistic with tissue heterogeneities and is routinely performed in our clinic. Patients will be followed up to determine whether TCP prediction correlate clinical outcomes.

60 APPLIED LIFE SCIENCES↗