Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Comparison of fiber-optic distributed temperature sensing and high-sensitivity sensor spatial surveying of stream temperature

Measuring surface water temperature spatial variability is needed to estimate the interaction between surface water and groundwater, evaluate fish habitat and thermal inertia, and to estimate streamflow frequency and duration. Fiber optic distributed temperature sensing (FO-DTS) has been used in rivers and lakes, providing high-resolution and sensitive temperature monitoring over large temporal and spatial scales. However, in streams with cobbly or bedrock-lined streambeds and variable bathymetry, use of FO-DTS to measure temperature close to the surface water and groundwater interface can be challenging if even feasible. FO-DTS can also be costly, involve difficult installations, and require an advanced understanding of the technology, calibration, and data processing. In this study, we compared FO-DTS stream temperature survey results to an alternative temperature survey method employing a towed transect of high-resolution temperature loggers spaced at 1-m and transported in the stream along the study reach, to measure the spatial distribution of stream-water temperature in East Fork Poplar Creek near Oak Ridge, Tennessee, USA. We assessed the applicability and limitations of the two methods, and quantitatively compared in-situ temperature survey results measured simultaneously with each method. Regression results showed strong temporal and spatial correlation between the two methods. Differences were only elevated near the stream banks in areas that were coincident with correlation slope deviations from unity, which was attributed to shallower water and lower data density. Kriging standard errors were also low at channel center with minor increases near the stream banks. Furthermore, the results suggested that the array of the individual temperature sensors can provide a practical alternative to FO-DTS for thermal characterization of surface water, providing slightly lower spatial and temporal resolution, but with higher accuracy of temperature measurement, with greater simplicity, and with a broader range of conditions where it may be applied.

54 ENVIRONMENTAL SCIENCES↗

Reannealed Fiber Bragg Gratings Demonstrated High Repeatability in Temperature Measurements

Fiber Bragg gratings (FBGs) are formed by periodic variations of the refractive index of an optical fiber. These periodic variations allow an FBG to act as an embedded optical filter, passing the majority of light propagating through a fiber while reflecting back a narrow band of the incident light. The peak reflected wavelength of the FBG is known as the Bragg wavelength. Since the period and width of the refractive index variation in the fiber determines the wavelengths that are transmitted and reflected by the grating, any force acting on the fiber that alters the physical structure of the grating will change the wavelengths that are transmitted and reflected by it. Both thermal and mechanical forces acting on the grating will alter its physical characteristics, allowing the FBG sensor to detect both the temperature variations and the physical stresses and strains placed upon it. This ability to sense multiple physical forces makes the FBG a versatile sensor. To assess the feasibility of using Bragg gratings as temperature sensors for propulsion applications, researchers at the NASA Glenn Research Center evaluated the performance of Bragg gratings at elevated temperatures for up to 300 C. For these purposes, commercially available polyimide-coated high-temperature gratings were used that were annealed by the manufacturer to 300 C. To assure the most thermally stable gratings at the operating temperatures, we reannealed the gratings to 400 C at a very slow rate for 12 to 24 hr until their reflected optical powers were stabilized. The reannealed gratings were then subjected to periodic thermal cycling from room temperature to 300 C, and their peak reflected wavelengths were monitored. The setup shown is used for reannealing and thermal cycling the FBGs. Signals from the photodetectors and the spectrum analyzer were fed into a computer equipped with LabVIEW software. The software synchronously monitored the oven/furnace temperature and the optical spectrum analyzer as well as processed the data. Experimental results presented in the following graph show typical wavelength versus temperature dependence of a reannealed FBG through six thermal cycles (80 hr). The average standard deviation of the temperature-to-wavelength relationship ranged from 1.86 to 2.92 C over the six thermal cycles each grating was subjected to. This is an error of less than 1.0 percent of full scale throughout the entire evaluation temperature range from ambient to 300 C.

Adamovsky, Grigory↗

On-Orbit Spatial Performance Characterization for Thermal Infrared Imagers of Landsat 7, 8, and 9, ECOSTRESS and CTI

In this analysis of the spatial resolving power of thermal imagery products we focus on four satellite instruments that are used in research and applications, for example to monitor land surface temperature and derive evapotranspiration. These are thermal imagers on Landsat 7, Landsat 8, and Landsat 9, as well as the ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS). We compiled sets of close-in-time, day-time images of bridges surrounded by open water bodies, captured by each of the satellite imagers during cloud-free moments. Where possible, we also included some images captured by the Compact Thermal Imager (CTI), a technology demonstrator that was co-located with ECOSTRESS on the International Space Station in 2019. Bridges were found to provide a sufficient thermal contrast with the water surface to quantify the line-spread function of satellite-based thermal products. The full-width-at-half-max of a gaussian beam model fitted to this transect quantifies the on-orbit spatial resolution of different imagers. The results show some loss of spatial resolving power in the final product delivered to end-users as compared to the at-sensor characterization of spatial resolution. For Landsat 7, 8 and 9, the spatial resolution of the thermal bands is 1.5 times the ground sampling distance of 60 m and 100 m respectively. For the ECOSTRESS the difference is up to twice the sampling distance of 78 by 69 m2. Since spatial resolution is a main driver for instrument design it is important to understand and communicate this discrepancy between pre-flight design parameters and the characteristics of the surface imagery delivered to the user community. The goal of this research is to facilitate an improved fusion of current and future satellite observations into harmonized products with superior temporal and spatial characteristics.

thermal infrared↗

Multi-channel electronically scanned cryogenic pressure sensor

A miniature, multi-channel, electronically scanned pressure measuring device uses electrostatically bonded silicon dies in a multielement array. These dies are bonded at specific sites on a glass, prepatterned substrate. Thermal data is multiplexed and recorded on each individual pressure measuring diaphragm. The device functions in a cryogenic environment without the need of heaters to keep the sensor at constant temperatures.

Chapman, John J.↗

Overview of Aqua MODIS 10-year On-orbit Calibration and Performance

Since launch in May 2002, Aqua MODIS has successfully operated for nearly 10 years, continuously collecting global datasets for scientific studies of key parameters of the earth's land, ocean, and atmospheric properties and their changes over time. The quality of these geophysical parameters relies on the input quality of sensor calibrated radiances. MODIS observations are made in 36 spectral bands with wavelengths ranging from visible (VIS) to longwave infrared (LWIR). Its reflective solar bands (RSB) are calibrated using data collected from its on-board solar diffuser and regularly scheduled lunar views. The thermal emissive bands (TEB) are calibrated using an on-board blackbody (BB). The changes in the sensor's spectral and spatial characteristics are monitored by an on-board spectroradiometric calibration assembly (SRCA). This paper presents an overview of Aqua MODIS 10-year on-orbit operation and calibration activities, from launch to present, and summarizes its on-orbit radiometric, spectral, and spatial calibration and characterization performance. In addition, it will illustrate and discuss on-orbit changes in sensor characteristics and corrections applied to continuously maintain the sensor level 1B (L1B) data quality, as well as lessons learned that could benefit future calibration efforts.

Xiong, X.↗

A New Approach to Joining Dissimilar Ceramic Oxides for Chemical Sensors

Conventional joining of dissimilar oxides for sensing electrodes (SE) of chemical sensors has been pivotal to the development of various sensors and is vital to their further development. However, it is shown that the uncertainty (of a fundamental nature) in the properties of dissimilar oxides in SE causes the determination of their sensing characteristics to be ambiguous. Characteristics are different for such controlled parameters as pyrolysis temperature, crystal structure, particle's morphology and size, chemical and phase composition, the coefficient of thermal expansion (CTE), surface architecture, the bulk and surface stoichiometry and type and conductivity of additives. Here, we provide an alternative approach for joining dissimilar metal-oxides for chemical sensors SE. The approach relies on the development of at least one transient liquid oxide phase on the ceramic-SE interface. These results constitute key points relevant to selection oxides for joining, sintering temperatures and heating/cooling temperature rates.

36 MATERIALS SCIENCE↗

Virtual Sensors: Using Data Mining to Efficiently Estimate Spectra

Detecting clouds within a satellite image is essential for retrieving surface geophysical parameters, such as albedo and temperature, from optical and thermal imagery because the retrieval methods tend to be valid for clear skies only. Thus, routine satellite data processing requires reliable automated cloud detection algorithms that are applicable to many surface types. Unfortunately, cloud detection over snow and ice is difficult due to the lack of spectral contrast between clouds and snow. Snow and clouds are both highly reflective in the visible wavelen,ats and often show little contrast in the thermal Infrared. However, at 1.6 microns, the spectral signatures of snow and clouds differ enough to allow improved snow/ice/cloud discrimination. The recent Terra and Aqua Moderate Resolution Imaging Spectro-Radiometer (MODIS) sensors have a channel (channel 6) at 1.6 microns. Presently the most comprehensive, long-term information on surface albedo and temperature over snow- and ice-covered surfaces comes from the Advanced Very High Resolution Radiometer ( AVHRR) sensor that has been providing imagery since July 1981. The earlier AVHRR sensors (e.g. AVHRR/2) did not however have a channel designed for discriminating clouds from snow, such as the 1.6 micron channel available on the more recent AVHRR/3 or the MODIS sensors. In the absence of the 1.6 micron channel, the AVHRR Polar Pathfinder (APP) product performs cloud detection using a combination of time-series analysis and multispectral threshold tests based on the satellite's measuring channels to produce a cloud mask. The method has been found to work reasonably well over sea ice, but not so well over the ice sheets. Thus, improving the cloud mask in the APP dataset would be extremely helpful toward increasing the accuracy of the albedo and temperature retrievals, as well as extending the time-series of albedo and temperature retrievals from the more recent sensors to the historical ones. In this work, we use data mining methods to construct a model of MODIS channel 6 as a function of other channels that are common to both MODIS and AVHRR. The idea is to use the model to generate the equivalent of MODIS channel 6 for AVHRR as a function of the AVHRR equivalents to MODIS channels. We call this a Virtual Sensor because it predicts unmeasured spectra. The goal is to use this virtual channel 6. to yield a cloud mask superior to what is currently used in APP . Our results show that several data mining methods such as multilayer perceptrons (MLPs), ensemble methods (e.g., bagging), and kernel methods (e.g., support vector machines) generate channel 6 for unseen MODIS images with high accuracy. Because the true channel 6 is not available for AVHRR images, we qualitatively assess the virtual channel 6 for several AVHRR images.

Srivastava, Ashok↗

Ultrasonic measurement of temperature distributions in extreme environments: Electrical power plants testing in utility-scale steam generators

Thermal heterogeneities within energy conversion and storage, material processing, nuclear processes, aerospace, and military applications are often inaccessible to characterization by insertion sensors. When sensor deployment is possible, conventional pointwise temperature probes quickly degrade when inserted into harsh environments typical of such processes. We developed spatially-resolved ultrasonic thermometry to noninvasively measure the spatial distributions of thermal properties in such applications, even when sizable thermal gradients are present. Our method divides the path of ultrasonic propagation into segments bound by echogenic features, which create echoes in pulse-echo mode, encoding the information about interior temperature distributions. We use the acquired ultrasonic responses to estimate the internal temperature distributions by solving an inverse problem or concatenating segmental estimates. This work describes the implementation and industrial testing of the developed method at a coal-fired electrical power generation plant. We inserted an echogenically segmented Inconel 625 waveguide into the combustion zone of the utility-scale boiler and continuously acquired ultrasonic data while keeping sensitive components away from the damaging combustion environment. The accuracy of the time-dependent temperature distributions reconstructed from the ultrasonic measurements was comparable to that of thermocouples. The resiliency of ultrasonic thermometry to harsh combustion conditions was far superior to conventional insertion sensors. The measurements obtained during plant operation captured daily steam generation cycles in response to changing customer demand and intermittent contributions of renewable power sources to the power grid. These measurements have revealed new insights into the relationship between the dynamic power generation load and the conditions inside the steam generator. As a result, the successful industrial testing of spatially-resolved ultrasonic thermometry in solids indicates that the developed technology has matured to become an attractive alternative to conventional sensing in solving challenging problems of long-term thermal characterizations in extreme environments.

42 ENGINEERING↗

Glassy carbon formation from pyrolysis of polymeric coatings on fiber-optic sensors

Deploying fiber-optic sensors in nuclear reactors requires a detailed understanding of radiation effects on the fiber materials and the transmitted signals. Previous work has shown large wavelength shifts in the reflected spectra obtained from polymer-coated fiber-optic temperature sensors exposed to high neutron fluences. The sensor drift resulting from these wavelength shifts cannot be explained by radiation effects on fused silica glass. These shifts are hypothesized to be caused by the conversion of the polymeric fiber coating to a glassy carbon via radiolysis and/or pyrolysis and subsequent radiation-induced compaction. Here, thermal degradation of these polymeric coatings was studied to provide insight into the potential origins of the sensor drift phenomenon. Acrylate- and polyimide-coated fibers were heated under various temperatures (250–1300 °C) and environments (oxidative and inert), and the resulting coating products were characterized via mass-loss data, scanning electron microscope imaging, and Raman spectroscopy. Results suggest that the polymer decomposition product of both coating types, at least under inert conditions, is indeed a glassy carbon. Analytical models that account for radiation-induced glassy carbon coating compaction show significant compressive fiber strains and predicted wavelength shifts that agree well with experimental measurements, providing additional evidence that supports the hypothesized origins of the sensor drift.

36 MATERIALS SCIENCE↗

Return to Flight Resource Reel 1 of 2

A video presentation detailing the tests performed on the Space Shuttle Discovery in preparation for its return to flight is shown. The tests include: 1) Reinforced Carbon-Carbon (RCC) Impact Test Article; 2) RCC Foam Impact Testing; 3) Thermal Protection System (TPS) Ice Impact Testing featuring Justin Kerr, Project Engineer; 4) Wing Leading Edge Wireless Sensors featuring Karl Kiefer, President and CEO of Invocon, and Kevin Champaigne of Invocon; 5) TPS Repair Testing KC-135 Zero-G Environment featuring Soichi Noguchi, Mission Specialist; 6) TPS Extravehicular Activity Tool Demonstration; 7) TPS Repair Testing Vacuum Glove box; 8) TPS Repair Testing Human Thermal Vacuum Chamber; 9) TPS Reentry Testing Atmospheric Reentry Materials and Structures Evaluation Facility; 10) TPS Alternative Repair Concept; 11) Lora Bailey Lead Engineer for EVA Tools; 12) Reinforced Carbon-Carbon ATK Thiokol Plug Repair Animation; 13) 3-Percent Model Build-Up; and 14) Wind Tunnel Testing RCC Aging Research Ballistic Testing.

Source record↗

Analytical modeling and sensor monitoring for optimal processing of polymeric composite material systems

Process simulation models and cure monitoring sensors are discussed for use in optimal processing of fiber-reinforced composites. Analytical models relate the specified temperature and pressure cure cycle to the thermal, chemical, and physical processes occurring in the composite during consolidation and cure. Frequency-dependent electromagnetic sensing (FDEMS) is described as an in situ sensor for monitoring the composite curing process and for verification of process simulation models. A model for resin transfer molding of textile composites is used to illustrate the predictive capabilities of a process simulation model. The model is used to calculate the resin infiltration time, fiber volume fraction, resin viscosity, and resin degree of cure. Results of the model are compared with in situ FDEMS measurements.

Loos, Alfred C.↗

Evolution of miniature detectors and focal plane arrays for infrared sensors

Sensors that are sensitive in the infrared spectral region have been under continuous development since the WW2 era. A quest for the military advantage of 'seeing in the dark' has pushed thermal imaging technology toward high spatial and temporal resolution for night vision equipment, fire control, search track, and seeker 'homing' guidance sensing devices. Similarly, scientific applications have pushed spectral resolution for chemical analysis, remote sensing of earth resources, and astronomical exploration applications. As a result of these developments, focal plane arrays (FPA) are now available with sufficient sensitivity for both high spatial and narrow bandwidth spectral resolution imaging over large fields of view. Such devices combined with emerging opto-electronic developments in integrated FPA data processing techniques can yield miniature sensors capable of imaging reflected sunlight in the near IR and emitted thermal energy in the Mid-wave (MWIR) and longwave (LWIR) IR spectral regions. Robotic space sensors equipped with advanced versions of these FPA's will provide high resolution 'pictures' of their surroundings, perform remote analysis of solid, liquid, and gas matter, or selectively look for 'signatures' of specific objects. Evolutionary trends and projections of future low power micro detector FPA developments for day/night operation or use in adverse viewing conditions are presented in the following test.

Watts, Louis A.↗

Exploration Extravehicular Mobility Unit (xEMU) Helmet and Extravehicular Visor Assembly (EVVA) Chamber B Thermal Vacuum Testing Results

NASA’s Exploration Extravehicular Mobility Unit (xEMU) is the government reference next-generation spacesuit design and is engineered to protect astronauts from extreme lunar environmental temperatures. To evaluate the xEMU hardware thermal requirements, the xEMU Testing Team invented, designed, and executed a dual-suit, uncrewed thermal vacuum (TVAC) test at Johnson Space Center’s (JSC) Chamber B. This paper details the test methodology, hardware setup, and results from the xEMU helmet and extravehicular visor assembly (EVVA). Two helmets/EVVAs were tested simultaneously in Chamber B, with different thermal environments and EVVA configurations. For the helmet/EVVA on the Short xEMU (SxEMU) test article, five thermal profiles were tested during five simulated EVAs, with four different visor and shade configurations. For the helmet/EVVA on the second xEMU, eleven unique thermal profiles were tested including both cold and hot environmental cases over the course of five continuous days of testing, with a single visor and shade configuration. The radiative thermal environment was controlled through exposure to liquid-nitrogen shrouds on the chamber walls and through two separate heater cages surrounding each respective test article. The thermal effects of the Exploration Informatics (xINFO) lights and camera on the helmet/EVVA was also tested. Twenty-two temperature sensors were used to collect data in critical locations in the xEMU helmet/EVVA assembly. This paper will document the testing results and compare the test data against the xEMU helmet/EVVA and system-level thermal models for model validation.

xEMU↗

Terrestrial density of strongly-coupled relics

The simplest cosmologies motivate the consideration of dark matter subcomponents that interact significantly with normal matter. Moreover, such strongly coupled relics may have evaded detection to date if upon encountering the Earth they rapidly thermalize down to terrestrial temperatures, T ⊕ ∼ 300 K ∼ 25 meV , well below the thresholds of most existing dark matter detectors. This shedding of kinetic energy implies a drastic enhancement to the local density, motivating the consideration of alternative detection techniques sensitive to a large density of slowly moving dark matter particles. In this work, we provide a rigorous semianalytic derivation of the terrestrial overdensities of strongly coupled relics, with a particular focus on millicharged particles (MCPs). We go beyond previous studies by incorporating improved estimates of the MCP-atomic scattering cross section, new contributions to the terrestrial density of sub-GeV relics that are independent of the Earth’s gravitational field, and local modifications that can arise due to the cryogenic environments of precision sensors. We also generalize our analysis in order to estimate the terrestrial density of thermalized MCPs that are produced from the collisions of high-energy cosmic rays and become bound by the Earth’s electric field. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of Thermally Stable and Highly Fluorescent IR Dyes

Fluorophores are the core component in various optical applications such as sensors and probes. Fluorphores with low-energy or long wavelength emission, in particular, in NIR region, possess advantages of low interference and high sensitivity. In this study, we has explored several classes of imidazole-based compounds for NIR fluorescent properties and concluded: (1) thiazole-based imidazole compounds are fluorescent; (2) emission energy is tunable by additional donor groups; (3) they also possess impressive two- photon absorption properties; and (4) fluorescence emission can be induced by two- photon input. This report summarizes (1) synthesis of new series of fluorophore; (2) impact of electron-withdrawing groups on fluorescent property; (3) unique property of two-photon absorption; and (4) on-going development.

Bu, Xiu R.↗

Robust Platinum Resistor Thermometer (PRT) Sensors and Reliable Bonding for Space Missions

Platinum resistance thermometers (PRTs) provide accurate temperature measurements over a wide temperature range and are used extensively on space missions due to their simplicity and linearity. A standard on spacecraft, PRTs are used to provide precision temperature control and vehicle health assessment. This paper reviews the extensive reliability testing of platinum resistor thermometer sensors (PRTs) and bonding methods used on the Mars Science Laboratory (MSL) mission and for the upcoming Soil Moisture Active Passive (SMAP) mission. During the Mars Exploration Rover (MER) mission, several key, JPL-packaged PRTs failed on those rovers prior to and within 1-Sol of landing due to thermally induced stresses. Similar failures can be traced back to other JPL missions dating back thirty years. As a result, MSL sought out a PRT more forgiving to the packaging configurations used at JPL, and extensively tested the Honeywell HRTS-5760-B-U-0-12 sensor to successfully demonstrate suitable robustness to thermal cycling. Specifically, this PRT was cycled 2,000 times, simulating three Martian winters and summers. The PRTs were bonded to six substrate materials (Aluminum 7050, treated Magnesium AZ231-B, Stainless Steel 304, Albemet, Titanium 6AL4V, and G-10), using four different aerospace adhesives--two epoxies and two silicones--that conformed to MSL's low out-gassing requirements. An additional epoxy was tested in a shorter environmental cycling test, when the need for a different temperature range adhesive was necessary for mobility and actuator hardware late in the fabrication process. All of this testing, along with electrostatic discharge (ESD) and destructive part analyses, demonstrate that this PRT is highly robust, and not subject to the failure of PRTs on previous missions. While there were two PRTs that failed during fabrication, to date there have been no in-flight PRT failures on MSL, including those on the Curiosity rover. Since MSL, the sensor has gone through a change in construction such that the manufacturer significantly restricts the minimum temperature. However, significant subsequent testing was performed with this new version of the part to show that it indeed is still robust to at least Mars minimum temperatures of -135(sup o)C. The additional completed testing will be described. This work has resulted in a successful sensor package qualification and a reliable bonding method suitable for use over large temperature extremes.

dectector↗

Robust Platinum Resistor Thermometer (PRT) Sensors and Reliable Bonding for Space Missions

Platinum resistance thermometers (PRTs) provide accurate temperature measurements over a wide temperature range and are used extensively on space missions due to their simplicity and linearity. A standard on spacecraft, PRTs are used to provide precision temperature control and vehicle health assessment. This paper reviews the extensive reliability testing of platinum resistor thermometer sensors (PRTs) and bonding methods used on the Mars Science Laboratory (MSL) mission and for the upcoming Soil Moisture Active Passive (SMAP) mission. During the Mars Exploration Rover (MER) mission, several key, JPL-packaged PRTs failed on those rovers prior to and within 1-Sol of landing due to thermally induced stresses. Similar failures can be traced back to other JPL missions dating back thirty years. As a result, MSL sought out a PRT more forgiving to the packaging configurations used at JPL, and extensively tested the Honeywell HRTS-5760-B-U-0-12 sensor to successfully demonstrate suitable robustness to thermal cycling. Specifically, this PRT was cycled 2,000 times, simulating three Martian winters and summers. The PRTs were bonded to six substrate materials (Aluminum 7050, treated Magnesium AZ231-B, Stainless Steel 304, Albemet, Titanium 6AL4V, and G-10), using four different aerospace adhesives--two epoxies and two silicones--that conformed to MSL's low out-gassing requirements. An additional epoxy was tested in a shorter environmental cycling test, when the need for a different temperature range adhesive was necessary for mobility and actuator hardware late in the fabrication process. All of this testing, along with electrostatic discharge (ESD) and destructive part analyses, demonstrate that this PRT is highly robust, and not subject to the failure of PRTs on previous missions. While there were two PRTs that failed during fabrication, to date there have been no in-flight PRT failures on MSL, including those on the Curiosity rover. Since MSL, the sensor has gone through a change in construction such that the manufacturer significantly restricts the minimum temperature. However, significant subsequent testing was performed with this new version of the part to show that it indeed is still robust to at least Mars minimum temperatures of -135 degrees Centigrade. The additional completed testing will be described. This work has resulted in a successful sensor package qualification and a reliable bonding method suitable for use over large temperature extremes

Platinum Resistor Thermometer (PRT)↗

Calibration of VIIRS F1 Sensor Fire Detection Band Using lunar Observations

Visible Infrared Imager Radiometer Suite (VIIRS) Fight 1 (Fl) sensor includes a fire detection band at roughly 4 microns. This spectral band has two gain states; fire detection occurs in the low gain state above approximately 345 K. The thermal bands normally utilize an on-board blackbody to provide on-orbit calibration. However, as the maximum temperature of this blackbody is 315 K, the low gain state of the 4 micron band cannot be calibrated in the same manner as the rest of the thermal bands. Regular observations of the moon provide an alternative calibration source. The lunar surface temperature has been recently mapped by the DIVINER sensor on the LRO platform. The periodic on-board high gain calibration along with the DIVINER surface temperatures was used to determine the emissivity and solar reflectance of the lunar surface at 4 microns; these factors and the lunar data are then used to fit the low gain calibration coefficients of the 4 micron band. Furthermore, the emissivity of the lunar surface is well known near 8.5 microns due to the Christiansen feature (an emissivity maximum associated with Si-O stretching vibrations) and the solar reflectance is negligible. Thus, the 8.5 micron band is used for relative calibration with the 4 micron band to de-trend any temporal variations. In addition, the remaining thermal bands are analyzed in a similar fashion, with both calculated emissivities and solar reflectances produced.

McIntire, Jeff↗