Response relationship between loading condition and corrosion fatigue behavior of nickel-aluminum bronze alloy and its crack tip damage mechanism

Highlights: • The differences of corrosion fatigue behavior of NAB alloy in air and in 3.5% NaCl solution are carefully compared. • The corrosion environment significantly accelerates the crack growth of NAB alloy and decreases the fatigue threshold. • The corrosion fatigue crack growth rate increases with the decrease of loading frequency. • The acidification and the dealumination occur in process of corrosion fatigue, resulting in the deterioration of crack tip. - Abstract: Corrosion fatigue is one of the major forms for nickel‑aluminum bronze alloy used in marine propeller. It is greatly important to understand the corrosion fatigue behavior of nickel‑aluminum bronze alloy in seawater for the purpose of improving the service life of marine equipment. In this study, corrosion fatigue crack growth rate of nickel‑aluminum bronze alloy in 3.5% NaCl solution was tested under various stress intensity factors, stress ratios and loading frequencies to reveal its corrosion fatigue mechanism. The results show that corrosion environment significantly accelerates the crack growth and decreases the corrosion fatigue threshold, which is attributed to the corrosion reactions between the metals of crack tip and corrosive medium. Among the various factors, loading frequency has more predominant influence on the corrosion fatigue crack growth rate of nickel‑aluminum bronze alloy, which can be rationally explained by the hydrogen embrittlement mechanism. Additionally, in the process of corrosion fatigue crack growth, the acidification and the dealumination would occur at the crack tip, resulting in the corrosion dissolution of κ phases and the deterioration in mechanical properties of crack tip.

36 MATERIALS SCIENCE↗

Shear deformation of pure-Cu and Cu/Nb nano-laminates using micromechanical testing

Solid phase processing by introducing shear deformation into materials can result in unique microstructure evolution and enhanced mechanical properties, especially for immiscible systems such as Cu/Nb. To better understand the correlation between microstructure and deformation behavior during shear, a dedicated testing design of stress localization at predicted sites is necessary. In this study, a specialized S-shaped specimen geometry is implemented to apply localized simple-shear loading in pure-Cu and Cu/Nb accumulative roll-bonded nanolaminates. The nanoscale microstructure and proximity of interfaces in Cu/Nb offer a ~2.8-fold increase in shear stresses than pure-Cu. In pure-Cu, the plastic instability causes shear banding and an in-plane lattice rotation. In Cu/Nb, a partial bending of the interfaces occurred, resulting in a localized lattice rotation. The adapted geometry for micro-scale specimens thus successfully captures the shear deformation at predicted sites in two distinct material systems and could potentially be a powerful technique to study the deformation mechanisms.

36 MATERIALS SCIENCE↗

Potential-induced degradation of Cu(In,Ga)Se 2 can occur by shunting the front i-ZnO and by damaging the p-n junction

In this work we test field-relevant potential-induced degradation (PID) behavior by encapsulating laboratory Cu(In,Ga)Se 2 (CIGS) solar cells and applying +1000 V uniformly on the face of the front glass. In this configuration, we find that K-rich borosilicate glass reduces the extent of PID relative to Na-rich soda-lime glass. We also find that the standard testing protocol of stressing cells at short-circuit leads to faster PID than stressing cells at open-circuit. We characterize two types of CIGS PID: The first, front shunting PID, is driven by front-glass stress and occurs when alkali metal cations accumulate in the i-ZnO buffer, where they increase shunt conductance to reduce fill factor. The second, p-n junction PID, results from back-glass stress as alkali metal cations pile up near the CIGS surface/CdS buffer, where they reduce charge carrier concentration, open-circuit voltage, and fill factor to degrade efficiency ~160 times faster than front shunting PID.

14 SOLAR ENERGY↗

Application of photon Doppler velocimetry to direct impact Hopkinson pressure bars

Direct impact Hopkinson pressure bar systems offer many potential advantages over split Hopkinson pressure bars, including access to higher strain rates, higher strains for equivalent striker velocity and system length, lower dispersion, and faster achievement of force equilibrium. Currently, these advantages are gained at the expense of all information about the striker impacted specimen face, preventing the experimental determination of force equilibrium, and requiring approximations to be made on the sample deformation history. In this paper, we discuss an experimental method and complementary data analysis for using photon Doppler velocimetry to measure surface velocities of the striker and output bars in a direct impact bar experiment, allowing similar data to be recorded as in a split bar system. We discuss extracting velocity and force measurements, and the precision of measurements. Results obtained using the technique are compared to equivalent split bar tests, showing improved stress measurements for the lowest and highest strains in fully dense metals, and improvement for all strains in slow and non-equilibrating materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sparse multitask regression for identifying common mechanism of response to therapeutic targets

Motivation: Molecular association of phenotypic responses is an important step in hypothesis generation and for initiating design of new experiments. Current practices for associating gene expression data with multidimensional phenotypic data are typically (i) performed one-to-one, i.e. each gene is examined independently with a phenotypic index and (ii) tested with one stress condition at a time, i.e. different perturbations are analyzed separately. As a result, the complex coordination among the genes responsible for a phenotypic profile is potentially lost. More importantly, univariate analysis can potentially hide new insights into common mechanism of response. Results: In this article, we propose a sparse, multitask regression model together with co-clustering analysis to explore the intrinsic grouping in associating the gene expression with phenotypic signatures. The global structure of association is captured by learning an intrinsic template that is shared among experimental conditions, with local perturbations introduced to integrate effects of therapeutic agents. We demonstrate the performance of our approach on both synthetic and experimental data. Synthetic data reveal that the multitask regression has a superior reduction in the regression error when compared with traditional L1-and L2-regularized regression. On the other hand, experiments with cell cycle inhibitors over a panel of 14 breast cancer cell lines demonstrate the relevance of the computed molecular predictors with the cell cycle machinery, as well as the identification of hidden variables that are not captured by the baseline regression analysis. Accordingly, the system has identified CLCA2 as a hidden transcript and as a common mechanism of response for two therapeutic agents of CI-1040 and Iressa, which are currently in clinical use.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Observation of Electromagnetic Transients in a Nb3Sn 4-layer Dipole Mirror Magnet

During testing of the Stress Managed Cosine-Theta dipole mirror magnet SMCTM1, magnet quenches were observed following large voltage spikes in the half-coil voltage taps which preceded normal quench initiation. Following some recent work at CERN measuring power current converter transients in relation to flux jumps, an additional differential current probe was added to the magnet instrumentation. Measurements of this probe, as well as the half coil voltage taps show a fast and substantial current change preceding the quench, hinting at coil motion. A simple model based on relative shift of the inner and outer layer coils was developed which suggests the magnitude of coil shift events is on the estimated relative coil shift from the magnet constraint conditions. The behavior is shown to be reversible and characteristic of stick-slip.

Krave, Steven [Fermilab] (ORCID:0000000217521457)↗

DHS HS-STEM Internship Summary Report

I had the opportunity to work at Lawrence Livermore National Laboratory within the MEMS, Electronics, and Photonics Technologies group. I worked under the direct supervision of Dr. Adam Conway and Dr. Erik Swanberg on a semiconductor based gamma ray detector. My work involved automating the experimental setup and data analysis portion of the project to alleviate the researcher’s busy schedules. A semiconductor is a material that has conductivity in between a metal and ceramic. In layman’s terms, if you provide it with just enough energy, charge can flow inside of the material. If we impose some form of ionizing radiation such as a gamma ray, we can detect the amount of energy imparted on the system by measuring the amount of charge produced in the material. Figure 1 outlines the process that a semiconductor undergoes to allow us to detect ionizing radiation. Certain materials properties make them ideal for gamma ray detection such as the average atomic number, carrier properties, resistivity, and bandgap energy. I was working with Thallium Bromide (TlBr) detectors for room temperature detection of gamma rays, specifically looking at how different metal electrodes affected the stability of our system. My work involved automating the stress and voltage tests applied to the TlBr detectors and allowing for easy analysis of the data to determine if the system was still functional.

36 MATERIALS SCIENCE↗

NINTH INTERIM STATUS REPORT: MODEL 9975 PCV O-RING FIXTURE LONG-TERM LEAK PERFORMANCE

A series of experiments to monitor the aging performance of Viton® GLT O-rings used in the Model 9975 package has been ongoing since 2004 at the Savannah River National Laboratory. One approach has been to periodically evaluate the leak performance of O-rings being aged in mock-up 9975 Primary Containment Vessels (PCVs) at elevated temperatures. Other methods such as compression-stress relaxation (CSR) tests and field surveillance are also on-going to evaluate O-ring behavior. Seventy tests using PCV mock-ups were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially and have been tested periodically to determine if they continue to meet the leak-tightness criterion defined in ANSI standard N14.5-97. Due to material substitution, fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF. High temperature aging continues for 23 GLT O-ring fixtures at 200 – 270 ºF. Room temperature leak test failures have been experienced in all of the GLT O-ring fixtures aging at 350 ºF and higher temperatures, and in 8 fixtures aging at 300 ºF. The earliest 300 °F GLT O-ring fixture failure was observed at 34 months. The remaining GLT O-ring fixtures aging at 300 ºF have been retired from testing following more than 5 years at temperature without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 ºF for 72 - 96 months, which bounds O-ring temperatures anticipated during storage in K-Area Complex (KAC). Based on expectations that the 200 ºF fixtures will remain leak-tight for a significant period yet to come, 2 additional fixtures began aging in 2011 at 270 ºF, with hopes that they may reach a failure condition before the 200 ºF fixtures, thus providing additional time to failure data. High temperature aging continues for 6 GLT-S O-ring fixtures at 200 – 300 ºF. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400 ºF. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 - 300 ºF for 54 - 57 months. No additional O-ring failures have been observed since the last interim report was issued. Aging and periodic leak testing will continue for the remaining PCV fixtures. Additional irradiation of several fixtures is recommended to maintain a balance between thermal and radiation exposures similar to that experienced in storage, and to show the degree of consistency of radiation response between GLT and GLT-S O-rings.

42 ENGINEERING↗

Tenth Interim Status Report: Model 9975 O-Ring Fixture Long-Term Leak Performance

A series of experiments to monitor the aging performance of Viton ® GLT O-rings used in the Model 9975 package has been ongoing since 2004 at the Savannah River National Laboratory. One approach has been to periodically evaluate the leak performance of O-rings being aged in mock-up 9975 Primary Containment Vessels (PCVs) at elevated temperatures. Other methods such as compression-stress relaxation (CSR) tests and field surveillance are also on-going to evaluate O-ring behavior. Seventy tests using PCV mock-ups were assembled and heated to temperatures ranging from 200 to 450 °F. They were leak-tested initially and have been tested periodically to determine if they continue to meet the leak-tightness criterion defined in ANSI standard N14.5-97. Due to material substitution, fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 °F.

42 ENGINEERING↗

Model 9975 O-Ring Fixture Long-Term Leak Performance (Tenth Interim Status Report)

A series of experiments to monitor the aging performance of Viton® GLT O-rings used in the Model 9975 package has been ongoing since 2004 at the Savannah River National Laboratory. One approach has been to periodically evaluate the leak performance of O-rings being aged in mock-up 9975 Primary Containment Vessels (PCVs) at elevated temperatures. Other methods such as compression-stress relaxation (CSR) tests and field surveillance are also on-going to evaluate O-ring behavior. Seventy tests using PCV mock-ups were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially and have been tested periodically to determine if they continue to meet the leak-tightness criterion defined in ANSI standard N14.5-97. Due to material substitution, fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF. High temperature aging continues for 23 GLT O-ring fixtures at 200 – 270 ºF. Room temperature leak test failures have been experienced in all of the GLT O-ring fixtures aging at 350 ºF and higher temperatures, and in 8 fixtures aging at 300 ºF. The earliest 300 °F GLT Oring fixture failure was observed at 34 months. The remaining GLT O-ring fixtures aging at 300 ºF have been retired from testing following more than 5 years at temperature without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 ºF for 84 - 108 months, which bounds O-ring temperatures anticipated during storage in K-Area Complex (KAC). Based on expectations that the 200 ºF fixtures will remain leak-tight for a significant period yet to come, 2 additional fixtures began aging in 2011 at 270 ºF, with hopes that they may reach a failure condition before the 200 ºF fixtures, thus providing additional time to failure data. High temperature aging continues for 5 GLT-S O-ring fixtures at 200 – 300 ºF. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400 ºF, and in one GLT-S O-ring fixture aging at 300 ºF. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 - 250 ºF for 66 months. One O-ring fixture has failed since the last interim report was issued. Both O-rings in one GLTS fixture aging at 300 ºF failed to remain leak-tight after 69 months at temperature. Aging and periodic leak testing will continue for the remaining PCV fixtures. Additional irradiation of several fixtures has been performed in the last year to maintain a balance between thermal and radiation exposures similar to that experienced in storage, and to show the degree of consistency of radiation response between GLT and GLT-S O-rings.

42 ENGINEERING↗

CSR behavior and aging model for the Viton© Fluorelastomer O-rings in the 9975 shipping package

The 9975 Type B shipping package is used within the DOE complex for shipping special nuclear materials. This package is re-certified annually in accordance with Safety Analysis Report for Packaging (SARP) requirements. The package is also used at the Savannah River Site as part of the long-term storage configuration of special nuclear materials. As such, the packages do not undergo annual recertification during storage, with uncertainty as to how long some of the package components will meet their functional requirements in the storage environment. The packages are currently approved for up to 15 years storage, and work continues to provide a technical basis to extend that period. This report describes efforts by the Savannah River National Laboratory (SRNL) to extend the service life estimate of Viton® GLT and GLT-S fluoroelastomer O-rings used in the 9975 shipping package. O-rings of both GLT and GLT-S compositions are undergoing accelerated aging at elevated temperature, and are periodically tested for compression stress relaxation (CSR) behavior. The CSR behavior of O-rings was evaluated at temperatures from 175 to 400 °F. These collective data were used to develop predictive models for extrapolation of CSR behavior to relevant service temperatures (< 156 °F). The predictive model developed from the CSR data conservatively indicates a service life of approximately 37 years for Viton GLT O-rings at the maximum effective service temperature of 156 °F. The estimated service life for Viton GLT-S O-rings is significantly longer.

36 MATERIALS SCIENCE↗

Challenges of Monte Carlo Transport

These are slides from a presentation for Parallel Summer School at Los Alamos National Laboratory. Solving discretized partial differential equations (PDEs) of interest can require a large number of computations. We can identify concurrency to allow parallel solution of discrete PDEs. Simulated particles histories can be used to solve the Boltzmann transport equation. Particle histories are independent in neutral particle transport, making them amenable to parallel computation. Physical parameters and method type determine the data dependencies of particle histories. Data requirements shape parallel algorithms for Monte Carlo. Then, Parallel Computational Physics and Parallel Monte Carlo are discussed and, finally, the results are given. The mesh passing method greatly simplifies the IMC implementation and allows simple load-balancing. Using MPI windows and passive, one-sided RMA further simplifies the implementation by removing target synchronization. The author is very interested in implementations of PGAS that may allow further optimization for one-sided, read-only memory access (e.g. Open SHMEM). The MPICH_RMA_OVER_DMAPP option and library is required to make one-sided messaging scale on Trinitite - Moonlight scales poorly. Interconnect specific libraries or functions are likely necessary to ensure performance. BRANSON has been used to directly compare the current standard method to a proposed method on idealized problems. The mesh passing algorithm performs well on problems that are designed to show the scalability of the particle passing method. BRANSON can now run load-imbalanced, dynamic problems. Potential avenues of improvement in the mesh passing algorithm will be implemented and explored. A suite of test problems that stress DD methods will elucidate a possible path forward for production codes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

FY2018 Status Report: Model 9975 O-Ring Fixture Long-Term Leak Performance

A series of experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the Model 9975 shipping package has been ongoing since 2004 at the Savannah River National Laboratory. One approach has been to periodically evaluate the leak performance of O-rings being aged in mock-up 9975 Primary Containment Vessels (PCVs) at elevated temperature. Other methods such as compression stress-relaxation (CSR) tests and field surveillance are also on going to evaluate O-ring behavior. Seventy tests using PCV mock-ups with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially and have been tested periodically to determine if they continue to meet the leak-tightness criterion defined in ANSI standard N14.5-97. Due to material substitution, a smaller test matrix with fourteen additional tests was initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FY21 Status Report on Creep Rupture Testing at ANL to Support the Development of Alloy 709 Code Case

This report provides an update on the status of the creep rupture testing on the first commercial heat of Alloy 709 in support of the Alloy 709 Code Case development. Creep tests were performed in air on the lever-arm load frames in the Mechanical and Environmental Testing Laboratory at Argonne National Laboratory (ANL). In FY21, the focus was on the age-hardened ESR-1150°C material. Twenty two tests were initiated, among which ten were completed. This report presents the data from the completed tests. Metallographic characterization of the fractured specimens were performed and the results are included. The creep data enabled the preliminary analysis of the creep behavior of this material. The characterization showed the effect of test temperature and stress on the deformation microstructure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Summary of FY2024 Experimental Results to Support Development of New Inelastic Material Models and Validation of Section III, Division 5, Class A Design Rules

To address the data gap crucial for updating existing viscoplastic constitutive material models for the Class A materials in the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code, Section III, Division 5, High Temperature Reactors (ASME, 2023) for inelastic design analysis, Oak Ridge National Laboratory (ORNL) conducted experimental studies on Alloy 800H and Alloy 617 across a range of temperatures up to their maximum temperature limits in Section III, Division 5. The studies aim to characterize the materials' deformation behavior under both strain-controlled mechanical cyclic loading and thermal cycling conditions. This report summarizes ORNL's FY 2024 experimental findings on Alloy 800H and Alloy 617, focusing on pure fatigue tests, cyclic stress-strain curves, thermomechanical fatigue experiments, and verification of the high temperature cyclic damage summation design rules.

36 MATERIALS SCIENCE↗

Creep Resistant Martensitic Steels for Operation at High-Temperatures in Power Generation Applications

Increasing the temperature capabilities of ferritic/martensitic 9-12% Cr steels can help in increasing the operating temperature of land-based turbines and minimize the use of expensive high-temperature alloys in the hot section. A creep resistant martensitic steel, JMP, was developed with the potential to operate at or above 650°C. The design of the alloys originated from computational modeling for phase stability and precipitate strengthening using fifteen constituent elements. Cobalt was used for increased solid solution strengthening, Si for oxidation resistance and different W and Mo concentrations for matrix strength and stability. The JMP steels showed increases in creep life compared to MARBN/SAVE12AD at 650°C for testing at various stresses between 138 MPa and 207 MPa. On a Larson-Miller plot, the performance of the JMP steels surpasses that of state-of-the-art MARBN steel. Approximately 21 years of cumulative creep data are reported for the JMP steels which encompasses various compositions. The relationships between composition-microstructure-creep properties are discussed including characterization of microstructures after >20,000 hours in creep.

Detrois, Martin↗

Operation at Reduced Atmospheric Pressure and Concept of Reliability Redundancy for Optimized Design of Insulation Systems

Electrified transportation is calling for insulation design criteria that is adequate to provide elevated levels of power density, power dynamics and reliability. Increasing voltage levels are expected to cause accelerated intrinsic and extrinsic aging effects which will not be easily predictable at the design stage due to a lack of suitable modeling. Designing reliable insulation systems would require finding solutions able to control accelerated aging due to an unpredictable increase of intrinsic stresses and the onset of extrinsic stresses as partial discharges. This paper proposes the concept of reliability redundancy for the insulation design of aerospace electrical asset components, which is also validated at lower-than-standard atmospheric pressure. The principle is that extrinsic-aging-free design might be achieved upon determining the aging stress or abnormal service stresses distribution and being sure that aging will not generate conditions that can incept extrinsic aging (partial discharges) during operation life. However, such information is never, in practice, fully available to insulation system designers. Hence, especially in critical applications such as electrified aircraft, aerospace, and combat ships a further level of reliability should be added to a partial-discharge-free design, which can consist of the use of corona-resistant materials and/or of life models able to consider the accelerated aging effect of partial discharges (or any other type of extrinsic-accelerated aging factor). Innovative life modeling considering both extrinsic and intrinsic aging stresses, insulating material testing to estimate model parameters, and a metric for quantifying the extent of corona (or partial discharge) resistance can lead to establishing feasibility and limit conditions for optimized or fully reliability-redundant design. It is shown in the paper that if an extrinsic-aging-free design is not feasible, and it is therefore replaced by a redundant design, a further level of reliability redundancy can be provided by effective condition monitoring plans.

Montanari, Gian Carlo↗