Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “System Monitoring and Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Relative Gain Monitoring of the GlueX Calorimeters

The relative gain of the photodetectors for the GlueX Barrel and Forward calorimeters will be monitored using modular LED driver systems. The BCAL system consists of a global controller that feeds power, bias voltage and trigger signals to 96 local controllers situated at the ends of the 48 BCAL modules, which drive 40 LEDs associated with the 40 light guides at the end of each module. The FCAL system consists also of a global controller, a local controller for each acrylic quadrant covering the face of the FCAL, and ten 4-LED pulser boards per local controller connected in a star configuration along the edges of the acrylic panes. The respective systems are currently being installed on the detectors and their tested performance is presented herein.

43 PARTICLE ACCELERATORS↗

Electromechanical actuation for cryogenic valve control

The design and analysis of the electromechanical actuator (EMA) being developed for the NASA/Marshall Space Flight Center as part of the National Launch System (NLS) Propellant Control Effector Advanced Development Program (ADP) are addressed. The EMA design uses several proven technologies combined into a single modular package which includes single stage high ratio gear reduction, redundant electric motors mounted on a common drive shaft, redundant drive and control electronics, and digital technology for performing the closed loop position feedback, communication, and health monitoring functions. Results of tests aimed at evaluating both component characteristics and overall system performance demonstrated that the goal of low cost, reliable control in a cryogenic environment is feasible.

Lister, M. J.↗

Computational Optimization of 133m Xe Production via Neutron Irradiation in a TRIGA Reactor

Here, the Comprehensive Nuclear-Test-Ban Treaty bans all nuclear tests worldwide. As part of treaty compliance, the concentration of radioactive nuclides in the atmosphere is monitored to detect nuclear weapons tests. Radioactive noble gas fission products, specifically radioxenon, can vent into the atmosphere after a nuclear weapons test, even if the test is well contained underground or underwater. Radioxenon thus serves as a signal for nuclear weapons tests. All atmospheric monitoring systems require samples of radioxenon isotopes for detector calibration, quality control, and certification. Here, we present a novel, improved method for creating samples of 133m Xe via neutron irradiation of 132 Xe in the Washington State University TRIGA reactor. 132 Xe neutron absorption results in either 133 Xe or 133m Xe—thermal neutron absorption results in 133m Xe 12% of the time, while fast neutron absorption (above ~1 MeV) results in 133m Xe ~50% of the time. To optimize the production of 133m Xe via neutron absorption in 132 Xe in the thermal TRIGA reactor, spectral tuning using an irradiation chamber is required to maximize the fraction of fast neutrons being absorbed and minimize the number of thermal neutrons interacting with the 132 Xe. We used MCNP to tally 132 Xe absorptions with the isotopic tally function, flux tallies and neutron attenuation to estimate the number of neutrons reaching the 132 Xe through the irradiation chamber, and the adjoint importance function to improve the source strength estimate. Additionally, we performed a heat transfer analysis for safety considerations. It was determined that the use of a 96% enriched 10 B boron carbide chamber, placed next to the fuel elements in reactor position D8, increases the 133m Xe/ 133 Xe activity ratio from a baseline value of 0.3 to 1.0, a 233% increase. Additionally, it was determined that the alpha heating produced in the boron does not become an unmanageable problem in the Washington State University reactor.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Beyond Arms-Control Monitoring

Expanded monitoring of the environment, everywhere and at all times, can advance arms control around the world, enhancing transparency among nations. In particular, improved characterization of the atmosphere now offers powerful opportunities for global monitoring, with multiple societal benefits. It may be useful to think of environmental monitoring as a long-term objective of arms-control verification.

arms-control monitoring↗

Solid state thermostat has integral probe and circuitry

Compact, reliable thermostat provides a temperature readout signal and a continuous temperature-control output for temperature monitoring by automatic checkout equipment or telemetry systems. It employs a solid state circuit in a housing rigidly attached to a thermistor probe.

Source record↗

Development of display design and command usage guidelines for Spacelab experiment computer applications

Individual Spacelab experiments are responsible for developing their CRT display formats and interactive command scenarios for payload crew monitoring and control of experiment operations via the Spacelab Data Display System (DDS). In order to enhance crew training and flight operations, it was important to establish some standardization of the crew/experiment interface among different experiments by providing standard methods and techniques for data presentation and experiment commanding via the DDS. In order to establish optimum usage guidelines for the Spacelab DDS, the capabilities and limitations of the hardware and Experiment Computer Operating System design had to be considered. Since the operating system software and hardware design had already been established, the Display and Command Usage Guidelines were constrained to the capabilities of the existing system design. Empirical evaluations were conducted on a DDS simulator to determine optimum operator/system interface utilization of the system capabilities. Display parameters such as information location, display density, data organization, status presentation and dynamic update effects were evaluated in terms of response times and error rates.

Dodson, D. W.↗

Design, development, and field demonstration of a remotely deployable water quality monitoring system

A prototype water quality monitoring system is described which offers almost continuous in situ monitoring. The two-man portable system features: (1) a microprocessor controlled central processing unit which allows preprogrammed sampling schedules and reprogramming in situ; (2) a subsurface unit for multiple depth capability and security from vandalism; (3) an acoustic data link for communications between the subsurface unit and the surface control unit; (4) eight water quality parameter sensors; (5) a nonvolatile magnetic bubble memory which prevents data loss in the event of power interruption; (6) a rechargeable power supply sufficient for 2 weeks of unattended operation; (7) a water sampler which can collect samples for laboratory analysis; (8) data output in direct engineering units on printed tape or through a computer compatible link; (9) internal electronic calibration eliminating external sensor adjustment; and (10) acoustic location and recovery systems. Data obtained in Saginaw Bay, Lake Huron are tabulated.

Wallace, J. W.↗

Operations and maintenance manual for the linear accelerator (sled)

The Linear Accelerator, a sliding chair which is pulled along a stationary platform in a horizontal axis is described. The driving force is a motor controlled by a velocity loop amplifier, and the mechanical link to the chair is a steel cable. The chair is moved in forward and reverse directions as indicated by the direction of motor rotation. The system operation is described with emphasis on the electronic control and monitoring functions. Line-by-line schematics and wire lists are included.

Source record↗

FINDS: A fault inferring nonlinear detection system. User's guide

The computer program FINDS is written in FORTRAN-77, and is intended for operation on a VAX 11-780 or 11-750 super minicomputer, using the VMS operating system. The program detects, isolates, and compensates for failures in navigation aid instruments and onboard flight control and navigation sensors of a Terminal Configured Vehicle aircraft in a Microwave Landing System environment. In addition, FINDS provides sensor fault tolerant estimates for the aircraft states which are then used by an automatic guidance and control system to land the aircraft along a prescribed path. FINDS monitors for failures by evaluating all sensor outputs simultaneously using the nonlinear analytic relationships between the various sensor outputs arising from the aircraft point mass equations of motion. Hence, FINDS is an integrated sensor failure detection and isolation system.

Lancraft, R. E.↗

Digital Autonomous Terminal Access Communication (DATAC) system

In order to accommodate the increasing number of computerized subsystems aboard today's more fuel efficient aircraft, the Boeing Co. has developed the DATAC (Digital Autonomous Terminal Access Control) bus to minimize the need for point-to-point wiring to interconnect these various systems, thereby reducing total aircraft weight and maintaining an economical flight configuration. The DATAC bus is essentially a local area network providing interconnections for any of the flight management and control systems aboard the aircraft. The task of developing a Bus Monitor Unit was broken down into four subtasks: (1) providing a hardware interface between the DATAC bus and the Z8000-based microcomputer system to be used as the bus monitor; (2) establishing a communication link between the Z8000 system and a CP/M-based computer system; (3) generation of data reduction and display software to output data to the console device; and (4) development of a DATAC Terminal Simulator to facilitate testing of the hardware and software which transfer data between the DATAC's bus and the operator's console in a near real time environment. These tasks are briefly discussed.

Novacki, Stanley M., III↗

Operational efficiency

Space transportation avionics technology operational efficiency issues are presented in viewgraph form. Information is given on ascent flight design, autonomous spacecraft control, operations management systems, advanced mission control, telerobotics/telepresence, advanced software integration, advanced test/checkout systems, advanced training systems, and systems monitoring.

Bland, Dan↗

Computer-Based Laboratory For Engine-System Monitors

Laboratory evaluates artificially intelligent engine-system monitors without potentially hazardous measurements on actual engines. Monitor enhances engine controller by detecting undesirable trends and counteracting them. Once proved in laboratory, monitor will then be tried on real engine.

Aguilar, Robert B.↗

Evaluating model accuracy for model-based reasoning

Described here is an approach to automatically assessing the accuracy of various components of a model. In this approach, actual data from the operation of a target system is used to drive statistical measures to evaluate the prediction accuracy of various portions of the model. We describe how these statistical measures of model accuracy can be used in model-based reasoning for monitoring and design. We then describe the application of these techniques to the monitoring and design of the water recovery system of the Environmental Control and Life Support System (ECLSS) of Space Station Freedom.

Chien, Steve↗

Knowledge engineering for temporal dependency networks as operations procedures

This paper presents a case study of the knowledge engineering process employed to support the Link Monitor and Control Operator Assistant (LMCOA). The LMCOA is a prototype system which automates the configuration, calibration, test, and operation (referred to as precalibration) of the communications, data processing, metric data, antenna, and other equipment used to support space-ground communications with deep space spacecraft in NASA's Deep Space Network (DSN). The primary knowledge base in the LMCOA is the Temporal Dependency Network (TDN), a directed graph which provides a procedural representation of the precalibration operation. The TDN incorporates precedence, temporal, and state constraints and uses several supporting knowledge bases and data bases. The paper provides a brief background on the DSN, and describes the evolution of the TDN and supporting knowledge bases, the process used for knowledge engineering, and an analysis of the successes and problems of the knowledge engineering effort.

Fayyad, Kristina E.↗

NASA Goddard Space Flight Center

The NASA SLR Operational Center is responsible for: 1) NASA SLR network control, sustaining engineering, and logistics; 2) ILRS mission operations; and 3) ILRS and NASA SLR data operations. NASA SLR network control and sustaining engineering tasks include technical support, daily system performance monitoring, system scheduling, operator training, station status reporting, system relocation, logistics and support of the ILRS Networks and Engineering Working Group. These activities ensure the NASA SLR systems are meeting ILRS and NASA mission support requirements. ILRS mission operations tasks include mission planning, mission analysis, mission coordination, development of mission support plans, and support of the ILRS Missions Working Group. These activities ensure than new mission and campaign requirements are coordinated with the ILRS. Global Normal Points (NP) data, NASA SLR FullRate (FR) data, and satellite predictions are managed as part of data operations. Part of this operation includes supporting the ILRS Data Formats and Procedures Working Group. Global NP data operations consist of receipt, format and data integrity verification, archiving and merging. This activity culminates in the daily electronic transmission of NP files to the CDDIS. Currently of all these functions are automated. However, to ensure the timely and accurate flow of data, regular monitoring and maintenance of the operational software systems, computer systems and computer networking are performed. Tracking statistics between the stations and the data centers are compared periodically to eliminate lost data. Future activities in this area include sub-daily (i.e., hourly) NP data management, more stringent data integrity tests, and automatic station notification of format and data integrity issues.

Carter, David↗

Community Coordinated Modeling Center Support of Operations: Real-Time Simulations and V & V.

In support of Operations Community Coordinated Modeling Center (CCMC) performing validation and verification of space weather models. To identify suitable metrics the CCMC focus on parameters most useful to operations that CCMC resident models can provide. The real time simulations carried out at CCMC are an essential tool to test model performance and stability by using input conditions that may occur in nature at any time. Since 2001, the magnetospheric MHD model BATSRUS has been run in real time using ACE real time data. CCMC staff developed an experimental real-time system that controls uploading of the real-time ACE data, monitors continuous model execution, initiates automatic recovery procedure in case of data gaps or hardware failures, synchronizes BATSRUS and FRC runs, and periodically runs IDL based visualization software.

Kuznetsova, M.↗

Continuous replenishment of molten semiconductor in a Czochralski-process, single-crystal-growing furnace

A replenishment crucible is mounted adjacent the usual drawing crucible, from which a monocrystalline boule is drawn according to the Czochralski method. A siphon tube for molten semiconductor transfer extends from the replenishment crucible to the drawing crucible. Each crucible is enclosed within its own hermetic shell and is provided with its own heater. The siphon tube is initially filled with molten semiconductor by raising the inert atmospheric pressure in the shell surrounding the replenishment crucible above that surrounding the drawing crucible. Thereafter, adjustment of the level of molten semiconductor in the drawing crucible may be achieved by adjusting the level in either crucible, since the siphon tube will establish the same level in both crucibles. For continuous processing, solid semiconductor may be added to and melted in the replenishment crucible during the process of drawing crystals from the drawing crucible. A constant liquid level of melted semiconductor is maintained in the system by an optical monitoring device and any of several electromechanical controls of the rate of replenishment or crucible height.

Fiegl, George↗

Accuracy of an infrared marker-based patient positioning system (ExacTrac®) for stereotactic body radiotherapy in localizing the planned isocenter using fiducial markers

Stereotactic Body Radiation Therapy (SBRT) requires a controlled immobilization and position monitoring of patient and target. The purpose of this work is to analyze the performance of the imaging system ExacTrac® (ETX) using infrared and fiducial markers. Materials and methods: In order to assure the accuracy of isocenter localization, a Quality Assurance procedure was applied using an infrared marker-based positioning system. Scans were acquired of an inhouse-agar gel and solid water phantom with infrared spheres. In the inner part of the phantom, three reference markers were delineated as reference and one pellet was place internally; which was assigned as the isocenter. The iPlan® RT Dose treatment planning system. Images were exported to the ETX console. Images were acquired with the ETX to check the correctness of the isocenter placement. Adjustments were made in 6D the reference markers were used to fuse the images. Couch shifts were registered. The procedure was repeated for verification purposes. Results: The data recorded of the verifications in translational and rotational movements showed averaged 3D spatial uncertainties of 0.31 ± 0.42 mm respectively 0.82° ± 0.46° in the phantom and the first correction of these uncertainties were of 1.51 ± 1.14 mm respectively and 1.37° ± 0.61°. Conclusions: This study shows a high accuracy and repeatability in positioning the selected isocenter. The ETX-system for verifying the treatment isocenter position has the ability to monitor the tracing position of interest, making it possible to be used for SBRT positioning within uncertainty ≤1mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗