Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Upgrade”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

High-speed imaging upgrade for a standard sample scanning atomic force microscope using small cantilevers

We present an atomic force microscope (AFM) head for optical beam deflection on small cantilevers. Our AFM head is designed to be small in size, easily integrated into a commercial AFM system, and has a modular architecture facilitating exchange of the optical and electronic assemblies. We present two different designs for both the optical beam deflection and the electronic readout systems, and evaluate their performance. Using small cantilevers with our AFM head on an otherwise unmodified commercial AFM system, we are able to take tapping mode images approximately 5–10 times faster compared to the same AFM system using large cantilevers. By using additional scanner turnaround resonance compensation and a controller designed for high-speed AFM imaging, we show tapping mode imaging of lipid bilayers at line scan rates of 100–500 Hz for scan areas of several micrometers in size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Forward fitting of experimental data from a NE213 neutron detector installed with the magnetic proton recoil upgraded spectrometer at JET

In this paper, we present the results obtained from the data analysis of neutron spectra measured with a NE213 liquid scintillator at JET. We calculated the neutron response matrix of the instrument combining MCNPX simulations, a generic proton light output function measured with another detector and the fit of data from ohmic pulses. For the analysis, we selected a set of pulses with neutral beam injection heating (NBI) only and we applied a forward fitting procedure of modeled spectral components to extract the fraction of thermal neutron emission. The results showed the same trend of the ones obtained with the dedicated spectrometer TOFOR, even though the values from the NE213 analysis were systematically higher. This discrepancy is probably due to the different lines of sight of the two spectrometers (tangential for the NE213, vertical for TOFOR). The uncertainties on the thermal fraction estimates were from 4 to 7 times higher than the ones from the TOFOR analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A brief note on the magnecule order parameter upgrade hypothesis

In this short remark, we report on recent hypothetical work that aims to equip Santilli’s magnecule model with topological deformation order parameters (OP) of fractional statistics to define a preliminary set of wavepacket wavefunctions for the electron toroidal polarizations. The primary objective is to increase the representational precision and predictive accuracy of the magnecule model by exemplifying the fluidic characteristics for direct industrial application. In particular, the OPs are deployed to encode the spontaneous superfluidic gauge symmetry breaking (which may be restored at the iso-topic level) and correlated with Leggett’s superfluid B phases to establish a long range constraint for the wavefunctions. These new, developing, theoretical results may be significant because the OP configuration arms us with an extra degree of freedom for encoding a magnecule’s states and transitions, which may reveal further insight into the underlying physical mechanisms and features associated with these state-of-the-art magnecular bonds.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of thermal helium beam and line-ratio fast diagnostic on the National Spherical Torus Experiment-Upgrade

A 1-D kinetic collisional radiative model (CRM) with state-of-the-art atomic data is developed and employed to simulate line emission to evaluate the Thermal Helium Beam (THB) diagnostic on NSTX-U. This diagnostic is currently in operation on RFX-mod, and it is proposed to be installed on NSTX-U. The THB system uses the intensity ratios of neutral helium lines 667.8, 706.5, and 728.1 nm to derive electron temperature (eV ) and density (cm –3 ) profiles. The purpose of the present analysis is to evaluate the applications of this diagnostic for determining fast (~4 μs) electron temperature and density radial profiles on the scrape-off layer (SOL) and edge regions of NSTX-U that are needed in turbulence studies. The diagnostic is limited by the level of detection of the 728.1 nm line, which is the weakest of the three. In conclusion, this study will also aid in future design of a similar 2-D diagnostic systems on the divertor.

97 MATHEMATICS AND COMPUTING↗

CHESS upgrade with compact undulator magnets: Operating experience and first results

In November 2014 two in-air 1.5 m CHESS Compact Undulator (CCU) magnets built by KYMA S.R.l. were installed in Cornell Electron Storage Ring (CESR) in canted arrangement and after few days of commissioning their regular operation started. CCU magnets are compact, lightweight and cost efficient devices. They have very stable magnetic field integrals independent of deflection parameter value. This feature greatly simplifies the storage ring operation. The CCU concept was developed at Cornell in 2011 and the first 1 m in-vacuum CCU magnet was beam-tested in 2012. The article presents CCU concept and some details of the design. It describes also the layout of CCUs installation in CESR, their performance and characteristics. The current status of operation and future plans are discussed as well. Presently, at CHESS two CCU magnets provide radiation for 5 out of 11 experimental stations.

43 PARTICLE ACCELERATORS↗

Status of the GERDA Phase II upgrade

The GERDA experiment is designed to search for neutrinoless double beta (0νββ) decay of {sup 76}Ge. In Phase I of the experiment a background index of 10{sup −2} cts/(keV·kg·yr) was reached. A lower limit on the half-life of the 0νββ decay of {sup 76}Ge was set to 2.1·10{sup 25} yr (at 90% C.L.). The aim of Phase II is to reach a sensitivity of the half-life of about 10{sup 26} yr. To increase the exposure thirty new Broad Energy Germanium (BEGe) detectors have been produced. These detectors are distinct for their improved energy resolution and enhanced pulse shape discrimination of signal from background events. Further background reduction will be reached by a light instrumentation to read out argon scintillation light. In April 2015 the light instrumentation together with eight BEGe detectors has been successfully deployed in the GERDA cryostat. In a commissioning run it was shown that two of the major background components, external γ-rays from {sup 214}Bi and {sup 208}Tl decays, were suppressed up to two orders of magnitude. We are confident to reach a background index of 10{sup −3} cts/(keV·kg·yr) which is the design goal for GERDA Phase II.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A new H{sub 2}{sup +} source: Conceptual study and experimental test of an upgraded version of the VIS—Versatile ion source

The versatile ion source is an off-resonance microwave discharge ion source which produces a slightly overdense plasma at 2.45 GHz of pumping wave frequency extracting more than 60 mA proton beams and 50 mA He{sup +} beams. DAEδALUS and IsoDAR experiments require high intensities for H{sub 2}{sup +} beams to be accelerated by high power cyclotrons for neutrinos generation. In order to fulfill the new requirements, a new plasma chamber and injection system has been designed and manufactured for increasing the H{sub 2}{sup +} beam intensity. In this paper the studies for the increasing of the H{sub 2}{sup +}/p ratio and for the design of the new plasma chamber and injection system will be shown and discussed together with the experimental tests carried out at Istituto Nazionale di Fisica Nucleare-Laboratori Nazionali del Sud (INFN-LNS) and at Best Cyclotron Systems test-bench in Vancouver, Canada.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgraded flowing liquid lithium limiter for improving Li coverage uniformity and erosion resistance in EAST device

In this paper, we report on design and technology improvements for a flowing liquid lithium (FLiLi) limiter inserted into auxiliary heated discharges in the experimental advanced superconducting tokamak device. In order to enhance Li coverage uniformity and erosion resistance, a new liquid Li distributor with homogenous channels was implemented. In addition, two independent electromagnetic pumps and a new horizontal capillary structure contributed to an improvement in the observed Li flow uniformity (from 30% in the previous FLiLi design to >80% in this FLiLi design). To improve limiter surface erosion resistance, hot isostatic press technology was applied, which improved the thermal contact between thin stainless steel protective layers covering the Cu heat sink. The thickness of the stainless steel layer was increased from 0.1 mm to 0.5 mm, which also helped macroscopic erosion resilience. Finally, despite the high auxiliary heating power up to 4.5 MW, no Li bursts were recorded from FLiLi, underscoring the improved performance of this new design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Upgrades to the in-vessel calibration light source on JET

Since 2010, an in-vessel calibration light source (ICLS) has been used periodically on JET to calibrate a range of diagnostics at UV, visible, and IR wavelengths. During shutdowns, the ICLS (which is essentially an integrating sphere) is positioned within the vacuum vessel by the remote handling (RH) system. Following the 2013 calibration runs, several changes were made to improve the efficiency and quality of the calibrations. Among these was the replacement of a 20 m “umbilical” cable which carried power and other electrical signals through a vessel port to/from a control cubicle. A lightweight 2 m cable now plugs directly into a single connector on the RH manipulator system, greatly reducing the time required for deployment and improving operational flexibility; e.g., the vessel access “floor” no longer needs to be installed. This change also means the system would be compatible with calibrations after a high neutron-fluence period of operation. An on-board micro-spectrometer now allows for real-time verification of the emitted spectrum. Finally, new “baffles” were designed and installed within the integrating sphere itself, greatly improving the spectral radiance uniformity at non-normal viewing angles (necessary due to orientation uncertainties with the RH system).

Conway, N. J.↗

Utilization of O-X-B mode conversion of 28 GHz microwaves to heat core electrons in the upgraded Proto-MPEX

The magnetic geometry of the Prototype Material Plasma Exposure eXperiment (Proto-MPEX) was recently altered to enable more effective utilization of 28 GHz microwave auxiliary power, specifically: (1) to heat plasma electrons in the radial core of the device and (2) to deliver the heated plasma to the target plate of the device. To achieve this goal, the microwave launcher geometry and placement were significantly re-engineered, guided by previous experimental results and computational modeling. The core electron temperature in the launcher region is observed to increase from 3 eV to 11 eV with 30 kW of auxiliary power after the improvements, and an increase from 3 eV to 6 eV is concurrently measured in the target region (~1 m from the launcher) at electron density above O-mode cutoff. Radially resolved measurements in the launcher region exhibit a strong dependence on the magnetic geometry. The conclusions of a magnetic field scan reinforce the effectiveness of the intended O-X-B mode conversion scenario that is currently planned for microwave heating of the Material Plasma Exposure eXperiment (MPEX).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Upgrading the LANSCE accelerator with a SNS RF-driven H− ion source

The LANSCE accelerator is currently powered by a filament-driven, biased converter-type H− ion source that operates at 10%, the highest plasma duty factor for this type of source, using only ∼2.2 SCCM of H2. The ion source needs to be replaced every 4 weeks, which takes up to 4 days. The measured negative beam current of 12–16 mA falls below the desired 24 mA acceptance of the LANCSE accelerator. The SNS (Spallation Neutron Source) RF-driven, H− ion source injects ∼50 mA of H− beam into the SNS accelerator at 60 Hz with a 6% duty factor and an availability of >99.5% but requires ∼30 SCCM of H2. Up to 7 A h of H− have been produced during the 14-weeks-long source service cycles, which is unprecedented for small emittance, high-current, pulsed H− ion sources. The emittance of the SNS source is slightly smaller than the emittance of the LANSCE source. The SNS source also features unrivaled low Cs consumption and can be installed and started up in <12 h. LANSCE and SNS are working toward the use of SNS H− ion sources on the LANSCE accelerator because they could (a) fill the LANSCE accelerator to its capacity, (b) decrease the source replacement time by a factor of up to 7, and (c) increase source lifetime by a factor of about 4. This paper discusses some of the challenges that emerge when trying to match a different H− source into an existing injector with significantly different characteristics and operating regimes.

Stockli, Martin P.↗

Upgrades and redesign of the National Ignition Facility’s soft x-ray opacity spectrometer (OpSpec)

The soft x-ray Opacity Spectrometer (OpSpec) used on the National Ignition Facility (NIF) has recently incorporated an elliptically shaped crystal. The original OpSpec used two convex cylindrical crystals for time-integrated measurements of point-projection spectra from 540 to 2100 eV. However, with the convex geometry, the low-energy portion of the spectrum suffered from high backgrounds due to scattered x-rays as well as reflections from alternate crystal planes. An elliptically shaped crystal allows an acceptance aperture at the crossover focus between the crystal and the detector, which reduces background and eliminates nearly all reflections from alternate crystal planes. The current elliptical design is an improvement from the convex cylindrical design but has a usable energy range from 900 to 2100 eV. In addition, OpSpec is currently used on 18 NIF shots/year, in which both crystals are typically damaged beyond reuse, so efficient production of 36 crystals/year is required. Design efforts to improve the existing system focus on mounting reliability, reducing crystal strain to increase survivability between mounting and shot time, and extending the energy range of the instrument down to 520 eV. The elliptical design, results, and future options are presented.

Wallace, M. S. (ORCID:0000000310871216)↗

Ray-tracing analysis for cross-polarization scattering diagnostic on MAST-upgrade spherical tokamak

A combined Doppler backscattering/cross-polarization scattering (DBS/CPS) system is being deployed on MAST-U for simultaneous measurements of local density turbulence, turbulence flows, and magnetic turbulence. In this design, CPS shares the probing beam with the DBS and uses a separate parallel-viewing receiver system. In this study, we utilize a modified GENRAY 3D ray-tracing code to simulate the propagation of the probing and scattered beams. The contributions of different scattering locations along the entire beam trajectories are considered, and the corresponding local B̃ wavenumbers are estimated using the wavevector matching criterion. The wavenumber ranges of the local B̃ that are detectable to the CPS system are explored for simulated L- and H-mode plasmas.

Hong, R. (ORCID:0000000347508015)↗

Installation of a solid state neutral particle analyzer array on mega ampere spherical tokamak upgrade

A compact solid state neutral particle analyzer (SSNPA) diagnostic, previously installed at NSTX-U, has been moved to MAST-U and successfully operated in the first physics campaign (MU01). The SSNPA operates by detecting the flux of fast neutral particles produced by charge exchange (CX) reactions to diagnose the fast ion distribution. The diagnostic consists of three 16-channel sensors, which provide a radial view of the plasma and have a sightline intersection with the South–South neutral beam line. From this radial geometry, active CX signals from mostly trapped particles are observed. Each channel has a spatial resolution of 3–4 cm, a temporal resolution of 200 kHz, and an average pitch angle resolution of a few degrees. The three-sensor configuration allows for coarse energy resolution of the CX signals; each sensor sees similar sightlines but different filter thicknesses alter the energy cutoffs by known amounts. Experimental data show that all channels are collecting data as intended. The signal to noise ratio is typically around 15. Preliminary data analysis shows a correlation between the SSNPA signal and magnetohydrodynamic activity in the plasma as expected.

Instruments & Instrumentation↗