Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME SIGNAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Broadband surface-enhanced coherent anti-Stokes Raman spectroscopy with high spectral resolution

Both the surface-enhanced Raman spectroscopy (SERS) and coherent anti-Stokes Raman spectroscopy (CARS) are widely used methods in the bio-sensing field for improving the intensity of Raman scattering process. By combining the mechanisms of CARS (coherence and nonlinear process) and SERS (plasmon resonance), a multiplicative enhancement can be achieved through surface-enhanced CARS (SECARS). Besides sensitivity, high specificity with wide spectral bandwidth is also preferred for bio-sensing techniques but not well developed in SECARS setups reported in the literature. A broadband SECARS setup with high sensitivity and high spectral resolution is presented. Rhodamine 6G dye molecules and several biomolecules are used as the model system to benchmark the functionality of the SECARS system in terms of its sensitivity, the lowest detectable concentration, and the spectral resolution. Our setup rendered single-molecule sensitivity with spectral resolution of <35 cm -1 . More than 10 2 times stronger signal-to-noise ratio compared with that of SERS is observed with the detection limit being 10 -9 m. Different from the SECARS systems in the literature, our setup employs a unique graphene-Au pyramids hybrid platform. The graphene in this structure provides additional SERS enhancement and a bio-compatible surface. Finally, this powerful technique could be instrumental in furthering the understanding of various chemical and biological processes.

42 ENGINEERING↗

Measurement of Higgs boson production and properties in the WW decay channel with leptonic final states

A search for the standard model Higgs boson decaying to a W-boson pair at the LHC is reported. The event sample corresponds to an integrated luminosity of 4.9 and 19.4 inverse femtobarns collected with the CMS detector in pp collisions at √s = 7 and 8 TeV, respectively. The Higgs boson candidates are selected in events with two or three charged leptons. An excess of events above background is observed, consistent with the expectation from the standard model Higgs boson with a mass of around 125 GeV. The probability to observe an excess equal or larger than the one seen, under the background-only hypothesis, corresponds to a significance of 4.3 standard deviations for m H = 125.6 GeV. The observed signal cross section times the branching fraction to WW for m H = 125.6 GeV is 0.72+0.20-0.18 times the standard model expectation. The spin-parity J P =0 + hypothesis is favored against a narrow resonance with J P =2 + or J P =0 – that decays to a W-boson pair. Lastly, this result provides strong evidence for a Higgs-like boson decaying to a W-boson pair.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Non-resonant anomaly detection with background extrapolation

Complete anomaly detection strategies that are both signal sensitive and compatible with background estimation have largely focused on resonant signals. Non-resonant new physics scenarios are relatively under-explored and may arise from off-shell effects or final states with significant missing energy. In this paper, we extend a class of weakly supervised anomaly detection strategies developed for resonant physics to the non-resonant case. Machine learning models are trained to reweight, generate, or morph the background, extrapolated from a control region. A classifier is then trained in a signal region to distinguish the estimated background from the data. The new methods are demonstrated using a semi-visible jet signature as a benchmark signal model, and are shown to automatically identify the anomalous events without specifying the signal ahead of time.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Seeing behind black hole horizons in SYK

We present an explicit reconstruction of the interior of an AdS2 black hole in Jackiw-Teitelboim gravity, that is entirely formulated in the dual SYK model and makes no direct reference to the gravitational bulk. We do this by introducing a probe “observer” in the right wormhole exterior and using the prescription of [arXiv:2009.04476] to transport SYK operators along the probe’s infalling worldline and into the black hole interior, using an appropriate SYK modular Hamiltonian. Our SYK computation recovers the precise proper time at which signals sent from the left boundary are registered by our observer’s apparatus inside the wormhole. The success of the computation relies on the universal properties of SYK and we outline a promising avenue for extending it to higher dimensions and applying it to the computation of scattering amplitudes behind the horizon.

2D Gravity↗

Can MR elastography be used to measure liver stiffness in patients with iron overload?

Untreated hepatic iron overload causes hepatic fibrosis and cirrhosis and can predispose to hepatocellular carcinoma. MR elastography (MRE) provides a non-invasive means to measure liver stiffness, which correlates with liver fibrosis but standard gradient recalled echo (GRE)-based MRE techniques fail in patients with high iron due to very low hepatic signal. Short echo time (TE) 2D spin echo echoplanar imaging (SE-EPI)-based MRE may allow measurement of stiffness in the iron loaded liver. The purpose of this study was to describe the use of such an MRE sequence in patients undergoing liver iron quantification by MRI. In our preliminary study of 43 patients with mean LIC of 9.3 mg/g (range 1.8–21.5 mg/g), liver stiffness measurements could be made in 77% (33/43) of patients with a short TE, SE-EPI based MRE sequence. On average, mean LIC in patients with failed MRE was higher than in those with successful MRE (15.9 mg/g dry weight vs. 7.3 mg/g), but a cut-off value for successful MRE could not be established. Seven patients (21% of those with successful MRE) had liver stiffness values suggestive of the presence of significant fibrosis (> 2.49 kPa). A short TE, SE-EPI based MR elastography sequence allows successful measurement of liver stiffness in a majority of patients with liver iron loading, potentially allowing non-invasive screening for fibrosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fluorescence-based optimization of human bitter taste receptor expression in Saccharomyces cerevisiae

Human TAS2 receptors (hTAS2Rs) perceive bitter tastants, but few studies have explored the structure-function relationships of these receptors. In this paper, we report our trials on the large-scale preparations of hTAS2Rs for structural analysis. Twenty-five hTAS2Rs were expressed using a GFP-fusion yeast system in which the constructs and the culture conditions (e.g., the signal sequence, incubation time and temperature after induction) were optimized by measuring GFP fluorescence. After optimization, five hTAS2Rs (hTAS2R7, hTAS2R8, hTAS2R16, hTAS2R41, and hTAS2R48) were expressed at levels greater than 1 mg protein/L of culture, which is a preferable level for purification and crystallization. Among these five bitter taste receptors, hTAS2R41 exhibited the highest detergent solubilization efficiency of 87.1% in n-dodecyl-{beta}-D-maltopyranoside (DDM)/cholesteryl hemisuccinate (CHS). Fluorescence size-exclusion chromatography showed that hTAS2R41 exhibited monodispersity in DDM/CHS without aggregates, suggesting that hTAS2R41 is a good target for future crystallization trials.

60 APPLIED LIFE SCIENCES↗

Micro/nanofabricated environments for synthetic biology

A better understanding of how confinement, crowding and reduced dimensionality modulate reactivity and reaction dynamics will aid in the rational and systematic discovery of functionality in complex biological systems. Artificial micro- and nanofabricated structures have helped elucidate the effects of nanoscale spatial confinement and segregation on biological behavior, particularly when integrated with microfluidics, through precise control in both space and time of diffusible signals and binding interactions. Examples of nanostructured interfaces for synthetic biology include the development of cell-like compartments for encapsulating biochemical reactions, nanostructured environments for fundamental studies of diffusion, molecular transport and biochemical reaction kinetics, and regulation of biomolecular interactions as functions of micro- and nanofabricated topological constraints.

Collier, Pat↗

Sodium diffusion in heterogeneous porous media: Connecting laboratory experiments and simulations

Sodium has been suggested as a tracer for brine in reservoir formations where a significant amount of sodium ion is found mainly in the aqueous phase. Fortunately, the most abundant sodium isotope, 23 Na, is Nuclear Magnetic Resonance (NMR) active, making it possible to study the structure and dynamical properties of both bulk and pore confined fluid systems. We investigated the diffusion of key dissolved sodium species in bulk solution and porous media as a function of composition, ionic strength, and permeability of the carbonate samples using NMR relaxometry and pulsed-field gradient (PFG) NMR techniques. We use Indiana limestone as an example of natural porous media and water as a freely diffusible tracer and carrier. We demonstrate apparent diffusion measurement of sodium based on changes in spin–spin relaxation time (T 2 ) signal in pore confinement. The diffusion rate of sodium decreases with increasing counter-ion size. This effect is greater at higher ionic strengths and lower chemical potentials in porous media. The reactive transport code, CrunchFlow, was used to complement the NMR experiments to simulate diffusion behavior in porous media. Combining these two methods provides a powerful approach to estimating effective diffusion coefficients in heterogeneous matrices. The modeling considers the influence of physical properties (porosity and tortuosity) and chemical properties (geochemical composition and chemical gradients). The results presented in this work highlight the advantage of measuring apparent diffusivity using NMR T 2 relaxometry in conjunction with numerical simulation to derive effective diffusivity and the corresponding matrix properties (i.e., tortuosity) of the system.

58 GEOSCIENCES↗

A wearable sensor based on CLYC scintillators

We developed a wearable radiation sensor using Cs 2 LiYCl 6 :Ce (CLYC) for simultaneous gamma-ray and neutron detection. The system includes two ø2.5×2.5 cm 3 crystals coupled to small, metal-body photomultiplier tubes. A custom, low-power electronics base digitizes the output signal at three time points and enables both pulse height and pulse shape discrimination of neutrons and gamma-rays. Data, including spectra, can be transferred via a wired or wireless connection. The total gamma-ray and neutron counts, anomaly detection metrics, and identified isotopes are displayed on a small screen on the device. Users may leave the system in unattended mode to collect long-dwell energy spectra. The prototype system has overall dimensions of 13×7.5×18 cm 3 and weight of 1.3 kg, not including the protective pouch, and runs on six AA alkaline batteries for 29 hours with a 1% wireless transmission duty cycle and 41 hours with the wireless turned off . In this paper, we summarize the system design and present characterization results from the detector modules. The energy resolution is about 6.5% full width at half maximum at 662 keV due to the small photomultiplier tube selected, and the linearity and pulse shape discrimination performance are very good.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The NOvA power distribution system

We describe the power distribution systems and grounding schemes built for the near and far detectors of the NOvA long-baseline neutrino experiment. They are used to power the avalanche photodiodes and their thermoelectric coolers, the front-end boards that read out, digitize and time stamp the signals from the avalanche photodiodes, and the data concentrator modules used to receive and format the data from the front-end boards before sending them to a farm of computers used to build the events. Furthermore, the system powers 344,064 readout channels in the far detector and 20,192 channels in the near detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The impact of detection rate changes and correlations on random-coincidence background measurements

Coincidence detection of multiple particles emitted during an experiment can yield a new depth of understanding of the underlying process under study. However, the probability of detecting particles that are generated from the same physical event within a given coincidence time window is generally much lower than that of detecting particles that appear in the same coincidence time window, but were not created from the same physical event, and are therefore detected randomly in coincidence with each other. Thus, accurate and precise methods of measuring this random-coincidence background are essential for a wide variety of fields of science. A method to determine this background directly using the data themselves without any additional experimental run time or fake signals introduced in the data was recently established (O’Donnell, 2016). This method yields a statistical uncertainty on the random-coincidence background that is orders of magnitude smaller than that of the true coincidence data, though the potential for systematic errors of backgrounds from this method was never explored. In this work, we discuss common varieties of correlated and uncorrelated changes in the detection rates of each particle detected in an experiment. Here we demonstrate here that a correlation between particle detection rates from, for example, an incident particle beam that initiates a physical process of interest, creates systematic errors in the random-coincidence background measurement. We also discuss the impact of a variety of other realistic scenarios for rate changes in experiments. Lastly, a method is introduced to correct for errors in the random-coincidence background from any source, yielding an optimization between statistical precision and eliminating potential lingering systematic errors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Υ production and nuclear modification at forward rapidity in Pb–Pb collisions at $\sqrt{S_{NN}}$ = 5.02 TeV

The production of Υ mesons in Pb–Pb collisions at a centre-of-mass energy per nucleon pair $\sqrt{S_{NN}}$ = 5.02 TeV is measured with the muon spectrometer of the ALICE detector at the LHC. The yields as well as the nuclear modification factors are determined in the forward rapidity region 2.5 < y < 4.0, as a function of rapidity, transverse momentum and collision centrality. The results show that the production of the Υ(1S) meson is suppressed by a factor of about three with respect to the production in proton– proton collisions. For the first time, a significant signal for the Υ(2S) meson is observed at forward rapidity, indicating a suppression stronger by about a factor 2–3 with respect to the ground state. The measurements are compared with transport, hydrodynamic, comover and statistical hadronisation model calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Internal mixing dynamics of Cu/Sn-Pb plasmas produced by femtosecond laser ablation

Chemical imaging applications using Laser Induced Breakdown Spectroscopy (LIBS) involve laser ablation sampling at interfaces or boundaries between materials with different thermophysical and optical properties, leading to the formation of two initially isolated plasmas. The mechanisms of mixing in these plasmas and their direct implications on spectral emission and chemical imaging remain largely unknown. We investigate the mixing dynamics of isolated plasmas produced using femtosecond (fs) laser pulses at the interface between two different model Cu and Sn–Pb samples. Specifically, we study the spatial and temporal mixing dynamics and outer plasma expansion dynamics of the fs plasma components. The time-resolved degree of component mixing, horizontal and vertical expansion, mixing speed, and temperature and electron density of the heterogeneous plasma are characterized. Mixing processes are initiated early on, <100 ns after the laser pulse, and continue taking place until the end of plasma emission persistence at a constant velocity of 10 4 cm/s. In conclusion, these findings demonstrate that proper selection of detection timing parameters and signal collection position are critically important in precise LIBS measurements to ensure that full plasma mixing has taken place and that homogeneous spectral emission is properly detected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An oscillatory network controlling self-renewal of skeletal muscle stem cells

The balance between proliferation and differentiation of muscle stem cells is tightly controlled, ensuring the maintenance of a cellular pool needed for muscle growth and repair. Muscle stem cells can proliferate, they can generate differentiating cells, or they self-renew to produce new stem cells. Notch signaling plays a crucial role in this process. Recent studies revealed that expression of the Notch effector HES1 oscillates in activated muscle stem cells. The oscillatory expression of HES1 periodically represses transcription from the genes encoding the myogenic transcription factor MYOD and the Notch ligand DLL1, thereby driving MYOD and DLL1 oscillations. This oscillatory network allows muscle progenitor cells and activated muscle stem cells to remain in a proliferative and ‘undecided’ state, in which they can either differentiate or self-renew. When HES1 is downregulated, MYOD oscillations become unstable and are replaced by sustained expression, which drives the cells into terminal differentiation. During development and regeneration, proliferating stem cells contact each other and the stability of the oscillatory expression depends on regular DLL1 inputs provided by neighboring cells. In such communities of cells that receive and provide Notch signals, the appropriate timing of DLL1 inputs is important, as sustained DLL1 cannot replace oscillatory DLL1. Thus, in cell communities, DLL1 oscillations ensure the appropriate balance between self-renewal and differentiation. In summary, oscillations in myogenic cells are an important example of dynamic gene expression determining cell fate.

60 APPLIED LIFE SCIENCES↗

Ambient-Pressure X-ray Photoelectron Spectroscopy Characterization of Radiation-Induced Chemistries of Organotin Clusters

Advances in extreme ultraviolet (EUV) photolithography require the development of next-generation resists that allow high-volume nanomanufacturing with a single nanometer patterning resolution. Organotin-based photoresists have demonstrated nanopatterning with high resolution, high sensitivity, and low-line edge roughness. However, very little is known regarding the detailed reaction mechanisms that lead to radiation-induced solubility transitions. In this study, we investigate the interaction of soft X-ray radiation with organotin clusters to better understand radiation-induced chemistries associated with EUV lithography. Butyltin Keggin clusters (β-NaSn13) were used as a model organotin photoresist, and characterization was performed using ambient-pressure X-ray photoelectron spectroscopy. The changes in relative atomic concentrations and associated chemical states in β-NaSn 13 resists were evaluated after exposure to radiation for a range of ambient conditions and photon energies. A significant reduction in the C 1s signal versus exposure time was observed, which corresponds to the radiation-induced homolytic cleavage of the butyltin bond in the β-NaSn 13 clusters. To improve the resist sensitivity, we evaluated the effect of oxygen partial pressure during radiation exposures. Here, we found that both photon energy and oxygen partial pressure had a strong influence on the butyl group desorption rate. These studies advance the understanding of radiation-induced processes in β-NaSn 13 photoresists and provide mechanistic insights for EUV photolithography.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

13 C Radiofrequency Amplification by Stimulated Emission of Radiation Threshold Sensing of Chemical Reactions

Conventional nuclear magnetic resonance (NMR) enables detection of chemicals and their transformations by exciting nuclear spin ensembles with a radio-frequency pulse followed by detection of the precessing spins at their characteristic frequencies. The detected frequencies report on chemical reactions in real time and the signal amplitudes scale with concentrations of products and reactants. Here, we employ Radiofrequency Amplification by Stimulated Emission of Radiation (RASER), a quantum phenomenon producing coherent emission of 13 C signals, to detect chemical transformations. The 13 C signals are emitted by the negatively hyperpolarized biomolecules without external radio frequency pulses and without any background signal from other, nonhyperpolarized spins in the ensemble. Here, we studied the hydrolysis of hyperpolarized ethyl-[1- 13 C]acetate to hyperpolarized [1- 13 C]acetate, which was analyzed as a model system by conventional NMR and 13 C RASER. The chemical transformation of 13 C RASER-active species leads to complete and abrupt disappearance of reactant signals and delayed, abrupt reappearance of a frequency-shifted RASER signal without destroying 13 C polarization. Further, the experimentally observed “quantum” RASER threshold is supported by simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Supercontinuum Stimulated Emission Depletion Fluorescence Lifetime Imaging

Supercontinuum (SC) stimulated emission depletion (STED) fluorescence lifetime imaging is demonstrated by using time-correlated single-photon counting (TCSPC) detection. The spatial resolution of the developed STED instrument was measured by imaging monodispersed 40-nm fluorescent beads and then determining their fwhm, and was 36 ± 9 and 40 ± 10 nm in the X and Y coordinates, respectively. The same beads measured by confocal microscopy were 450 ± 50 and 430 ± 30 nm, which is larger than the diffraction limit of light due to underfilling the microscope objective. Underfilling the objective and time gating the signal were necessary to achieve the stated STED spatial resolution. The same fluorescence lifetime (2.0 ± 0.1 ns) was measured for the fluorescent beads by using confocal or STED lifetime imaging. The instrument has been applied to study Alexa Fluor 594-phalloidin labeled F-actin-rich projections with dimensions smaller than the diffraction limit of light in cultured cells. Fluorescence lifetimes of the actin-rich projections range from 2.2 to 2.9 ns as measured by STED lifetime imaging.

36 MATERIALS SCIENCE↗

VUV Photoionization Cross Sections of HO 2 , H 2 O 2 , and H 2 CO

The absolute vacuum ultraviolet (VUV) photoionization spectra of the hydroperoxyl radical (HO2), hydrogen peroxide (H 2 O 2 ), and formaldehyde (H2CO) have been measured from their first ionization thresholds to 12.008 eV. HO 2 , H 2 O 2 , and H 2 CO were generated from the oxidation of methanol initiated by pulsed-laser-photolysis of Cl 2 in a low-pressure slow flow reactor. Reactants, intermediates, and products were detected by time-resolved multiplexed synchrotron photoionization mass spectrometry. Absolute concentrations were obtained from the time-dependent photoion signals by modeling the kinetics of the methanol oxidation chemistry. Photoionization cross sections were determined at several photon energies relative to the cross section of methanol, which was in turn determined relative to that of propene. These measurements were used to place relative photoionization spectra of HO 2 , H 2 O 2 , and H 2 CO on an absolute scale, resulting in absolute photoionization spectra.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗